Your full service light gauge steel manufacturer

Similar documents
SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

SECTION COLD-FORMED METAL TRUSSES

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING

A. Product Data: For each type of cold-formed steel framing product and accessory.

SECTION COLD-FORMED METAL FRAMING

A. Section Metal Decking. (05300 in MF95) B. Section Cold Formed Metal Framing. (05400 in MF95)

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

SECTION COMPOSITE METAL DECKING

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

A. The work under this section consists of furnishing and installing gauge steel framing and bracing as indicated on the drawings and as specified.

SECTION (05300) - STEEL DECKING

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING

SECTION STEEL DECKING

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

SECTION: COLD-FORMED METAL JOIST FRAMING

SECTION COMPOSITE METAL DECKING

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

BEARING METAL STUD FRAMING

Architectural Wall Products Guide Specifications

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

SECTION METAL DECKING. A. Extent of metal decking is indicated on Plans, including basic layout for the following type of deck required:

SECTION NON-STRUCTURAL METAL FRAMING

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION METAL STAIRS

SECTION STEEL JOIST FRAMING

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION SHOP-FABRICATED WOOD TRUSSES

SECTION METAL STAIRS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

2016 CDM Smith All Rights Reserved July 2016 SECTION STEEL ROOF DECK

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

Architectural Roof and Wall Products Guide Specifications

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

SECTION ORCHESTRA PIT FILLER

SECTION (05400) - COLD-FORMED METAL FRAMING

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

SECTION COLD-FORMED METAL FRAMING

SECTION AWNINGS

Architectural Roof Products Guide Specifications

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

SSL-175. Specifications

A. Provide all wood trusses as indicated on the drawings or as required to do a complete job.

A. Product Data: For each type of deck, accessory, and product indicated.

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

PART 1 GENERAL SHOP FABRICATED WOOD TRUSSES

Architectural Roof Products Guide Specifications

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

TECHNICAL NOTE On Cold-Formed Steel Construction

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Architectural Roof and Wall Products Guide Specifications

SECTION COLD-FORMED METAL FRAMING

SECTION METAL WALL PANEL SYSTEM

DIVISION 5 METALS SECTION METAL DECKING

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION ALTERNATING TREAD STEEL STAIRS

STRUCTURAL STEEL FRAMING

SECTION (10705) EXTERIOR SUN CONTROL DEVICES

SECTION NON-STRUCTURAL METAL FRAMING

UNISTRUT CORPORATION GENERAL NOTES 1. THIS UNISTRUT SUPPORT SYSTEM IS DESIGNED TO SUPPORT A MAXIMUM UNIFORM LOAD OF PSF.

COMMENTARY TO ANSI/TPI/WTCA METAL PLATE CONNECTED WOOD TRUSSES Revised 2002

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION STRUCTURE MOUNT RAILING SYSTEM

Page 1 of 5

SECTION ARCHITECTURAL PRECAST CONCRETE. C. Section Joint Sealers: Perimeter joints with sealant and backing.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

SECTION: STRUCTURAL METAL STUD FRAMING

Preassembled steel stairs with concrete-filled treads.

DIVISION 5 METALS SECTION STRUCTURAL STEEL

Stone and Masonry Veneer

SECTION NON--STRUCTURAL METAL FRAMING

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

DIVISION 5 METALS BUSHEY FEIGHT MORIN ARCHITECTS INC. 473 NORTH POTOMAC STREET HAGERSTOWN, MARYLAND FAX:

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ALTERNATING TREAD STEEL STAIRS

DL-200. Specifications

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

Architectural Roof and Wall Products Guide Specifications

Long Span Truss Installation

SECTION PRE-ENGINEERED METAL BUILDING

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

Transcription:

Your full service light gauge steel manufacturer In addition to roof trusses, Superior Truss also supplies: q Light gauge steel floor trusses with metal decking and/or plywood sheathing q Light gauge steel C -stud load and non-load bearing wall panels q Light gauge steel residential framing q Residential light gauge steel basement wall systems q Light gauge steel modularized residential units q Non-combustible roof deck systems q Operates out of a 92,000 square foot facility on 10 acres of land q Complete installation services of all our products is available Proud Fabricators of Mitek Industries, Inc. Ultra-Span Light Gauge Steel Truss System www.mitekinc.com CONNECTION DETAILS AND SPECIFICATIONS AT www.superior-truss.com CLASSIFIED Section 05410 General Specifications UL Specification P521 Mitek Ultra-Span Technical Information CLASSIFIED Connection Details in AutoCad Format UL Specification P523 List of Projects SUPERIOR TRUSS & PANEL, INC. 2204 West 159th Street Markham, Illinois 60426 PH (708) 339-1200 FAX (708) 339-1248 www.superior-truss.com info@superior-truss.com

America s Largest Fabricator and Erector of Light Gauge Steel Trusses and Wall Panels SUPERIOR TRUSS & PANEL, INC. 2204 West 159th Street Markham, Illinois 60426 PH (708) 339-1200 FAX (708) 339-1248 www.superior-truss.com info@superior-truss.com Light Gauge e St S eel Roof Tr T usses

Transportation to the jobsite Superior Truss & Panel offers a complete package including manufacturing, installation and transportation. We own and operate our private fleet of trucks. As such, dependable on-time delivery to your job site is assured, and the risk associated with transferring our material to a common carrier is eliminated. We control the entire process from planning, manufacturing, transportation and installation. This aids in higher quality product transported and installed by the company that built it. The same high quality that leaves our facility will be delivered to your site, ready for installation. We take pride in controlling the entire process. This ensures our customer receives the highest quality available along with the piece of mind knowing that they have one supplier handling everything on their behalf. The need for multiple subcontractors is eliminated, thus aiding in efficiency. Weather Don t let your project get held up because of weather conditions. The very nature of our material allows for ease of installation in most weather climates. In addition to the many benefits of light gauge steel, our roof trusses can be installed during many climate conditions which will aid in the erection and enclosing your structure quicker.

Installation Purchasing your light gauge steel roof trusses from Superior Truss & Panel is only half the task. Allowing our dedicated crew to install the trusses will ensure the job is completed right the first time. Installation is an optional service offered, but we are sure you will be glad you chose Superior Truss to complete this portion of your project. We take pride in controlling the entire process and rendering a Superior product and service. We work with you from design, manufacturing, installation and transportation. Superior guarantees our work and you will have peace of mind knowing your roof trusses were installed correctly the first time. Bracing and Erection During the installation phase, proper construction and permanent bracing are the major keys to a successful erection. Improper bracing is the leading cause for collapsed trusses during erection. Superior takes pride in its bracing techniques and has adopted the guidelines as published by the Light Gauge Steel Engineers Association as its installation guidelines. Proper installation bracing depicted above which will guard against buckling, bending and collapse. f Light Gauge Steel Trusses and Wall Panels

Engineering Services provided by MiTek Industries, Inc. Superior Truss is willing and able to provide the engineer of record with a manufacturer that has the ability to take the full engineering responsibility for their product. Our engineering services, provided by MiTek Industries, Inc., can include an engineering stamp for the complete roofing system in all 50 states. This stamp, will ensure the design has all the elements outlined in the specifications. We will provide a Complete Structural Roof System A light gauge steel structural roof system consists of: Does your light gauge steel roof consist of the following components? If not, it may not meet building code requirements. q Light gauge steel trusses q Truss permanent and installation bracing q Truss connections: truss to truss & truss to structure q Roof deck assembly q Roof deck shear transfer framing q Eave edge structural supports q Valley, hip and ridge structural supports The 7 elements above form a Complete Structural Roof System Through MiTek s engineering, we will provide the following to ensure your roof meets the code: 1. Light gauge steel trusses that support vertical loads both up and down, transfer of lateral loads and provide proper bearing for roof and floor decks. 2. Truss permanent and installation bracing to prevent chord and web buckling. 3. Truss connections that resist gravity, wind and seismic loads. 4. Roof deck assembly that supports both uniform and concentrated vertical loads; the deck also acts as a shear diaphragm resisting seismic or wind loads. 5. Shear transfer framing that collects roof deck shear and transfers it to the building structure below. 6. Eave edge structural supports that collect shear from the roof deck and supports concentrated and uniform loads at the roof edge 7. Valley, hip and ridge structural supports that transfer shear across the roof deck transition planes and supports the concentrated and uniform loads. America s Largest Fabricator and Erector of

Specifications: Section 05410 Pre-engineered, pre-fabricated light gauge steel roof & floor trusses PART 1: GENERAL 1.01 SUMMARY A. Section includes pre-engineered, pre-fabricated light gauge cold-formed steel framing elements. Work includes: 1.Light gauge cold-formed steel roof trusses. 2.Light gauge cold-formed steel open web floor trusses. 3.Anchorage, bracing and bridging. B. Related Work 1.Drywall attachment. 2.Roofing, fascia and soffit. 1.02 REFERENCES A. Reference standards: 1. ASTM: a. ASTM A653/A653M-94 Sheet Steel, Zinc-Coated (galvanized) or Zinc-Iron Alloy-Coated (Galvanized) by the Hot- Dip Process. b. ASTM A780-93a Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings. 2. American Welding Society (AWS) a. AWS D1.1 Structural Welding Code - Steel. b. AWS D1.3 Structural Welding Code - Sheet Steel. 1.03 PERFORMANCE REQUIREMENTS A. AISI Specifications. Calculate structural characteristics of cold-formed steel truss members according to AISI s Specification for the Design of Cold-Formed Steel Structural Members, 1986 (1990). B. Structural Performance: Design, engineer, fabricate, and erect cold-formed steel trusses to withstand specified design loads within limits and under conditions required. 1.Design Loads: As specified. 2.Deflections: Live load deflection meeting the following (unless otherwise specified): a.floor Trusses: Vertical deflection less than or equal to 1/360 of the span b.roof Trusses: Vertical deflection less than or equal to 1/240 of the span 3.Design framing systems to provide for movement of framing members without damage or overstressing, sheathing failure, connection failure, undue strain on fasteners and anchors, or other detrimental effects when subject to a maximum ambient temperature change (range) of 120( F (67(C). 4.Specifically, the prefabricated light gauge steel roof truss manufacturer (vendor) shall provide the following services: a.design and supply a complete light gauge steel roof system stamped by a registered engineer to include all of the following components: 1.) Light gauge steel trusses for gravity and lateral loads with truss sizes, gauges and connections at truss joints. 2.) Design and stamp truss to truss connections and truss to bearing connections for gravity, lateral and uplift loads. 3.) Design and stamp the top cord, bottom cord and permanent bracing locations. 4.) Design and stamp the roof deck structural support at eave edge, valley, hip and ridge transition planes to support corrugated steel or plywood decking. 5.) Design the roof deck shear transfer framing required to transfer the roof deck shear to the building structure. The Engineer-Of-Record or Architect is responsible to determine the roof diaphragm, to determine the location and magnitude of the roof shear transfer and to determine location within the building structure through which this shear will pass. b.provide stamped calculations and shop drawings for project submittal requirements as a building component. 1.04 SUBMITTALS A. Submit manufacturer s product data and installation instructions for each type of cold-formed steel framing and accessory required. B. Submit shop drawings showing member, type, location, spacing, size and gauge of member, method of attachment to supporting members and all necessary details. Indicate supplemental bracing, strapping, splices, bridging, accessories and details required for proper installation. C. Submit detailed floor truss and roof truss layouts. D. Submit truss drawings, sealed and signed by a qualified registered Professional Engineer, verifying the truss ability to meet local code and design requirements. Specifically include the engineering and design for all of the following: 1.Description of design criteria. 2.Engineering analysis depicting member stresses and truss deflection 3.Truss member sizes, gauges and connections at truss joints; truss to truss attachment details. 4.Truss reaction at all bearing locations; truss to bearing attachment details. 5.Top chord, bottom chord and web permanent bracing requirements; construction and temporary bracing per the Light Gauge Steel Engineers Association (LGSEA) Field Installation Guidelines dated October 1999. 6.Eave edge, valley, hip and ridge structural support for roof corrugated or plywood decking. 7.Roof deck shear transfer framing required, transfering the roof deck shear to the building structure. 1.05 QUALITY ASSURANCE A. Fabricator Qualifications: Fabrication shall be performed by a cold-formed steel truss fabricator with experience in designing and fabricating cold-formed steel truss systems equal in material, design, and extent to the systems required for this Project. 1.Cold-formed steel truss system installation shall be performed by an experienced installer approved by the steel truss system fabricator. B. Welding Standards: Comply with applicable provisions of AWS D1.1 Structural Welding Code-Steel. And AWS D1.3 Structural Welding Code-Sheet Steel. 1.Quality welding processes and welding operators in accordance with AWS Standard Qualification Procedure. 2.Welding of any nature to these trusses is specifically prohibited unless permission is received from the manufacturer. 1.06 DELIVERY, STORAGE AND HANDLING A. Deliver materials in manufacturer s unopened containers or bundles, fully identified by name brand, type and grade. Exercise care to avoid damage during unloading, storing and erection. B. Store trusses on blocking pallets, platforms or other supports off the ground and in an upright position sufficiently braced to avoid damage from excessive bending. C. Protect trusses and accessories from corrosion, deformation, damage and deterioration when stored at job site. Keep trusses free of dirt and other foreign matter. 1.07 PROJECT CONDITIONS A. During construction, adequately distribute all loads applied to trusses so as not to exceed the carrying capacity of any one joist, truss or other component PART 2: PRODUCTS 2.01 MANUFACTURERS A. Acceptable truss manufacturers for light gauge metal trusses: 1.MiTek Industries, Inc. Ultra-Span truss component system. Fabrication and installation by: Superior Truss & Panel, Inc. 2204 West 159th Street Markham, Illinois 60426 Ph. 708-339-1200 Fx. 708-339-1248 Contact: Mike Goncher or Bryce Welty 2.02 COMPONENTS A. System components: MiTek Industries, Inc. ULTRA-SPAN Light gauge steel roof trusses and floor truss components. B. Provide manufacturer s standard steel truss members, bracing, bridging, blocking, reinforcements, fasteners and accessories with each type of steel framing required, as recommended by the manufacturer for the applications indicated and as needed to provide a complete light gauge cold-formed steel truss system. 2.03 MATERIALS A. Materials: 1.All component gauges: Fabricate components of structural quality steel sheet per ASTM A653 with a minimum yield strength of 40,000 psi. 2.Bracing, bridging and blocking members: Fabricate components of commercial quality steel sheet per ASTM A653 with a minimum yield strength of 33,000 psi. B. Ultra-Span steel truss components: Provide sizes, shapes and gauges indicated. 1.Design Uncoated-Steel Thickness: 20 gauge, 0.0360 inch (0.91 mm). 2.Design Uncoated-Steel Thickness: 18 gauge, 0.0470 inch (1.20 mm). 3.Design Uncoated-Steel Thickness: 16 gauge, 0.0580 inch (1.52 mm). 4.Design Uncoated-Steel Thickness: 14 gauge, 0.0750 inch (1.90 mm). C. Finish: Provide components with protective zinc coating complying with ASTM A653, minimum G60 coating. D. Fastenings: 1.Manufacturer recommended self-drilling, self-tapping screws with corrosion-resistant plated finish. Fasteners shall be of sufficient size and number to ensure the strength of the connection. 2.Welding of any nature to these trusses is specifically prohibited unless permission is received from the truss manufacturer. 3.Other fasteners as accepted by truss engineer. 2.04 FABRICATION A. Factory fabricate cold-formed steel trusses plumb, square, true to line and with connections securely fastened, according to manufacturer s recommendations and the requirements of this Section. 1.Fabricate truss assemblies in jig templates. 2.Cut truss members by sawing or shearing or plasma cutting. 3.Fasten cold-formed steel truss members by screw fastening, or other methods as standard with fabricator. Wire tying or welding of framing members is not permitted. a.locate mechanical fasteners and install according to coldformed steel truss component manufacturer s instructions with screw penetrating joined members by not less than 3 exposed screw threads. B. Care shall be taken during handling, delivery and erection. Use of a crane or lull with a spreader bar is recommended for trusses longer than 30 foot. Brace, block or reinforce truss as necessary to minimize member and connection stresses. C. Fabrication Tolerances: Fabricate trusses to a maximum allowable tolerance variation from plumb, level, and true to line of 1/8 inch in 10 feet (1:960) and as follows: 1.Spacing: Space individual trusses no more than plus or minus 1/8 inch (3mm) from plan location. Cumulative error shall not exceed minimum fastening requirements of sheathing or other finishing materials. 2.Sequences: Fabricate each cold formed steel truss to a maximum out-of-square tolerance of 1/8 inch (3mm). For a Complete Specification Sheet Please Contact us at (708) 339-1200 or download from our website www.superior-truss.com info@superior-truss.com

Why choose Superior? We are a full service light gauge steel truss manufacturer with exceptional and unparalleled services that include: q FREE assistance to architects, engineers and contractors q Engineering stamps on shop drawings from MiTek Industries, Inc. for all 50 states q Fully computerized designs with detailed layout drawings using MiTek 2020 Steel Design software q Deliveries to all areas nationwide using our transportation equipment q Complete installation services with our erection crews This Chicago Housing Authority Project included a complete roof truss system assembled at our facility, shipped and hoisted into place, yielding exceptional quality at a lower cost with quicker installation time. The Landing Retirement Facility in Lincoln, NE shows our trusses during delivery, installation and completion. The Chapel Lawn Funeral Home in Schererville, IN includes a skylight built directly into the truss (left), as detailed above.

Superior offers a complete system After our trusses are installed, we can complete the entire roofing structure inclusive of metal decking, plywood sheathing or a 100% non-combustible roofing system. You will rest easy knowing the entire complete roofing structure, ready to receive felt paper, will be completed and installed by one subcontractor. Example of a 100% non-combustible roof structure over light gauge steel trusses. Corrugated metal deck installed over trusses. Benefits Superior Truss, has available through MiTek Industries, UL listed products offering 1hour, 1-1/2 and 2 hour fire rated assemblies. In addition, light gauge steel roof trusses have the many benefits listed: The Fanning Oil Building in Jacksonville, IL (above & below) illustrates unique designs for circular and sloped roofs. q 100% non-combustible q Clear spans up to 80 feet q Versatile, steel trusses can be fabricated in endless unique designs q Easy handling, light gauge steel is 35-40% lighter than wood q Weather resistant, steel will not warp, expand or rot q Galvanized G-60 or G-90 steel to resist corrosion q Increased strength to weight ratio q Quick and easy installation q Prefabricated assemblies reduces erection time and field installation labor hours Light gauge steel trusses have excellent connection capabilities to a variety of substrates, including concrete and structural steel. q Environmentally friendly, steel is 100% recyclable