Buckling Analysis of Cold Formed Steel for Beams

Similar documents
Longwave Buckling of Cold-formed Steel Studs Using Direct Strength

Direct Strength Design of Cold-formed C-sections in Combined Bending and Shear

Section Moment Capacity Tests of Rivet-Fastened Rectangular Hollow Flange Channel Beams

BEAMS, PURLINS AND BRACING. 5.1 General The design of beams for strength is usually governed by one of the following limit states:

Experimental Study on Welded Connections for Rectangular Hollow Cold Formed Light Gauge Tension Members Ravindra B. Kulkarni 1 Akhilesh Goje 2

Experiment on Precast Solid Concrete Floor Slabs resting on Cold- Formed Steel Framing Stud Walls

S T R U C T U R. magazine. Direct Strength Method for Cold-Formed Steel. Copyright. What are the Advantages in Using Direct Strength Method?

Structural Engineering and Materials

On the Direct Strength Design of Continuous Cold-formed Steel Beams

International Journal of Engineering Trends and Technology (IJETT) Volume 39 Number 2- September 2016

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

Experimental Study on Load Carrying Capacity of Cold Formed Steel Built-up Column

Local and Distortional Buckling of Cold-Formed Steel Members

DISTORTIONAL BUCKLING BEHAVIOUR OF FIRE EXPOSED COLD-FORMED STEEL COLUMNS

Theoretical and Numerical Investigation of Cold Formed I Section Castellated Beam with Hexagonal Openings

New approach to improving distortional strength of intermediate length thin-walled open section columns

Direct Strength Method for Web Crippling of Cold- Formed Steel C and Z Sections subjected to Interior One Flange Loading and End One Flange Loading

Effective Width Method Based Design for Distortional Buckling

STUDY ON FLEXURAL BEHAVIOR OF COLD FORMED C-SECTION PURLIN WITH DIFFERENT OPENING SHAPES

AISI S E1 AISI STANDARD. Errata to North American Specification. for the Design of Cold-Formed. Steel Structural Members.

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Distortional elastic buckling for aluminium: Available prediction models versus design specifications

EXPERIMENTAL AND ANALYTICAL STUDIES OF THE BEHAVIOR OF COLD-FORMED STEEL ROOF TRUSS ELEMENTS

Behaviour of Cold-Formed Steel Built-up I Section Under Bending

Local and Distortional Buckling of Cold-formed Steel Studs

Acknowledgments. Specification complication. Cold-Formed Steel Design by the Direct Strength Method

Investigation of Slenderness Ratio for Cold-Formed C-Section


CTLGroup Report No A

Development of a Cold Formed Steel Housing System

STUDY ON THE EFFECT OF SPACERS ON THE ULTIMATE CAPACITY OF INTERMEDIATE LENGTH THIN WALLED SECTION UNDER COMPRESSION *

Structural Performance of Bolted Moment Connections among Single Cold-Formed Channel Sections

Design of Beam-Columns

Direct Strength Method for the Design of Purlins

FLEXURAL BEHAVIOUR OF COLD FORM STEEL SECTIONS SUBJECTED TO STATIC LOADING

Study of Darwin guidelines for non-compact and slender steel girders with web openings

BUCKLING, POST-BUCKLING, COLLAPSE AND DESIGN OF TWO-SPAN COLD-FORMED STEEL BEAMS

Finite Element Analysis of Floor Deck Using Cold Formed Steel

Sheathing Braced Design of Wall Studs

Strength Study on Castellated Beam

TABULATED LOCAL AND DISTORTIONAL ELASTIC BUCKLING SOLUTIONS FOR STANDARD SHAPES

The University of Sydney School of Civil Engineering Centre for Advanced Structural Engineering NSW 2006 Australia. SupaPurlin

Structural Steel and Timber Design SAB3233. Topic 8 Columns Design. Prof Dr Shahrin Mohammad

E-Beam HD. Cold-Formed Insulated Composite Structural Elements. Engineering/Analysis Report

Direct Strength Design of Cold-formed C-sections for Shear

NODIA AND COMPANY. GATE SOLVED PAPER Civil Engineering Design of Steel Structure. Copyright By NODIA & COMPANY

Buckling Analysis of Cold Formed Steel Compression Members at Elevated Temperatures

CTLGroup Report No

Experimental Study on Flexural Behaviour of Cold formed Hollow Flanged Z Sections

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

CIVL473 Fundamentals of Steel Design

FLEXURAL BEHAVIOUR OF STIFFENED MODIFIED COLD-FORMED STEEL SECTIONS EXPERIMENTAL STUDY

FE modeling of elastic buckling of stud walls

JUNE 2003 REVISION. Submitted to: The American Iron and Steel Institute (AISI) Principal Investigator: Ben Schafer Assistant Professor

Universal Beam and Universal Column sections subject to pure bending are all Class 3 semi-compact or better.

BRACING REQUIREMENTS FOR LATERAL STABILITY

Research Article Numerical Analysis of Eccentrically Loaded Cold-Formed Plain Channel Columns

COLUMNS. Classification of columns:

Code No: R Set No. 1

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Experimental Study on Post Buckling Behaviour of Steel Plate Girder

ADVANCES in NATURAL and APPLIED SCIENCES

Lightweight Steel Framing. DeltaStud Load Tables

Thin-Walled Structures

A SEMI-RIGOROUS APPROACH FOR INTERACTION BETWEEN LOCAL AND GLOBAL BUCKLING IN STEEL STRUCTURES

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

Optimum Design of Cold-formed Steel Z-shape Purlins Using a Genetic Algorithm

Simple Complex Simple Complex

Marian A. GIZEJOWSKI Leslaw KWASNIEWSKI Wael SALAH

Performance Based Design of Cold-formed Steel Frames

Design of Perforated Industrial Storage Rack Columns for Distortional Buckling

research report Flexural Behavior and Strength of Cold-Formed Steel L-Headers RESEARCH REPORT RP08-3 American Iron and Steel Institute

The 2008 AISI Cold-formed Steel Design Manual

Testing and Evaluation of CFS L-headers

STRUCTURAL BEHAVIOUR OF HOLLOW STEEL SECTIONS UNDER COMBINED AXIAL COMPRESSION AND BENDING

STRUCTURAL ANALYSIS AND DESIGN OF COLD FORMED STEEL SIGMA PURLINS QIANG LIU

DISTORTIONAL BUCKLING OF C AND Z MEMBERS IN BENDING

Flexure and Serviceability Limit State

MECHANICAL BRIDGING AND BRIDGING ANCHORAGE OF LOAD BEARING COLD-FORMED STEEL STUDS. Paul E. Lackey, EIT Nabil A. Rahman, Ph.D.

Angle Cleat Base Connections

5.2 Design Section Moment and Web Capacities

Direct Strength Design for Cold-Formed Steel Members with Perforations. We look forward to your comments regarding this ongoing research.

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

midas Gen MIDAS On-Demand Service midas Gen Advanced Webinar Steel Structure Design

Torsion in thin-walled cold-formed steel beams

Design of Laterally Unrestrained Beams

Shear tests of hollow flange channel beams with stiffened web openings

Study on the Capacity of Cold-formes Steel Built-up Battened Colums Under Axial Compression

This is a repository copy of Cross-sectional optimization of cold-formed steel channels to Eurocode 3.

Question Paper Code : 11410

Experimental Investigation of Cold-formed Steel Beam-column Sub-frames: Pilot Study

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

On Design of Profiled Sheets with Varying Cross Sections

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

I. INTRODUCTION. International Journal of Engineering Innovation & Research Volume 4, Issue 4, ISSN:

Product Designation As specified in the AISI standard for cold formed steel framing General provisions A5.2.

AN EXPERIMENTAL STUDY ON FRP STRENGTHENED COLD FORMED STEEL BUILT-UP CHANNEL SECTION

Analysis and Design of Steel

Single & Back-to-Back StiffWall Column Product Profile

DESIGN AND ANALYSIS OF PRE ENGINEER FRAME WITH IS800:2007

Transcription:

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 1 Buckling Analysis of Cold Formed Steel for Beams Prakash M. Mohite *, Aakash C. Karoo ** * Associate Professor, Department of Civil Engineering, Rajarambapu Institute of Technology, Islampur, India ** PG Scholar, Department of Civil Engineering, Rajarambapu Institute of Technology, Islampur, India Abstract- Cold formed steel are nowadays used for building construction especially non-load bearing partition, curved walls, etc due to its flexural strength and good appearance. The cold formed steel enhances the mean yield stess by 15% to 30% as compared to hot rolled steel. In this paper detailed parametric and comparative study of cold formed steel sections by different codes is carried out for prediction of flexural strength of beams. Various codes predict different strength. The flexural strength of cold formed steel beam is carried out and presented using CUFSM software which uses Direct Strength Method for prediction of flexural strength and this flexural strength is compared with IS 801-1975 and experimental results. Index Terms- Cold formed steel, flexural strength, Direct Strength Method I. INTRODUCTION Cold formed steel are also called light gauge steel and are cold formed from steel or strips. Cold-formed sections are produced by bending and shaping flat sheet steel at ambient temperatures. The thickness of steel sheet used in cold formed construction is usually 1 to 3 mm. Much thicker material up to 8 mm can be formed if pre-galvanized material is not required for the particular application. Normally, the yield strength of steel sheets used in cold-formed sections is at least 280 N/mm 2, although there is a trend to use steels of higher strengths, and sometimes as low as 230 N/mm 2. For the determination of member elastic buckling load/moment, CUFSM software (Schafer 2006; Schafer and Ádány 2006) is mainly used which uses finite strip method for calculation and it gives nearer to experimental results as compared to other methods. However, currently, FSA can only handle accurately single-span members (mostly simply supported) subjected to uniform internal force and moment diagrams. Conventional Finite Strip Method (FSM) provides a means to examine all the possible instabilities in a coldformed steel member under longitudinal stresses (axial, bending, or combinations thereof). Various types of buckling may occur such as local buckling, distortional buckling, flexural-torsional buckling, lateral -torsional buckling as shown in Figure 1. In Figure 1, the first minimum (Point 1) is a local buckling mode, which involves buckling of the web, compression flange, and lip stiffener. The second minimum (Point 2) is the flange distortional buckling mode and involves the rotation of the compression lipflange component about the web-flange junction. At longer wavelengths where the purlin is unrestrained, a flexural-torsional or lateral buckling mode occurs (Point 3). However, if the tension flange is torsionally restrained, then a lateral distortional buckling mode may take place, as shown by Point 4 (Hancock 1998). This lateral distortional buckle strength is dependent on the degree of torsional restraint provided to the tension flange (Hancock 1998). Figure 1: Buckling Modes Subject to a C-Purlin for Major Axis Bending. The objectives of this paper are as follows: II. OBJECTIVES

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 2 1. To study various modes of buckling occurring in a cold formed steel members when subjected to flexural loading. 2. To calculate finite strip solution for buckling class such as global, distortional or local buckling using CUFSM software. 3. Hence, after calculating the values for loading by using CUFSM software, obtaining the values of flexural strength by Direct Strength Method. 4. To study, design and compare the values of flexural strength by Direct Strength Method as well as by Indian Standard (IS 801-1975) code and by experimental value.. III. DESIGN FOR FLEXURAL STRENGTH OF BEAM Review of Codal Provisions: The following codes of practices are studied to know how these limit states are handled : 1) Direct Strength method. 2) IS Code 801-1975 of practice for use of cold formed light guage steel structural members in general building construction. Different countries use different design methods for the light gauge cold formed steel structures. India uses IS: 801-1975 which is based on allowable/working stress method of design. Considering an example of a C-lipped section of 21.71446 cm X 6.2966 cm X 0.18034 cm with yield stress of 404.7222 N/mm 2 A. Computation as per IS code 801-1975 of practice for use of Cold formed light guage steel structural members in general building construction: Material Properties : yield stress fy 404.7222 N/mm 2 i. Computation of Sectional Properties: Depth d 217.1446 mm Width w 62.966 mm Depth of lip D 24.4942 mm Thickness t 1.8034 mm Area A 708.64 mm 2 Span of length L 1000 mm Centroid: CG of section : Xcg 18.083 mm Zcg 108.572 mm Moment of inertia : Ixx 5.0513 X 10 6 mm 4 Izz 0.4250 X 10 6 mm 4 ii. iii. Computation of effective width: Checking of above section as per clause 5.2.2.1 IS 801-1975 (Page No: 6): Effective width calculation of compression elements : w Flange is fully effective if t (w) lim t Hence w 6.2966 34.9151 t 0.18034 ( w 1435 ) lim 1435 71.330 t fy 404.7222 Hence w t < (w t ) lim. Therefore Entire area is effective. Determination of safe load: Section modulus Se Ixx Zcg 5.0513 X 106 108.572 46525.7 mm 3 Allowable resisting moment Se X fy 46525.7 X 404.7222 M 18.8 x 10 6 Nmm Let w be the load in N/mm Figure 2: C lipped section

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 3 w X 1000 2 8 w 150.4 N/mm 18.8 X 10 6 iv. Check for web shear : Maximum Shear force V 150.4 X 1000 Maximum average shear stress Fmax V A h 217.1446 120.4084 4590 fy 4590 404.7222 228.1571 2 75.2 X 10 3 N 75.2 X 103 708.64 As per clause 6.4.1 IS 801-1975 (Page No: 15) : Since h t < 4590 fy Therefore the gross area of a flat web Fv 1275 fy h t Fv 213.025N/mm 2 Fv must not be greater than Fv max 0.4fy 0.4 X 404.7222 Fv max 161.88 N/mm 2 Hence Fv Fv max 161.88 N/mm 2. 106.118 N/mm 2 1275 404.7222 120.4084 Thus, Fv Fv max 161.88 N/mm 2 this is greater than the maximum Average shear stress of Fmax 106.118 N/mm 2. Thus the beam is therefore safe in shear. v. Check for bending compression in web : As per clause 6.4.2 IS 801-1975 (Page No: 16) : Actual compression stress at junction of flange and web : f bw f c X 62.966 1.8034 62.966 0.4 X fy X 62.966 1.8034 62.966 235.878 N/mm 2 Permissible: F bw 36560000 ( h t )2 kg/cm 2 3585311.24 ( h t )2 N/mm 2 247.29 N/mm 2 Since F bw > f bw. Hence Safe in bending. vi. Combined Bending and Shear Stresses in Webs : As per clause 6.4.2.3 IS 801-1975 (Page No: 16) : ( fbw Fbw )2 + ( Fmax Fv )2 1 where, f bw actual compression stress at junction of flange and web; F bw 3585311.24 ( h t )2 N/mm 2 Fmax actual average shear stress, that is, shear force per web divided bv webs area; Fv allowable shear stress, except that the limit of 0.4fy, shall not apply. ( 235.875 247.29 )2 + ( 106.118 213.025 )2 0.9934 Since Combined Bending and Shear Stresses in Webs is less than unity. Hence the section is safe. vii. Determination of deflection : Deflection δ 5wL4 < L 384EI 325

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 4 where w 150.4 kn/m 150.4 N/mm L 1000 mm E 2.033 X 10 5 N/mm 2 Ixx 505.1343 X 10 4 mm 4 Hence δ 5 X 150.4 X (10 3 ) 4 384 X 2.033 X 10 5 X 505.1343 X 10 Permissible : L 1000 3.076 mm. 325 325 Hence safe. 4 1.9096 mm. B. Computation as per Direct Strength method (DSM) : i. Check for Section as per AISI-S100-07: Material properties is same as in IS 801-1975 calculations. The following Checks must be satisfied for the C section as per AISI-S100-07 Section 1.1.1.2 : ho 120.5755 < 321. OK. 217.446 bo 62.966 D 24.4942 ho 217.1446 bo 62.966 D 24.4942 bo 62.966 E fy 34.9151 < 75. OK. 13.5822 < 34. OK. 3.4486 > 1.5 and < 17 OK. 0.3890 < 0.70 OK. 2.033 X 105 404.7222 502.3198 > 421 OK. Figure 3: C lipped section notations ii. Calculation of Yield moment and Critical Elastic Buckling Moment: From CUFSM software assigning the value for fy 404.7222 N/mm 2,we get, Yield Moment My 18.82987 X 10 6 Nmm. From Figure 4 we obtain the load factors as: Local Buckling Mcrl My 0.98606 Distortional Buckling Mcrd My 1.1922 Global Buckling Mcre My 0.71685 Figure 4: Graph of load factor vs length. Hence Critical Elastic Local Buckling Moment Mcrl 0.98606 X My

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 5 0.98606 X 18.82987 X 10 6 18.56738 X 10 6 Nmm. Critical Elastic Distortional Buckling Moment Mcrd 1.1922 X My 1.1922 X 18.82987 X 10 6 22.44897 X 10 6 Nmm. Critical Elastic lateral torsional Buckling Moment Mcre 0.71685 X My 0.71685 X 18.82987 X 10 6 13.49819 X 10 6 Nmm. iii. Calculation of Nominal Flexural Strength : As per AISI-S100-07 Section 1.2.2 Nominal Flexural Strength of beam is minimum of local, distortional and lateral torsional buckling and is calculated as follows: a. Nominal flexural strength for Lateral-torsional buckling per AISI-S100-07 Section 1.2.2.1 : 1.2.2.1 Lateral-Torsional Buckling The nominal flexural strength, Mne, for lateral-torsional buckling shall be calculated in accordance with the following: The nominal flexural strength, M ne, for lateral-torsional buckling is for M cre < 0.56M y M ne M cre (Eq. 1.2.2-1) for 2.78M y > M cre > 0.56M y 10 10M y M ne M y 1 (Eq. 1.2.2-2) 9 36M cre for M cre > 2.78M y M ne M y (Eq. 1.2.2-3) where where, Mcre Critical elastic lateral torsional buckling moment. My Yield the Moment. extreme fiber in first yield Here equation M cre 1.2.2-2 Critical elastic satisfies lateral-torsional the following buckling condition: moment determined 2.78My > in Mcre accordance > 0.56My with Section 1.1.2 2.78 X 18.82987 X 10 6 > 13.49819 X 10 6 > 0.56 X 18.82987 X 10 6 52.347 X 10 6 > 13.49819 X 10 6 > 10.544 X 10 6 Hence, Mne 10 10My My (1 ) 9 36Mcre Mne 10 X 18.82987 X 9 106 10 X 18.82987 X 106 (1 36 X 13.49819 X 10 6) Mne 12.81482 X 10 6 Nmm Hence Nominal flexural strength for Lateral-torsional buckling is: M y S f F y, where S f is the gross section mod ulus referenced to (Eq. 1.2.2-4) Mne 12.81482 X 10 6 Nmm b. Nominal flexural strength for Local buckling as per AISI-S100-07 Section 1.2.2.2 : The 1.2.2.2 nominal Local flexural Buckling strength, Mnl, for local buckling shall be calculated in accordance with the following: Mcre The Critical nominal elastic flexural local strength, buckling M n, moment. for local buckling is for 0. 776 M n M ne (Eq. 1.2.2-5) for > 0.776 0.4 0.4 M M n cr M 1 0.15 cr M ne M ne M ne My Yield accordance Moment. with Section 1.1.2 M Here equation ne is defined in Section 1.2.2.1. 1.2.2-6 satisfies the following condition: Local-global slenderness ratio l is given as: l Mne 12.81482 X 106 Mcrl 18.56738 X 106 0.83 > 0.776 Since l > 0.673, nominal flexural strength, Mnl is given by Eq. 1.2.2-6 as follow: Mnl (1 0.15 ( Mcrl Mne )0.4 ) ( Mcrl Mne )0.4 Mne (Eq. 1.2.2-6) where M ne M cr (Eq. 1.2.2-7) M cr Critical elastic local buckling moment determined in

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 6 18.56738 X 106 (1 0.15 ( 6)0.4 18.56738 X 10 ) ( 6 6)0.4 X 12.81482 X 10 6 12.81482 X 10 12.81482 X 10 Mnl 12.27769 X 10 6 Nmm (local-global interaction reduction) Hence Nominal flexural strength for local buckling is: Mnl 12.27769 X 10 6 Nmm. c. Nominal flexural strength for Distortional buckling as per AISI-S100-07 Section 1.2.2.3: The 1.2.2.3 nominal Distortional flexural strength, Buckling Mnl, for local buckling shall be calculated in accordance with the following: Mcrd Critical The nominal elastic distortional flexural strength, buckling M moment. nd, for distortional buckling is for d 0. 673 for d > 0.673 My Yield Moment accordance with Section 1.1.2. Distortional slenderness ratio d : d My Mcrd M nd M y (Eq. 1.2.2-8) 0.5 0.5 M M nd crd M 1 0.22 crd M y (Eq. 1.2.2-9) M y M y where d M y M crd (Eq. 1.2.2-10) X 106 18.82987 22.44897 X 106 0.92 > 0.673 Since d > 0.673, nominal flexural strength, Mnl is given by Eq. 1.2.2-9 as follow: Mnd (1 0.22 ( Mcrd My )0.5 ) ( Mcrd My )0.5 My 22.44897 X 106 Mnd (1 0.22 ( 6)0.5 22.44897 X 10 ) ( 6 6)0.5 X 18.82987 X 10 6 18.82987 X 10 18.82987 X 10 Mnd 15.62116 X 10 6 Nmm. Hence Nominal flexural strength for distortional buckling is: Mnd 15.62116 X 10 6 Nmm M crd Critical elastic distortional buckling moment determined in M y is given in Eq. 1.2.2-4. iv. Nominal flexural strength of the beam as per AISI-S100-07 Section 1.2.2: Nominal flexural strength of the beam is minimum of Mne, Mnl, Mnd. Hence Mn 12.27769 X 10 6 Nmm 12.27769 knm. For beams meeting geometric and material criteria of section and shall be as follow: 1.67, 0.9 Hence, design strength Mn 11.04992 knm. Allowable design strength Mn/ 7.351911 knm. IV. RESULTS As per IS 801-1975 Flexural strength of beam 18.8 knm. As per Direct Strength Method Flexural strength of beam 11.04992 knm. Experimental value of flexural strength for cold formed steel beam is M 11.72445 knm. V. CONCLUSION A comparative study on the flexural strength of lipped channel sections based on different code provisions and the values are compared with respective experimental values. With the comparative study, parametric study has been conducted by varying the lip depth for selected sections through CUFSM analysis, which is the background analysis for DSM. The load factor corresponds to distortional buckling for each cross sectional shape has been calculated. IS: 801 provisions are not accounting for distortional buckling and hence it over predicts the strength. Direct strength method predicts the section strength closer to the experimental results. Load factor corresponds to distortional buckling increases up-to the ratio of lip depth to flange width and later it decreases.

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 7 VI. ACKNOWLEDGMENT I take this great opportunity to acknowledge my deep sense of gratitude towards my guide Prof P.M. Mohite for his valuable guidance without which would have been difficult to present my seminar. I also acknowledge Dr. H.S. Jadhav (HOD Civil Engineering Department) & Prof. D. B. Kulkarni (HOP Civil Structure) for providing the necessary facility to present my seminar. I am very much thankful to all my friends who have helped me to complete my seminar. At last I take this opportunity to thank all those who have directly or indirectly helped me in completion of this seminar work. REFERENCES [1] AISI Stanard, North American specification for design of steel members, July 2007. [2] B.W. Schafer and S. Adany (2006) Buckling analysis of cold-formed steel members using CUFSM, 18 th International Conference on CFS, October 26-27,2006. [3] B.W. Schafer Designing Cold-Formed Steel Using the Direct Strength Method, 18th International Specialty Conference on Cold-Formed Steel Structures October 26-27, 2006. [4] Cilmar Basaglia and Dinar Camotim Buckling, Postbuckling, Strength, and DSM Design of Cold-Formed Steel Continuous Lipped Channel Beams, Journal of structural Engineering. 2013.139: 657,668. [5] Dr. B.C. Punmia, Ashok Kumar Jain, Arun Kumar. Jain, Design of Steel Structures, Jan 1998,pp 561-600. [6] Indian Standard IS: 801-1975, Code of practice for use of cold-formed light gauge steel structural members in general building construction, Bureau of Indian Standards, New Delhi (1976). [7] L. C. M. Vieira, B. W. Schafer, Behavior and Design of Sheathed Cold-Formed Steel Stud Walls under Compression J. Struct. Eng. 2013.139:772-786. [8] R.B. Kulkarni, Shweta B.Khidrapure, Parametric study and comparison of Indian standard code with British code for the Design of Light gauge cold formed flexural members, International Journal of Engineering and Technical Research (IJETR) ISSN: 2321-0869, Volume-2, Issue-11, November 2014. [9] Somadasa Wanniarachchi, Flexural behavior and Design of Cold formed steel beams with rectangular hollow flanges, December 2006.Vijayasimhan M, Marimuthu V, Palani G.S and Rama Mohan Rao P (2013) Comparative Study on Distortional Buckling Strength of Cold-Formed Steel Lipped Channel Sections, Research Journal of Engineering Sciences,Vol 2(4), 10-15 April (2013). AUTHORS First Author Prakash M. Mohite, ME, Rajarambapu Institute of Technology, Islampur, prakash.mohite@ritindia.edu. Second Author Aakash C. Karoo, PG Scholar, Department of Civil Engineering, Rajarambapu Institute of Technology, Islampur, akaakashkaroo@gmail.com.