Fire Pattern Repeatability: A Study in Uncertainty

Similar documents
A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

Burtin Polymer Laboratories 2 SwRI Project No e[1]

An Applied Engineering Research Project to Evaluate Radiant Heat Exposure of Exterior Walls

REQUESTED BY : Atlas Roofing and Flooring PO Box Queenswood CONTRACT No : FTC12/088. AUTHOR(S) : K. van Dyk. DATE : 13 September 2012

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

Fire Testing Laboratory

Deer Ridge Consulting, Inc.

FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT

Fire Performance of Laminated Veneer Lumber (LVL)

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

Evaluating Fire Performance of Facade Assemblies Using ANSI/FM 4880

7/25/2011. THERMAL BARRlERS AND IGNITION BARRIERS. What is a Thermal Barrier? Thermal Barrier Code

The Suitability of Fire-Field Modelling for Enclosure Fires involving Complex Solid Fuel Loads. STIFF Meeting Sept 2006 Stuart Winter

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 550 Fast Cure + AC63"

Fire Performance Concerns of Lightweight Engineered Lumber (LEL) Systems

Charring rate of intumescent fire protective coated Norway spruce (Picea abies L.)

Intumescent Coatings and Spray Polyurethane Foam

On July 22, 1999, a six inch

Fire Considerations. Combustible Cladding and Components Of Exterior Walls and Curtain Walls. APEGBC/BCBEC Seminar, April

Experimental Study on Fire Characteristics of Building External Thermal Insulation Composite Systems under Corner Wall

HPW Protocol Reference Manual

ICC xx Standard for Spray-applied Polyurethane Foam Plastic Insulation

WOOD & FIRE SAFETY. 3 rd International Scientific Conference

NRC Research Update on Mid-Rise Wood Construction. Joseph Su Principal Research Officer, Fire Safety

Test Summaries: AWP 1818 & 3030

Executive summary. Fire Hazards of Exterior Wall Assemblies Containing Combustible Components v

Single Wythe CMU Meeting the Energy Code

REPORT NUMBER: SAT-001 ORIGINAL ISSUE DATE: March 23, 2010 REVISED DATE: NA

An Experimental Study of the Effect of Thermal Radiation Feedback. on the Room-Burning Behaviour of Horizontal Slabs of Polyurethane

Effect of Rack Mounted Photovoltaic Modules on the Fire Classification Rating of Roofing Assemblies Phase 2

International Code Council ICC XX Public Input Agenda based on input received on Initial Draft

EMRGENCY EXPRESS TERMS BY THE CALIFORNIA DEPARTMENT OF FORESTRY (CDF) & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL (SFM)

FIRE TEST REPORT FH 5636

SHOWER WALLS S.A. DE C.V. FIRE TEST REPORT

First Revision No NFPA [ Section No ]

Originally Issued: 11/06/2017 Valid Through: 11/30/2018

Let s begin, your first session, module 1, which will cover chapter 2, definitions and a portion of chapter 3, building planning.

NFPA 285: Assembly Test of Exterior Walls with Combustible Components. Herman Lopez DuPont Commercial Account Manager

Report on First Revision June 2014 NFPA 5000

BRE Global Classification Report

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF BAILEY INTERIORS EXPOSED NU SHADEX PERFORATED PLASTER CEILING TILES (600MM

CommercialComplete Wall System

RESOLUTION MSC.90(71) (adopted on 21 May 1999) ADOPTION OF AMENDMENTS TO THE STANDARD FOR QUALIFYING MARINE MATERIALS FOR HIGH-SPEED CRAFT AS

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Combustible Exterior Wall Cladding Systems: An ICC Perspective

Fire Resistance of Wood-Framed Exterior Walls: The Effect of An External Air Cavity and External Insulation

International Code Council. ICC XX Public Input Agenda based on input received on Initial Draft

FIRE FORENSICS: CLAIMS & EVIDENCE

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

combustibility behaviour of insulation products

ICC xx. Standard for Spray-applied Polyurethane Foam Plastic Insulation Public Input Draft #2

Rak Fire simulation

When R-Value Doesn t Measure Up

Originally Issued: 08/03/2017 Revised: 02/01/2019 Valid Through: 08/31/2019

Session: Foam Plastic Insulation Exterior Wall Fire Safety

Architecture Building, Delft University of Technology: Data Collection and Preliminary Analyses

Port of Anchorage Fuel Terminal. Fire Hazard Calculations. 100% Submittal

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

BRE Global Assessment Report

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF BAILEY INTERIORS CELL AIR 1200MM

DICKSON COATINGS FIRE TEST REPORT

Engineering Analysis of NFPA 285 Tested Assemblies

Exterior Wall Systems NFPA 285

INTERIOR FINISHES CHAPTER 8

ASTM E 648 Test Method. 5/8" Walnut Engineered Wood Flooring

Moisture risks of passive retrofitting one town house for the adjacent conventional neighboring structures

First Revision No NFPA [ Section No ]

FIRE RATINGS. European Oak

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Energy Code Math for Commercial Walls: How polyiso continuous insulation can help

COMposite super-structures for large PASsenger Ships

Heat Release Rate of Wood-Plastic Composites

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Report to: Plumberex Specialty Products, Inc. Pipe Insulation and Fire Safety

Construction Standards PAGE

Impact of NFPA 285 on Air Barrier Specification and Design

ABAA Light density open cell semi rigid spray polyurethane foam Material Specification

The experimental programme for this stage of the project has been undertaken in three phases:

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide

International Fireproof Technology, Inc.

BS :2005 test on a Kingspan Benchmark External Wall Insulation System

ICC xx Standard for Spray-applied Polyurethane Foam Plastic Insulation

DICKSON COATINGS FIRE TEST REPORT

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

INTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL

ASSESSMENT REPORT. EWFA Report No: b 3. Report Sponsor: Timberwood Panels Pty Ltd National Blvd Campbellfield VIC 3061

Phenolic Exterior Wall Cladding

BRE Global Test Report

Builder's Manual for Ortal Fireplaces

Originally Issued: 02/01/2019 Valid Through: 02/28/2020

ALPOLIC /fr for External Cladding

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

ROXUL SAFE Applications Guide

FLAME RETARDANT TREATED WOOD PRODUCTS

International Journal on Engineering Performance-Based Fire Codes, Volume 5, Number 4, p , 2003

TYPICAL BEARING WALL FRAMING

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Transcription:

Fire Pattern Repeatability: A Study in Uncertainty Daniel Madrzykowski National Institute of Standards and Technology Gaithersburg, MD., USA Charles Fleischmann, PhD Department of Civil and Natural Resources Engineering University of Canterbury Christchurch, NZ

Introduction Technical Approach Overview Fuel Choice Fire Source Characterization Repeatability HRR Flame Height Fire Pattern Experiments Wall Construction Pattern repeatability Summary

Introduction Interpretation of burn patterns is one of the basic methods of determining the area of origin Currently there is limited scientific literature on the development of burn patterns. much more research is needed on the natural variability of burn patterns Strengthening Forensic Science in the United States: A Path Forward, Committee on Identifying the Needs of the Forensic Sciences Community ; Committee on Applied Theoretical Statistics, National Research Council, National Academy of Sciences, 2009.

Literature Review Significant areas of research have been completed on Flame heights and fire plumes The thermal transfer to a wall or corner from a fire Thermal degradation of gypsum wallboard

Gaps Most of the heat transfer research has been done with laboratory fuels and non-combustible walls No correlations between the thermal degradation from a fire and the resulting fire pattern. No measure of repeatability for fire patterns under a given set of conditions. No validation of a computer model s ability to reasonably simulate a fire pattern

Technical Approach Repeatability of the Fire Patterns Full Scale Source Fire Characterization, 3 different fuels Repeatability of Heat Release Rate, Flame Height, Free Burn, Non-combustible Target Wall, Instrumented Gypsum Board Wall Fire Pattern Repeatability Painted 12.7 mm thick gypsum wallboard will serve as the target fuel/surface for exposure to the fires Variations in wall construction (insulation) will be examined Several fuel positions relative to wall and corner examined Conduct replicates. Patterns recorded manually, photographically and with video. Analyze height, width, shape and area of each pattern

Technical Approach (continued) Simulating Fire Patterns with FDS Bench Scale Experiments to generate input data for FDS Cone Calorimeter Data HRR, time to ignition Flooring Radiant Panel Experiments critical heat flux Thermal conductivity Specific heat FDS/Smokeview Modeling (In Progress) Comparisons with full scale results

Source Term Characterization Experimental Arrangement

HRR System Calibration

Source Fire Characterization Heat Release Rate Flame/Plume Temperatures Total Heat Flux and temperature at target wall surface Burner/pan/fuel size 0.305 m x 0.305 m x 0.076m Natural gas Gasoline Polyurethane foam

Natural Gas

Heat Release Rate Natural Gas

Gasoline

Heat Release Rate - Gasoline

Polyurethane Foam

Heat Release Rate Polyurethane Foam

Video Frame Analysis

Video Frame Analysis

Flame Heights Fuel Mean H f (m) Range H f (m) Natural Gas 0.70 0.40 to 0.98 Gasoline 0.84 0.52 to 1.1 Polyurethane Foam 0.46 0.30 to 0.78

Fire Pattern Experimental Arrangement

Line of Demarcation Definition Fire effects that form patterns from DeHaan Surface deposits Surface thermal effects Charring Penetration Consumption DeHaan, John D., Kirk s Fire Investigation, Sixth Edition, Pearson Prentice Hall, Upper Saddle River, NJ., 2007.

Penetration and Consumption of Paint and Paper

Patterns from Natural Gas Fire 0.69 m 0.74 m 0.89 m

Patterns from Gasoline Fires 0.61 m 0.83 m 0.89 m

Patterns from PUF Fires 0.25 m 0.30 m 0.20 m

Normal Distribution Standard Deviation Diagram based on original graph by Jeremy Kemp

Fuel Comparison Fire Pattern Dimensions Values presented with 95% confidence limits Fuel (number of experiments) Height (m) Width (m) Height @ Max Width (m) Area (m 2 ) Natural Gas (10) 0.74 + 16% 0.24 + 25% 0.41 + 17% 0.15 + 33% Gasoline (12) 0.83 + 18% 0.28 + 32% 0.44 + 41% 0.17 + 25% Polyurethane Foam (10) 0.24 + 50% 0.28 + 29% 0.04 + 60% 0.05 + 57%

Impact of Construction on Pattern Examine three types of wall construction 12.7 mm thick gypsum on front of wood frame 12.7 mm thick gypsum on front and rear of wood frame (typical interior wall arrangement) 12.7 mm thick gypsum on front and rear of wood frame with R-13 fiberglas insulation filling the wood frame void space (representing an exterior wall arrangement) Examine resulting patterns for changes in height, width, area, and shape.

Fire Pattern Comparison by Wall Type OPEN CLOSED INSULATED

Comparison of Fire Pattern as a Function of Wall Construction Type. Values presented with 95% confidence limits. Fuel (# of Tests) Wall Type Max Height (m) Max Width (m) Height @Max Width (m) Area (m 2 ) Nat. Gas (10) Nat. Gas (10) Nat. Gas (10) Gasoline (12) Gasoline (10) Gasoline (10) Open 0.74 + 16% 0.24 + 25% 0.41 + 17% 0.15 + 33% Closed 0.74 + 8% 0.24 + 7% 0.43 + 7% 0.14 + 6 % Insulated 0.71 + 14% 0.23 + 17% 0.42 + 17% 0.15 + 14% Open 0.83 + 18% 0.28 + 32% 0.44 + 32% 0.17 + 24% Closed 0.80 + 13% 0.29 + 14% 0.44 + 14% 0.17 + 24% Insulated 0.82 + 11% 0.25 + 32% 0.40 + 32% 0.13 + 30%

Mean Flame Heights vs Fire Pattern Heights Fuel Mean H f (m) Range H f (m) Pattern H (m) Natural Gas 0.70 0.40 to 0.98 0.74 + 16% Gasoline 0.84 0.52 to 1.1 0.83 + 18% Polyurethane Foam 0.46 0.30 to 0.78 0.24 + 50%

Summary from Experiments Repeatability of HRRs of Natural Gas Fires similar to uncertainty of calorimeter HRRs of Gasoline and Polyurethane Foam were not as repeatable. Height of the fire patterns from the fires with the higher HRR (Natural Gas and Gasoline) were similar to the median flame height Uncertainties of < 18% on fire pattern height for Natural Gas and Gasoline Uncertainties of <33% for other pattern dimensions for Natural Gas and Gasoline

Future Comparisons/Validation? Examine computer based pattern analysis with image processing software. Each program is a model that brings uncertainties based on choices of input parameters Compare FDS simulation with field measures (photos) from pattern experiments. FDS modeling is dependent on computational grid cell size choice and input parameters from experiments with uncertainties Compare FDS with point measures (temperature and heat flux) from instrumented wall experiments. Uncertainties for temperature and heat flux measurements are in the range of 10 to 15%.

Questions? madrzy@nist.gov