Enhanced energy-efficiency, safety and design contextualism drive forward our mission to create the escalators of the future, utilizing our advanced

Similar documents
carry passengers Our new escalator Series Z offers more than just a way to


Distributed by. SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice.

OPTIONS AND PLANNING DIMENSIONS

KONE TransitMaster 120 escalators

KONE TravelMaster 110 escalators

Styling. Exceptional Styling

Escalator. KOYO Elevator Co., Ltd.

OPTIONS AND PLANNING DIMENSIONS

KONE TravelMaster 110 escalator

Elevators and Lifts

Schindler 9500AE Inclined Moving Walks, Types 10/15 When Being on the Fast Track Brings You Peace of Mind.

KONE TravelMaster 115 inclined autowalks

VPL-3200B Residential Vertical Platform Lift Technical Specifications

OPTIONS AND PLANNING DIMENSIONS

DEPARTMENT OF ARCHITECTURE ABUBAKAR TAFAWA BALEWA UNIVERSITY, BAUCHI ARC 624: ADVANCED BUILDING SERVICES LESSON 2: CONVEYANCE SYSTEMS IN BUILDINGS

Schindler Modernization Signal Combs

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

ThyssenKrupp Elevator Americas

HEAVY-DUTY SOLUTIONS FOR HEAVY-DUTY ENVIRONMENTS. KONE solutions for transit centers

Schindler 9500 Type 30 and 35 Horizontal Moving Walk The Reliable Solution for Public Transportation

Safeele. Safeelevator Co.,Ltd. Lifting The World With Ease

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

HEAVY-DUTY SOLUTIONS FOR HEAVY-DUTY ENVIRONMENTS. KONE solutions for transit centers

Bryan County Middle/High Renovation SECTION TELESCOPING STANDS

HEAVY-DUTY SOLUTIONS FOR HEAVY-DUTY ENVIRONMENTS. KONE solutions for transit centers

KONE EcoMaster 130/135 Escalators and Inclined Autowalks SUPERIOR TECHNOLOGY AND ABSOLUTE RELIABILITY FOR RETAIL NEEDS

SPECIFICATION FOR PERMANENT BEAM GRANDSTAND WITH INTERLOCK WELDED DECK SYSTEM

The versatile moving walk for extended travel.

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

Schindler 9500 Horizontal Moving Walk. The Reliable Solution for Public Transport. Type 35

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

ELVORON LU/LA ELEVATOR

Introduction. Disclaimer. Table of contents

ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

City of Santa Monica Building and Safety Division

Power Zone Center. Your solution for power distribution and control systems

SHERIDAN SEATING INC.

RESIDENTIAL BUILDING PLAN REQUIREMENTS

HEAVY-DUTY SOLUTIONS FOR HEAVY-DUTY ENVIRONMENTS. KONE solutions for transit centers

Product Catalog. Made in the USA

Freight Elevator Series GFM-T

Joylive. Passenger elevator / Panoramic elevator / Freight elevator / Escalator. Joylive Elevator Co., Ltd.

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Freight Elevator Series GFM-T

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator

escalators & moving walkways

Specification for Borehole Freight Elevators

Specification for Holeless Freight Elevators

Vertical Offset Conveyors

Barrier. Delimitation. Water drainage

Missouri Army National Guard (RTI) MOARNG Project No. T Rev. 0 Ft. Leonard Wood, Missouri 15 April 2013 Bid Final Submittal

SOLUTION FOR BUILDINGS WITHOUT AN ELEVATOR. KONE ProSpace

DESIGN REFERENCE FOR ELEVATOR INSTALLATIONS. Designed to European standards

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

The S.15 ALL WOOD WITH ALUMINUM CORE LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

A. Section includes busway and fittings including plug-in units.

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

A PLEASANT FLIGHT BEGINS AND ENDS AT THE AIRPORT. KONE solutions for airports

Division 14 Conveying Systems

Cement Bucket. Bucket Elevator

Sprinkler Identification Numbers (SINs)

Chapter 7. Passive Solar Contents

HAZOP Checklist for Sewage Treatment Plant

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

Escalators and Moving Walks PLANNING GUIDE v.06. Imagine the Possibilities. ThyssenKrupp. ThyssenKrupp Elevator. Americas Business Unit

TECHNICAL SPECIFICATION

SECTION SERIES ALL GLASS ENTRANCES

Stack Parking Surface Mounted Stackers

Section X - Miscellaneous

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

Section 32 - Miscellaneous

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

imperband refurbishing kit

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100

SECTION NON-STRUCTURAL METAL FRAMING

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

T1. Steps and stairs general

SECTION The specification section is organized by placing information in three standard parts:

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

PROPOSED ELEVATOR SYSTEM WORKS FOR CRUISE SHIP TERMINAL BERTH 1 - PHASE 1C FOR KENYA PORTS AUTHORITY LTD KG 13 PERSONS LIFTS (2NO)

SHERIDAN SEATING INC.

Commercial Sectional Doors

a difficult challenge when trying to achieve effective coverage within a shallow space. The Model CC1 Combustible

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

INDUSTRIAL GUARDRAIL SYSTEMS

SECTION INCLINE WHEELCHAIR LIFT PART 1 GENERAL 1.1 SECTION INCLUDES. A. Stair wheel chair lift. 1.2 RELATED SECTIONS

SECTION IMPACT RESISTANT WALL PROTECTION

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec

Hotel/Motel. Slip, Trip and Fall Self Inspection Checklist. Completed by: Date: Time:

SHAWN E. JOHNSON, C.E.I. Elevator/Escalator Expert

SITE ACCESSIBILITY AND PARKING

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

Utility Cabinet System (UCS)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

Transcription:

ESCATORS For USA

Enhanced energy-efficiency, safety and design contextualism drive forward our mission to create the escalators of the future, utilizing our advanced technologies. 1 2

Principle Based on our policy, Quality in Motion, we provide elevators and escalators that will satisfy our customers with high levels of comfort, efficiency, ecology and safety. Contents Models for Various Scenes 5-6 Safety 7-8 Comfort 9-1 Specifications 11-12 Safety Devices 13-14 Layout 15-16 Remote Monitoring / Notes for Use 17 Important Information 18 Dimensions Rise 7-2 5/8 to 29-6 5/16 (22 to 9mm) We strive to be green in all of our business activities. We take every action to reduce environmental burden during each process of our elevators and escalators lifecycle. Step width S24 : 1-11 3/4 (S6: 64mm) S32 : 2-7 5/8 (S8: 84mm) S4 : 3-3 1/2 (S1: 14mm) Inclination 3 Moving handrail height 3-3 3/8 (1mm) 3 4

Models for Various Scenes Simple designs and stylish curves matched to diverse settings Glass Panel SAS Panel SAP Moving Handrails *1, *2 Rubber No.1 No.52 Black Vermilion No.53 Red No.54 Yellow No.55 Green No.56 Blue No.57 Light gray No.58 Brown Polyurethane No.51 Black No.52 Vermilion No.53 Red Moving handrails made of polyurethane are highly resistant to dirt on their surface and create a shiny and brighter look. No.54 Yellow No.55 Green No.56 Blue No.57 Light gray No.58 Brown No.59 Mild black No.51 Warm gray Notes: 5 *1: Handrail colors for outdoor use are different from those shown. Please contact our local agents for details. *2: Actual handrail colors may differ slightly from those shown. 6

Safety Features Supporting the Safety of All Users Various features that ensure the safety of all users from the elderly to children and support users in boarding and getting off escalators smoothly Low-Friction Material on Skirt Guard The skirt guards have a special painting/coating on the surface, ensuring a low coefficient of friction and minimizing the risk of items getting caught. Tiered Demarcation Line Demarcations along both sides of a step are raised from the step surface, providing enhanced safety. Skirt Brush Skirt brushes installed on the skirt guard prevent passengers clothes or shoes from getting caught between the step and the skirt guard. *1 Step with Anti-Slip Grooves Grooves along the corner edge of each step improve anti-slip performance and the visibility of each step for further passenger safety. Light Step Demarcation Lighting Lighting provided at comb level and under the steps improves passenger safety at boarding and landing areas. Brighter Demarcation Color The brightness of the yellow demarcation lines has been improved to provide better visibility. with Smaller Angle We have made the angle the smallest it can be to keep passengers from tripping at boarding and landing areas. Note: 7 *1: Please note that passengers' clothes or shoes may be dirtied if the brushes get dirty after a long period of use. 8

Comfort Functional Beauty Inspired by Users Universal designs that pursue true user-friendliness and smart design features based on maximum consideration of users Fault Indicator If a fault occurs on the escalator, the fault indicator displays the fault code, and the operation manager can judge whether the operation can be resumed by the color of the lamp indicated next to the fault code. The indicator displays the operation speed in normal operation. Example of indication: At fault occurrence (Fault code) At normal operation (Operation speed; for example, 5 when the operation speed is 1fpm [.5m/sec]) Direction Indicator Floor Name LEDs form an arrow to indicate the travel direction of the escalator at the boarding area, or a no-entry sign at the landing area. SAS SAP Floor names can be engraved on each floor plate to help passengers quickly identify which floor they are on. Hairline-finished stainless steel At boarding area At landing area 9 1

S pecifications Basic specifications Applications :, : N/A: Not applicable Item Models Codes Power supply Lighting power supply Rated speed Control system Theoretical transport capacity (*1) Inclination Environment Min. rise (mm) Max. rise (mm) Step width (mm) Escalator width (mm) Between moving handrails (mm) Between skirt guards (mm) Truss width (mm) Floor opening (mm) S24 (S6) S32 (S8) S4 (S1) SAS/SAP ASME A17.1 AC 3-phase, 6Hz AC single-phase, 6Hz 1fpm (.5m/sec) : AC1 45 675 9 3 :, : Semi-outdoor / (*2) 7-2 5/8 (22mm) 29-6 5/16 (9mm) 1-11 3/4 (64mm) 2-7 5/8 (84mm) 3-3 1/2 (14mm) 3-9 1/4 (115mm) 4-5 1/8 (135mm) 5'-1 (155mm) 2-9 1/16 (84mm) 3-4 15/16 (14mm) 4-13/16 (124mm) 1-11 15/16 (68mm) 2-7 13/16 (88mm) 3-3 11/16 (18mm) 3-7 5/16 (11mm) 4-3 3/16 (13mm) 4-11 1/16 (15mm) 4-1 3/16 (125mm) 4-9 1/16 (145mm) 5-4 15/16 (165mm) Notes: *1: Transport capacity varies depending on actual traffic conditions, so some dimensions and the motor capacity may have to be changed. Please contact your local Mitsubishi Electric sales agent for details if the number of passengers during peak time may equal or exceed the following numbers: S24 (S6): 5 persons per 1 minutes. S32 (S8): 75 persons per 1 minutes. S4 (S1): 1 persons per 1 minutes. *2: Please contact your local Mitsubishi Electric sales agent for semi-outdoor and outdoor use. For outdoor use, please refer to Notes for Use on page17. Control system Horizontal steps Indicator Finish and decorative components Others Division Specification AC1: Manual key switch operation 2 horizontal steps Direction indicator (LED) Fault indicator (LED) Interior panel Transparent tempered glass See page 11 for the sections of the balustrade., -finish Low-friction paint finish (black) Skirt guard Skirt brush Aluminum Inner deck Deck, -finish board Aluminum Outer deck, -finish Aluminum alloy step tread (Black) Aluminum alloy cleat riser (Black) Step Step with anti-slip grooves Yellow demarcation line Embossed stainless-steel plate (with black-paint grooves) Floor name (with black-paint grooves) Extension of floor plate Connection of adjacent floor plates Molded resin (yellow) No. 1 (black) Rubber Moving handrail No. 52 to 58 (See page 5 for the colors.) No. 51 (black) Polyurethane No. 52 to 51 Handrail inlet cap Resin (black) MelEye Automatic oiler Notes: *1: Please contact your local Mitsubishi Electric sales agent for outdoor use. *2: The aluminum-finish deck board may not be available depending on the factory. / Semi-outdoor (*1) SAS SAP N/A N/A *2 N/A *2 N/A :, : Semi-outdoor Sections of the balustrade (Inner deck) (Outer deck ) (Outer deck) Aluminum/ Moving handrail Rubber/Polyurethane Guard rail Interior panel Transparent tempered glass (Inner deck) Aluminum/ (Outer deck) Corner deck Outer panel (by owner) Moving handrail Rubber/Polyurethane Guard rail Interior panel (Inner deck) Interior panel Skirt guard Handrail inlet cap Moving handrail Emergency stop button SAS SAP 11 12

Safety Devices Various safety devices ensuring high levels of safety and reliability 1 Handrail Entry Device (HGS) (Handrail Guard Safety Device) 1 Handrail-Speed Monitoring Device (HSS) (Handrail Speed Safety Device) 13 Electromagnetic Brake 1) Inlet Guard A guard made of soft rubber, which fits over the outside of the moving handrail where it enters the balustrade to keep fingers, hands or foreign objects away from the moving handrail opening 2) Inlet Guard Switch A safety device that stops escalator when physical contact is made with the inlet 15 1 2 3 4 5 6 11 A safety device that stops the escalator if the moving handrails fail to synchronize with the steps because of slippage, loosening or breakage of the moving handrails Broken Drive-Chain Device (DCS) (Drive-Chain Safety Device) A safety device that stops the escalator if the drive chain breaks or stretches beyond an allowable limit 14 A safety device that stops the escalator in the case of power failure, or if any safety device or the emergency stop button has been activated Overload Detection Device A safety device that stops the escalator if overload has been detected by abnormal current or temperature of the drive motor 2 3 Emergency Stop Button (E-STOP) A button to immediately stop the escalator in emergency situations -Step Impact Device (CIS) 14 7 12 Speed Governor/Reversal Stop Device (GOV) A safety device that stops the escalator before the operating speed exceeds 12% of the rated speed or if the operation speed becomes unusually slow 15 Door Open Switch (DOS) () A safety switch that stops the escalator when the floor plate is opened : : A safety device that stops the escalator if a horizontal or vertical movement of a comb is detected due to an entrapped foreign object or the impact from external forces 13 12 11 1 9 4 Skirt Obstruction Device (SSS) (Skirt Guard Safety Device) 7 Skirt Brush () 6 A safety device to stop the escalator if a shoe or other item becomes trapped in the gap between the step and skirt guard A safety device to prevent passengers shoes or clothes from getting caught between steps and skirt guards 5 4 3 2 1 5 Step Up Thrust Device (CRS) (Step Motion Safety Device) 8 Broken Step-Chain Device (SCS) (Step Chain Safety Device) 15 A safety device to stop the escalator when a step has been dislocated on its riser side due to an object caught between the Steps, or between the skirt guard and the step, or if an abnormality has been observed in the step motion A safety device that stops the escalator if the step chain breaks or stretches beyond an allowable limit 6 Step Level Device (SRS) 9 Missing Step Device (SMS) A safety device that stops the escalator if the horizontal level of a step has dropped A safety device that stops the escalator if it detects a missing step(s) before it is visible to passengers 9 8 13 14

L ayout (Unit: ft) Seismic area only Min. 5 11/16 Non-Seismic area only Min. 4 3/4 Floor opening W1+3 15/16 (Unit: mm) NK-2-6 13/16 NJ-2-6 13/16 Seismic area only Min. 1 5/8 * Seismic area only Min. 27* Non- seismic area only Min. 9 13/16 Non- seismic area only Min. 25 Finished floor level Finished floor level Max. LF Lower floor opening Wiring inlet Upper floor opening Max. UF =+9 13/16 Anchor 2 15/16 Distance between support beams +1 9/16 MM 2 15/16 Seismic area only 2 3/8 +13/16 * Anchor 75 Support beam end Truss length +1 3/16 Non-seismic area only 1 15/16 Support beam end Truss end TK HE/tan3 TJ Truss end Support beam section detail (by owner) Support beam section detail (by owner) Seismic area only 2 3/8 +13/16 * Clearance W1 NJ Min. 6-6 3/4 W1 +1 3/16 Safety fence Seismic area only 6 +2 * Non-seismic area only 1 15/16 W2 (by owner) W2 Non-seismic area only 5 +3 Seismic area only Min. 145 Non-Seismic area only Min. 12 Floor opening W1+1 TK NK-782 NJ-782 Max. LF Lower floor opening Upper floor opening =+25 Distance between support beams MM +4 Truss length HE/tan3 Safety fence (by owner) Max. UF NJ TJ Wiring inlet 75 Clearance Min. 2 Seismic area only 6 +2 * Non-seismic area only 5 +3 W3 1-5 5/16 1-5 5/16 Recommended Recommended Rise HE Max. 29-6 5/16 Clearance Min. 6-6 3/4 Ceiling NK R4-11 1/16 Overhead Min. 7-7 5/16 Wedge guard (by owner) 2-1 1/2 3 - Truss R6-1 11/16 W.P. NJ-1-2 7/16 TJ-7 7/8 3-3 3/8 3-4 9/16 2-11 1/16 Wiring inlet W3 44 44 Recommended Recommended Rise HE Min. 232 Clearance Min. 2 Ceiling NK R15 Overhead Min. 232 Wedge guard (by owner) 876 915 Truss R21 W.P. NJ-367 TJ-2 1 13 89 Wiring inlet 3-3 3/8 3-4 9/16 3-7 5/16 W.P. Floor opening NK-1-2 7/16 Min. 6-1 11/16 3 SA Outer sheathing panel (by owner) Height of intermediate support beams,7 1/16 to 3-3 3/8. The number of required intermediate support beams differ depending on truss length (). Refer to table2 for details. Note: * The dimension is applicable when the maximum story drift (at one side) is 1 3/8 in a seismic area. Please contact your local Mitsubishi Electric sales agent if assumed story drift exceeds 1 3/8. 1 13 11 NK-367 3 W.P. Floor opening Min. 21 SA Outer sheathing panel (by owner) Height of intermediate support beams,18 to 1. The number of required intermediate support beams differ depending on truss length (). Refer to table2 for details. Note: * The dimension is applicable when the maximum story drift (at one side) is 35 mm in a seismic area. Please contact your local Mitsubishi Electric sales agent if assumed story drift exceeds 35 mm. Table 1: dimensions Table 1: dimensions Width S24" (S6) S32" (S8) S4" (S1) W1 (escalator width) 3' - 9 1/4" 4' - 5 1/8" 5' - 1" W2 (between moving handrails) 2' - 9 1/16" 3' - 4 15/16" 4' - 13/16" W3 (between skirt guards) 1' - 11 15/16" 2' - 7 13/16" 3' - 3 11/16" Horizontal TJ steps HE 7 7<HE S4" (S1) TK NJ NK UF LF 7' - 11 1/2" 2 steps S32" (S8) 8' - 7 3/8" 7' - 3 5/8" 5' - 9 5/16" 5' - 1 7/16" 4' - 1/8" 3' - 4 3/16" S24" (S6) 8' - 7 3/8" Width S24" (S6) S32" (S8) S4" (S1) W1 (escalator width) W2 (between moving handrails) W3 (between skirt guards) 115 135 155 84 14 124 68 88 18 Horizontal TJ steps HE 7 7<HE S4" (S1) 2425 2 steps S32" (S8) 2625 S24" (S6) 2625 TK NJ NK UF LF 2225 176 156 1223 12 Table 2: No. of intermediate support beam Table 2: No. of intermediate support beam Environment Without 1 beam 2 beams S4" Semi-outdoor (S1) S32" Semi-outdoor (S8) S24" Semi-outdoor (S6) 48' - 8 5/8" 49' - 6 1/2" 5' - 1 1/4" 48' - 8 5/8" < 71' - 4 5/16" 48' - 8 5/8" < 64' - 9 9/16" 49' - 6 1/2" < 71' - 4 5/16" 49' - 6 1/2" < 64' - 9 9/16" 5' - 1 1/4" < 75' - 11 7/16" 5' - 1 1/4" < 64' - 9 9/16" 71' - 4 5/16" < 64' - 9 9/16" < 71' - 4 5/16" < 64' - 9 9/16" < 75' - 11 7/16" < 64' - 9 9/16" < S4" (S1) S32" (S8) S24" (S6) Max., or LC Environment Semi-outdoor 36' - 1 1/16" 32' - 9 11/16" 38' - 4 5/8" Environment Without 1 beam 2 beams S4" Semi-outdoor (S1) S32" (S8) S24" (S6) Semi-outdoor Semi-outdoor 1485 151 155 1485 < 2175 1485 < 1975 151 < 2175 151 < 1975 155 < 2315 155 < 1975 2175 < 1975 < 2175 < 1975 < 2315 < 1975 < S4" (S1) S32" (S8) S24" (S6) Max., or LC Environment Semi-outdoor 11 117 1 LC LC RD RD Table 3: Loads (N) Table 3: Loads (N) Without intermediate support beam β1 (-TK+X1) + α + With intermediate support beam 1 beam 2 beams α +β1 - Factors α S4" (S1) α (lb/in) 24.2 Without intermediate support beam β1 (-TK+X1) + α + With intermediate support beam 1 beam 2 beams α +β1 - Factors α S4" (S1) α (N/mm) 4.24 + β2 (-TJ+X2) α + α +β2 - S32" (S8) S24" (S6) 22. 19.9 + β2 (-TJ+X2) α + α +β2 - S32" (S8) S24" (S6) 3.86 3.49 α + + α (+LC) + X1, X2, β1, β2 α + + α (+LC) + X1, X2, β1, β2 RD α (+LC) + Horizontal steps X1 (ft, in) X2 (ft, in) β1 (lb) β2 (lb) 2 steps 3' - 3 5/16" 3' - 1 3/4" 112 3125 RD α (+LC) + Horizontal steps X1 (mm) X2 (mm) β1 (N) β2 (N) 2 steps 999 1188 45 139 15 16

Remote Monitoring Mitsubishi Electric s MelEye is a sophisticated Web-based elevator and escalator monitoring and control*1 system that allows authorized personnel to respond rapidly to changing traffic patterns and other operational conditions. It improves passenger safety and reliability of your building management. Notes for Use A roof must be provided over outdoor escalators. In rainy weather without a roof, passengers are in great danger of having their umbrellas blown away by the wind or falling down on the slippery steps. In hot weather, the moving handrails and deck boards can easily heat up in the sun to a surface temperature exceeding 122F (5 C), causing the unnecessary chance that passengers could get burnt on the overheated elements. In addition, when not covered by a roof, the life and performance of outdoor escalators seriously deteriorate, leading to shorter product life and higher cost for maintenance. 1. How to define outdoor escalators Escalators are classified into three categories: outdoor, semi-outdoor and indoor. escalators are defined as escalators exposed to environmental factors such as wind, rain, snow or direct sunlight. α Roof end Slope Floor-plate end 2. Environmental requirements for outdoor escalators α User-friendly screens Operational failures and errors will be highlighted for easier recognition on the screen and to improve rapid troubleshooting. *1: Please note that MelEye is designed for monitoring of escalator operation, not to control the escalators remotely. Semi-outdoor Interface box α>7 7 α 3 α<3 Angle α in the illustration varies depending on the direction in which the escalator is viewed. Check how the angle varies, take the smallest angle, apply it to the table above and determine the escalator type. I mportant Information Work not included in the escalator contract The following items are not included in Mitsubishi Electric s escalator installation work, and the responsibility for carrying them out lies with the building owners or general contractors: Building construction and alterations associated with escalator installation Provision of intermediate support beams (if required) Provision of truss-supporting beams, including mounting plates Floor finishing after escalator installation Provision of fire-proofing and fire-prevention measures for escalator exterior materials and around escalator installation Provision of fire-prevention shutters (if required by local codes or regulations) Wiring for the escalator s main drive and lighting, from around the middle portion of the truss to the escalator s control unit in the upper truss Other wiring and electric conduits Provision of convenience outlets in the upper and lower truss Outer panel sheathing of truss Provision of inspection doors (lockable doors if installed in an environment where anyone could access and open the doors) All items for which procurement by building owners is instructed (with wording such as by owner ) Notes on building work Tolerance in distance between supporting beams: +1 3/16 (+3mm) to (mm) Flooring around the escalator must not be finished until the escalator is installed. Flooring within 11 13/16 (3mm) of the escalator floor plate must not be finished until the floor plates are in place. Sprinkler pipes or wiring for soffit lights, or any other electric conduits for items other than escalator, must not be laid inside the truss. No walls or other parts of the building structure must be supported on the truss. Allowable maximum weight of outer sheathing: 4.1lbf/ft 2 (196N/m 2 ) Permissible ambient temperature Wind pressure Others Minimum For escalator operation 14F (-1 C) (Special measures are required in cold districts where the ambient temperature can drop below 14F (-1 C).) 32F ( C) to less than 95F (35 C) Escalators must not be exposed to direct wind pressure outside the following ranges: 1lbf/ft 2 (49N/m 2 ) or less on the windward side, 5lbf/ft 2 (245N/m 2 ) or less on the leeward side Measures are required for escalators installed within a radius of 1.24 miles (two-kilometer) from a shore to protect them from direct exposure to salty wind. 3. Architectural requirements for outdoor escalators (1) Intermediate support beams must be provided. Detailed floor plan for outdoor escalators (2) The level of the escalator floor plate must be higher than the floor finish of the building to minimize the chance of rain or cleaning water running into the escalator truss. Area B in the C illustrations to the right must be at a slope of at least 1, and the surface of A must be B horizontal to minimize the risk of passengers stumbling. A (3) Drainage must be provided in the entire area marked C and covered with grating to keep away drain water. (4) The escalator pit must be waterproofed entirely when a whole truss is installed inside the pit. In addition, the upper pit floor must be sloped towards the lower floor to let any water in the pit drain out and down. (5) If there is a chance of the lower machine room getting flooded, drainage equipment, such as a drain pump, must be provided to discharge any water. (6) Water in the lower pit will contain lubrication oil, so a grease trap should be provided to separate the lubrication oil from the water. The capacity of the grease trap is determined according to the escalator size and maximum amount of expected rainfall. (7) Water may drip from the exterior panels of the escalator. Take waterproofing measures for equipment or items under the exterior panels if water is likely to cause problems or accidents. End of escalator 1 15/16 ~ 11 13/16" (5~3mm) 11 13/16" (3mm) or more A B C 1 3/16" (3mm) or more 17 18

If you have an inquiry about our products, please contact us. Mitsubishi Electric US, Inc. Elevator/Escalator Division Tel: 8-988-8474 / 59-A Katella Avenue, Cypress, California 963, U.S.A. Website: http://www.mitsubishielevator.com Email: EEDSALES@meus.mea.com HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 1-831, JAPAN www.mitsubishielectric.com C-CL1-6-C9865-A INA-169 Printed 216 New publication Sep. 216. Specifications are subject to change without notice.