A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Similar documents
A Novel ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge-Variant Analysis

High-Resolution Charge Variant Analysis for Top-Selling Monoclonal Antibody Therapeutics Using a Linear ph Gradient Separation Platform

CX-1 ph Gradient Buffer

High-Resolution Separation of Intact Monoclonal Antibody Isoforms

Analysis of Monoclonal Antibody and Related Substances using a New Hydrophobic Interaction Chromatography (HIC) Column

ph gradient analysis of IgG1 therapeutic monoclonal antibodies using a 5 µm WCX column

Analysis of Monoclonal Antibodies and Their Fragments by Size Exclusion Chromatography Coupled with an Orbitrap Mass Spectrometer

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

High-speed, High-resolution Oligonucleotide Separations Using Small Particle Anion-Exchangers

The Benefits of SOLAμ Technology in Sample Preparation. Jon Bardsley and Ken Meadows Thermo Fisher Scientific, Runcorn, UK

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

ProPac Elite WCX, 5 μm Particle, for Fast, High Resolution Protein and mab Analysis. July 2018

High-Throughput, High-Resolution Monoclonal Antibody Analysis with Small Particle Size HPLC Columns

Chromatography column for therapeutic protein analysis

Analysis of Fracking Flowback Water From the Marcellus Shale Using In-line Conductivity, Automated Dilution, and Ion Chromatography

Method Optimisation in Bottom-Up Analysis of Proteins

How to Create Your Own Affinity Titer Column. Kelly J. Flook*, Yury Agroskin and Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA

Monoclonal Antibody Analysis on a Reversed-Phase C4 Polymer Monolith Column

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

Simple charge variant profile comparison of an innovator monoclonal antibody and a biosimilar candidate

Thermo Scientific MAbPac HIC Columns. Novel Hydrophobic Interaction HPLC Columns. Designed for Monoclonal Antibody Analysis

In-Cell and External Hydrolysis of Biomass for Carbohydrate Determinations Using Automated Solvent Extraction

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water. Pranathi R Perati Thermo Fisher Scientific, Sunnyvale, CA, USA

Nitrogen Determination in Soils and Plants by Flash Combustion using Argon as Carrier Gas

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Introduction. Yan Liu, Victor Barreto, Rosanne Slingsby, Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA

Implementation of a Walk-Up High- Pressure Capillary Ion Chromatograph for the Fast Separation of Pharmaceutical Relevant Inorganic Anions and Cations

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Jonathan R. Beck and Charles T. Yang; Thermo Fisher Scientific, San Jose, CA

Separation of Intact Monoclonal Antibody Sialylation Isoforms by ph Gradient Ion-Exchange Chromatography

NISTmAb characterization with a high-performance RP chromatography column

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Nano LC at 20 nl/min Made Easy: A Splitless Pump Combined with Fingertight UHPLC Nano Column to Boost LC-MS Sensitivity in Proteomics

High-Throughput Oligonucleotide Analysis on a Small Particle Pellicular Anion-Exchanger

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

MAbPac SCX-10 Columns

MAbPac SCX-10 Column for Monoclonal Antibody Variant Analysis and Characterization

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

for water and beverage analysis

mab and ADC Analysis Shanhua Lin, Ph.D. The world leader in serving science

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Chromatography Column Performance and Data Analysis Success Guide. Hints and Tips for Better Purifications

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

Determination of Manganese in Brine ( 30% NaCl)

Parallel LC with Capillary PS-DVB Monolithic Columns for High-Throughput Proteomics

MAbPac RP Column. High-performance reverse phase chromatography column for monoclonal antibody analysis

Columns for Biomolecules BioLC Column Lines

Application Note. Authors. Abstract. Biopharmaceuticals

Using the NISTmAb reference standard to demonstrate a simple approach to charge variant analysis

columnsi o n P a c C S 1 6 C a t i o n - E x c h a n g e C o l u m n

Analysis of Monoclonal Antibodies and Their Fragments by Size-Exclusion Chromatography Coupled with an Orbitrap Mass Spectrometer

Minimizing Carbon Dioxide Contamination in Anion Reagent-Free Ion Chromatography

Thermo Scientific Dionex ICS-900 Ion Chromatography System

New Developments in Capillary Ion Chromatography Systems with Electrochemical Detection and Their Applications

Application Note USD Purification of Mouse IgM from Cell Culture Supernatant by Cation Exchange Chromatography on CM Ceramic HyperD F Sorbent

Thermo Scientific. MAbPac HIC-10. Product Manual. P/N: June Part of Thermo Fisher Scientific

Highlighted Capillary IC Applications

Nuvia HR-S Strong Cation Exchange Media Instruction Manual

Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters Using a Compact Ion Chromatography System

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

HyperCel STAR AX Ion Exchange Sorbent

Chromatographic Workflows for Biopharmaceutical Characterization

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Thermo Scientific EASY-nLC 1000 System. Effortless, split-free nanoflow UHPLC Top performance in LC/MS

Determination of Inorganic Anions in Acid Rain Using a Dedicated High-Pressure Capillary Ion Chromatography System

Use of ScreenExpert RoboColumns u

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Get Your Fill. A full line of empty chromatography columns and accessories. Protein Purification

ION EXCHANGE KIT FOR MAB SEPARATIONS

SEC-MS with Volatile Buffers for Characterization of Biopharmaceuticals

A universal chromatography method for aggregate analysis of monoclonal antibodies

Thermo Scientific EASY-Spray Technology. Plug-and-spray with. State-of-the-art performance

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Thermo Scientific BioLC Columns. Monoclonal antibody. characterization

Monitoring Monoclonal Antibody Heterogeneity by Cation-Exchange Chromatography

Determination of 1,4-Dioxane in Drinking Water by Gas Chromatography/Mass Spectrometry (GC/MS) with Selected Ion Monitoring (SIM)

Claudio De Nardi, 1 Marta Kozak, 2 David Kasper 3 1. Thermo Fisher Scientific, Dreieich, Germany; 2 Thermo Fisher Scientific, San Jose, CA (USA); 3

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION

Q and S HyperCel Sorbents

[ Care and Use Manual ] Waters AccellPlus QMA and CM Bulk Media. I. calculating bulk media needs. II. packed column use. IIi.

Extraction of Phthalates from Solid and Liquid Matrices

Protein purification and bioprocessing MINIATURE PARALLEL AUTOMATED

High Throughput Sub-4 Minute Separation of Antibodies using Size Exclusion Chromatography

Identification of RNA Linkage Isomers by Anion-Exchange Purification with ESI-MS of Automatically-Desalted Phosphodiesterase-II Digests

columns P r o P a c H I C C o l u m n S o l u t i o n s f o r P r o t e i n A n a l y s i s

ANALYTICAL STANDARDS AND REAGENTS

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Direct Carbohydrate Analysis in Beverages and Foods Using Pulsed Amperometric Detection or Charged Aerosol Detection

Transcription:

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis Shanhua Lin, Julia Baek, and Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA

Overview Purpose: Evaluate the loading capacity, elution ph, and the throughput using linear ph gradient separation method for MAb variant analysis. Methods: A linear ph gradient from ph 5.6 to ph 1.2 is generated over time by running a linear pump gradient from 1% Thermo Scientific CX-1 ph Gradient Buffer A (ph 5.6) to 1% CX-1 ph Gradient Buffer B (ph 1.2). Online monitoring of the mobile phase ph value confirmed that a linear ph gradient was achieved. Results: 1. Linear UV response with up to 3 µg of protein loading; 2. The elution ph values of MAbs are in linear relationship with their corresponding pi values; 3. a fast separation of MAb charge variants is achieved in a 1-min cycle time. Introduction Recombinant monoclonal antibodies (MAbs) can be highly heterogeneous due to modifications such as sialylation, deamidation and C-terminal lysine truncation. Salt gradient cation exchange chromatography has been used with some success in characterizing MAb charge variants. However, additional effort is often required to tailor the salt gradient method for an individual MAb. In the fast-pace drug development environment, a fast and robust platform method is desired to accommodate the majority of the MAb analyses. We recently introduced a cation-exchange ph gradient buffer system which meets the fast and robust platform method requirement (ref. 1) This buffer system consists of a low-ph buffer A at ph 5.6 and a high-ph buffer B at ph 1.2. A linear ph gradient from ph 5.6 to ph 1.2 is generated over time by running a linear pump gradient from 1% buffer A to 1% buffer B. Using various MAbs with pi values ranging from 7 to 1, we demonstrated that the linear ph gradient method separates charge variants consistently. The loading capacity on a Thermo Scientific MAbPac SCX-1 column when running ph gradient is investigated by injecting increasing amount of protein standards. The study shows that there is a linear signal response up to 3 µg of protein loading. Furthermore, a fast separation of charge variants is achieved in a 1-min cycle time using 2 ml/min flow rate on a MAbPac SCX-1, 5 µm, 4 5 mm column. Time (minutes) 1 1 31 31 34 34 4 Table 2. A 15 min linear gr cation exchange columns from ph 5.6 to ph 1.2. Time (minutes) 1 1 16 16 17 17 2 F F Methods Sample Preparation: All standard proteins were purchased from Sigma-Aldrich. Monoclonal antibodies was a gift from a local biotech company. Proteins and MAb were dissolved in deionized water. Columns and Buffers MAbPac SCX-1, 1 µm, 4 25 mm (P/N 74625) MAbPac SCX-1, 5 µm, 4 5 mm (P/N 78656) CX-1 ph Gradient Buffer A (ph 5.6), 125 ml (P/N 83273) CX-1 ph Gradient Buffer B (ph 1.2), 125 ml (P/N 83275) Time (minutes) 8.5.5 8 8 8.5 8.5 1 F Liquid Chromatography HPLC experiments were carried out using an Thermo Scientific Dionex UltiMate 3 BioRS System equipped with: SRD-36 Membrane Degasser DGP-36RS Biocompatible Rapid Separation Pump TCC-3SD Thermostated Column Compartment with two biocompatible 1-port valves WPS-3TBRS Biocompatible Rapid Separation Thermostated Autosampler VWD-34RS UV Detector equipped with a Micro Flow Cell PCM-3 ph and Conductivity Monitor 2 A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Preparation of Eluents Eluent A and B each was prepared by simply diluting the corresponding 1 X CX-1 ph Gradient Buffer 1 fold using deionized water. Gradients The linear ph gradient was generated by running a linear gradient from 1% eluent A (ph 5.6) to 1% eluent B (ph 1.2). For ph gradient analysis carried out on the MAbPac SCX-1, 1 µm, 4 25 mm columns, the gradient method in Table 1 was used. For ph gradient analysis carried out on the MAbPac SCX-1, 5 µm, 4 5 mm columns, the gradient method in Table 2 or Table 3 was used. All methods cover the ph range from ph 5.6 to ph 1.2. Table 1. A 3 min linear gradient method for the MAbPac SCX-1, 1 µm, 4 25 mm, cation exchange columns. Total run time is 4 min. The linear ph range covers from ph 5.6 to ph 1.2. Time (minutes) Flow rate (ml/min) %A %B 1 1 1 1 31 1 1 1 31 34 1 1 34 4 1 1 Table 2. A 15 min linear gradient method for MAbPac SCX-1, 5 µm, 4 5 mm, cation exchange columns. Total run time is 2 min. The linear ph range covers from ph 5.6 to ph 1.2. Time (minutes) Flow rate (ml/min) %A %B 1 1 1 1 16 1 1 1 16 17 1 1 17 2 1 1 FIGURE 2. Plots of peak area an plotted on the primary Y-axis and t lentil lectin; (b) trypsinogen ; (c) ri Table 3. A 7.5 min linear gradient method for MAbPac SCX-1, 5 µm, 4 5 mm, cation exchange columns. Total run time is 1 min. The linear ph range covers from ph 5.6 to ph 1.2. (c) Time (minutes) Flow rate (ml/min) %A %B 8.5 2 1.5 8 2 1 1 8 8.5 2 1 8.5 1 2 1 Results The linear ph gradient was achieved by employing a multi-component buffer system containing multiple zwitterionic buffer species with pi values ranging from 6 to 1. Eluent A was titrated to ph 5.6 and eluent B was titrated to ph 1.2. In this ph range, each buffer species was either neutral or negatively charged. Therefore they were not retained by cation exchange column stationary phase and served as good buffers for the mobile phase and the stationary phase. The separation of proteins with different pi values by ph gradient was demonstrated in Figure 1. The protein mixture contained lentil lectin with three isoforms of lectin-1 (pi 7.8), lectin-2 (pi 8.), lectin-3 (pi 8.2), trypsinogen (pi 8.7), ribonuclease A (pi 9.3), and cytochrome C (pi 1.2). The concentration of these proteins were 3 mg/ml, 2 mg/ml, 3 mg/ml and 2 mg/ml respectively. Figure 1 showed the multiple UV traces of chromagrams recorded from a series injections of the protein mixture at 2 µl, 4 µl, 8 µl, 16 µl, 32 µl, 5 µl, and 1 µl. The peak area and peak width at half height (PWHH) were plotted against the sample loading in Figure 2a, 2b, 2c and 2d for lentil lectin-1, trypsinogen, ribonuclease A, and cytochrome C respectively. Trypsinogen, ribonuclease A, and cytochrome c exhibited very linear response up 1 µl of sample loading while lentil lectin-1 showed linear response up to 5 µl of sample loading. The separation of these proteins maintained throughout the range of 2 µg to 1, µg total protein loading. Thermo Scientific Poster Note PN2911_WCBP214_E_2/14S 3

%A %B 1 1 1 1 1 Pac SCX-1, 5 µm, 4 5 mm,. The linear ph range covers %A %B 1 1 1 1 1 FIGURE 1. Chromatogram of a protein mixture separated using a 3-min linear ph gradient on a MAbPac SCX-1, 1 µm, 4 25 mm column. Protein names are labeled for each peak. The protein concentrations in the sample mixture were: lentil lectin, 3 mg/ml; trypsinogen, 2 mg/ml; ribonuclease A, 3 mg/ml; cytochrome C, 2 mg/ ml. An increasing amount of samples were loaded onto the column using the following injection volumes: 2 µl, 4 µl, 8 µl, 16 µl, 32 µl, 5 µl, and 1 µl. The is colored in blue. 6 Lentil lectin-1 Cytochrome C 1.5 5 1. 9.5 4 9. Lentil lectin-2 8.5 3 Trypsinogen 8. Lentil lectin-3 7.5 2 Ribonuclease A 7. 1 6.5 6. 5.5-5 5. 2 4 6 8 1 12 14 16 18 2 22 24 26 28 3 32 34 36 38 Peak Lentil Lectin-1 1.2 9.18 8.16 7.14 6.12 5.1 4.8 3.6 2.4 1.2 1 2 3 4 FIGURE 2. Plots of peak area and PWHH versus sample loading. Peak area is plotted on the primary Y-axis and the PWHH is plotted on the secondary Y-axis. lentil lectin; (b) trypsinogen ; (c) ribonuclease A; (d) cytochrome C. (b) Peak Trypsinogen 1.5 9.45 8.4 7.35 6.3 5.25 4.2 3.15 2.1 1.5 5 1 15 2 25 2 18 16 14 12 1 8 6 4 (c) 5 Ribonuclease A.5 (d) 2 Cytochrome C.5 2 %A %B 1 1 1 1 Peak 45.45 4.4 35.35 3.3 25.25 2.2 15.15 1.1 5.5 1 2 3 4 Peak 18.45 16.4 14.35 12.3 1.25 8.2 6.15 4.1 2.5 5 1 15 2 25-2. 5. 1. 1 FIGURE 3. A graph plotting the measured ph values for six protein component peaks as a function of the corresponding pi value. The measured ph values of all six components were exported from the same experiment shown in Figure 1. 1.5 1 9.5 y = 1.6923x - 7.2914 R² =.9929 Cytochrome C Measured ph value 9 8.5 8 7.5 7 Trypsinogen Ribonuclease A Measured ph value Linear (Measured ph value) 6.5 6 Lectin-3 Lectin-2 Lectin-1 5.5 7.5 8.5 9.5 1.5 pi value 4 A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Linear correlation of elution ph versus protein pi value An analysis was performed to show that there is a correlation between the elution ph versus the corresponding pi values of the protein components. Figure 3 is a graph comparing the measured ph values for six protein component peaks in Figure 1 as a function of the corresponding pi values. The measured ph values for the six protein component peaks exhibited a strong linear correlation to the literature based pi values, with R 2 value at.9929. Since MAb molecules within the IgG1 class share most of the protein sequence, we expect to see a more linear correlation of the MAb elution ph versus their pi. Figure 4 showed ph gradient separation of charge variants from six MAbs with pi values ranging from 7 to 1. Figure 5 is a plot of the elution ph of each MAb major variant versus the MAb pi value. The linear fit yielded a R 2 value at.9988. Thus, after a calibration procedure, this example supports the fact that linear regression coupled with the gradient method described here can be used to estimate the pi of a MAb based on the peak retention time and elution ph. ample loading. Peak area is on the secondary Y-axis. ytochrome C. FIGURE 4. Chromatogram of six MAbs separated using a 3-min linear ph gradient on a MAbPac SCX-1, 1 µm, 4 25 mm column. The UV traces are corresponding to the MAbs with the following pi : 7.2 (black), 7.6 (blue), 7.8 (pink), 8.3 (brown), 9. (green), and 1. (purple). The is colored in blue. 2 18 16 1.5 1. 9.5 14 12 1 8 6 4 2 9. 8.5 8. 7.5 7. 6.5 6. 5.5-2 5.. 5. 1. 15. 2. 25. 3. 35. 4. FIGURE 5. A graph plotting the elution ph values for six MAbs as a function of the corresponding pi value. The measured ph values of the major variant from all six MAbs were exported from the same experiment shown in Figure 4. 1 MAb Elution ph value 9.5 9 8.5 8 7.5 7 y = 1.183x - 1.637 R² =.9988 MAb Elution ph value Linear (MAb Elution ph value) 6.5 6 6.5 7.5 8.5 9.5 1.5 MAb pi value PO2911_E 1/14S Thermo Scientific Poster Note PN2911_WCBP214_E_2/14S 5

Fast ph Gradient Separation The ph gradient method is fast and rugged. Figure 6 showed ph gradient runs on a MAbPac SCX-1, 5 µm, 4 5 mm column. Using 1 ml/min flow rate, MAb variants separation can be achieved within 15 min with a total run time of 2 min (figure 6a). Using 2 ml/min flow rate, MAb variants separation can be achieved within 7.5 min with a total run time of 1 min (figure 6b). In both cases, the linearity of the ph gradient maintained. FIGURE 6. Fast MAb variant separation using ph gradient on a MAbPac SCX-1, 5 µm, 4 5 mm column. 15-min gradient method; (b) 7.5-min gradient method. The MAb sample concentration was 5 mg/ml. 25 2 15 1 5 1.5 9. 8. 7. 6. -5 5.. 2. 4. 6. 8. 1. 12. 14. 16. 18. 2. 14 12 1 8 6 4 (b) 11. 1. 9. 8. 7. 2 6. -2 5.. 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. Conclusions Using ph gradient method, linear signal response is achieved with up to 3 µg protein loading; Using ph gradient method, the elution ph values of MAbs are in linear relationship with their corresponding pi values; Using ph gradient method, fast separation of MAb charge variants is achieved within a 1-min cycle time. References 1. Lin, S., Baek, J., Decrop, W., Rao, S., Agroskin, Y., and Pohl, C. Development of a Cation-Exchange ph Gradient Separation Platform. Presented at 39 th International Symposium on High Performance Liquid Phase Separations and Related Techniques, Amsterdam, The Netherlands, June 16-2, 213. PO2911_E 1/14S 6 A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

www.thermofisher.com 216 Thermo Fisher Scientific Inc. All rights reserved. Sigma is a registered trademark of Sigma-Aldrich Co. LLC. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa +43 1 333 5 34 Australia +61 3 9757 43 Austria +43 81 282 26 Belgium +32 53 73 42 41 Brazil +55 11 3731 514 Canada +1 8 53 8447 China 8 81 5118 (free call domestic) 4 65 5118 Denmark +45 7 23 62 6 Europe-Other +43 1 333 5 34 Finland +358 9 3291 2 France +33 1 6 92 48 Germany +49 613 48 114 India +91 22 6742 9494 Italy +39 2 95 591 Japan +81 6 6885 1213 Korea +82 2 342 86 Latin America +1 561 688 87 Middle East +43 1 333 5 34 Netherlands +31 76 579 55 55 New Zealand +64 9 98 67 Norway +46 8 556 468 Russia/CIS +43 1 333 5 34 Singapore +65 6289 119 Sweden +46 8 556 468 Switzerland +41 61 716 77 Taiwan +886 2 8751 6655 UK/Ireland +44 1442 233555 USA +1 8 532 4752 PN2911_E 7/16S