PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

Similar documents
Over pressure Switching pressure difference (typical) Lower range Upper range

ACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4

VSM/55600/N2, Hollow piston rod cylinder Magnetic piston, double acting

VMiniature Basic Switch

F64G - Olympian Plus Plug-In System General purpose filter

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

min. 50min. 65min. PIT / P3 / P4 Ø

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

M/44000/M LINTRA rodless cylinders Double acting, magnetic piston

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

SITRANS P measuring instruments for pressure

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

Pressure transducers DMU 02 Vario (flush)

RA/28000;.../M, RA/28300;.../M Pneumatic cylinder, ISO Non-magnetic & magnetic piston, single acting Ø mm

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

Field case for temperature transmitter Model TIF11

Type Type 2000 Transducers. I/P & E/P Transducers

Flow Rate Transmitters/ Flow Switches

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

HS-429 Vibration Trip Manual

CombiTemp TCR6 Standard RTD temperature sensor

Diaphragm pressure gauge

Diaphragm seal with threaded connection Threaded design Model

LSA 53.2 Low Voltage Alternator - 4 pole

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

Solenoid valve 2/2 way N.O. With pilot control

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

Low Voltage Alternators - 4 pole LSA 46.2

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

Liquid level switch BW 17

QGO Oxygen Sensor. Building Technologies HVAC Products

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

M7100 Pressure Transducer

LSA 47.2 Low Voltage Alternators - 4 pole

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

Flow measurement of Liquids and Gases

LSA 42.3 Low Voltage Alternators - 4 pole

Suction Filter - SE. Working Temperature From -25 to +110 C. Materials. Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide

ZDM. Positive Displacement Flowmeter

Supply Voltage 10-30V DC V AC V DC/ VAC 10-30V DC VAC V DC/ VAC. (Pico-style) V DC/ (Micro-style) 10-30V DC

Miniature High Power Relay SRRHN/SRP

4-Beam-Turbidity Meter ITM-4

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

HS h e n EU omplia t 2002 / 9 5 / C

D5100 Industrial Differential Pressure Transducer

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Miniature I/P, E/P Transducer

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Unloading Valve Series R4U

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

09. MACHINE ACCESSORIES. 202 Moulding Supplies Edition 9 // MOULD SCREENS 09.2 MOULD ALIGN 09.

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Pressure Transmitter STK136,STK136Q

Mechatronic pressure measurement. Applications. Special features. Description

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Extended-Frequency SMA Connectors

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

M7100 Pressure Transducer

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240

Switch Disconnectors with Fuses

HD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min

ALUMAX. High Amperage Power Solutions

Thermometer in stainless steel with adjustable stem in stainless steel. Compression fitting for direct mounting or mounting in separate thermowell

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

Temperature sensors for automotive applications

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels. Threaded stud and

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

Low Voltage Alternators - 4 pole LSA 46.3

PRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES

Glycerine filled Bourdon tube pressure gauges EN 837-1

3867 en / a

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

INDUSTRIAL THERMOMETERS

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

3867 en / f. Alternators. LSA Pole Electrical and mechanical data

Presented By. NicolScales.com Contact Us

Product information. UP-DO Pump Series Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1.

TUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS

Zero cross function. DIN track mounting *2. Screw mounting

Load cell Pendeo Process and mounting kits

Reference thermometer Model CTP5000

Transcription:

PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0

8D-LT G/, / NPT or flange Microswitch with gold plated contacts High number of switching cycles Microswitch approved by UL and CS Intrinsically safe operation Wide range of temperature Shock and vibration tested to EN 67, Category, class and Pressure switch suitable for - C (-67 F) on request +8 C (+8 F) -0 C (-0 F) Technical features EN 67 Medium: For neutral, gaseous and liquid fluids, non-combustible Operation: Diaphragm Operating temperature range: Fluid (reliability) mbient (reliability) -0... +8 C (-0... +8 F) Temperature at switching element: -0... +8 C (-0... +8 F) ir supply must be dry enough to avoid ice formation at temperatures below + C (+ F) Media viscosity: Up to 000 mm /s Switching pressure difference/hysteresis: Fixed Repeatability: Repeatability: 0,... bar (.9... 9 psi): ±0, bar (.9 psi) 0,... 8 bar: (7.... 6 psi) ±0, bar (.6 psi),0... 0 bar: (,... psi) ±0,6 bar (8.7 psi),6... 6 bar: (.... psi) ±0,7 bar (0.8 psi) Life cycle of mechanical parts: 0 7 switching cycles Switching element: Microswitch with gold plated contacts Degree of protection: IP6 for DIN EN 7-80 (DIN 60) form connection IP67 for M x connection Mounting position: Optional Electrical connection: DIN EN 7-80 (DIN 60) form or M x IEC 97-- Housing: luminium (brass) Seals: EPDM, VMQ, NR Option selector 088 ir port G / 0 Flange / NPT Pressure range (bar) -... 0 0,... 0,... 8... 0... 6 6 Electrical connection DIN EN 7-80 (DIN 60) form 7 Mx IEC 97-- 8 DIN plug connection plug included in scope of supply Pressure range *) Max. switching pressure difference Max. over pressure *) Switching cycles press sensor Port size Weight Drawing Model lower range (bar) upper range (bar) (bar) (per min) body seals (kg) No. -... 0 0, 0, 6 00 L, anodized EPDM, VMQ Female, / 0, 088#7 0,... 0, 0, 6 00 L, anodized EPDM, VMQ Female, / 0, 088#7 0,... 8 0, 0,9 6 00 L, anodized EPDM, VMQ Female, / 0, 088#7... 0 0,,0 6 00 L, anodized EPDM, VMQ Female, / 0, 088#7... 6 0,, 6 00 L, anodized EPDM, VMQ Female, / 0, 088#67 -... 0 0, 0, 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0887 0,... 0, 0, 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0887 0,... 8 0, 0,9 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0887... 0 0,,0 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0887... 6 0,, 6 00 L, anodized EPDM, VMQ, NR Flange 0, 08867 *) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *) Max. values # Please insert O for ISO G, for NPT thread -0 For further information www.norgren.com/rail

8D-LT G/, / NPT or flange M x Connection plug not included, max. allowable voltage V Pressure range *) Max. switching pressure difference Max. over pressure Switching cycles press sensor Port size Weight Drawing Model lower range (bar) upper range (bar) (bar) (per min) body seals (kg) No. -... 0 0, 0, 6 00 L, anodized EPDM, VMQ Female, / 0, 088#8 0,... 0, 0, 6 00 L, anodized EPDM, VMQ Female, / 0, 088#8 0,... 8 0, 0,9 6 00 L, anodized EPDM, VMQ Female, / 0, 088#8... 0 0,,0 6 00 L, anodized EPDM, VMQ Female, / 0, 088#8... 6 0,, 6 00 L, anodized EPDM, VMQ Female, / 0, 088#68 -... 0 0, 0, 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0888 0,... 0, 0, 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0888 0,... 8 0, 0,9 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0888... 0 0,,0 6 00 L, anodized EPDM, VMQ, NR Flange 0, 0888... 6 0,, 6 00 L, anodized EPDM, VMQ, NR Flange 0, 08868 *) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *) Max. values # Please insert O for ISO G, for NPT thread ccessories Pressure port reducing nipple Surge damper Cover (via adjustment screw) Connector (included as standard in scope of supply of switch) Connector M x, -pin, 90 Connector M x -pin, straight 07767 (brass) 0777 (brass) 077 0700 06 (without cable) 0 (without cable) 0008 (stainless steel) 08 (stainless steel) Switching function p Connector DIN EN 7-80, form Microswitch SPDT Terminals - : Contacts close on rising pressure. Terminals - : Contacts open on rising pressure. p Connector M x Microswitch SPDT Terminals - : Contacts close on rising pressure. Terminals - : Contacts open on rising pressure. Switching capacity Micro-switch with gold plated contacts Load level Current type Load type U min (V) Max. permanent current Imax () at U (V) 8 60 0 Standard *) a.c. ohmic (e.g. contactors, a.c. inductive, solenoids) cos ϕ = 0,7 d.c. ohmic, 0,8 0, d.c. inductive, 0, 0, 0,0 L/R = 0 ms Minor *) a.c. ohmic *6) 0, 0, 0,7 0,08 0,0 (e.g. electronic d.c. inductive, *6) 0, 0,0 circuits) L/R = 0 ms Reference number: /min, Reference temperature: + C Spark quenching/intrinsically safe with diode with d.c. and inductive load: I max =, x I max. of table I min = (m) Creepage and air paths correspond to insulation group according to VDE Reg. 00 (except contact clearance of microswitch). *) Gold-plating not required as it would decay. Max. perm. inrush current (appr. ms) I a.c. = max. *) Gold-plating required (will not decay). *6) Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions. For further information www.norgren.com/rail -0

8D-LT G/, / NPT or flange Recommended circuit - spark quenching / intrinsically safe with d.c. voltage. Diode D in parallel to inductive load. Observance of correct polarity (positive pole to cathode). + (a.c./d.c.) Dimensioning specifications for quenching diode: Rated voltage at diode: U D, x Us p Rated current at diode: I N I Load Selection of a quick switching diode (recovery time trr 00 [ms]).. RC link in parallel to load in parallel to switching contact. Suited for d.c. and a.c. voltage. Dimensioning principles: U - (a.c./d.c.) R *) I *) D R C R in Ω 0, x R Load in Ω C in [µf] I Load in [] *) R Load, I Load Dimensions G / or / NPT G / or / NPT Dimensions shown in mm Projection/First angle 0 0, 7, 7 7, 7 9, Flange djustable switch point 0 fter releasing the locking screw Clockwise rotation = encreasing switch point nti-clockwise rotation = decreasing the switch point - + Switch point screw Locking screw, 7 O-ring x,, Electrical connection for plug conforming to DIN EN 7-80, form Electrical connection M x 9,, 0 0 M x -0 For further information www.norgren.com/rail

8D-LT x G/, / NPT, flange Microswitch with gold plated contacts High number of switching cycles Microswitch approved by UL and CS Intrinsically safe operation Wide range of temperature Shock and vibration tested to EN 67, Category, class and Pressure switches suitable for - C (-67 F) on request +8 C (+8 F) -0 C (-0 F) Technical features Medium: For neutral, gaseous and liquid fluids, non-combustible Operation: Diaphragm Operating temperature range: Fluid/mbient (reliability) -0... +8 C (-0... +8 F) Temperature at switching element: -0... +8 C (-0... +8 F) ir supply must be dry enough to avoid ice formation at temperatures below + C (+ F) Media viscosity: Up to 000 mm /s Switching pressure difference/hysteresis: Fixed Repeatability: Repeatability: 0,... bar (.9... 9 psi): ±0, bar (.9 psi) 0,... 8 bar: (7.... 6 psi) ±0, bar (.6 psi),0... 0 bar: (,... psi) ±0,6 bar (8.7 psi),6... 6 bar: (.... psi) ±0,7 bar (0.8 psi) Life cycle of mechanical parts: 0 7 switching cycles EN 67 Switching element: Microswitch with gold plated contacts Degree of protection: IP6 Mounting position: Optional Electrical connection: DIN EN 7-80 (DIN 60) form Housing: luminium (brass) Seals: EPDM Option selector DS-M 00 Thread form ISO G NPT Flange Port size G N F / Flange Pressure range switch (bar) 0,... 0 0,... 8 08,0... 0 0,0... 6 6 F Electrical switching function switch switch NO NC X NC NO Y NO NO O NC NC C Pressure range switch (bar) 0,... 0 0,... 8 08,0... 0 0,0... 6 6 Thread port connection plug included in scope of supply Pressure range *) Max. over pressure *) Switching cycles press sensor Port size Weight Drawing Model switch (bar) switch (bar) (bar) (per min) body seals (kg) No. 0,... 0,... 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#00*00 0,... 8 0,... 8 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#0808*00... 0... 0 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#00*00... 6... 6 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#66*00 0,... 0,... 8 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#00*00 0,...... 0 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#00*00 0,...... 6 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#06*00 0,... 8... 0 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#00*00 0,... 8... 6 6 00 L, anodized EPDM, VMQ Female, / 0, DS-M#06*00 * Please insert X, Y, O or C for electrical switching function see option selector # Please insert G for ISO G, N for NPT thread *) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *) Max. values Switching pressure difference see page -06 For further information www.norgren.com/rail -0

8D-LT x G/, / NPT, flange Flange connection plug included in scope of supply Pressure range *) Max. over pressure *) Switching cycles press sensor Port size Weight Drawing Model switch (bar) switch (bar) (bar) (per min) body seals (kg) No. 0,... 0,... 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF00*00 0,... 8 0,... 8 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF0808*00... 0... 0 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF00*00... 6... 6 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF66*00 0,... 0,... 8 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF008*00 0,...... 0 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF00*00 0,...... 6 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF06*00 0,... 8... 0 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF00*00 0,... 8... 6 6 00 L, anodized EPDM, VMQ, NR Flange 0, DS-MFF06*00 * Please insert X, Y, O or C for electrical switching function, see option selector on page -0. *) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *) Max. values Pressure range and switching pressure difference ccessories Pressure range (bar) Max. switching pressure difference lower range (bar) upper range (bar) Pressure port reducing nipple Surge damper Connector (included as standard in scope of supply of switch) 0,... 0, 0, 0,... 8 0,0 0,90,0... 0 0,,00,0... 6 0,0,0 07767 (brass) 0777 (brass) 0700 0008 (stainless steel) 08 (stainless steel) Switching function Switch : NO Terminals - : Contacts closed on rising pressure. Switch : NC Terminals - : Contacts closed on falling pressure. Switch : NC Terminals - : Contacts closed on falling pressure. Switch : NO Terminals - : Contacts closed on rising pressure. Switch : NC Terminals - : Contacts closed on falling pressure. Switch : NC Terminals - : Contacts closed on falling pressure. Switch : NO Terminals - : Contacts closed on rising pressure. Switch : NO Terminals - : Contacts closed on rising pressure. Switching capacity Micro-switch with gold plated contacts Load level Current type Load type U min (V) Max. permanent current Imax () at U (V) 8 60 0 Standard *) a.c. ohmic (e.g. contactors, a.c. inductive, solenoids) cos ϕ = 0,7 d.c. ohmic, 0,8 0, d.c. inductive, 0, 0, 0,0 L/R = 0 ms Minor *) a.c. ohmic *6) 0, 0, 0,7 0,08 0,0 (e.g. electronic d.c. inductive, *6) 0, 0,0 circuits) L/R = 0 ms Reference number: /min, Reference temperature: + C Spark quenching/intrinsically safe with diode with d.c. and inductive load: I max =, x I max. of table I min = (m) Creepage and air paths correspond to insulation group according to VDE Reg. 00 (except contact clearance of microswitch). *) Gold-plating not required as it would decay. Max. perm. inrush current (appr. ms) I a.c. = max. *) Gold-plating required (will not decay). *6) Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions. -06 For further information www.norgren.com/rail

8D-LT x G/, / NPT, flange Recommended circuit spark quenching / intrinsically safe with d.c. voltage. Diode D in parallel to inductive load. Observance of correct polarity (positive pole to cathode). + (a.c./d.c.) Dimensioning specifications for quenching diode: Rated voltage at diode: U D, x Us p Rated current at diode: I N I Load Selection of a quick switching diode (recovery time trr 00 [ms]).. RC link in parallel to load in parallel to switching contact. Suited for d.c. and a.c. voltage. Dimensioning principles: U - (a.c./d.c.) R *) I *) D R C R in Ω 0, x R Load in Ω C in [µf] I Load in [] *) R Load, I Load Dimensions G / or / NPT ~8 70 8 60 Dimensions shown in mm Projection/First angle 6, 7, 87 7, G/ Switch Switch djustable switch point fter releasing the locking screw Clockwise rotation = encreasing switch point nti-clockwise rotation = decreasing the switch point Switch point screw - + Locking screw For further information www.norgren.com/rail -07

8D-LT x G/, / NPT, flange Flange ~8 70 8 60 Dimensions shown in mm Projection/First angle, 7, ø 8 7, 6,, Switch Switch O-ring x, djustable switch point fter releasing the locking screw Clockwise rotation = encreasing switch point nti-clockwise rotation = decreasing the switch point Switch point screw - + Locking screw -08 For further information www.norgren.com/rail