Mobile Sensor that Quickly and Selectively Measures Ammonia Gas Components in Breath

Similar documents
6.1 Summary. Summary and Scope for Further Study

Thin Film Gas Sensor. Nanoelectronics and MEMS Laboratory National Electronics and Computer Technology

Water Vapor and Carbon Nanotubes

Metallization deposition and etching. Material mainly taken from Campbell, UCCS

Improvement of gas barrier properties by combination of polymer film and gas barrier layer

Fabrication of MoS 2 Thin Film Transistors via Novel Solution Processed Selective Area Deposition

A NOVEL METHOD FOR THE IMPROVEMENT IN THERMOELECTRIC PROPERTY OF TIN OXIDE THIN FILMS AND ITS APPLICATION IN GAS SENSING

Real-time analysis of VOCs in human breath, using SIFT-MS

Effect of substrate heating on elimination of pinholes in sputtering deposited SiO2 films on LiNbO3 single crystal substrates

Nanoscale Imaging, Material Removal and Deposition for Fabrication of Cutting-edge Semiconductor Devices

Silver Diffusion Bonding and Layer Transfer of Lithium Niobate to Silicon

Development of Polyaniline Based Gas Sensor

Supplementary Information

Wearable Biosensors for Personalized Health Monitoring Wei Gao

ITO. Crystal structure: Cubic, space group Ia3 No. 206, ci80, a = nm, Z = 16

Development of Low-resistivity TiN Films using Cat Radical Sources

Introduction. 1. Sputtering process, target materials and their applications

Chapter 3 Silicon Device Fabrication Technology

III Fabrication of the samples

GROWTH AND CHARACTERIZATION OF NANOSTRUCTURED CdS THIN FILMS BY CHEMICAL BATH DEPOSITION TECHNIQUE

NO x gas response characteristics of thin film mixed oxide semiconductor

Electroplating Engineers of Japan Develops Innovative Direct Patterning Plating Technology that Opens the Potential of New-Generation Electronics

RF REACTIVE SPUTTERING OF MOO3 THIN FILMS FOR SENSOR APPLICATIONS

Platypus Gold Coated Substrates. Bringing Science to the Surface

OXYGEN SENSOR BASED ON Ga 2 O 3 FILMS OPERATING AT HIGH TEMPERATURE

Provided for non-commercial research and education use. Not for reproduction, distribution or commercial use.

Etching Mask Properties of Diamond-Like Carbon Films

Novel Fuel Cell MEA Based on Pt-C Deposited by Magnetron Sputtering

Microelectronics. Integrated circuits. Introduction to the IC technology M.Rencz 11 September, Expected decrease in line width

UTILIZATION OF ATMOSPHERIC PLASMA SURFACE PREPARATION TO IMPROVE COPPER PLATING PROCESSES.

2 Boar s Head Lane Charlottesville, VA Phone Fax

Sensing of carbon monoxide gas in reducing environments $

Productivity versus Profitability in Vacuum Web Coating

Growth of monocrystalline In 2 O 3 nanowires by seed orientation dependent vapour-solid-solid mechanism

Mat E 272 Lecture 26: Oxidation and Corrosion

Mater. Res. Soc. Symp. Proc. Vol Materials Research Society

EE 5344 Introduction to MEMS. CHAPTER 3 Conventional Si Processing

Gas and surface applications of atmospheric pressure plasmas

MARORA A Plasma Selective-oxidation Apparatus for Metal-gate Devices

Fabrication and Characterization of a Polypyrrole Coated Copper Nanowire Gas Sensor

1a Elements and their combinations account for all the varied

sensors ISSN by MDPI

Electricity and Chemistry

MoS 2 film thinning on high-temperature sputtering for enhancement-mode nmosfets

Development of New Generation Of Coatings with Strength-Ductility Relationship, Wear, Corrosion and Hydrogen Embrittlement Resistance Beyond the

Lateral epitaxial growth of two-dimensional layered semiconductor heterojunctions

Literature Review Breath Analysis Harvard Referring

Optimization of ZnO Seed Layer for Growth of Vertically Aligned ZnO Nanorods on Glass Surface

Oligomer-Coated Carbon Nanotube Chemiresistive Sensors for Selective Detection of Nitroaromatic Explosives

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

Vacuum Deposited Polyimide Layers as Humidity Sensors

Nemoto Sensor Engineering Company Ltd

SYNTHESIS AND CHARACTERIZATION OF LEAD ZIRCONATE BY HOMOGENEOUS PRECIPITATION AND CALCINATIONS

Fabrication of Ru/Bi 4-x La x Ti 3 O 12 /Ru Ferroelectric Capacitor Structure Using a Ru Film Deposited by Metalorganic Chemical Vapor Deposition

Pre-treatment of low temperature GaN buffer layer deposited on AlN Si substrate by hydride vapor phase epitaxy

INFLUENCE OF CRYSTALLINE STRUCTURE AND PARTICLE SIZE OF VAPOR CORROSION INHIBITOR POWDERS ON THEIR INHIBITING EFFECTIVENESS

ENS 06 Paris, France, December 2006

Synthesis, Characterization and Optical Properties of ZnS Thin Films

Printed circuit board surface finish and effects of chloride contamination, electric field, and humidity on corrosion reliability

Applied Research for Vacuum Web Coating: What is Coming Next?

SUPPLEMENTARY INFORMATION

INSTRUMENTATION FOR MEASUREMENT OF THE EFFECTIVENESS OF VAPOR CORROSION INHIBITORS

Simulation of Cantilever Based Sensors for Smart Textile Applications

EECS130 Integrated Circuit Devices

Tin Coated Viral-Nanoforests as Sodium-Ion. Battery Anodes

Field-Effect Transistor with Deposited Graphite Thin Film. Research Institute of Electronics, Shizuoka University, Johoku, Naka-ku, Hamamatsu

Composition Control of Pd-Cu-Si Metallic Glassy Alloys for Thin Film Hydrogen Sensor

Microelettronica. Planar Technology for Silicon Integrated Circuits Fabrication. 26/02/2017 A. Neviani - Microelettronica

Using Argon Plasma to Remove Fluorine, Organic and Metal Oxide Contamination for Improved Wire Bonding Performance

Retarding the crystallization of PbI 2 for highly reproducible planarstructured perovskite solar cells via sequential deposition

1 MARCH 2017 FILM DEPOSITION NANOTECHNOLOGY

DEPOSITION AND CHARACTERISTICS OF TANTALUM NITRIDE FILMS BY PLASMA ASSISTED ATOMIC LAYER DEPOSITION AS CU DIFFUSION BARRIER

Formation of Droplets on Thin Film Surface in Pulsed Laser Deposition Using Metal Targets*

Grain Sizes and Surface Roughness in Platinum and Gold Thin Films. L.L. Melo, A. R. Vaz, M.C. Salvadori, M. Cattani

Healthcare. Healthcare. The Centre for Process Innovation. From innovation to commercialisation

Synthesis and Characterization of Cadmium Sulfide Nanoparticles

High Thermal Conductivity Silicon Nitride Ceramics

SYNTHESIS OF SnO 2 NANORODS BY HYDROTHERMAL METHOD FOR GAS SENSOR APPLICATION

Check your ALCE Reading Skills: Activity 2. Key and item analysis

Deposited by Sputtering of Sn and SnO 2

Fabrication of Single-Layer Touch Screen Panel with Corrosion Resistant Metal-Mesh Electrodes

The Proper Mechanism for Field Validating Moisture Analyzers. GE Measurement & Sensing GE Oil & Gas

Electrochemical Green Engineering Group

arxiv:cond-mat/ v2 [cond-mat.mtrl-sci] 29 Nov 2003

X-ray Photoelectron Spectroscopy

SUPPLEMENTARY INFORMATION

Synthesis and Evaluation of Electrocatalysts for Fuel Cells

MASTER'S THESIS. Synthesis of rare-earth oxide mesoporous structures by combustion synthesis

MILESTONE REPORT # 1

2.3 Quantum Dots (QDs)

New SaaS-based Operations Management System to Realize Safe Driving Support and Improve Transport Quality: Logifit TM-NexTR

There are basically two approaches for bulk micromachining of. silicon, wet and dry. Wet bulk micromachining is usually carried out

Summary of Antimony Work

Development of digital moisture meter for jute fibre and its products

Guideline Regarding Non-Containment Management on Fujitsu Group Specified Chemical Substances

Lect. 2: Basics of Si Technology

An XPS and Atomic Force Microscopy Study of the Micro-Wetting Behavior of Water on Pure Chromium* 1

Design. Finish. The SL-2012A provides in-situ Optical Monitoring and Rate Control.

Pulsed Laser Deposition of Epitaxial Titanium Nitride on Magnesium Oxide substrate

VLSI. Lecture 1. Jaeyong Chung System-on-Chips (SoC) Laboratory Incheon National University. Based on slides of David Money Harris

Transcription:

Mobile Sensor that Quickly and Selectively Measures Ammonia Gas Components in Breath Osamu Tsuboi Satoru Momose Ryozo Takasu Amid the increasing trend of aging societies across the world, there are now expectations for healthcare tailored to individuals that helps to more quickly detect diseases and improve lifestyles to ensure health and longevity for the current generation. Therefore, it is thought that it will be effective to use device technology and information and communications technology (ICT) to monitor an index related to the state of the body, easily and continuously in the home, clinic, and such like. We have focused research on diagnostic methods using breath analysis to examine the gaseous components of a person s breath as an indicator of the condition of his or her body, and developed a mobile breath sensor. This paper describes a breath sensor system that can selectively measure the concentration of ammonia that is present in everyone s exhaled breath. By applying the ammonia-adsorbing characteristic of copper(i) bromide films, we successfully developed a sensor that measures tiny amounts of ammonia in a person s breath at a sensitivity differential that is more than treble that of a gas having other living body origins. By using the sensor device, we have developed a breath sensor system. As a result, it has become possible to continuously and easily examine changes in components of the breath in relation to lifestyle without any accompanying pain such as the pain of collecting blood, similar to using a clinical thermometer. 1. Introduction Amid the increasing trend of aging societies across the world, both the increase in overall medical costs and the decrease in work force have become serious problems at the state level. In Japan, costs of medical treatment were in excess of 40 trillion yen, corresponding to 8% of GDP, in 2013. Lifestyle diseases such as high blood pressure and metabolic syndrome occupy a large percentage of such costs because they often lead to other serious diseases, and they can cause a large loss to society in both aspects of medical cost and work force. Early detection and treatment of lifestyle illnesses are being touted as the key to health and longevity for the current generation. New healthcare services are requested by using information and communications technology (ICT) including state-of-the-art devices to solve this issue. A person s breath includes many chemical substances that were in the blood but that evaporated in the lungs and were exhaled. By using breath analysis to measure the concentrations of these gases, the objective is to detect specified substances and effectively use that information for the early detection of lifestyle diseases, leading to improved lifestyle habits. 1) Breath analysis is non-invasive. This means, this technology makes it possible to avoid the unpleasantness of drawing blood while at the same time making it easier to study the effects of changes in breath components resulting from lifestyle habits, on an ongoing basis. Ammonia in a person s body is generated by intestinal bacterial decomposing nitrogen compounds such as proteins and amino acids. But ammonia is converted into urea in the liver and then expelled in urine. Therefore, the concentration of ammonia in the breath is kept low if a person is healthy. Ammonia in a person s breath is said to be correlated both with liver metabolism and Helicobacter pylori infection, which is a risk factor for stomach cancer. 2) It is reported that ammonia has a high possibility of being useful as a biomarker because it is increases when a person is tired and with aging. 38 FUJITSU Sci. Tech. J., Vol. 53, No. 2, pp. 38 43 (February 2017)

In this paper, we describe a mobile breath sensor that can measure changes in ammonia level caused by lifestyle. 2. CuBr: a novel ammonia sensing material A promising research result has reported on lung cancer detection using breath analysis and a pattern recognition approach, in which surface-modified gold nanoparticles were used as sensing material. 2) However, this kind of approach can only recognize known patterns, and thus unexpected abnormalities may be missed. The authors therefore focused on developing a sensing device to detect molecules and detect only ammonia, which is included in the breath in the order of 100 ppb (Figure 1). There are many semiconductor materials that indicate a response to ammonia. For example, widely used metal-oxide semiconductor gas-sensor devices can also detect ammonia. In these cases, the semiconductor devices are used at a high temperature of around 300 C to raise the carrier density amount of the current flowing in a semiconductor and surface activity. Such condition enables the devices to be sensitive to ammonia, similar to other kind of gases. For the molecular recognition approach, however, Blood-borne chemical substances partially vaporized in lungs Breath sensor Neither acetone nor ethanol is adsorbed Ammonia is adsorbed e Cu + Cu + CuBr film A it is ideal if the sensor device detects only ammonia, and shows no response to other gases. From the perspective of selectivity to ammonia, the authors chose copper(i) bromide (CuBr) as a sensing material. CuBr is known as a selective ammonia-sensing material; its response to ammonia is orders of magnitude higher than that for other gases. The difference in response magnitude among the gases can be explained by the fact that ammonia tends to link up with Cu+ ions and produce a complex. Since CuBr is a p-type semiconductor and a solid electrolyte, Cu+ ions in a crystal migrate to the surface with exposure to ammonia, and coordinately bond to ammonia molecules. As a result, the carrier density in CuBr crystals decreases because of an excess negative charge inside the crystals. 3) Accordingly, the sensitivity of a CuBr gas-sensor device is expected to improve with a decrease in the sensing film s thickness. However, the reported sensitivities of CuBr gassensor devices made by known fabrication procedures, brominating a Cu film in an aqueous solution of copper(ii) bromide (CuBr 2 ), 4) or sputtering, 5) are orders of ppm. This is because it is difficult to fabricate a thin and stable CuBr film with ppb orders of sensitivity. The authors therefore developed a novel procedure to fabricate a CuBr thin film, in which a thin Cu film is brominated with a CuBr 2 methanol solution. This procedure can fabricate a stable CuBr crystal structure because there is no variation in the chemical composition, unlike that which results from the sputtering method. Also, methanol has less affinity to CuBr than water. Therefore, stable CuBr films that are hard to be exfoliated can be created in the methanol solution procedure because smaller crystalline grains can be obtained than in the aqueous solution procedure. The procedure of fabricating a thin CuBr thin-film gas-senor device is as follows. 1) On a pair of gold electrodes, a 5 mm square copper film with a thickness of 60 nm is deposited by using the vacuum deposition technique. 2) The aforementioned structure is immersed into a CuBr 2 methanol solution with a concentration of 0.2 mol/l for 60 s, then washed with pure methanol and dried. The thickness of the obtained CuBr film is approximately 300 nm. Figure 1 Conceptual image of composition and usage of developed technology. FUJITSU Sci. Tech. J., Vol. 53, No. 2 (February 2017) 39

3. A highly sensitive and highly selective ammonia sensor device Figure 2 shows the appearance and crosssectional structure and a cross-sectional scanning electron microscope (SEM) image of the CuBr thinfilm gas-sensor device described in section2. Typical responses of the CuBr device to ammonia with various concentrations in the atmosphere are indicated in Figure 3. The range of ammonia concentration shown in Figure 3 is 100 1,000 ppb (0.1 1 ppm). As shown in Figure 3, the relationship between ammonia concentrations and the device response indicates good linearity up to 10 ppb, and this is an adequate sensitivity for measuring ammonia concentrations in human breath. Figure 3 also shows that the saturation values of the device resistance have a CuBr Au electrodes (a) Top view of a chip CuBr t: ~300 nm Au t: 60 nm Au t: 60 nm Gap: 1 mm SiO2 substrate (b) Cross-sectional structure CuBr SiO 2 1.50 µm (c) Cross-sectional SEM image of CuBr film Figure 2 Gas sensor device made from CuBr film. Change in resistance (%) 600 500 400 300 200 1,000 ppb 750 ppb 500 ppb 250 ppb Supply of ammonia stopped Change in resistance (%) 500 400 300 200 120 s 60 s 30 s 100 100 ppb 100 10 s 0 0 200 400 600 0 800 1,000 1,200 0 250 500 750 1,000 Time (s) (a) Time response Ammonia concentration (ppb) (b) Calibration curve Figure 3 Typical responses of sensor device to ammonia gas. 40 FUJITSU Sci. Tech. J., Vol. 53, No. 2 (February 2017)

good linearity against ammonia concentrations, suggesting that this adsorption system fits to the Langmuir model, 6) implying that fast measurement using initial response is applicable to CuBr thin-film sensor devices. The measured responses of a CuBr sensor device for acetaldehyde, ethanol, acetone and hydrogen sulfide are 0.01%, 0.06%, 0.045 and 1.8% in relative values to that for ammonia, respectively. Generally, metal-oxide semiconductor gas-sensor devises show responses for these gases around 10% of relative values to that for ammonia. In contrast, ammonia causes far stronger responses on the CuBr sensor device than hydrogen sulfide and those organic gases, by two digits and four digits, respectively. The aforementioned selectivity of the CuBr sensor device thus means that the device can measure only the ammonia concentration in human breath substantially, among many gas-phase components in the breath. Especially, this is the first case to reveal the possibility of directly measuring ammonia concentration in human breath, without being affected by chemically active hydrogen sulfide. 4. Quick and easy-to-use sensor system for breath The breath sensor system developed in this work is intended to be used easily at home or in the office in daily life, not only in medical facilities. Therefore, in order to minimize the user s burden, we established a fast measurement method by using the initial response of the gas sensor device mentioned in the previous section. The sensor unit is small and designed to be operated by a battery. Furthermore, it is equipped with a Bluetooth low energy (BLE) module to transmit the measured data to a smartphone. In the near future, smartphones will connect this breath sensor system to a medical cloud, and measurement history management and detection of abnormal values are expected to be done in the medical cloud. In order to simplify the operation, we did not use complicated operating buttons or a display device in the sensor unit. There is only a power switch on it. In the sensor chamber of the sensor unit, there is a CuBr sensor device and three metal oxide semiconductor (MOS) gas sensor devices, and sensors for temperature, humidity, and pressure. When the power switch is turned on, a microcomputer starts to transmit the resistance data of each gas sensor, and the temperature, humidity and pressure values to a smartphone every second in real time. The application software installed on the smartphone indicates instructions for the user, and receives the measured data from the sensor unit. It also does calculations and displays and stores the gas concentration data. When tapping the start button in the application software, a message appears asking the user to blow into the sensor unit. While a countdown timer of ten seconds is indicated, the user blows into the sensor unit. During this process, the microcomputer monitors each sensor value. Since variations between individuals in exhaled ammonia concentration are relatively large, we used changes in the resistance of the MOS gas sensor to check whether the user is blowing properly. The MOS gas sensor is suitable for this purpose because it has a wide sensitivity to many kinds of organic compounds contained in the breath. After checking that the user is blowing properly, the software calculates the ammonia concentration by using the difference in resistance between the CuBr gas sensor before and after blowing. The relationship between the resistance change and gas concentration was examined in the previous section. Figure 4 shows the prototype of the sensor unit and the smartphone when operated. In the application window, the gas concentration is indicated in parts-per-billion (ppb). The standard score based on the sampling measurement (to be mentioned in the Figure 4 Prototype of breath sensor system. FUJITSU Sci. Tech. J., Vol. 53, No. 2 (February 2017) 41

next section) is also indicated by color bars; therefore, the user can know his or her position among a group. All measurement data are stored in the smartphone, and the latest ten pieces of data can be recalled. In the near future, the data will be sent to a medical cloud via the Internet. 5. Sampling measurement of ammonia concentration in breath We conducted a sampling measurement of ammonia concentration in the breath of 128 employees from our laboratory (the average age of employees was 43). We obtained their consent to the measurement in advance, and their age and past illnesses were not examined because this measurement was done anonymously. Figure 5 shows the result of the measurement. The measured data have a logarithmic normal distribution with a median value of 440 ppb, and geometrical standard deviation (GSD) is proved as 2.30. Spanel et al. reported that the median value is 833 ppb, and GSD is 1.62 based on their measurement on examinees aged between 20 and 60. 7) They also reported that the concentration distribution shifts depending on the age distribution of the sampling group. Considering the difference in age distribution between Spanel s group and ours, our measurement result is coherent with Spanel s. Based on the results above, we confirmed that our sensing system works properly. 6. Conclusion In this report, we introduced a mobile breath sensor that can measure the ammonia concentration in the breath accurately. The biggest advantage of breath analysis is its ease of use, non-invasiveness and lack of accompanying pain like that related to collecting blood, though it is worth in principle comparing it with a blood examination. It becomes possible to continuously examine changes in ammonia related to lifestyle in real time because it is possible to measure ammonia quickly with a portable device. The breath sensor will be installed in a smart device and a wearable device in the future. In contrast, it is difficult to install a conventional large-scale analyzer in them. Moreover, we are aiming to develop an easy way to measure the breath also at home and roll out Frequency (person) 30 25 20 15 10 5 0 50 100 200 500 1,000 2,000 5,000 Figure 5 Distribution of measured breath ammonia concentrations. new healthcare services on the medical cloud. References Breath ammonia concentration (ppb) 1) T. L. Mathew et al.: Technologies for Clinical Diagnosis Using Expired Human breath Analysis. Diagnostics, 5, pp. 27 60, February 2015. 2) M. Bendahan et al.: Development of an Ammonia Gas Sensor. Sens. and Act. B, 95, pp. 170 176, 2003. 3) G. Peng et al.: Diagnosing Lung Cancer in Exhaled Breath using Gold Nanoparticles. Nature nanotechnology, 4, pp. 669 673, October 2009. 4) M. Bendahan et al.: Sputtered Thin Films of CuBr for Ammonia Microsensors: Morphology, Composition and Ageing. Sens. and Act. B, 84, pp. 6 11, 2002. 5) Y. Zheng et al.: NH 3 Sensing Mechanism Investigation of CuBr: Different Complex Interactions of the Cu+ Ion with NH 3 and O 2 Molecules. J. Phys. Chem. C, 115, pp. 2014 2019, 2011. 6) M. Bendahan et al.: Morphology, Electrical Conductivity, and Reactivity of Mixed Conductor CuBr Films: Development of a New Ammonia Gas Detector. J. Phys. Chem. B, 105, pp. 8327 8333, 2001. 7) P. Spanel, et al.: Acetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4-83 years. J. Breath Res. Vol. 1 (2007). Osamu Tsuboi Fujitsu Laboratories Ltd. Mr. Tsuboi is currently engaged in research on vital sensing technology. 42 FUJITSU Sci. Tech. J., Vol. 53, No. 2 (February 2017)

Satoru Momose Fujitsu Laboratories Ltd. Mr. Momose is currently engaged in research on sensing technology. Ryozo Takasu Fujitsu Laboratories Ltd. Mr. Takasu is currently engaged in research on sensing technology. FUJITSU Sci. Tech. J., Vol. 53, No. 2 (February 2017) 43