SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

Similar documents
Specification for: All Aluminum Alloy (AAAC) Type AL3 Stranded conductor For distribution overhead lines

SPECIFICATION FOR STOCKBRIDGE TYPE VIBRATION DAMPERS FOR DISTRIBUTION AND TRANSMISSION OVERHEAD LINES

Technical Specification for Live Line Tap Connectors

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

SPECIFICATION FOR LUGS WITH CONE CLAMP SLEEVE FOR ROUND COPPER BUSBAR

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Four Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

TECHNICAL SPECIFICATION FOR CLAMPS & CONNECTORS FOR 66/132/220/400 KV SUB-STATION

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

APDRP SCHEME, WESCO. Technical Specification for 33KV Air Break Switch PART 1: SCOPE AND CONDITIONS

660 Volts 630 & 800AMP

Technical Specification for Helical Fittings for Overhead Power Lines

Technical Specification for Galvanised Fabricated Steelwork

SPECIFICATION FOR ALL ALUMINIUM ALLOY STRANDED CONDUCTOR

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

SPECIFICATION SS-20 / 4 STEEL STRUCTURES FOR SUBSTATION AND SWITCHING STATION MATERIAL

ANNEXURE - ' D ' TECHNICAL SPECIFICATION FOR INSULATOR PINS ( PINS FOR 11,22 AND 33 kv INSULATORS )

093 : 2000 CEB STANDARD MEDIUM VOLTAGE PIN POST INSULATORS AND HARDWARE CEYLON ELECTRICITY BOARD SRI LANKA

TECHNICAL SPECIFICATION FOR CLAMPS & CONNECTORS FOR 66/132 KV SUB-STATION

SPECIFICATION FOR BIMETALLIC COMPRESSION CABLE LUGS

TECHNICAL SPECIFICATION FOR CONDUCTOR HARDWARE FITTING FOR 11/22/33 kv OVERHEAD POWER LINES

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

TRANSMISSION NEW PROJECTS DEPARTMENT TRANSMISSION LINES TOWER DESIGN AND SPECIFICATIONS SECTION ATHENS - GREECE SPECIFICATION TR-1

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Technical Specification for LV ABC Fuse Switch Disconnectors

TECHNICAL SPECIFICATION FOR CONDUCTORS

STAINLESS STEEL. Useful Information

NPS/003/033 Technical Specification for Substation Support Structures

Technical Specification for Steel Forged Fittings

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

SPECIFICATION FOR RUBBER INSULATING GLOVES FOR MEDIUM VOLTAGE CLASS 2, 3

TECHNICAL SPECIFICATION FOR CLAMPS & CONNECTORS FOR 400/220 KV SUB-STATION

Connectors. Multi-purpose connecting clamps. Stainless steel cross connectors

TURKISH ELECTRICITY DISTRIBUTION CO. TECHNICAL SPECIFICATION FOR POST (SUPPORT) INSULATORS FOR MEDIUM VOLTAGE SYSTEMS

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

Suspension clamps. Contents. General Oscillating and trunnion type suspension clamps forged.. 3. Oscillating type suspension clamps cast...

SECTION 07 TECHNICAL SPECIFICATIONS 11KV OUTDOOR TYPE SINGLE PHASE METAL OXIDE (ZNO) GAPLESS LIGHTNING ARRESTER (LA)

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME. Technical Specification (T.S)

ENGINEERING SPECIFICATION EE SPEC

SPECIFICATION FOR LOW VOLTAGE H.R.C. FUSE RAILS SIZES "00", "2", "3"

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

Technical Specification for Outdoor Porcelain Station Post Insulators

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

WARSAW ul. FILTROWA 1 phone: (48 22) , (48 22) fax: (48 22)

Bonded Seals. Description

FIJI ELECTRICITY AUTHORITY BIDDING DOCUMENT

Kind of document : Assembly manual

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

TECHNICAL SPECIFICATION FOR SUPPLY OF WEDGE CONNECTOR TO BE USED IN POWER DISTRIBUTION SYSTEM

COMPLETE REVISION September Process Industry Practices Piping. PIP PNSM0120 Purchasing Requirements for Bolting

Kind of document : Assembly manual

MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO. Ltd. (MUMBAI) SCHEDULE 'A' TECHNICAL SPECIFICATION FOR. 11 kv, 22 kv & 33 kv HORN GAP FUSES FOR

QUOTATION REQUEST (QR) Quotation Request #: SI OA BILL OF QUANTITIES & PRICING

Kind of document : Assembly manual

TECHNICAL SPECIFICATIONS

SECTION TIMBER FLOATS

TABLE OF CONTENTS INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

Tender specification KLAUS Multiparking MultiBase 2072 outdoor installation EB MultiBase 2072 outdoor installation DB

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

P.V.C. INSULATED UNARMOURED COPPER CABLES

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

TECHNICAL SPECIFICATION OF ACCESSORIES SUITABLE FOR 7/3.15 mm G.I. EARTH WIRE

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

NPS/002/001 Technical Specification for Earthing Materials

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF UNDERPASS LUMINAIRES

All definitions are defined according to ANSI/AWWA C b. Flanged Joint: The flanged and bolted joint as described in ANSI/AWWA C110/A21.10.

11KV PORCELAIN INSULATORS AND FITTINGS

Bolted Connectors & Terminals

SECTION STRUCTURAL METAL FRAMING

33-SDMS-02 SPECIFICATIONS FOR

A. American Society for Testing and Materials (ASTM):

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

All definitions are defined according to ANSI/AWWA C

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

DRAFT UGANDA STANDARD

Tender specification KLAUS Multiparking MultiBase U1 EB / MultiBase U1 DB

Maharashtra State Electricity Distribution Co. Ltd.

SPECIFICATION FOR 11 & 33kV COMPOSITE INSULATORS Part 1: Pin Type

MATERIAL SPECIFICATION FOR LUMINAIRE RAISING AND LOWERING EQUIPMENT

11-SDMS-01 REV. 03 ( )

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

Kenya Power and Lighting Company VI Contract A31

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara:

Technical Specification for. Insulators. Part 1. Insulators for High and Extra-High Voltage Overhead Lines

SECTION MISCELLANEOUS METALS

Contents EN :2008+A1:2011 (E) Page

Preassembled steel stairs with concrete-filled treads.

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 4

Transcription:

Page no. :1 of 11 SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS Prepared by: Eng. T. Lev (-חתום-) Checked by: I. Bester (-חתום (- Approved by: Eng. Y. Samoocha (-חתום (- 1

Page no. :2 of 11 Contents: No. Of Par. Page No. 1.General 3 2. Threshold conditions 3 3. Documents for The proposal 3 4. Manufacturing standards 4 5. Construction 4 6. Material 5 7. Test inspection and report 5 8. Marking 6 9. Packing 6 10. Quality assurance 6 11. Quality control 6 12. Delivery approval conditions 7 13. Summary of data 8 14. Schedule up to delivery approval 9 15. Revisions 11 Appendices: 1. Drawing no. K 2573a 2. Standard specification for quality control Q-APP-02 ed. 4 2

Page no. :3 of 11 1. GENERAL 1.1 SCOPE This specification defines the technical requirements for manufacturing, preserving, packing, furnishing and delivery to purchaser's storage of bi-metallic connectors (line taps), main: aluminium/acsr conductors, tap:copper conductors, as described in table bellow (see also drawing k2573a): IEC Cat. No Main: conductor area (mm²) Tap: conductor area (mm²) Aluminium ACSR Copper 1191980 16-70 6-50 824441 25-120 50/8 10-95 1912609 95-185 95/15-150/25 50-150 2. THRESHOLD CONDITIONS Acc. to the attached documents of the supply and storage division. 3. DOCUMENTS FOR THE PROPOSAL The bidder will submit together with his offer the following documents from the manufacturer: 3.1 Valid ISO 9001 certificate, as defined in threshold conditions. 3.2 Reference list of major customers to whom the line taps or similar have been supplied, over a period of 2 years (in the last 5 years) (including quantities and dates of supply). 3.3 Detail drawing of the proposed items and p/n (including sizes and material of the line tap and its components- bolt, nut, spring etc.). 3.4 Type test report according to the standard mentioned in par.7 for the proposed item or similar item. 3.5 In case of type test report submitted for similar item - an obligation to submit type test report for the proposed item upon award of bid. 3.6 In case of type test report submitted for similar item - "Schedule up to Delivery Approval" signed by the bidder and the manufacturer. 3.7 The manufacturer may ask and I.E.C shall consider to exempt (all the offers) from the requirement to submit type test report if the estimate value of the proposal is less then 15,000 American dollars. 3.8 Complete and filled in Summary of Data. 3

Page no. :4 of 11 Remarks: All data and descriptive material in above documents (par 3.1-3.6) shall be in English or Hebrew. "Similar means line taps in the same technology but in different dimensions. All dimensions will be in mm. Bidder which will not submit all the above will be disqualified. 4. MANUFACTURING STANDARDS The line tap shall be manufactured in accordance with the following standards: DIN 48215- Clamps for overhead power requirements. DIN 128 - Curved and wave spring lock washer. DIN 933 - M1,6 TO M52 hexagon head screws threaded up to the head. DIN 6796 - Conical spring washer for bolt/nut assemblies. DIN 934 - Hexagon nuts with metric coarse and fine pitch thread. BS EN755-2:1997: Aluminium and aluminium alloys Extruded rod/bar,tube and Profiles. BS EN 586-2:1994: Aluminium and Aluminium alloys-forging. BS EN 573-4:1995: Aluminium and aluminium alloys-chemical composition and form of wrought products.part 4 forms of products. BS EN 573-3:1995: Aluminium and aluminium alloys-chemical composition and form of wrought products.chemical composition. Other standards will be considered. 5. CONSTRUCTION 5.1 The line taps shall be designed for connecting between stranded aluminium/acsr and copper conductors. There are 4 alternatives for construction acc. to drawing k2573a. Other alternative for the construction will be considered. 5.2 The line taps shall be easy to install. The conductors shall be easy to insert (from each side) into the line tap grooves, without the need to remove the line tap parts. 4

Page no. :5 of 11 6. MATERIAL 6.1 Line tap body: corrosion resistant, high strength aluminium alloy EN AW-6082 (EN AW-Al Si1MgMn) with compressed bimetallic Al-Cu sheet. Other material indicated in DIN 48215 (list of materials acc. to par. 1.1.2 in the standard) will be considered by I.E.C. After compression the surface around the bimetallic sheet will be painted by protecting epoxy paint. The line tap body will be free from porosity and imperfections. The interior surface will be smooth and free from sharp burrs or edges which could damage the conductor. The exterior surface will be smooth. The nuts will be pressed into the lower part of the line tap s body 6.2 Bolts: steel, ISO property class 8.8, hot dip galvanized. Minimum coating thickness 40µm. The bolts will be supplied and provided with a thin film of oil. 6.3 Nuts: steel, hot dip galvanized. Minimum coating thickness 40µm. 6.4 Spring washer: hot dip galvanized spring steel. Minimum coating thickness 40µm (Type A acc. to DIN128). Alternatives should be approved by I.E.C. 6.5 Pressure pad: corrosion resistant, aluminium. The thickness of the pad will be such so it will not be twisted after tightening the bolts. 6.6 Conical spring washers: acc. to DIN 6796. Other alternative for coating of the bolt, nut and washer will be considered 7. TEST INSPECTION AND REPORT Tests will be made in accordance with the standard IEC 61284 (2nd-edition 1997). acc. to the list: type test: - Visual examination (which includes marking inspection) - Dimensions and material. - Mechanical test - Heat cycle test class B (including short circuit test. The line tap shall withstand 6.85 ka/1sec for 24kV). sample test: - Visual examination (which includes marking inspection) - Dimensions and material. - Hot dip galvanizing. 5

Page no. :6 of 11 8. MARKING Each line tap will be embossed marked with: - Trade mark of the manufacturer. - Nominal conductor diameters. - Tightening torque. 9. PACKING The line tap will be supplied in carton boxes, properly packed and lagged to prevent the line taps from possible damage during shipment, storage and delivery to the working zone. The quantity packed in each box: 824441-50 pcs. 1191980-50 pcs. 1912609-20 pcs. Each packing will be marked with the following information: - manufacturer s name and address - p/n - order number - quantity packed in the box - weight of the packing box - complete destination marking - I.E.C catalogue number 10. QUALITY ASSURANCE Manufacturer Quality Assurance Program shall meet the requirements as described in ISO 9001. 11. QUALITY CONTROL Quality control requirements will be according to I.E.C standard Q-APP-02 ed 4. 6

Page no. :7 of 11 12. DELIVERY APPROVAL CONDITIONS The successful bidder (henceforth refer to as "the contractor") shall submit: 12.1 Contractor that submitted type test for the proposed item shall submit sample test before each delivery. 12.2 Contractor that submitted type test for similar item shall submit: 12.2.1 All the required documents for I.E.C approval within the period time as indicated in par. 14 " SCHEDULE UP TO DELIVERY APPROVAL" 12.2.2 Sample test before each delivery In order to perform the tests the bidder can receive the required conductor from I.E.C Warehouse. If the supplier fails to stand in the above requirements, in accordance with the terms of the tender documents and/or the order/contract within the periods above, it shall constitute a substantial breach, entitling the I.E.C to be paid liquidated damages according to Tender document, and to pursue all other remedies available under the law for a substantial breach of contract. 12.3 Acceptance test: The I.E.C reserves the right to verify the compliance of the delivered items with this specification. Deliveries which will not pass acceptance test will be rejected 7

Page no. :8 of 11 13. SUMMARY OF DATA FOR LINE TAPS BETWEEN ALUMINIUM/ACSR AND COPPER CONDUCTORS. Name of Bidder E-mail of Bidder Manufacturer's name: -"- Fax: -"- e-mail: -"- Tel.: (Insert all data in this column) 1. IEC cat. number 824441 1191980 1912609 2. Manufacturer part number 3. Please state the manufacturing standard of the line taps. 4. Is drawing of the proposed item attached? 5. Material 5.1 Line taps body material 5.2 Bolts material. 5.3 Spring washers material. 5.4 Pressure pad material. 5.5 Conical washer material 6. Are type test reports attached? (Yes/No ) 7. In case of similar item test reports, is obligation acc. to par 3.4 (in writing) attached? (Yes/No ) 8. Tests Which standard test do the line taps comply with? 9. Packing and shipping data 8.1. Quantity packed in box ( pcs ). 8.2. Weight of box ( kg ) 8.3. Package volume of box ( m3 ) 10. Are markings in accordance with this specification? (Yes/No ) 11. Are ISO 9001 certificates attached? (Yes/No ) 12. Experience in manufacturing the proposed item ( years ) 13. Are reference list attached? (Yes/No ) 8

Page no. :9 of 11 14. SCHEDULE UP TO DELIVERY APPROVAL 14.1 Starting point is the date on which a binding contractual obligation has been created, as specified in the invitation to submit proposal. 14.2 One month before performance of the tests the contractor shall submit the final test schedule. 14.3 The period of time for the delivery approval from the starting point as indicated above will not take more than 4 months. See table on the next page: 9

Page no. :10 of 11 Name: Signature: Date: No. STAGE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Submitting of: 1 1. Datail drawing of the proposed item. 2. Test plan: - The name of the performing laboratory and address (country, city, etc.) - A list of tests, including detail procedure of each test (which will include acceptance criteria) - Schedule of the type test Week 2 Israel Electric Corp. approval of above documents after clarifications 3 Submission of one(1) sample of the proposed item 4 Israel Electric Corp. response to the submitted sample 5 Execution and submission of the type test report for the proposed item 6 Israel Electric Corp. response to the above documents 10

Page no. :11 of 11 15. REVISIONS: 1. Item 1912609 added. Catalogue numbers changed to RAM 2. 2. Quality Control changed to 02-1G. 3. Quality Control changed to ISO 9002 and change in para. 2, 4, 8, 9. 4. Change in paragraph 3.3 5. Change in par. 3,12. add para.5. 6. Change in par. 3,5 7. Changing in par. 3,4,5,6,12. 8. Chang. In drawing k2573a, quality control to Q-APP-02 and para.12 tender document instead of Annex. A. 9. Add req. for ISO, change in par. 10,12. 10. Change in par 2,3,6,7 11. Change in par 3,5,6,10,12,13 12. Change in par. 1,3,5,11, change ISO to 9001, add schedule to delivery approval. 11