TA INSTRUMENTS THERMOGRAVIMETRIC ANALYZERS

Similar documents
TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETERS

TGA Thermogravimetric. Analyzer

TA INSTRUMENTS. Thermal Analysis

New Castle, DE USA. Lindon, UT USA. Hüllhorst, Germany. Shanghai, China. Beijing, China. Tokyo, Japan. Seoul, South Korea.

i Series Thermal Analysis Systems

The WORLD S FINEST line of THERMOGRAVIMETRIC ANALYZERS

DISCOVER the WORLD S FINEST SIMULTANEOUS THERMAL ANALYZER

The Q5000 Automatic Sample Processor

Differential Scanning Calorimetry DSC 200 F3

New Castle, DE USA Lindon, UT USA Pittsburgh, PA USA Elstree, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea

TA Instruments THERMOPHYSICAL PROPERTIES

Analyzing & Testing. Thermogravimetric Analysis TGA. Method, Technique, Applications

Thermal cover:layout 1 1/18/11 3:56 PM Page 2 TA Instruments

SMALL SIZE BIG POTENTIAL. STA 6000 / 8000 Simultaneous Thermal Analyzers

TGA 8000 Thermogravimetric Analyzer BETTER CHARACTERIZATIONS START WITH BETTER CONTROL

High Pressure TGA Technology and Application Examples

SEMATECH Provisional Test Method for Evaluating Bulk Polymer Samples of UPW Distribution System Components (DSC and TGA Methods)

Introduction. From the combination of TG and DTA or HDSC one receives a broad range of information, such as:

TA INSTRUMENTS. Thermal Analysis

New Castle, DE USA Lindon, UT USA Hüllhorst, Germany Shanghai, China Beijing, China Tokyo, Japan Seoul, South Korea Taipei, Taiwan Bangalore, India

DIL 402 CD Double/Differential Dilatometer

Thermogravimetric Analyzer

Thermal Analysis Excellence

Simultaneous Thermal Analysis STA 2500 Regulus

Thermal Analysis. Dr. Lidia Tajber School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin

STA 2500 Regulus Simultaneous Thermal Analysis

The WORLD S FINEST line of THERMOGRAVIMETRIC ANALYZERS

TGA/SDTA851 e Module. Thermal Analysis. Technical data Quality Service

Differential Scanning Calorimeter. DSC-60 Plus Series C160-E013A

Agilent SD-1 Purification System. Purify your way SD-1

Guide. Moisture Determination in Test Laboratories. Moisture Determination in Test Laboratories

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

G16 - THERMAL ANALYSIS

High Heating Rate DSC

Simultaneous Thermal Analyzer STA 449 F5 Jupiter

DIFFERENTIAL SCANNING CALORIMETER. Chip-DSC 100 Chip-DSC 10

DIFFERENTIAL SCANNING CALORIMETER. Chip-DSC 100 Chip-DSC 10

DIFFERENTIAL SCANNING CALORIMETER DSC PT 1000

Agilent 218 Purification System. Purify your way

THERMAL DIFFUSIVITY THERMAL CONDUCTIVITY

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

Purity Determination and DSC Tzero Technology

New Castle, DE USA. Lindon, UT USA. Hüllhorst, Germany. Shanghai, China. Beijing, China. Tokyo, Japan. Seoul, South Korea.

thermophysical properties

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

DIFFERENTIAL SCANNING CALORIMETER. Chip-DSC 100 Chip-DSC 10

C146-E096 TD-20. Shimadzu Thermal Desorption System

Apollo L Thermogravimetric Analyser. Since 1987 IMP is synonymous with providing high end innovative semi and fully automated laboratory equipment

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

ANALYTICAL STAGES. Section 10. Introduction to the MultiCentre Range of analytical stages. Configuring the MultiCentre.

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Dilatometer L 76 L 75 Horizontal L 75 Vertical

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Thermo Scientific Dionex ICS-900 Ion Chromatography System

TurboMatrix Headspace and Headspace Trap Samplers

T H E R M A L A N A L Y S I S

ICP Expert software. Technical Overview. Introduction

Thermal Analysis Application

Low-mass PM analyzer MEXA-1370PM Improvement of the Performance for PM Composition Analysis

Differential Scanning Calorimetry DSC 404 F1

MICRO THERMAL ANALYSIS CALIBRATION, REPEATABILITY AND REPRODUCIBILITY

UV/Vis Spectrophotometry. Time for New Demands SPECORD PLUS

Analyzing & Testing. Guarded Hot Plate - GHP. Method, Instrumentation, Applications. GHP 456 Titan. Leading Thermal Analysis

MB3000-PH. FT-IR Spectrometer for the Pharmaceutical Industry Designed for QA/QC, Formulation, Research and Development Laboratory Applications.

THW-L2 LIQUIDS PASTES INSULATION. Portable Thermal Conductivity Meter for Measurement of Liquids, Pastes, & Insulation.

Fusion UV/Persulfate TOC Analyzer

LCR 7000 Series Capillary Rheometers. Single Bore LCR 7000 Dual Bore LCR 7002

QUENCHING DILATOMETRY

Sum Parameter Analysis AOX/TOX. AOX Analyzer multi X 2500

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

TGM800: Thermogravimetric Moisture

THE USE OF MICROWAVE TECHNOLOGY FOR DRY ASHING PROCEDURES. by S. E. Carr and C. R. Moser. CEM Corporation, Matthews, North Carolina.

Halogen Moisture Analyzers

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Impact of Tzero Technology on the Measurement of Weak Transitions

API 3200 LC/MS/MS system

Carbon / Hydrogen / Sulfur Analyzers

Chrom-Card Data System. A simple, chemist-oriented data handling system...productive from the first day!

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

EXPAND YOUR RANGE EXTEND YOUR RESOURCES. Avio 500 ICP Optical Emission Spectrometer

THERMO- GRAVIMETRIC ANALYZER TGA 1600

100% Swiss The highest in Quality & Technology

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

on a Perkin-Elmer (Dublin, Ireland) Spectrum 100 FT-IR spectrometer fitted with a Universal ATR Sampling Accessory.

100% Swiss The highest in Quality & Technology

ABB MEASUREMENT & ANALYTICS. AlSCAN and AlSCAN Argon Hydrogen analysis in liquid aluminum

SETSYS Evolution. The top of the range in thermal analyzers DTA, DSC, TGA, TGA-DTA/DSC, TGA-EGA, TMA KEP TECHNOLOGIES

AOX/TOX, EOX and POX analyzers; DEXTAR, ECS 1200 and ECS Total Halogen expertise fulfilling your Environmental analytical needs

Instructions for using the PerkinElmer DSC-8500

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications

The Flash DSC 1 A Novel Rapid Scanning Calorimeter

MB3600. Versatile FT-NIR analyzer designed for your industry. The most reliable FT-NIR specifically designed for QA / QC.

Fusion UV/Persulfate TOC Analyzer

OPEN YOUR EYES TO A WORLD OF OPPORTUNITY IN THERMAL ANALYSIS. DSC 4000/6000/8000/8500 Comprehensive Solutions for Differential Scanning Calorimetry

dilatometry ΔL ΔT α = 1 ( )

FluentControl TM TAKE CONTROL OF TECAN S MOST POWERFUL LIQUID HANDLING WORKSTATIONS

Transcription:

TA INSTRUMENTS THERMOGRAVIMETRIC ANALYZERS

TA INSTRUMENTS Q SERIES THERMOGRAVIMETRIC ANALYZERS Sensitive, Precise, Rugged and Automated are words that describe a TA Instruments Thermogravimetric Analyzer. The Q500 and Q50 are fourth generation products from the world leader in thermogravimetric analysis. Each represents an unparalleled investment because it delivers outstanding performance, is designed with the customer in mind, and is backed by superior support that is the hallmark of our company. The Q500 is our top-of-the-line research-grade thermogravimetric analyzer. Its efficient low mass furnace, ultra-reliable thermobalance, unique purge gas system (with mass flow control), and advanced automation provide for superior TGA performance. The Q500 is an expandable system that is well equipped to handle TGA applications, from the routine to the most demanding. The Q50 is a cost-effective, easy-to-use, generalpurpose thermogravimetric analyzer with many of the basic features of the Q500. It offers performance superior to most research grade models. The Q50 is ideal for laboratories that need a high quality TGA for standard applications.

TECHNICAL SPECIFICATIONS Furnace - Low Mass Standard Standard Furnace - EGA Optional Optional Touch-Screen Display Standard Not Available Mass Flow Controller with automatic gas switching Standard Optional Autosampler Optional Not Available Hi-Res TGA Optional Not Available Modulated TGA Optional Not Available TGA / MS operation Optional Optional Temperature Range Ambient to 1000 C Ambient to 1000 C Isothermal Temperature Accuracy +/- 1 C +/- 1 C Isothermal Temperature Precision +/- 0.1 C +/- 0.1 C Weighing Capacity 1.0 gm 1.0 gm Sensitivity 0.1µg 0.1µg Weighing Precision +/- 0.01% +/- 0.01% Temperature Calibration Heating Rate - Low Mass Heating Rate - EGA Furnace Cooling Curie Point / metal stds (1 to 5 points) 0.1 to 100 C / min in 0.01 C / min increments 0.1 to 50 C / min in 0.01 C / min increments Forced air 1000 C to 50 C <12 min Sample Pans Platinum: 50 µl, 100 µl Ceramic: 100 µl, 250 µl, 500 µl Aluminum: 100 µl

INSTRUMENT DESIGN FEATURES AND BENEFITS A TGA is only as good as its ability to accurately and reproducibly measure mass and temperature changes. Experience is a vital part of TGA design, and the knowledge gained by our engineers in thirty five years of integrating customized thermobalances, furnaces and purge gas systems to produce thermogravimetric analyzers, has resulted in the unparalled performance and reliability of the Q Series. Thermobalance The heart of a Q Series TGA is the accurate and ultra-reliable vertical thermobalance, which is housed in a temperature controlled environment. It operates under the field proven null-balance principle, where an optically active servo loop maintains the balance arm in the horizontal reference (null) position by regulation of current flowing through a transducer coil. An infrared LED source and a pair of matched photodiodes detect beam movement, while a flag attached to the balance arm controls the amount of light reaching each photodiode. As sample weight changes, the beam becomes unbalanced, and the net photodiode output is fed to a control program, which electrically nulls the balance. The current required is directly proportional to the sample weight change. The design provides for automatic switching between the dual weight ranges of 0 to 200 milligrams and 0 to 1 gram. Benefits: High accuracy and precision in detection of minute weight changes from ambient to 1000 C, low baseline drift, plus smooth, continuous, reliable operation over the entire weight range. 7 3 2 1 4 TGA SCHEMATIC 1 SAMPLE PAN 6 5 2 THERMOCOUPLE 3 TARE PAN 4 SAMPLE PLATFORM 8 5 PURGE GAS INLET 6 PURGE GAS OUTLET 7 BALANCE CHAMBER 8 FURNACE

BALANCE PURGE Furnace Our custom designed furnace is the second key element of a Q Series TGA. It features low mass, rugged heater windings, and proprietary heater control technology. Benefits: Rapid, accurate and precise temperature programming over a wide range, plus optimized use of advanced techniques such as Hi-Res TGA and Modulated TGA. Our reliable, long-life furnaces also increase the value of your investment FURNACE HOUSING FURNACE PURGE Purge Gas System A distinguishing feature of a Q Series TGA is the successful integration of a sensitive vertical thermobalance, a high performance furnace and a unique horizontal purge gas system. In this design, purge gas enters the furnace through a side arm and flows directly across the sample located in an open pan suspended from the vertical balance. A low volume of inert purge gas is also directed through the balance chamber to prevent any back diffusion of the primary purge gas (if different) or decomposition products into the balance chamber. The combined gases leave the sample chamber by a second side arm that can be readily connected to a second identification instrument (e.g. MS or FTIR). Benefits: This design minimizes buoyancy effects and has been proven superior to other vertical purge gas designs in sweeping away decomposition products from the sample area. The metering of purge gas to the furnace and balance housing is accurately and precisely controlled by the mass flow controllers, which are a standard feature on the Q500, and optionally available for the Q50 (see Accessory section for further details). Temperature Control and Measurement Our unique, custom designed system features a single control / sample thermocouple positioned immediately adjacent to the sample. The value of this innovative design is enhanced by a second thermocouple located in the same sleeve but slightly above the principal one. Benefits: Simultaneous heating rate control and sample temperature measurement are accurately and precisely accomplished. This innovative control and feedback design enables the system controller to program and maintain the temperature environment and heating rate selected by the operator. The second thermocouple functions as a furnace protection mechanism. The controller monitors the temperature difference between both thermocouples, and if it exceeds a set point the furnace is automatically shutdown.

Q500 ACCESSORIES & OPTIONS AUTOSAMPLER The Q500 Autosampler accessory is a programmable, multi-position sample carousel that allows overnight or round-the-clock automated analyses, in a random or sequential fashion, of up to 16 samples. All aspects of sample testing are totally automated and controlled by the Q500 software, including pan taring, pan loading, sample weighing, furnace movement, pan unloading and furnace cooling. The autosampler has the flexibility to satisfy the needs of both analytical and quality control laboratories. Maximum productivity from the Q500 Autosampler is achieved when paired with the intelligent Thermal Advantage Autoanalysis software, which permits pre-programmed analysis, comparison and presentation of results. MASS FLOW CONTROLLER (WITH AUTOMATIC GAS SWITCHING) The mass flow controllers supplied with the Q500, and available for the Q50, permit accurate, reproducible purge gas metering to the TGA sample and balance chambers. The benefit is consistently superior data quality over conventional flow control devices. The automatic gas switching capability employs low volume, high-speed valves to provide instantaneous changeover of purge gases as programmed in the test method. This is especially useful when rapid changes from inert to oxidizing atmospheres are required. Purge gas flow rates are stored as a signal in the data file.

Q500 / Q50 SAMPLE PANS TA Instruments offers a series of sample analysis pans in various sizes and in platinum, aluminum or ceramic. In general, platinum is preferred because of its inertness and post-experiment ease of cleaning. Ceramic pans are used for samples that react with platinum, and where larger capacity is required. Aluminum pans are a low cost alternative for applications below 600 C. HIGH RESOLUTION TGA (HI-RES TGA) Hi-Res TGA is a patented TA Instruments furnace control technology that improves the ability to separate closely occurring decomposition events. The intelligent design of the Q500 makes it ideally suited for such experiments, where it is critical to precisely and rapidly control sample temperature and monitor small weight changes. This Q500 option includes three control algorithms (constant reaction rate, stepwise isothermal, and dynamic rate) that consistently improve weight change resolution over results from linear heating rate TGA. Each technique has specific advantages, but the dynamic method is the most generally applicable since it is the simplest to use, minimizes the need for operator expertise, and generates comparable results in a fraction of the time required for the other methods. MODULATED TGA Modulated TGA (MTGA) is another TA Instruments innovation for the study of material decomposition by TGA. It produces continuous, model-free kinetic data, equivalent in quality to that from the traditional TGA decomposition method (ASTM Standard E1640), but in a fraction of the time. Desired parameters, such as activation energy and the pre-exponential factor can be calculated on a continuous basis, and studied as a function of time, temperature and conversion. MTGA is easy-to-use, and provides the kinetic information needed to follow and improve productivity in many industrial processes. This Q500 accessory takes advantage of the proprietary heater control technology developed for Hi-Res TGA and also for the widely accepted Modulated DSC (MDSC ) technique - another first from TA Instruments.

EVOLVED GAS ANALYSIS (EGA) FURNACE The EGA is a larger optional furnace for a Q Series TGA that uses a similar rugged design but incorporates a quartz liner between the heating element and the sample measurement area. This arrangement results in a small internal volume, which further reduces the possibility for back diffusion of sample off-gases into the balance chamber by assuring rapid transfer of the gases out of the furnace exit port. The quartz liner provides an essentially inert surface to sample decomposition products. This furnace is ideal for coupled use with a MS or FTIR, instruments that can uniquely identify the decomposition products from the TGA analysis. The results from these coupled techniques are qualitative and quantitative information on the temperature stability of the sample, its composition, method of decomposition, and identification of the products evolved. CALIBRATION STANDARDS The Thermal Advantage software supplied with the Q Series TGA supports the use, for temperature calibration purposes, of either Curie Point or melting point standards (1 to 5 materials). User-friendly software wizards simplify the process, which follows the ASTM Temperature Standard (E1582) for TGA calibration. Each Q Series TGA is supplied with temperature calibration materials in the accessory kit. However, traceable calibration standards are also available for those customers, whose experimental protocols necessitate their use. The TGA Curie Point method records for each standard, an apparent sharp weight change at a well defined temperature, which corresponds to a known transformation in the standard s ferromagnetic properties at that temperature. This technique is also termed thermomagnetometry. This Figure shows the relative temperature precision obtained from three replicate calibration runs using alumel and nickel Curie Point standards. Weight (%) 110 108 106 104 102 Alumel Curie Point Pooled Precision ±0.135 C 100 Alumel Curie Point = 154.06 C Nickel Curie Point = 358.28 C 98 25 125 225 Temperature ( C) Curie Point Precision Alumel and Nickel (3 runs) Heating Rate = 10 C/min. Nickel Curie Point Pooled Precision ±0.070 C 325 425

THERMAL ADVANTAGE SOFTWARE A quality Thermal Analyzer requires flexible, intelligent software to power it. No one believes this more than our software engineers, who have pioneered most of the features commonly seen in today s modern thermal analyzers. 32-bit Thermal Advantage for Q Series software is Microsoft Windows based, and expandable to meet growing customer needs. THERMAL ADVANTAGE INSTRUMENT CONTROL Multitasking conduct experiment and simultaneously analyze data Multimodule can operate up to 8 modules simultaneously Wizards guides and prompts in setting up experiments Preference Choices customize the look and feel of the experiment Flexible Method Editor design & save the correct method for your material Real-time plot provides a real-time picture of the progress of the experiment Autoqueing permits pre-programmed set-up of future experiments How To feature provides extensive, context sensitive operator assistance UNIVERSAL ANALYSIS 2000 DATA ANALYSIS Single Package analyzes data from all TA Instruments thermal modules Picture-in-a-picture provides easy one plot analysis of large and small events Real-Time data analysis ability to analyze data as it arrives Interchangeable graphics / spreadsheet view of data Custom report generation within UA 2000 using Microsoft Word & Excel templates Autoanalysis for pre-programmed analysis, comparison & presentation of results Saved Analyses for quick retrieval of previously analyzed data files Library of Specialty Data Analysis specialty analysis programs (e.g., TGA Decomposition Kinetics Software, ASTM D1640). Microsoft Windows, Microsoft Word, and Microsoft Excel are trademarks of Microsoft Corporation

APPLICATIONS Thermogravimetric Analysis (TGA) measures the amount and rate of change in the weight of a material as a function of temperature or time in a controlled atmosphere. It is commonly used in academic, industrial and government research, as well as in quality control laboratories. TGA is particularly useful for the following material characterization determinations: Composition of multi-component materials Thermal stability of materials Oxidative stability of materials Decomposition kinetics of materials Estimated lifetime of materials Moisture and volatile contents of materials THERMAL STABILITY A main use of TGA is to determine the thermal stability of materials and to reveal their weight loss decomposition profiles. Figure 1 shows a series of thermal curves for some common polymers (PVC, PMMA, HDPE, PTFE) plus a highly filled polyimide. The information allows design engineers to select materials suitable for end uses where heat stability at specified temperatures is required. Weight (%) 120 100 80 60 40 20 0 FIGURE 1 Sample Size = 10mg Heating Rate = 10 C/min Nitrogen Purge PVC PMMA HDPE PTFE PI -20 0 200 400 600 800 Temperature ( C) Weight (%) FIGURE 2 120 100 80 60 40 20 0 0 100 200 300 400 500 Temperature ( C) Latex Flat Paint Latex Gloss Paint Oil Based Gloss Paint Weight Loss: 1st 2nd Latex Flat: 56% 8% Latex Gloss: 51% 30% Oil Based Gloss: 45% 32% (10 C/min.; Nitrogen Purge) 600 COMPOSITION ANALYSIS The other main use of TGA is to determine the composition of a material by measuring the weight (mg or wt %) of each component as it decomposes in response to the experimental conditions of temperature, time and atmosphere. Figure 2 shows the quantitative decomposition profile of three paints. Differences in the type, amount, and the decomposition mechanism of the main copolymers used are readily observed. Examination of the low temperature region (<150 C) would reveal further information on the amount and possible nature of the carrier solvent (aqueous or oil) used in each paint.

HIGH RESOLUTION TGA Figure 3 compares the results from conventional and Hi-Res TGA in the analysis of a polyurethane. In both analyses, the sample is stable up to almost 300 C, where it undergoes a multi-step decomposition process. The superior resolution of the Hi-Res TGA results are apparent, especially in the derivative signal. The Hi-Res method also reached the decomposition temperature in one fifth of the time taken by the standard method. Weight (%) 120 80 40 0-40 FIGURE 3 Standard TGA: ß = 10 C/min. Hi-Res TGA: ß = 50 C/min., Res = 5 Nitrogen Purge = 100mL/min. Polyurethane: Standard TGA Polyurethane: Hi-Res TGA 7 5 3 Deriv. Weight (%/ C) 1-80 -120 0 100 200 300 400 Temperature ( C) -1 500 600 700 Weight (%) 110 90 70 50 30 10-10 200 FIGURE 4 Conventional Dynamic Stepwise Isothermal 300 400 500 600 Temperature ( C) HIGH RESOLUTION TGA Similar results are shown in Figure 4, which compares the analysis of a polyvinyl acetate polymer by conventional TGA, the stepwise isothermal and dynamic Hi-Res techniques. The superiority in resolution of the latter two is clearly evident. While the stepwise isothermal method produces the sharpest weight losses, the dynamic method shows comparable resolution but in a shorter experiment time. MOISTURE AND VOLATILES ANALYSIS Determination of adsorbed, bound or included moisture, as well as organic volatiles, is an important TGA application in a wide variety of industries. Product performance is often dependent on this parameter. Environmental concerns are increasingly important in the case of volatile organic compounds (VOC s). TGA analysis of an organic salt hydrate in a nitrogen atmosphere (Figure 5), shows a bound water content of 9.6%, with two lower temperature weight losses of 3.6% and 2.3 % respectively. These lower temperature losses are likely due to moisture either at the surface of the salt or held to it by weak attractive forces. Weight (%) 105 100 95 90 85 80 FIGURE 5 59.00 C 75 20 40 60 Loss 1 Loss 2 101.30 C 131.25 C Organic Salt Hydrate Loss 1 3.57% Loss 2 2.31% Loss 3 9.64% Total 15.52% Loss 3 0.8 0.6 0.4 0.2 0.0-0.2 80 100 120 140 160 180 200 Temperature ( C) Deriv. Weight (%/ C)

TO CONTACT YOUR LOCAL TA INSTRUMENTS TECHNICAL REPRESENTATIVE VISIT OUR WEBSITE AT WWW.TAINST.COM NEW CASTLE, DE USA - TELEPHONE: 302-427-4000 PARIS, FRANCE - TELEPHONE: 33-1304-89460 BRUSSELS, BELGIUM - TELEPHONE: 32-2-706-0080 LEATHERHEAD, ENGLAND - TELEPHONE: 44-1372-360363 ETTEN-LEUR, NETHERLANDS - TELEPHONE: 31-76-508-7270 ALZENAU, GERMANY - TELEPHONE: 49-6023-96470 MILANO, ITALY - TELEPHONE: 39-02-27421-200 TOKYO, JAPAN - TELEPHONE: 81-3-5479-8418 MADRID, SPAIN - TELEPHONE: 34-91-203-9100 SYDNEY, AUSTRALIA - TELEPHONE: 61-2-9933-1705 TA-263