SHAKING TABLE TESTS OF A BASE ISOLATED STRUCTURE WITH MULTI-STAGE SYSTEM

Similar documents
EXPERIMENTAL TEST OF ELASTOMERIC BEARINGS USED IN BASE ISOLATION

FINITE ELEMENT MODELLING OF ELASTOMERIC BEARINGS

THE BEHAVIOUR UNDER COMPRESSION OF ELASTOMERS USED IN BASE ISOLATION BEARINGS

BEHAVIOUR OF CONCRETE MASONRY UNITS IN COMPRESSION

INFLUENCE OF STIFFNESS ON THE TORSIONAL RESPONSE OF ONE STORY STRUCTURE

USING OF NORMALIZED EXPERIMENTAL CURVES IN MASONRY STRENGTHS ESTIMATION

OPTIMIZATION METHODS OF ENERGY DISSIPATIVE COLUMNS

OLD MASONRIES REHABILITATION. DAMAGED AND COATED STRUCTURES MADE WITH WEAK MORTARS

DYNAMIC ANALYSIS TO THE SEISMIC ACTION OF A BURIED WATER CONVEYANCE STRUCTURES

ISSUES FOR ACHIEVING AN EXPERIMENTAL MODEL CONCERNING BUBBLE DECK CONCRETE SLAB WITH SPHERICAL GAPS

IMPROVING STRUCTURAL RESPONSE OF WOOD BEAMS BY REINFORCING WITH CARBON FIBRE REINFORCED POLYMER ELEMENTS

COMPARATIVE STUDY RELATED TO FAILURE FORCE AND FAILURE MECHANISM BETWEEN REAL LIFE TEST AND 3-D FEM MODEL ON A HIGHWAY BEAM

NUMERICAL MODEL FOR STEEL CONCRETE COMPOSITE SLABS IN FIRE, CONSIDERING THE MEMBRANE EFFECT

REHABILITATION OF MASONRY BUILDINGS USING SEISMIC ISOLATION SYSTEMS IN THE BASE CASE STUDY

STRESS ANALYSIS OF MASONRY WALLS IN CASE OF LIMITED EXCAVATION FOR FOUNDATION UNDERPINNING

COMPRESSION STRENGTH TESTING FOR AUTOMOTIVE BRAKE PADS USED IN EARTHQUAKE ENERGY DAMPERS

35 m LARGE OPENING ROOF STRUCTURAL SYSTEM MADE OF HOT ROLLED AND COLD FORMED STEEL PROFILES

USE OF RENEWABLE ENERGY TO ENSURE THE THERMAL INDEPENDENCE FOR A LIVING BUILDING USING SOLAR HYBRID SYSTEMS

THE STRUCTURAL REHABILITATION OF A MASONRY BUILDING

THE FUTURE CONCRETE: SELF-COMPACTING CONCRETE

SOIL STRUCTURE INTERACTION IN CASE OF A WIND TURBINE

EXPERIMENTAL TESTS OF THIN-WALLED STEEL ROOF PROFILES

ASSPECTS CONCERNING THE IMPROVEMENT OF SOILS AGAINST LIQUEFACTION

DYNAMIC ANALYSIS BY NUMERICAL SIMULATION OF THE VARIATION OF THE HYDRAULIC PARAMETERS OF THE SOLENOID INJECTOR

STRUCTURAL RESPONSE OF COMPOSITE PULTRUDED ELEMENTS SUBJECTED TO SHEAR

INFLUENCE OF INFILL MATERIAL ON THE OVERALL BEHAVIOR OF A REINFORCED CONCRETE FRAME STRUCTURE

FAILURE MECHANISMS FOR ORTHODOX CHURCHES IN ROMANIAN SEISMIC AREAS

LABORATORY MEASUREMENTS OF WIND VELOCITY FIELD BEHIND WINDBREAK SCREENS

FLY ASH ADMIXTURE AND ITS INFLUENCE ON BELITIC TYPE CEMENT CONCRETE PERMEABILITY

NON-LINEAR ANALYSIS OF REINFORCED CONCRETE FRAMES WITH ATENA 3-D PROGRAM

THE IMPORTANCE OF THE SYSTEM FOR COLLECTION AND ELIMINATION OF WATER VAPOUR IN A FLAT ROOF STRUCTURE

BEHAVIOR OF MASONRY VAULTED STRUCTURES STRENGTHENED USING REINFORCED CONCRETE BEAMS ON TOP

INFILTRATION MODELING THROUGH AN EARTH DAM CASE STUDY

WORKABILITY OF STORABLE ASPHALT MIXTURES, MEASURING DEVICES

THE NECESSITY OF PERFORMING CURRENT MAINTENANCE WORK ON BUILDINGS

DIMENSIONAL OPTIMIZATION FOR SEGMENTED UNDERPINNING BASED ON THE STRUCTURAL RESPONSE

DECREASING SEISMIC EFFECTS OF STRUCTURES USING BASE ISOLATION SYSTEMS

THE INFLUENCE OF SOME COMPOSITION FACTORS ON THE BEHAVIOR OF MICRO-CONCRETES SUBJECTED TO MAGNESIAN AGRESSIVITY

PRECISION FORGING OF BEVEL GEAR WITH STRAIGHT TEETH

The influence of vertical seismic ground motion on structures with uplift

Shaking table experimental study on the base isolation system made of polymer bearings

STRUCTURAL AND DAMAGE ASSESSMENT OF AN HISTORICAL MASONRY CHURCH

PERFORMANCES OF THE CONCRETE MASONRY WITH RECYCLED WOOD CHIPS (I)

ACTUAL TRENDS IN THE CONCEPTION AND DESIGN OF PAVEMENTS FOR AIRPORT RUNWAY

RĂZVAN-ANDREI IERNUŢAN * and MARIA-NICOLETA ROMAN-PINTICAN

ANALYSIS OF FLOW INDUCED STRESS FIELD IN A FRANCIS TURBINE RUNNER BLADE

REINFORCED SOIL RETAINING STRUCTURES DOMAINS OF USAGE

ANALYSIS OF HYBRID POLYMERIC COMPOSITE-TIMBER BEAMS USING NUMERICAL MODELLING

USE OF STEELWORKS CRUSHED SLAG IN ASPHALT MIXTURES USED TO ROADS

ANALYTICAL AND EXPERIMENTAL STUDIES ON THE SEISMIC RESPONSE OF BASE ISOLATION SYSTEMS FOR ELECTRIC POWER EQUIPMENT

EFFECT OF CONFINEMENT ON BOND STRENGTH BETWEEN SELF-COMPACTING CONCRETE AND REINFORCEMENT

STRENGTHENING TECHNIQUES OF RC COLUMNS USING FIBRE REINFORCED POLYMERIC MATERIALS

RESEARCHES REGARDING AN INCREMENTAL FORMING PROCESS BY MEANS OF AN INDUSTRIAL ROBOT

REAL VALUE ESTIMATION FOR REINFORCED CONCRETE BUILDINGS

FLEXURAL STIFFNESS OF HYBRID WOOD - FIBRE REINFORCED POLYMER COMPOSITES ELEMENTS

COMPARATIVE ANALYSIS OF SEISMIC ISOLATED SYSTEMS IN BRIDGES

ANALYTICAL EVALUATION OF THE SEISMIC VULNERABILITY FOR MASONRY CHURCHES USING THE FINITE ELEMENT METHOD

NOTIONS OF SHARE FORCE RESISTANCE OF DOUBLE T THICK STEEL WELDED SHEETS WITH SINUSOIDAL WEBS PRODUCED IN ROMANIA

SEISMIC CALIFICATION OF ELECTRICAL AND I&C CABINETS

PUBLIC ACQUISITION CONTRACT. AWARDING PROCEDURE

Quantifying Building Engineering Demand Parameters in Seismic Events

ANALYTICAL ESTIMATION OF THE EFFECTIVENESS OF TUNED MASS CONTROL SYSTEM USING SHAKING TABLE EXPERIMENTS

Spatial steel structures with passive seismic protection.

Seismic Protection of Guyed Masts via Added Damping

PRECAST BEAM-COLUMN CONNECTION FOR INDUSTRIAL BUILDINGS

THE LAMINATION EFFECT FOR GLULAM BEAMS ACCORDING TO FRACTURE MECHANICS

THE INFLUENCE OF THE BUILDING INTEGRATED PHOTOVOLTAIC PANELS POSITION ON THE CONVERSION EFFICIENCY

FLY ASH ADMIXTURE AND ITS INFLUENCE ON ALITIC TYPE CEMENT CONCRETE PERMEABILITY

EXPERIMENTAL INVESTIGATION ON BONDING CHARACTERISTICS OF LOW-STRENGTH MORTARS USED TO REPOINT THE JOINTS OF THE DAMAGED HISTORICAL MASONRY STRUCTURES

RESEARCH ON TRANSIENT REGIME OF A PARAFFIN ACTUATOR

SEISMIC ANALYSIS OF REINFORCED CONCRETE STRUCTURES CONSIDERING DUCTILITY EFFECTS

SEISMIC ANALYSIS OF SYMMETRIC BUILDING WITH BASE ISOLATION TECHNIQUE

PERFORMANCE OF MECHANICAL SEISMIC LOAD TRANSMISSION DEVICE BASED ON IMPACT

SOUND REDUCTION EFFECTS OF PLASTERED ROCK WOOL SLAB FAÇADE THERMAL INSULATION SYSTEMS (I)

CONSIDERATIONS REGARDING NOISE PROTECTION IN A HOTEL

Dynamic Stability of Elastomeric Bearings at Large Displacement

REPLACEMENT OF CONVENTIONAL SHEAR REINFORCEMENT IN A STEEL FIBRE REINFORCED-ULTRA HIGH PERFORMANCE CEMENT BEAM

Full-scale dynamic testing of an 11-story RC building and interpretation of the results from the seismic-resistance viewpoint

WATER ABSORPTION OF SELF COMPACTING CONCRETE CONTAINING DIFFERENT LEVELS OF FLY ASH

Forced vibration testing of a thirteen storey concrete building

GENERAL PRINCIPLES FOR THE DESIGN AND CONSTRUCTION OF VENTILATED FAÇADES

An Experimental Investigation of the Seismic Response of a Bridge due to Simultaneous Horizontal and Vertical Excitations

Structural Design of a Roof Steel Structure Having Double Curvature

Research on seismic behavior of Wood-Concrete Hybrid Structure

Fragility Curves for Seismically Retrofitted Concrete Bridges

Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures

METHODS OF SAFETY ASSESSMENT THROUGH ANALYTICAL AND EXPERIMENTAL APPROACHES

Abstract. 1. Introduction

An experimental study of structural plastic hinge development and nonlinear soil deformation

A SMALL AUTONOMOUS SYSTEM FOR STORING WIND ENERGY BY PUMPING WATER

AESTHETICS OF THE MAIN TYPES OF STRUCTURES

Shake-table test on a four-storey structure with reinforced concrete and unreinforced masonry walls

INFLUENCE OF SOLUBLE SALTS CRYSTALLIZATION ON THE PHYSICAL CHARACTERISTICS OF MASONRY CERAMIC ELEMENTS

1994. Seismic behavior characteristic of high damping rubber bearing through shaking table test

Advance Design Bracing members design according to Eurocode 3

DYNAMIC TESTING OF FULL-SCALE 11-STORY RC BUILDING AND ITS 3-STORY STRUCTURAL PART: COMPARISON OF THE RESULTS AND SEISMIC RESISTANCE ESTIMATION

POSSIBLE USE OF FERROCEMENT IN ROMANIA

EXPERIMENTAL INVESTIGATION ON NON-ENGINEERED MASONRY HOUSES IN LOW TO MODERATE SEISMICITY AREAS

MODELLING METHODS FOR UNREINFORCED MASONRY STRUCTURES

DIAPHRAGM BEHAVIOUR OF THE FLOOR WITH PRESTRESSED BEAM AND FILLER BLOCKS

Transcription:

BULETINUL INSTITUTULUI POLITEHNIC DIN IAŞI Publicat de Universitatea Tehnică Gheorghe Asachi din Iaşi Tomul LXI (LXV), Fasc. 3, 2015 Secţia CONSTRUCŢII. ARHITECTURĂ SHAKING TABLE TESTS OF A BASE ISOLATED STRUCTURE WITH MULTI-STAGE SYSTEM BY DANIELA OANEA FEDIUC *, MIHAI BUDESCU and VLAD FEDIUC Gheorghe Asachi Technical University of Iaşi Faculty of Civil Engineering and Building Services Received: July 14, 2015 Accepted for publication: July 28, 2015 Abstract. The paper presents a series of experimental tests on ANCO R250-3123 shaking table from the Faculty of Civil Engineering and Building Services of Iaşi, in order to identify the structural response of a base isolated model with a multi-stage system made of four layers of elastomeric bearings. In the first phase of the experimental program, the dynamic characteristics of the structural model were determined and in the second phase the behaviour under different seismic actions of the base isolated structure with multi-stage system was evaluated. Three sinus beat actions and an artificial accelerogram were applied in the longitudinal direction of the experimental model. Following the results interpretation, a significant reduction of accelerations recorded at the top of the structure was achieved compared with the maximum acceleration recorded at the platform level. The experimental model behaved like a rigid body (the displacement values from the top and the bottom of the structure are approximately equal). Key words: seismic base isolation; multi-stage system; shaking table; sinus beat action; artificial accelerogram. * Corresponding author: e-mail: oaneadaniela@yahoo.com

10 Daniela Oanea Fediuc, Mihai Budescu and Vlad Fediuc 1. Introduction In recent years, many strong earthquakes have caused numerous economic disasters and life losses (Aslani & Miranda, 2005), which determined the search for new solutions regarding the increase of safety to seismic actions of the buildings. One of the effective solutions that protect the building, its inhabitants and the material goods, consists in decoupling the structure of the ground by mounting some bearings between the building and its foundation (Rai, 2000), so that the horizontal components of movement induced by earthquake to be limited to the maximum. The balancing phenomenon of the structure on bearings during an earthquake and the loss of stability of bearings under large horizontal displacements should be avoided when the seismic base isolation system is implemented. The multi-stage isolation system can be used to avoid the loss of stability of elastomeric bearings under large horizontal displacements (Barbat & Bozzo, 1997; Connor, 2002; Murota et al., 2005). The aim of this paper is to study the behaviour under different seismic actions of a base isolated structure with multi-stage system. The multi-stage isolation system with elastomeric bearings was used to make the experimental model to be more flexible considering that the elastomeric bearings have high horizontal stiffness. 2. Structural Model The model is a steel structure with an opening of 1.4 m, a span of 1 m and a height of 1.5 m. The columns and the beams of the structure are made of INP steel profiles, Fig. 1. The multi-stage isolation system consists of a metal frame made of HEB 180 steel profiles, with a length of 150 cm, respectively 121.5 cm in the other direction. The elastomeric bearings have 100x100 mm plane dimensions and a height of 79 mm. They have nine holes with diameters of 20 mm and the hardness of the elastomer is 60 Sh A. The additional mass consists of three concrete slabs at the top of the structure and four concrete slabs at the base of the structure, each of them having a weight of 360 kg.

Bul. Inst. Polit. Iaşi, t. LXI (LXV), f. 3, 2015 11 Fig. 1 The experimental model on the shaking table. It was used a number of three displacements transducers (D0,...,D2) mounted on a fixed frame and three accelerometers (A0,...,A2) mounted on the base isolated model with multi-stage system composed of four layers of elastomeric bearings, Fig. 2. Fig. 2 The mounting of transducers and accelerometers.

12 Daniela Oanea Fediuc, Mihai Budescu and Vlad Fediuc 3. The Experimental Program Prior to the dynamic tests, a series of calibrations of the equipment and shaking table were carried out. The experimental data, regarding the action and the response of the structure, were obtained using PT5AV transducers with a recording capacity of ±0.5 m and Dytran 3202A1 LIVM accelerometers with a recording capacity of ±10 g. In the first phase of the experimental program, a signal, a broadband sinus action between 5 and 50 Hz was introduced using a vibration generator in order to determine the dynamic characteristics of the structure. After processing the experimental data with the ESAM program, a natural frequency of 5 Hz was obtained in the longitudinal direction of the fixed base structure, which corresponds to a fundamental natural period of vibration of 0.2 s. In the case of the base isolated structure with multi-stage system, a sinus beat action of 5 Hz was introduced and a natural frequency of 0.965 Hz was obtained in the longitudinal direction, of 0.84 Hz in the transverse direction and of 4.4 Hz in the vertical direction of the model. Therefore the vibration periods of the structural model are equal to 1.04 s in the x direction, 1.19 s in the y direction and 0.22 s in the z direction. Fig. 3 The response in time of the action in the x direction. Fig. 4 The Fourier spectrum of the action in the x direction.

Bul. Inst. Polit. Iaşi, t. LXI (LXV), f. 3, 2015 13 The data were processed with a filter in order to reduce the errors that can occur due to parasitic vibrations (the filtration of the signal noise). The response in time of the action in the x direction and the Fourier spectrum are shown in Fig. 3 and 4. In the second phase, a series of experimental tests were carried out on the shaking table. Sinus beat actions and an artificial accelerogram were applied in the longitudinal direction of the experimental model (the x direction of the shaking table): a sinus beat action with a frequency of 10 Hz and a maximum acceleration of 0.5 g (test 1); a sinus beat action with a frequency of 10 Hz and a maximum acceleration of g (test 2); a sinus beat action with a frequency of 10 Hz and a maximum acceleration of 0.8 g (test 3); an artificial accelerogram with a maximum acceleration equal to 2.5 g (test 4). The action and the response in accelerations and displacements of the model, recorded at each accelerometer and displacement transducer for test 4, are shown in Figs. 5,...,10. ACCELERATION [g] 3 1-1 0 5 10 15 20 25 30 35 40 45 50-3 Fig. 5 The accelerogram recorded at the platform level (A 0 ). ACCELERATION [g] 3 1-1 0 5 10 15 20 25 30 35 40 45 50-3 Fig. 6 The response accelerogram at the base of the model (A 1 ). ACCELERATION [g] 3 1-1 0 5 10 15 20 25 30 35 40 45 50-3 Fig. 7 The response accelerogram at the top of the model (A 2 ).

14 Daniela Oanea Fediuc, Mihai Budescu and Vlad Fediuc DISPLACEMENT [mm] 50 30 10-10 0 5 10 15 20 25 30 35 40 45 50-30 -50 Fig. 8 Displacements recorded at the platform level (D 0 ). DISPLACEMENT [mm] 50 30 10-10 0 5 10 15 20 25 30 35 40 45 50-30 -50 Fig. 9 Displacements recorded at the base of the model (D 1 ). DISPLACEMENT [mm] 50 30 10-10 0 5 10 15 20 25 30 35 40 45 50-30 -50 Fig. 10 Displacements recorded at the top of the model (D 2 ). The values of the maximum accelerations (PGA) and displacements (PGD), recorded at the platform level, at the base and top of the structural model during the four tests, are shown in Figs. 11,...,14. Test 1 Test 1 PGA [g] 0.5 0.4 0.3 0.2 0.1 PGD [mm] Fig. 11 The peak values of accelerations and displacements, test 1. 1.2 1.0 0.8 0.4 0.2 Test 2 Test 2 PGA [g] 0.5 0.4 0.3 0.2 0.1 PGD [mm] Fig. 12 The peak values of accelerations and displacements, test 2. 1.5 1.2 0.9 0.3

Bul. Inst. Polit. Iaşi, t. LXI (LXV), f. 3, 2015 15 Test 3 Test 3 PGA [g] 1.0 0.8 0.4 0.2 PGD [mm] Fig. 13 The peak values of accelerations and displacements, test 3. 3.0 2.5 2.0 1.5 1.0 0.5 Test 4 Test 4 2.5 5 2.0 4 PGA [g] 1.5 1.0 0.5 PGD [mm] 3 2 1 Fig. 14 The peak values of accelerations and displacements, test 4. 4. Conclusions Following the experimental tests, a significant reduction of accelerations recorded at the top of the structure was achieved compared with the maximum acceleration recorded at the platform level. The peak acceleration is about three times lower in the case of test 1, approximately four times lower for test 2, three times lower for test 3 and twice times lower for test 4. The experimental model behaved like a rigid body (the displacement values from the top and the bottom of the structure are approximately equal) and the structure did not show degradation, even during severe action with PGA equal to 2.5 g. In conclusion, the solution of the multi-stage isolation system can successufully replace the classic isolation system, especially under high stiffeness conditions of the bearings. Through this isolation system, the loss of stability of the elastomeric bearings is avoided and an increase in the operational safety of the structures subjected to seismic actions is obtained. REFERENCES Aslani H., Miranda E., Probabilistic Earthquake Loss Estimation and Loss Disaggregation in Buildings. Report No. 157, 2005.

16 Daniela Oanea Fediuc, Mihai Budescu and Vlad Fediuc Bărbat A.H., Bozzo L.M., Seismic Analysis of Base Isolated Buildings. Archives of Computational Methods in Engineering, 4, 2 (1997). Connor J.J., Introduction to Structural Motion Control. Pearson Education Inc., New Jersey, 2002. Murota N., Feng, M.Q., Liu G.Y., Experimental and Analytical Studies of Base Isolation Systems for Seismic Protection of Power Transformers. Multidisciplinary Center for Earthquake Engineering Research, California, 2005. Rai D.C., Future Trends in Earthquake-Resistant Design of Structures. Current Science, Special Section: Seismology, 79, 9, 1291-1300 (2000). * * * Aparate de reazem pentru structuri. Partea 3: Aparate de reazem din elastomeri. Asociaţia de Standardizare din România, SR EN 1337-3-2006. ÎNCERCAREA PE PLATFORMA SEISMICĂ A UNEI STRUCTURI CU BAZA IZOLATĂ CU SISTEM MULTISTRAT (Rezumat) Se prezintă o serie de teste experimentale pe platforma seismică ANCO R250-3123 din cadrul Facultăţii de Construcţii şi Instalaţii din Iaşi, în vederea identificării răspunsului structural al unui model cu baza izolată cu sistem multistrat alcătuit din patru straturi de reazeme din elastomeri. În prima etapă a programului experimental, au fost determinate caracteristicile dinamice ale modelului structural şi în a doua etapă a fost evaluat modul de comportare la diferite acţiuni seismice a structurii cu baza izolată seismic cu sistem multistrat. Au fost aplicate trei acţiuni sinus beat şi o accelerogramă artificială, pe direc ia longitudinală a modelului experimental. În urma interpretării rezultatelor, s-a obţinut o reducere semnificativă a acceleraţiilor înregistrate la vârful structurii comparativ cu acceleraţia maximă înregistrată la nivelul platformei. Modelul experimental s-a comportat ca un corp rigid (valorile deplasărilor de la baza şi vârful structurii sunt aproximativ egale).