Pump ED 101. Pump Selection for VFD Operation Part 3 Q / H Pump Down vs Level Control. Introduction. Pump Down vs Level Control

Similar documents
An Introduction to Pressure Sewers. Copyright Submersible Wastewater Pump Association (SWPA)

Table of Contents. Foreword... xvii Executive Summary... xxi. Chapter One Pump Fundamentals, 1

Calculate the Costs of Piping System Elements

Pumping Plant Detailed Evaluation Worksheet

University Curriculum Development for Decentralized Wastewater Management

Experior as an Energy Savings Solution for Wastewater Lift Stations. Lisa Riles NA Marketing and Business Development Manager Xylem

Application Solution. Foreword. Figure 1. Affinity Laws for Centrifugal Pumps

eone engineered perfectly. to do one job Environment One Low Pressure Sewer Systems

Peerless Pump Company Handbook of Engineering Data

AALSO Summary of Formulas needed for Levels I, II and III.

Water & Wastewater Operation: Pipe Systems, System Curves, & Pump Curves

FLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.

BACKGROUND INFORMATION

Submersible Axial Flow Propeller Pumps

Variable Frequency Drives

The redesign of a more complex or non-geometrically similar designed product line does not allow resource sharing across sizes (models).

Water and wastewater treatment operations

AALSO Proficiency Program Level I, II & III

APS Pump & Blower Program.

7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS

TECHNICAL MANUAL TEH-375A. Pump & System Curve Data for Centrifugal Pump Selection and Application

Pump Performance Curves and Matching a Pump to a Piping System

Pump Performance Curves and Matching a Pump to a Piping System

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

T Series. Self-Priming Centrifugal Pumps

ARMY TM AIR FORCE AFM 88-11, Vol. 2 SANITARY AND INDUSTRIAL WASTEWATER COLLECTION-- PUMPING STATIONS AND FORCE MAINS

Pump Vibration. Related Considerations and How Much is Too Much? MWEA Collection Systems Seminar. Steve Fehniger, P.E.

Booster Pump Fundamentals. By: Bill Baglot

SUGGESTED SPECIFICATIONS Pump Frames through 64132

AR No. # Efficient Irrigation

N-pump, Standard Motor

Products II 1 VERTICAL LINE SHAFT PRODUCT AND OIL LUBRICATED PUMPS II 2 SUBMERSIBLE PUMPS II 3 MIX FLOW PRODUCT AND OIL LUBRICATED PUMPS

Effluent Conveyance. Paul Trotta, P.E., Ph.D. Justin Ramsey, P.E. Chad Cooper

PUMP SELECTION CONTROLS. Winfred RONO, June 27, 2018

Application of Variable Frequency Drives for Energy Savings

WARRENDER, LTD. Services. Ammonia & CO² Circulation and Transfer Pumps

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

Goulds API ISO / API 610 VS4 Vertical Sump Pump

VERTICAL MULTISTAGE PUMPS - MV SERIES - 60Hz

Maintenance Costs. Start With. Not when it comes to your pumps! Photo 1: Extensive damage on subject pump

Modal Analysis as a Tool to Resolve Pump Vibration Issues

VSS S U B M E R S I B L E S E W A G E P U M P S

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

Water Well Screens and Well Efficiencies Designing an Efficient Well

Supplemental Pumps Pay Off During Low River Conditions

Module 9 : Sewage And Storm water Pumping Stations. Lecture 11 : Sewage And Storm water Pumping Stations

Sump Pump Training Flyer

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

in the Midsouth Management Chris Henry, Ph.D., P.E. Assistant Professor and Water Management Engineer Merritt McDougal Graduate Research Assistant

ASRAC Pumps Working Group Scope

Presentation Outline ENERGY CONSERVATION: 10/20/2017

Appendix J Effluent Pump Station

2015 HDR, all rights reserved.

Flygt 3171, 50Hz. Technical Specification

DSC/DSCA3. EBARA Submersible Sewage Pumps Contents. Project: Model: Chk d: Date: Model

IE3? Premium Efficiency

EXPERIMENTAL AND NUMERICAL INVESTIGATION OF CENTRIFUGAL PUMP PERFORMANCE IN REVERSE MODE`

NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A

NZQA registered unit standard version 1 Page 1 of 7. Demonstrate knowledge of pumps and pump selection for rural systems

ASHRAE All about T. Either control directly with a temperature reactive VFD pump or valves and a pressure reactive pump

IRRIGATION PUMPS - PRESERVING PERFORMANCE

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

McDuff WTP High Service Pump Replacement

PV Systems IV EE 446/646

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Embedded Energy in Water Studies Study 1: Statewide and Regional Water-Energy Relationship

PRELIMINARY WASTEWATER CAPACITY STUDY

SUGGESTED SPECIFICATIONS

Eco-Flow - C VARIABLE FREQUENCY DRIVE PRODUCT BROCHURE. for Commercial Swimming Pools & Water Feature Pumps. H flow 2. Pool & Spa Products Division

Session 2 Pump Selection. Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017

Troubleshooting Piping Systems

TECHNICAL INFORMATION Bulletin

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

Coming and Going An Overview of Infrastructure Common to Water Distribution and Wastewater Collection Systems

TODAY S COUPON: 425 MGD Pump Station at 30% OFF

Pumps and Pumping Stations

SD/SW/VS50 SD50 SW50 VS50

A Case Study of Latham Water District s Mohawk View High Lift Pump Station Rehabilitation

6. PUMPS AND PUMPING SYSTEM

PUMPS & PUMPING SYSTEMS

Pumped Outlets for Drainage Systems

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Changing The Way Water Moves Ft Lauderdale, FL

C o l u m n S u m p P u m p s

Use these buttons to view the show

Reducing costs in parallel pumping

Pump System Energy Saving Practices

What is a solar water pump? 3-4. Smart Solar Water 5-6. Small Centrifugal Pump Systems 7. MPPT Diaphragm Pump Systems 8

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

Public Review Draft. BSR/ASHRAE/IES Addendum an to ANSI/ASHRAE/IES Standard

CHAPTER 8 ENERGY REQUIREMENTS AND CONSERVATION

Hydraulics Laboratory Experiment Report

Overhaul Issues on Vertical Pumps

CHAPTER 8 CAPITAL IMPROVEMENT PLAN

G2S. Vertical Sump Pump

TECHNOFORCE e-hvtm. VARIABLE SPEED BOOSTERS WITH VERTICAL MULTISTAGE e-sv PUMPS 60 HZ TECHNICAL BROCHURE D-608B

EO = IHP= The efficiency of a pumping plant is calculated as follows:

Horizontal and Vertical End Suction Pumps

Contents. What is a solar water pump? 3-4. Smart Solar Water 5-6. Small Centrifugal Pump Systems 7. MPPT Diaphragm Pump Systems 8

Transcription:

Pump Selection for VFD Operation Part 3 Q / H Pump Down vs Level Control Joe Evans, Ph.D joeeevans@gmail.com Pump ED 101 http://www.pumped101.com Introduction In Part 2 we took a look at the pump selection process for VFD operation in closed and open loop circulation applications. In those applications pressure declines as flow is reduced. In this section we will review a different type of variable flow application - pump down - one where pressure increases even if flow, or the flow requirement decreases. Here, we will take a close look at pump down applications and show how they can often benefit from conversion to level control. Constant pressure (with the exception of certain industrial applications) is a relative new comer to variable speed operation but, pump down applications have used variable speed drivers for decades. A major reason that these applications took advantage of this technology early on, was simple. Large motors, used on pumps in sewage (and other) lift applications, were often limited to two or three starts per hour even if current limiting, starting techniques were employed. By varying the speed of these large pumps the wet well could be maintained at or near some predetermined level and thus frequent starting became a non-issue. Before the advent of the VFD, speed control was costly and difficult. Today it is relatively simple and, although there other cost benefits, power savings alone can often justify level control operation in many installations. Pump Down vs Level Control Pump Down Although there are many pump down applications, municipal waste water is one of the most common. Typical installations include treatment plants and gravity line lift stations. Waste water pumping stations usually incorporate several pumps with different capacities that can be sequenced to meet changing demand. Although pump size varies by installation, some of the smaller ones are often 50-100 hp and the larger ones can be 1000 hp or more.

These stations consist of two basic designs -- wet pit and dry pit. A wet pit station consists of a single collection well with submersible or vertical column pumps installed directly in the well. Some, relatively shallow wells, may utilize self or assisted priming pumps. The dry pit design consists of a wet collection well that is bottom piped to a nearby dry pit that contains shaft driven or close coupled pumps. The purpose of the two pit design is to allow use of standard, solids handling centrifugals and still take advantage of the elevation of the waste water in the collection basin. Like some submersible pumps, dry pit pumps are often designed to utilize the additional NPSHA in order to provide a higher efficiency at BEP than might otherwise be obtainable. Figure 1 compares the two designs. Please note that the capacities of the wet wells seen in the illustrations can vary from a few thousand to tens of thousands of gallons. Figure 1 Even though the two designs are quite different, they operate in much the same manner. Under normal pump down operation, both begin pumping at some maximum level and stop at some minimum level. These levels may be further defined as staged levels. For example, two or three pumps may be activated when the well approaches its maximum level, one or two may be required at some intermediate level, and only one may remain on when the level is near its minimum. The staging scheme varies by application, pump size, and the number installed. Both wet and dry pit designs will employ a minimum of two pumps, even though each is capable of handling maximum design flow. As you might expect, back up is quite important in waste water applications (especially if a fan is mounted in the upper portion of the wet well).

Consider the example shown in Figure 2. Here we see a wet pit with a maximum liquid level that is 20 above the suction of the pump. The minimum level is 6 above the suction of the pump. The distance from the pump s suction to grade is 35. Ignoring friction, the TDH required to move the waste water from the pump s suction to grade varies from 15 at the maximum liquid level to 29 at the minimum level. If we assume a constant flow of 3750 gpm and a hydraulic efficiency of 78%, what is the BHP required at the maximum and minimum levels? Grade Incoming Line Maximum Level 20' 35' Minimum Level Pump Suction 6' Figure 2 Using the BHP equation - BHP = (GPM x Head) / (3960 x Pump Efficiency) we will calculate 18.21 BHP at the maximum level and 35.2 BHP at the minimum level. If we further assume that there is no additional flow into the wet well once the pump down operation begins, the average power required to bring the level from maximum to minimum is 26.7 BHP. Although this example utilizes an ideal pump (flow and efficiency remain constant during pump down), it illustrates the power range required by a pump down application due to decreasing wet well level and the corresponding increase in TDH that the pump must provide.

Head in feet This example also suggests that minimizing wet well drawdown could result in a significant savings in power. Unfortunately, in many pump down applications, it is difficult to further minimize drawdown because the volume of the wet well is designed to accommodate varying incoming flows, minimum run time, and pump staging. Open trench type designs can minimize drawdown (due to a high surface area to depth ratio) but are usually limited to treatment sites. All that can be done with standard wells is to select the most efficient combination of pump sizes that will meet demand under varying conditions. Constant speed operation lends itself well to pump down applications as long as the wet well is properly designed and the pumps are properly sized. The reason is that higher flows are usually required at or near the maximum wet well level while lower flows are acceptable at or near the minimum level. This can allow the system curve to follow that of a standard centrifugal pump curve. Unfortunately variable speed, pump down operation is usually difficult. In these applications, the head required increases as flow decreases -- just the opposite of constant pressure or circulation applications. Although not impossible, it is usually difficult to find a single pump with enough head rise from maximum to minimum flow to accommodate the necessary speed changes. Figure 3 shows a pump sized for constant speed use in the pump down example seen in Figure 2. Figure 3 Pump Down Constant Speed 40 35 36 750 GPM 40% 14.2 HP 30 25 30 26 2250 GPM 73% 17.9 HP 23 20 20 3750 GPM 78% 18.2 HP 60hz 15 15 10 10 5 5 0 0 750 1500 2250 3000 3750 4500 5250 6000 Gallons Per Minute

The curve shown is that of a 12, 20 HP submersible sewage pump running at 870 RPM. As you can see, it requires 18.2 HP at the beginning of the pump down cycle and 14.2 HP as it approaches the end of the cycle. Normally two of these pumps would be installed and alternated at the beginning of each cycle. (Although it would increase the first cost, a more efficient installation might incorporate three pumps with a BEP capacity of approximately half of the one seen in Figure 3. Depending upon incoming flow, one or two pumps would start at the beginning of the cycle while only one would remain on line during the last portion of the cycle.) Level Control Level control takes a very different approach to removal of wastewater from the collection well. Rather than pumping the well down and then allowing it to refill, some predetermined level is maintained while accommodating the varying, incoming flow. In doing so, the NPSHA remains nearly constant and thus reduces the power required as incoming flow diminishes. Level control can be accomplished via the sequencing or staging of several smaller, constant speed pumps or by varying the speed of a larger one. Although staging can be effective in some installations, it becomes more difficult with larger pumps due to the multiple starts and stops that they must endure. Long before the VFD became an acceptable alternative, level control was accomplished with the help of a device known as the liquid rheostat. This device varied the resistance of the rotor of a wound rotor, AC motor and thus the slippage it exhibited during rotation. For example, if the rotor windings are shorted (i.e. no resistance in the rotor circuit), its performance is similar to that of a squirrel-cage motor. When a resistance is inserted into the rotor circuit, rotor current is reduced and a proportional decrease also occurs in the stator. The liquid rheostat varied resistance by raising and lowering electrodes into a tank containing an electrolyte solution. At any point in time, the degree of submersion in the electrolyte was proportional to the resistance of the rotor circuit. The control circuit used a bubbler system that translated wet well level into pressure. The result was a variable speed pump that could maintain a reasonably precise level while running continuously. Despite it s Rube Goldberg appearance, the liquid rheostat was popular in waste water installations well into the 1990 s and is still used today in other wound rotor motor applications. Figure 4 shows the same 20 HP sewage pump operating under VFD control. Rather than pumping the wet well from maximum to minimum, the VFD is receives feed back from a submersible pressure transducer and varies pump speed to maintain the liquid level at or near the maximum seen in Figure 2. The maximum head

Head in feet required, regardless of the flow rate, is approximately 15. As you can see, this results in a significant power savings during periods of reduced flow. Again, please note that this is a simple example and the system curve may not be a straight line but may rise due to friction at higher flows. Level Control VFD Operation 40 35 750 GPM 45% 6.3 HP 30 25 2250 GPM 75 % 11.4 HP 60hz 55hz 20 3750 GPM 78% 18.2HP 50hz 45hz 15 40hz 10 System 5 0 0 750 1500 2250 3000 3750 4500 5250 6000 Gallons Per Minute Figure 4 Although this power reduction is pretty apparent, there is a more dramatic method of demonstrating its magnitude. If we convert the HP required at each of the three flow points to HP/Gal pumped we would see the following for the pump down application shown in Figure 3. At the beginning of the cycle HP/Gal is 0.0048. At the halfway point it increases to 0.0079 - - an increase of 65%. And, as it approaches shut off, HP/Gal increases to 0.0189 - - almost four times the amount required at the beginning of the cycle! Lets use the same method to evaluate the level control application shown in Figure 4. At full speed (60hz) HP/Gal is the same as in the example above - - 0.0048. But the halfway point flow (50hz) it increases to just 0.005 - - an increase of 5%. At minimum flow (about 43hz) it increases to 0.008. Although this represents an increase of 75% it is far, far less than the 4X increase seen in the pump down example.

Pump selection in level control installations is similar to that of other variable flow applications. A major difference is that, depending upon the design, multiple pumps may be operating at the same time and more than one may be under VFD control. But, regardless of the design, the pump(s) must be able to meet the maximum design flow and TDH at synchronous speed. Head rise to minimum flow should be great enough to allow a meaningful power reduction. In my opinion, a minimum operating range of 13 hz or 60% head rise to minimum flow is a reasonable goal. And, as with other variable speed applications, the pump s BEP should be selected to accommodate the range of flows required. It is for this reason that often, two smaller pumps, rather than a single larger one, will be installed and controlled by a single VFD. Joe Evans September 2004 (Updated June 2006)