er Build it right, start to finish TM

Similar documents
Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Senturion TM III Wall System

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

PAREXEIFS EXTERIOR INSULATION AND FINISH SYSTEM

Senturion TM I Wall System

3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)

Detail Booklet StoTherm ci XPS

BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

Senershield -R / Senershield -VB

BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate

R E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E

CON-DEK ICC-ES ESR-2097 SYSTEM

19 East Ave. Mullica Hill, N.J Phone: Fax: ARCHITECTURAL FOAM FABRICATORS, LLC.

application instructions

RENOVATION SOLUTIONS FROM DRYVIT

SPECIFICATION GUIDELINE

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

The better way to build TM. Installation Manual NAILBASE PANELS

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Inspection Fundamentals: Stucco & EIFS

BACKSTOP NT - VB A high performance, non-cementitious water-resistive membrane and air/vapour barrier

Weatherproofing & Sealing Systems

SPECIFICATION GUIDELINE

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

Finestone Stucco Ultra Wall System

Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Finestone Stucco System

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

Sto Guide Specification No. F601S StoQuik Gold Finish System for Soffits and Ceilings

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

Parex USA Stucco Details CSI SECTION

BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier. Backstop NT - Texture Application Instructions

Acrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system

Magnum Board Coatings

Weatherproofing & Sealing Systems

SC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish

Discussion of the Stucco Identification of All Panels

This is what you see. DS 265

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Beginning of the Course

Architectural Wall Products Guide Specifications

Forensics Engineering 8th Congress Forging Forensic Frontiers November 29 December 2, 2018, Austin, TX

MASONRY VENEER SYSTEMS

Stucco and EIFS Wall Systems

INTRODUCING NEWBRICK. The most important innovation in the history of brick. Office Building Schenectady, NY DS277

DMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing

Compliance for Continuous Insulation, Water Resistive Barriers & NFPA-285 What you need to Know

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

RENOVATION SOLUTIONS FROM DRYVIT

Technical Data Sheet

Accent is cracked with stains Accent is sloped away from the home Flat accent is not sealed to window

WeatherSmart Air Barrier Installation Guide

Water Management with Drainage Wrap System Page 1 of 9

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

SECTION SELF-ADHERING SHEET FLASHING

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

A. Meet at Project site <insert number> days before starting installation.

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

Installation Guide Sto RapidGuard

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

breathability to prevent the potential for moisture condensation within exterior walls...

.1 Provide textured finish system for gypsum or cement board soffit and ceiling surfaces.

DuPont Tyvek Wall Underlay Install Guide

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

DuROCK ICF Finish System

Verea Spanish S Roof Tile Installation Guide

FEDDERLITE PANEL SYSTEM Prefabricated, Lightweight, Outsulation Exterior Wall Panels with Integrated Reinforcing Channels

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: AVM INDUSTRIES, INC.

Primary Concerns and Defects

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN

Aqua Coast Engineering

SECTION WATER-DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS)

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

SSL-175. Specifications

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3

Armourwall Stucco Systems

SURESILL WATER MANAGEMENT GUIDE

Verea Spanish S Roof Tile Installation Guide

PlyDry is specified by builders who need a perforated housewrap that meets code requirements at a very affordable price...

QUICKFLASH READY- MADE FLASHINGS. Product. Scope. Building Regulations. Appraisal No. 688 [2018]

SECTION 7307 CONCRETE/ CLAY TILE, METAL, SLATE AND ASPHALT COMPOSITION SELF-ADHERED/ PEEL & STICK ROOF UNDERLAYMENT

Chapter 2 Understanding The Problem

Lightweight, insulated, energy efficient cladding changing the way we think about masonry construction.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Transcription:

WORLD-CLASS STARTER BOARDS TM er Build it right, start to finish TM FASTER, STRONGER AND BETTER THAN BACK WRAPPING IBC Code Approved ESR-2931, Full Dryvit Warranty AC9052

WHY DRYVIT SHAPES BY ACROCORE WARRANTY: EVERYONE BENEFITS: = FULL DRYVIT SYSTEM WARRANTY An additional two (2) years of warranty coverage is available when Dryvit Shapes by Acrocore or Starter Boards are used with an Outsulation system. CODE COMPLIANT Complies with NFPA 285 and other building code requirements for use in Construction Types I-V. ARCHITECTS Have the ability to specify a complete Outsulation system using pre-coated starter boards and architectural shapes with a single source warranty. BUILDING OWNERS Have unlimited design options and possibilities, a full Dryvit system warranty and better quality finished product. CONTRACTORS Will save time, labor, money and create a higher quality job. FTL SHIPPING LOGISTICS SHIPPING TIMEFRAME* Next Day 2 Day 3 Day 4 Day 5 Day Call for timeframe ALASKA PUERTO RICO HAWAII DOMINICAN REPUBLIC US VIRGIN ISLANDS Headquarters & Manufacturing West Coast Distribution Dryvit Starter Boards can arrive at any destination coast to coast within 5 days. Contact us for international rates and delivery schedule. *Shipping dates may vary based on inventory availability, weekends and holidays. TO PLACE AN ORDER, PLEASE CONTACT YOUR LOCAL DRYVIT DISTRIBUTOR

FASTER n STRONGER n EASIER n BETTER STARTER BOARDS : n Not only eliminate the need to back wrap* mesh at termination details, they provide 3 sides of Polymer Modified Cement n Provides a proper surface for sealant at expansion joints n Provides closure at system terminations n Eliminate the need for the Dryvit Drainage Strip TM with moisture drainage systems * Where Starter Boards abut each other, the joint must be back wrapped with Dryvit Detail Mesh and Dryvit Base Coat. PRODUCT BENEFITS: n LABOR SAVINGS (3x Faster) n IMPACT RESISTANT (Pliable / Polymer Modified Cement) n LONGER LASTING (3x Thicker Base Coat) n BUILDING CODE COMPLIANT Approved for use in Types I-V Construction - ICC ESR-2931 n FULL DRYVIT WARRANTY SUPPLIED IN 8 LENGTHS 1 1.5 2 2 with Bevel 2 with Drip Edge HOW IT WORKS: n Typical OUTSULATION system n Dryvit Shapes by Acrocore Starter Board TM Dryvit Detail Mesh embedded in Dryvit Base Coat at starter board joints. Overlap Detail Mesh 2 1/2 (64mm) minimum onto each board and wrap to backside 2 (51mm) minimum The architecture, engineering, and design of the project using Acrocore Exterior Mouldings LLC and/or Dryvit Systems, Inc. products is the responsibility of the project s design professional. All systems must comply with local building codes and standards. This detail is for general information and guidance only and Acrocore Exterior Mouldings LLC and/or Dryvit Systems, Inc., specifically disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. The project design professional determines, in its sole discretion, whether this detail or a functionally equivalent detail is best suited for the project. Use of a functionally equivalent detail does not violate the Dryvit s Systems, Inc. warranty. This detail is subject to change without notice. Contact Dryvit Systems, Inc. to ensure you have the most recent version.

STARTER BOARDS ASSURE PROPER SYSTEM TERMINATIONS WHILE SAVING TIME 1 2 3 4 5 6 Grade Termination Concrete Curb ADA Compliant Sidewalk Waterproof Deck Parapet Cap Flashing Parapet Solid Substrate 7 8 9 10 11 12 Sloped Roof Roof Stop Flashing Vertical wall/suspended Soffit Transition Soffit/Facia intersection Facia/Uninsulated Soffit Transition Horizontal Slip Joint without Weeps 13 14 15 16 17 18 Horizontal Slip Joint with Weeps Horizontal Joint Substrate Change at Stone Veneer at Stucco at Wood Siding Joint EIFS 19 20 21 22 23 Through Wall Expansion Joint Joint Flush Option Joint Recessed Option Joint Double Seal Option Vertical Termination at Stone Veneer Outsulation Plus MD System details shown for clarity. Additional information is available at: www.dryvit.com

Additional information is available at: www.dryvit.com To place an order, please contact your local Dryvit Distributor www.dryvitshapes.com n 800-213-2183 Acrocore Exterior Mouldings, LLC One Ackerman Avenue, Clifton, NJ 07011 AC9052-10/16 2016 Acrocore Exterior Mouldings, LLC / Dryvit Shapes by Acrocore. Outsulation, Outsulation Plus MD, Detail Mesh and Dryvit Drainage Strip are registered trademarks of Dryvit Systems, Inc.