ALUBOX Series Junction boxes in IP66 aluminium alloy

Similar documents
LIT-EX Series Fluorescent armours for applications in potentially explosive atmospheres

Selection PHOTOVOLTAIC APPLICATIONS. AC/DC Isolators for solar photovoltaic

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Field case for temperature transmitter Model TIF11

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Hazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb)

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Supporting bracket. Cooling fins. Internal reflector. Shock-resistant tempered glass. Ex e terminal housing for a quick connection

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

79 Trenton Avenue Frenchtown, NJ Tel: (908) Fax: (908)

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages.

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

MIT. Lighting to save

High performance JET High efficiency outdoor projector for 2000W metal halide lamps. Suitable for lighting of big areas and sport stadiums.

PRODUCT RANGE CABLE GLANDS

ATEX The legislation ATEX 94/9/EC (95) European Directive 23 March Mandatory 30/6/2003. Fläkt Woods Group

PYROS. Código: FT-PY01-I Revisión: 1 1. TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white REFLECTOR

ALUMAX. High Amperage Power Solutions

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

Ground-recessed uplighters for high pressure discharge lamps

MXBS SOCKET-OUTLET COMBINATION BOXES 63 A TECHNICAL FEATURES

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Protect people and preserve equipment. Universal Enclosures

Ex d. Cooling fins. 4 Joule shock resistant borosilicate glass globe Internal connection terminal box. Stainless steel protective guard A.14 ED.

Coating Specifications

Facette Wall luminaires for discharge lamps or incandescent lamps

- Zone 1, 2, 21, 22 - Aluminium enclosures - Choice of 18 sizes - IP66 - IK10 ED.2017

Product Datasheet. Fire Hose Reel (Page 3)

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

Ensto Industrial Solutions. Enclosing solutions. for the solar energy industry

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

SafeSite LED Bulkhead / Wallpack - ATEX / IECEx for Indoor and Outdoor Industrial Applications

Subject: Guidance on Corrosion Assessment of Ex Equipment

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

IP 66 TECHNICAL DATA SHEET ART. S FOCUS

Mounted Enclosures Steel Powder-Coated

Nightspot High performance floodlights for discharge lamps and LEDs

E-Xtreme. Titanium plasma protected. E-Xtreme hours in salt spray tests. series. iwww.ilme.com

QGO Oxygen Sensor. Building Technologies HVAC Products

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

BOYLE 100. Compact impervious luminaire for ATEX zones with harsh environment. Zones 2, 21, 22

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

Differential pressure

Barrial Korridor. Aluminium escape, rescue and maintenance access routes

Index & Cam Plungers +44 (0) / / A05.1 Index & Cam Plungers 1

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

Heating Cables DATASHEET

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters

Flameproof enclosures

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Temperature sensors for automotive applications

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

new Saturno LED - suspension

Our expertise your benefit. AE Available off the shelf.

AXLELINE SERIES ELECTRONIC AXLE SCALES.

Certificate of Compliance

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

digitalyewflo Series Vortex Flowmeter Installation Manual

NEW PRODUCTS PREVIEW. Cool, stylish lighting of solids and spaces.

Roxtec Cable and Pipe Sealing Solutions

Perfect integration! >>> FLOOR BOXES. NEW floor boxes

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

SPECIFICATION SHEET JUNCTION BOXES

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Dimensions / Order Codes

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Cable junction boxes with intrinsic fire resistance and insulation integrity

OptiLine 70. Service Poles. Technical and Material data

Manual Actuator. S / SR / SP Levers. Type Series Booklet

EWL. Painted aluminium. body

EVL. Supporting bracket

Diaphragm pressure gauge

KS EXTENSIONS FOR CLEAN ROOMS

Over pressure Switching pressure difference (typical) Lower range Upper range

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

UFB. Floor Products. Floor outlet boxes. Content. UFB-700 and UFB-900, rectangular and square fl oor outlet boxes for dry premises Page 2

BARRIER BARRIER. quick installation. high quality collective side protection. ideal for escape routes. pleasing, unobtrusively design

Lighting to save. Jakelija: Tehdasvalo Oy

Clearly Solar. Installation Instructions. Solar Thermal Flat Plate Collector. Vertical On-roof mounting SHV

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

LIQUID METER TYPE FMO

Guide for selecting the right FIBOX enclosure

Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal On-roof mounting SRH 2.3

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

CANNON. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.

Select the basic design of your clamp assembly. A58.

Diaphragm seal with flange connection Cell-type with extended diaphragm Model

LEADERS IN PROCESS ANALYSIS AND CONTROL. Safety Solu ons. for Industrial Facili es

630 PHOENIX CONTACT. Courtesy of Steven Engineering, Inc - (800)

Thermocouple for Flue Gas Temperature Measurements,

ALPHAIR PNEUMATIC ACTUATORS EXTERNAL ADJUSTMENT NEW "RE"SERIES

Certificate of Compliance

CONDUIT ACCESSORIES AND FIXINGS

Transcription:

UBOX Series Junction boxes in IP aluminium alloy

> ENCLOSURES IP UBOX Series UBOX-EX Series Dimensions () Screw for attaching cover Earthing screws Weight (Kg) 00 x 00 x 59 n 2 M5x0 n M4x 0,290 /32 53.00 53.9000 40 x 5 x 0 n 4 M5x n M4x 0,390 /24 53.0 53.900 x 42 x 4 n 4 M5x n M4x 0,4 / 53.02 53.9002 92 x 8 x 80 n 4 M5x n M4x 0,920 /2 53.03 53.9003 253 x 27 x 93 n 4 Mx20 n M4x,430 / 53.04 53.9004 34 x 24 x 22 n 4 Mx20 n M4x 2,23 /2 53.05 53.9005 40 x 35 x 53 n 4 Mx20 n M4x 3,8 53.07 53.9007 - Enclosure and cover in die-cast aluminium. - Externally varnished. - With stainless steel screws for attaching cover and self-tapping zinccoated steel screws for earthing the enclosure and cover. = Counter-sunk head screw. = Flat head screw. UBOX Series > MOUNTING PLATES > DIN RAIL KIT For enclosures () 00 x 00 x 59 Screw for attaching cover Thickness () Weight (Kg) 40 x 5 x 0 n 4 M4x,5 0,40 /40 53.0 x 42 x 4 n 4 M4x,5 0,23 /20 53.02 92 x 8 x 80 n 4 M4x,5 0,245 /20 53.03 253 x 27 x 93 n 4 M4x,5 0,423 /0 53.04 34 x 24 x 22 n 4 M4x,5 0,2 /0 53.05 40 x 35 x 53 n 4 M4x 2,43 5 53.07 - Zinc-coated steel plate. - With zinc-coated steel self-tapping screws for attaching the plate. 53.020 53.02 53.022 53.023 53.024 53.025 53.027 Enclosures and covers in aluminium alloy with blank walls and covered. Holding seal in expanded EPDM, already mounted in place on the cover. Fixing to wall by brackets incorporated in the enclosure base.

UBOX Series > JUNCTION BOXES IN UMINIUM LOY (STANDARD USE) > REFERENCE STANDARDS EN 070-22 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Part 22: particular requirements for connecting boxes and enclosures. > VERSIONS > TECHNIC CHARACTERISTICS Enclosure IP Mounting plates DIN rail kit Protection degree: Operating temperature according to the reference standard: Max. operating temperature (Short period): Material: IK degree at 20 C: Cable inlets: DIN rail fixing: Colour: IP -25 C +0 C -40 C +90 C Aluminium alloy IK08 Blank sides Yes Grey R 900 with metallic pigments > BEHAVIOUR WITH CHEMIC AND ATMOSPHERIC AGENTS Saline solution Acids Bases Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Mineral oil UV rays For specific substances please contact our technical service.

> JUNCTION BOXES IN UMINIUM LOY (FOR ZONE 22) > REFERENCE STANDARDS EN 24-0 Electrical apparatus for use in the presence of combustible dust. Part 0: General requirements. EN 24- Electrical apparatus for use in the presence of combustible dust. Part : Protection by enclosures td. EN 0079-0 Electrical apparatus for explosive gas atmospheres. Part 0: General requirements. - Suitable for outdoor use. - Supplied with enclosure earthing kit. - Use only non-sparking components and cable glands compliant with the ATEX directive. EN 0079-5 Electrical apparatus for explosive gas atmospheres. Part 5: Construction, test and marking of type of protection n electrical apparatus. > TECHNIC CHARACTERISTICS EX > VERSIONS Enclosure IP Mounting plates DIN rail kit ATEX Code: Type of EX protection: II 3GD Ex na II Ex td A22 IP T90 C U Operating temperature according to the reference standard: -20 C +0 C Maximum permissible surface temperature: T90 C Protection degree: IP Impact resistance: Low mechanical risk (4J). Material: Aluminium alloy IK degree at 20 C: IK08 Cable inlets: Blank sides DIN rail fixing: Yes Colour: R 7037 CE Certification type: SCAME ATEX 0U > BEHAVIOUR WITH CHEMIC AND ATMOSPHERIC AGENTS Saline solution Acids Bases Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Mineral oil UV rays For specific substances please contact our technical service.

> DIMENSIONS UBOX Series ENCLOSURES MOUNTING PLATES (Dimension in ) 53.0 53.02 53.03 53.04 53.05 53.07 40x5 x42 92x8 253x27 34x24 40x35 Box reference () I 22 47 5 20 254 349 L 97 23 24 72 20 20 M 07 2 53 88 238 333 N 98 2 53 98 248 53.9000 53.900 53.9002 53.9003 53.9004 53.9005 53.9007 53.00 53.0 53.02 53.03 53.04 53.05 53.07 32 24 2 2 A 00 40 92 253 34 40 External dimensions (with cover) External box dimensions Internal dimensions (with cover) Surface mounting points Useful height B 00 5 42 8 27 24 35 C 59 0 4 80 93 22 53 D 94 34 0 85 247 305 400 E 94 09 3 2 255 305 c 53 55 58 74 85 4 44 d 90 30 5 80 242 299 393 e 90 04 32 5 20 249 298 F 7,5 9 9 9 G 88 20 44 8 22 275 37 H 80 00 25 49 9 23 283 O X 45 48 4 75 03 27

ZP00488-GB-3 8 00340953 ScameOnLine www.scame.com export@scame.com SCAME PARRE S.p.A. VIA COSTA ERTA, 5 24020 PARRE (BG) ITY TEL. +39 035 705000 FAX +39 035 70322