STUDY ON SEISMIC PERFORMANCE OF LOW EARTHQUAKE RESISTANT MASONRY BUILDINGS RETROFITTED BY PP-BAND MESH

Similar documents
Shaking table test on seismic response behavior of 2-story masonry house model with PP-band mesh retrofitting

Shaking Table Test of Two-Story Masonry House Model Retrofitted by PP-band Mesh

Experimental study on PP-band mesh seismic retrofitting for low earthquake resistant arch shaped roof masonry houses

EXPERIMENTAL STUDY OF SEISMIC BEHAVIOR OF SCALED NON-ENGINEERED MASONRY STRUCTURES RETROFITTED BY PP-BAND MESH

An Experimental Study on the Effect of Opening on Confined Masonry Wall under Cyclic Lateral Loading

In Plane Behavior of Polypropylene and FRP Retrofitted Brick Masonry Wallets under Diagonal Compression Test

NSET EXPERIENCE ON SEISMIC RETROFITTING OF MASONRY AND RC FRAME BUILDINGS IN NEPAL

Shaking Table Tests for Brick Masonry Houses

Experimental Study on the Behaviour of Plastered Confined Masonry Wall under Lateral Cyclic Load

Shake-table test on a four-storey structure with reinforced concrete and unreinforced masonry walls

EXPERIMENTAL STUDY OF THE DEFORMATION CAPACITY OF STRUCTURAL MASONRY

STRUCTURAL LAB. FACILITY AT IITG IN THE DIRECTION OF TRADITIONAL/LOCAL HOUSING

PROVISION OF EARTHQUAKE SAFETY FOR BUILDINGS FROM WEAK LOCAL MATERIALS

CONTAINMENT REINFORCEMENT FOR EARTHQUAKE RESISTANT MASONRY BUILDINGS

Shaking Table Test of BRB Strengthened RC Frame

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

HISTORICAL REVIEW OF MASONRY STANDARDS IN NEW ZEALAND

EXPERIMENTAL STUDY ON THE PERFORMANCE OF THE RC FRAME INFILLED CAST-IN-PLACE NON- STRUCTURAL RC WALLS RETROFITTED BY USING CARBON FIBER SHEETS

SEISMIC RETROFITTING OF EXISTING BUILDINGS

Experimental and field performance of PP band retrofitted masonry: evaluation of seismic behavior

Strengthening or Retrofitting

Comparative Cost Analysis of Possible Seismic Retrofitting Schemes for Multi-Story Unreinforced Masonry Building

ENG.ACA.0001F Madras. New Zealand significant. (a) spandrel 2010) were solid

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

Safe Site 1 RUMÖH LÖEN SYURGA LÖEN

Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile detailing

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

DESIGN AND MASONRY BASIC DESIGN GUIDELINES FOR CSEB. General principles for a good design

STRUCTURAL IMPROVEMENT OF UN-REINFORCED MASONRY HOUSES IN EARTHQUAKE PRONE REGIONS: PROPOSAL OF AN EFFECTIVE AND AFFORDABLE REINFORCEMENT

One side strengthening of masonry walls with self-compacting concrete

Effect of soft storey in a structure present in higher seismic zone areas

7 NON-STRUCTURAL ELEMENTS

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

Finite Element Modelling of Unreinforced Masonry (URM) Wall with Openings: Studies in Australia

Evaluation of Shear Demand on Columns of of Masonry Infilled Reinforced Concrete Frames

Retrofitting methods

Literature Review of Wood-frame Structure Tests

Strengthening of infilled RC frames by CFRP

EXPERIMENTAL INVESTIGATION OF THE JACK ARCH SLAB RETROFITTED BY CONCRETE LAYER

6.2 Stabilization through mass Rammed earth walls 60 to 100 cm thick, which are not too high, can withstand horizontal seismic shocks without addition

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Note on the assessment:

Confined masonry. An illustrated guide for masons. This manual explains this technique. Confined masonry. RC frames. Columns first, walls after

Figure 1 Swing Span Supported by Center Pivot Pier and Two Rest Piers

Experimental Studies to Verify the Efficacy of Earthquake Resistant Measures in Brick Masonry Buildings

^Earthen Building Technologies, Pasadena, California, P7707, L%4

NEWSLETTER. Vol.18 No.3 JANUARY 2015 ISSN:

INFLUENCE OF HORIZONTAL OFFSETS OF OPENINGS IN SINGLE STORY BRICK MASONRY BUILDINGS UNDER SEISMIC FORCES

BEHAVIOR OF NON-ENGINEERED HOUSES DURING PISCO EARTHQUAKE 15/8/2007

SEISMIC STRENGTHENING OF PARTIALLY INFILL RC BUILDINGS USING BRICK INSERTS - EXPERIMENTAL INVESTIGATION ON 3D MODEL STRUCTURE

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY

GUIDELINE FOR POST-EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN

COMPARISON OF IN-SITU AND LABORATORY TESTS OF BRICK MASONRY WALLS STRENGTHENED WITH CARBON FIBRE REINFORCED POLYMER FABRIC

Eurocode 8 Timber and Masonry structures

Masonry infills with window openings and influence on reinforced concrete frame constructions

Technical Version: 1 December 2009 PERFORMANCE OF STEEL FRAMES IN EARTHQUAKES

Tsunami Countermeasures at Hamaoka Nuclear Power Station -- Design and Construction of Tsunami Protection Wall

A Summary Report on Muzaffarabad Earthquake, Pakistan

EXPERIMENTAL RESULTS

Ithaka Journal biochar materials, ecosystems & agronomy

EXPERIMENTAL INVESTIGATION ON NON-ENGINEERED MASONRY HOUSES IN LOW TO MODERATE SEISMICITY AREAS

SEISMIC PERFORMANCE OF AAC INFILL AND BEARING WALLS WITH DIFFERENT REINFORCEMENT SOLUTIONS ANDREA PENNA

SEISMIC DESIGN OF STRUCTURE

RECENT RESEARCH ON TALL AND HYBRID WOOD STRUCTURES

4. BUILDINGS, DWELLINGS AND BRIDGE

VIBRATION RESPONSE CHARACTERISTICS OF ROCKING PILLAR BASE ISOLATION SYSTEM SUITABLE FOR MASONRY HOUSES

EFFECTS OF SOFT FIRST STORY ON SEISMIC PERFORMANCE OF RC BUILDINGS AND SUSTAINABLE APPROACH TO RETROFIT

SEISMIC BEHAVIOUR OF CAPACITY DESIGNED MASONRY WALLS IN LOW SEISMICITY REGIONS

UNREINFORCED MASONRY STRUCTURES -PART I - DEFINITIONS AND PROBLEMS UNDER LATERAL LOADS

SEISMIC REHABILITATION OF TRADITIONAL UN-REINFORCED MASONRY BUILDINGS IN IRAN

August 2016 DESIGNING FOR MOVEMENT IN BRICKWORK

INVESTIGATION ON TECHNIQUES TO CONTROL STRUCTURAL DAMAGE DUE TO BLASTING ACTIVITIES

Seismic Performance of RC Structural Walls with Slits: Analytical Study

Seismic safety assessment of an unreinforced masonry building in Albania

University of East London Institutional Repository:

Experimental Study on Confined Brick Masonry in Indonesia

Cu-Al-Mn Super-elastic Alloy Bars as Dissipative Brace System in Structural Steel Frame

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

Post-Earthquake Performance of Sheet Bracing Systems

Estimating Performance Point of Existing Masonry Buildings and Study on their Improvement using Retrofitting Method

Seismic behaviour of mortar-free interlocking column

Collapsing Simulation of Wooden House Retrofitted by ACM Braces During Seismic Ground Motion

Bijapur Karnataka, India) 2. Corresponding Author- Phone , -

NUMERICAL ANALYSIS OF UNREINFORCED THREE-LEAF STONE MASONRY BUILDINGS UNDER EARTHQUAKES

Seismic retrofitting of Pombalino frontal walls

CHAPTER 5 FINITE ELEMENT MODELING

BOUNDARY CONDITIONS OF SHEAR WALLS IN MULTI-STOREY MASONRY STRUCTURES UNDER HORIZONTAL LOADINGS

CE 6071 Structural Dynamics and Earthquake Engineering UNIT -5 2 MARKS

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING

SEISMIC SAFETY IMPROVEMENT OF HOUSING SECTOR IN THE HISTORICAL CENTER OF THE CITY OF SANTA TECLA IN EL SALVADOR

FRICTION-BASED SLIDING BETWEEN STEEL AND STEEL, STEEL AND CONCRETE, AND WOOD AND STONE

Documentation of the Seismic Evaluation and Retrofit Process

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

DYNAMIC TESTING OF FULL-SCALE 11-STORY RC BUILDING AND ITS 3-STORY STRUCTURAL PART: COMPARISON OF THE RESULTS AND SEISMIC RESISTANCE ESTIMATION

Design Requirements of Buildings and Good Construction Practices in Seismic Zone

THE SEISMIC PERFORMANCE OF FLOORING SYSTEMS EXECUTIVE SUMMARY. Dene Cook 1

Transcription:

The 13th Japan Earthquake Engineering, Symposium (2010) STUDY ON SEISMIC PERFORMANCE OF LOW EARTHQUAKE RESISTANT MASONRY BUILDINGS RETROFITTED BY PP-BAND MESH Navaratnarajah SATHIPARAN 1 and Kimiro MEGURO 2 1 JSPS Postdoctoral Fellow, Institute of Industrial Science, University of Tokyo, Japan, sakthi@iis.u-tokyo.ac.jp 2 Director/ Professor, ICUS, Institute of Industrial Science, The University of Tokyo, Japan meguro@iis.u-tokyo.ac.jp ABSTRACT: This paper introduces a technically feasible and economically affordable PP-band (polypropylene bands) retrofitting for low earthquake resistant masonry structures in developing countries. Results of shaking table tests on building models show that the PP-band retrofitting technique can enhance safety of both existing and new masonry buildings even in worst case scenario of earthquake ground motion like JMA7 seismic intensity. Therefore proposed method can be one of the optimum solutions for promoting safer building construction in developing countries and contribute earthquake disaster mitigation in future. Key Words: Unreinforced masonry, Polypropylene band, PP-band mesh retrofitting, Shaking table test 1. INTRODUCTION Masonry is the most universally available and economical construction material. The common materials of masonry construction are burned and unburned bricks called adobe, stones and concrete blocks. Adobe masonry made of unburned bricks is the most common type of masonry. Masonry structures are generally self-made because the construction practice is simple and does not require additional energy consumption. In addition to its low cost and simple construction technology, masonry has other advantages, such as excellent thermal and acoustic properties. In spite of this, the technological development of masonry in earthquake engineering has lagged behind compared to the other structural materials like concrete and steel. Therefore, earthquake prone regions in the world have suffered a large number of casualties due to the collapse of this type of structures. This is a serious problem for the societies. Apparently, its solution is straight forward: retrofitting the existing structures. When we propose the retrofitting method in developing countries, that method should respond to the structural demand on strength and/or deformability as well as to availability of material with low cost including manufacturing and delivery, practicability of construction method and durability in each region. Considering these issues on developing appropriate seismic retrofitting techniques for masonry buildings to reduce the possible number of casualties due to future earthquakes in developing countries, a technically feasible and economically affordable PP-band (polypropylene bands; PP-band is commonly used for packing.) retrofitting technique has been developed and many different aspects have been studied by Meguro Laboratory, Institute of Industrial Science, The University of Tokyo (Mayorca P. and Meguro K., 2004). A real scaled model test makes possible to obtain data similar to real structures. However, it requires large size testing facilities and large amount research funds, so it is difficult to execute parametric tests by using full scaled models. Therefore, in this study we performed scale model tests to understand the overall behavior of the system. In this research, in order to understand the dynamic

response of masonry houses with and without PP-band mesh retrofitting, crack patterns, failure behavior, and overall effectiveness of the retrofitting technique, shaking table tests were carried out. 2. DESIGN AND CONSTRUCTING THE MODEL Considering the shaking table size and allowable loading condition, the model scaling factor adopted was 1:4 as shown in Fig. 1. Two models were used for shaking table test. The dimensions of both building models were 933mmx933mmx720mm with 50mm thick walls. The sizes of door and window in opposite walls were 243mmx485mm and 325mmx245mm, respectively. Both models were represented one-storey box-like building with timber roof; one model was non-retrofitted and other model was retrofitted with PP-band mesh after construction. Specimens are consisted of 18 rows of 44 bricks in each layer except openings. It took two days for construction of one specimen. The first 11 rows were constructed in first day and remaining rows were done in following day. The geometry, construction materials and mixture proportion, construction process and technique and other conditions that may affect the strength of the building models were kept identical for better comparison. The cross-section of the band used was 6mm 0.32mm and the pitch of the mesh was 40mm. Fig. 1 House model for shaking table tests (dimensions in mm) The mortar with the mixture ratio of cement, lime and Table 1 Mechanical property of masonry specimens sand=1:2.8:8.5 and Cement/Water Non-retrofitted Retrofitted ratio=0.33% was used for adobe Strength model (in MPa) Model (in MPa) unburned brick masonry to Compression 4.28 4.36 simulate adobe masonry buildings Shear 0.0057 0.0068 in developing countries. Average measured mechanical properties of Bond 0.0046 0.0046 the masonry at the time of testing Diagonal shear 0.041 0.045 are listed in Table 1. The retrofitted procedure explained below is shown in photos (Fig. 2) taken during the preparation of experimental program. PP-bands are arranged in meshes and connected at their intersection points using a portable plastic welder. Structure walls are cleaned and any loose pieces of brick should be removed. Straw, which placed in holes are removed. (in this experiment, during construction of model house, we put the straw in the place at approximately 160mm pitch where we required holes.) In case of existing structures, holes can be prepared by drilling through the wall. Walls are wrapped by meshes around the corners and wall edges. The overlapping length should be long enough to accommodate sufficient wire connectors as these are the only system used to connect meshes to the structure. Wires are passed through wall holes and used to connect the meshes on both wall sides. In order to prevent the wires from cutting the PP-band meshes, a plastic piece or any other stiff element is placed between the band and the wire. It is desirable to have connectors as close as possible to the wall intersections and corners. The top/bottom mesh edges are connected with steel wires. The bottom edge should be connected to the structure foundation as much as possible. Fixed connectors around the openings after the mesh was cut and overlapped on the other side.

Fig. 2 PP-band mesh Retrofitting procedure for masonry house 3. INPUT MOTION Simple easy-to-use sinusoidal motions of frequencies ranging from 2Hz to 35 Hz and amplitudes ranging from 0.05g to 1.4g were applied to the specimens to obtain the dynamic response of both retrofitted and non-retrofitted structures. This simple input motion was applied because of its adequacy for later use in the numerical modeling. Fig. 3 shows the typical shape of the applied sinusoidal wave input motion. Fig. 3 Typical Shape of Input Sinusoidal Motion Table 2 Loading Sequence Amplitude Frequency 2 5 10 15 20 25 30 35 1.4g 50 1.2g 49 1.0g 48 0.8g 53 47 43 40 37 34 31 28 0.6g 52 45 42 39 36 33 30 27 0.4g 51 44 41 38 35 32 29 26 0.2g 46 25 24 23 22 21 20 19 0.1g 18 17 16 15 14 13 12 11 0.05g 10 09 08 07 06 05 04 03 Sweep 01,02

Loading was started with a sweep motion of amplitude 0.05g with all frequencies from 2Hz to 35Hz for identifying the dynamic properties of the models. The numbers in Table 2 indicate the run numbers. General trend of loading was from high frequency to low frequency and from lower amplitude to higher amplitude. Higher frequencies motions were skipped towards the end of the runs. To assess the global and local behavior, specimens were instrumented to measure accelerations and displacements. During the tests, twenty four accelerometers, eighteen on house and six on roof were installed at the location shown in Fig. 4. The number of accelerometers was 16, 4 and 4 in the exciting, transverse and vertical direction respectively. Five lasers, in N-S direction were used to measure displacements. The locations of laser measuring instruments are shown in Fig. 4. L1, L2, L3 aimed at obtaining the wall deformation at top level in the direction of shaking. Laser L4 recorded the facade wall deformation at centre. Laser L5 recorded the deformation at base. The measured data were recorded continuously throughout the tests. The sampling rate was 1/500 sec in the all runs. Fig. 4 Location of accelerometers and lasers 4. CRACK PROPAGATION In both specimens, due to shrinkage, some minor cracks were observed before the test. These cracks mainly appear closer to opening in horizontal direction. Up to the Run 21, no major crack was observed in both models. 4.1. NON-RETROFITTED MODEL Observed responses during test runs for non-retrofitted model were given as follows; Run 22 - Cracks were observed from corners of the window opening and they propagated up to top and bottom layer of the wall. Still there were no major cracks observed in walls, which are in the direction of Shaking (Fig. 5). Run 28 - Cracks were observed at one of the top corners of the door opening and they propagated up to top layer of the wall. Fig. 5 Crack patterns observed on non-retrofitted model after Run 22 Fig. 6 Crack patterns observed on non-retrofitted model after Run 44

Fig. 7 Non-retrofitted model after Run 45 Run 34 - Cracks propagated from openings to corners were more widen up. Cracks at bottom of the east wall and top of the north and south walls were observed. Run 37 - Cracks appeared at the top of the north and south walls and propagated through out the whole wall. More cracks were observed in the part above the openings. Run 45 - All top part of the wall with opening was totally separated from the specimen and fallen from specimen. The roof was just supported by two walls, which were in the direction of shaking. Therefore, due to walls subjected to out-of-plane load; they were bursts outwards in shaking direction. This finally led to the structure collapse. 4.2. RETROFITTED MODEL Observed responses during test runs for retrofitted model were given as follows; Run 22 - Cracks were observed from top corner of the door opening and they propagated up to top layer of the wall. Additional cracks propagated horizontally from top and bottom of the door opening (Fig. 8). Run 31 - Cracks were observed from one side top corner of the window opening and they propagated up to top layer of the wall. Run 34 - Cracks were observed from all corners of the window opening and they propagated to corners of the wall. Run 40 - A long horizontal crack at the top part and couple of vertical cracks were observed in south wall. Cracks appeared in the bottom layer of the east wall propagated through to whole wall. Run 43 - much more cracks were observed in the above part of the openings. Even though cracks propagated more wider at this level compared with non-retrofitted model, there was no brick fallen down from the wall observed. Run 49 - Although almost all the mortar joints were cracked at the end of this run, the specimen did not lose stability. Run 53 - Even some local failure was observed closer to door opening, the specimen did not lose stability. This input motion was 1.3 times larger acceleration and 2.7 times larger displacement than the input motion was applied in the Run 45. Another important point to mention was that the retrofitted model could sustain 8 more runs with higher input energy before this run. Fig. 8 Crack patterns observed on retrofitted model after Run 22 Fig. 9 Crack patterns observed on for retrofitted model after Run 40

Fig. 10 Retrofitted model after Run 45 Fig. 11 Retrofitted model after Run 52 At the final stage of the test, Run 53, with 50.6 mm base displacement, 8 times larger input displacement and 2.7 times larger input velocity than the Run 45 was applied. At this stage, most of the brick joints were cracked and the building had substantial permanent deformations. However, building did not loose the overall integrity as well as stability and collapse was prevented in such a high intensity of shaking. Thus, we could say that, PP-band retrofitting technique could maintain the integrity of the structural elements. Further, the retrofitted model showed the better energy dissipation mechanism as many new cracks were propagated without loosing the overall integrity and stability of the structure. 5. ANALYSIS ON TEST RESULTS The performances of the models were assessed based on the damage level of the buildings at different levels of shaking. Performances were evaluated in reference to five levels of performances: light structural damage, moderate structural damage, heavy structural damage, partially collapse, and collapse. Table 3 Damage categories Category Damage extension D0: No damage No damage to structure D1: Light structural damage D2: Moderate structural damage D3: Heavy structural damage Hair line cracks in very few walls. The structural resistance capacity did not decrease noticeably. Small cracks were observed on masonry walls. The structure resistance capacity decreased partially. Large and deep cracks were observed on masonry walls. Some bricks are fallen down. Failure in connection between two walls. D4: Partially collapse Serious failure and Partial structural failure were observed on walls and roofs, respectively. The building was in dangerous condition D5: Collapse Structure is totally or partially collapsed. 5.1. BASED ON JMA SCALE The Japan Meteorological Agency seismic intensity scale (JMA) is a measure used in Japan to indicate the strength of earthquake ground motions. Fig. 12 shows the performances of model houses with different JMA intensities. Collapse of the non-retrofitted building was observed at the 45 th run at intensity JMA 5-. The retrofitted building performed moderate structural damage level at the 45 th run

at which the non-retrofitted building was collapsed. Moreover, moderate structural damage level of performance was maintained until the 50 th run. It should be noted again that this model survived 8 more shakings in which many runs were with higher intensities than JMA 5- at which the non-retrofitted building was totally collapsed before reaching to the final stage at the 53 rd run. Nonretrofitted Retrofitted Fig. 12 Performance evaluation based on JMA Scale From these results it can be concluded that a structure retrofitted with PP-band meshes would be able to resist against strong aftershocks. Moreover, it proves that even though houses retrofitted with PP-band were cracked due to strong earthquake, it could be repaired and be expected to withstand subsequent strong shakes. 5.2. BASED ON ARIAS INTENSITY SCALE The Arias intensity was initially defined by Arias (Arias A., 1970) as t 2 I a a ( t) dt (1) 2g 0 and was called scalar intensity. It is directly quantifiable through the acceleration record a(t), integrating it over the total duration of the shaking. The arias intensity is claimed to be measure of the total seismic energy absorbed by the ground. Fig. 13 Performance evaluation based on arias intensity scale

Fig. 13 shows the performance levels of each specimen against dynamic motion based on arias intensity scale. Form the results, retrofitted model damage level performance was at least 3 times better than that of non-retrofitted model 6. CONCLUSIONS This paper discusses the results of shaking table tests that were carried out using non-retrofitted and retrofitted wallettes by PP-band meshes. The shaking table tests showed that; The effect of the PP-band meshes was not observed before the appearance of initial cracking. However, after cracking, they effectively helped to increase the ductility of walls parallel to the shake direction, i.e. subjected to in-plane loading, to prevent the toppling of the walls perpendicular to the shake, i.e. subjected to out-of-plane loading, and to keep the integrity of the structure by limiting corner damage. With this mechanism, PP-band mesh could avoid the typical failure modes observed in masonry structures. A scaled dwelling model with PP-band mesh retrofitting was able to withstand larger and more repeatable shaking than that without PP band retrofitting. Considering the easiness of installation and inexpensiveness of PP-band mesh, it can be considered as one of the best solutions to overcome the quality deficit of existing building stock in developing countries and therefore reduce the number of human fatalities in future seismic events. From the all experimental results, it was found that PP-band retrofitting technique proposed can enhance safety of both existing and new masonry buildings even in the worst case scenario of earthquake ground motion like JMA 7 intensity. Therefore proposed method can be one of the optimum solutions for promoting safer building construction in developing countries and can contribute earthquake disaster in future. REFERENCES Mayorca P., and Meguro K., (2004). Proposal of an efficient technique for retrofitting unreinforced masonry dwellings, 13th Conference on Earthquake Engineering, Vancouver, Canada, Paper No.2431. Roko Zarnic, Samo Gostic, Adam J. Crewe and Colin A.Taylorm, (2001). Shaking Table Tests of 1:4 Reduced Scale Models of Masonry Infilled Reinforced Concrete Frame Buildings, Earthquake Engineering and Structural Dynamics, Vol.30, 819-834. Alidad Hahemi and Khalid M.Mosalam, (2006). Shake-table Experiment on Reinforced Concrete Structure Containing Masonry Infill Wall, Earthquake Engineering and Structural Dynamics. Vol 35, Page 1827-1852. Arias, A. (1970). A Measure of Earthquake Intensity, R.J. Hansen, ed. Seismic Design for Nuclear Power Plants, MIT Press, Cambridge, Massachusetts, Page 438-483.