Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02
U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380 609-419-4241 www.mieleusa.com Technical Service & Support Nationwide Phone: 800-991-9380 Fax: 800-220-1348 proservice@mieleusa.com It is essential to read the operating and installation instructions before installing, commissioning or using the machine. This avoids the risk of accidents or damage. All rights reserved Mat. NR. 09 883 210 / 02 2
Technical datasheet Tumble dryer: Heating: PT 8807 Electric (EL) Legend: Abbreviations in bold type: Connection required en - US Abbreviations in circle with dashes: Connection optional or required depending on model version Optional extras: BS Concrete base Quality and density of concrete must comply with load. Concrete plinth must be firmly secured to floor! Recommended height mm 100 4 Minimum height mm 50 2 Minimum width mm 1.200 47 Minimum depth mm 1.400 55 Machine connections: Electrical connection Voltage V 3 AC 208 Frequency Hz 60 Rated load kw 27.4 Fuse rating A 3 90 Connection cable, min. cross-section mm² AWG 16 Cable screw connector M 50 Connection cable to be ordered separately. Electrical connection must comply with national regulations If machines are hard-wired, a multi-pole main switch must be provided on site. A wall socket or main isolator must be accessible after installation. Equipotential bonding Peak load energy management Connection with male thread mm 10 35 with washers and nut M 10 Accessories not included. If necessary, equipotential bonding with good galvanic contact must be provided in accordance with all appropriate national and local regulations. Control contact voltage V AC 230 Connection cable, min. cross-section mm² 5 1,5 Connection cable to be ordered separately. Connection via a flexible supply lead with a separate isolator is recommended. The isolator should be visible and easily accessible after machine installation. Vented Max. Nominal air flow in vented mode m³/h 1.100 38,85 cu ft/h Max. Permissible pressure loss Pa 300 0.04 PSI Connection on machine side (ext. diameter) mm 150 6 Connection pipe provided on site (int. diameter) mm 150 6 Max. temperature C 80 176 F As relative humidity inside the vent ducting can be as high as 100%, suitable measures must be taken to prevent a backflow of condensate into the machine. Installation plan: PT 8807 EL Date: 2015-Sep-15 Page: 8
Air intake Standard connection: Air intake from installation site Unobstructed air intake into room recommended (corresponding to 3 times the vent cross-section of machine) A sufficient supply of fresh air should be ensured to replace the air extracted. cm² 531 32 cu in Alternative connection: Ducted air intake (from outside building) Connector on machine (int. diameter) mm 161 6 ½ Connection pipe provided on site (ext. diameter) mm 160 6 ¼ Lid removal exposes live components! For safety reasons, the pipe connected for central air intake should be at least 900 mm long and secured using two screws. Fittings (supplied) Without base 2 clamps 2 screws DIN 571 (Ø length) 2 rawl plugs (Ø length) The machine should be bolted to the floor. Fixing materials for a floating screed floor are to be provided on site. On concrete platform 2 clamps 2 screws DIN 571 (Ø length) 2 rawl plugs (Ø length) The machine must be bolted to the floor! Fixing materials for a floating screed floor are to be provided on site. mm 6 40 mm 10 50 mm 6 40 mm 10 50 Machine data Unit width mm 1.206 47 ½ Machine depth mm 1.384 54 ½ Unit height mm 1.640 64 ½ Casing width mm 1.200 47 ¼ Casing depth mm 1.279 50 ½ Minimum width of delivery access to installation site mm 1.220 48 Recommended rear wall gap (measured to front of mm 1.800 71 machine) Min. wall gap (to rear edge of lid) mm 500 19 ¾ Net weight kg 287 632 lb Max. load bearing in operation N 3.708 Average heat dissipation Watt 973 (dependent on ambient room temperature and program selected) A Noise level db (A) 73,6 A Sound pressure level db (A) 62 Installation should only be carried out by authorised installers in accordance with all local and national regulations! Follow installation instructions when installing machine. All rights reserved. Measurements in millimeters [inches]. Installation plan: PT 8807 EL Date: 2015-Sep-15 Page: 9