WALL APPLICATIONS IN BUILDINGS EXCEPTIONAL R-VALUE. OUTSTANDING RESISTANCE TO MOISTURE. LONG TERM DURABILITY.

Similar documents
Gold Bond BRAND Gypsum Sheathing

HOMEGA DESCRIPTION. UNIQUE PATENTED PRODUCT ON THE MARKET US Patent No CAN Patent No

Note to Specifier: Use this product for coated glass-mat faced polyisocyanurate insulation boards such as Rboard.

ProGUARD Guide Specification

Closed cell expanded polystyrene (EPS) insulation with graphite.

September 24, 2011 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

About Insulation & R Value - cmhc.ca

Wall Insulation: Selection, Application and Specification

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

THERMOFOAM DESCRIPTION

Rainscreen. Insulation. Easy.

WALLTITE ECO Air Barrier System. Welcome

Expanded Polystyrene DataSheet

Technical Data Sheet

HYDROFOAM DESCRIPTION

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide

THE FOAMULAR HIGH DENSITY

A. Source Limitations: Obtain each type of building insulation through one source.

Roof & Deck Insulation / PLA BuyLine Insulation Systems for. Roofing Applications

1/2 in. (12.7 mm) and 5/8 in. (15.9 mm) glass mesh. It has an exceptionally hard, durable surface that can withstand prolonged exposure to moisture.

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

EXTRUDED POLYSTYRENE THERMAL INSULATION BOARDS ألواح البوليسترين بالبثق للعزل الحراري. A product of BITUMAT COMPANY LIMITED. Bitumat Co. Ltd.

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

RAY-CORE Structural Insulated Roof and Wall Panels

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

COMMERCIAL BUILDING APPLICATIONS

Tech-Crete Processors Ltd. Section February 5, 2013

Sept 30, 2004 Page 1

SECTION INSULATING CONCRETE FORMING (ICF)

Construction Standards PAGE

TECH SOLUTIONS THERMAX Insulation in Low Humidity Metal Buildings

SPECIFICATION GUIDELINE

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

ResidentialComplete WALL SYSTEMS

GROOVED CUT. Thickness of 1 in (25mm) and more

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Rigid Board Installation Builder s Guide

Prescriptive Wind Pressure Performance of Foam Plastic Insulation Used as Insulating Sheathing in Exterior Wall Covering Assemblies. TER No.

Rigid Board Installation Builder s Guide

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

Product Information Bulletin

Condensation - Prevention and Control

Science Doesn t Lie. FOAMULAR XPS Insulation Performs Better than EPS Insulation.

HEATLOK SOYA/POLARFOAM SOYA

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION

integrated Integrated Series nudura.com nudura.co.uk series

NORANDEX 1/4 EXTRUDED POLYSTYRENE FOAM INSULATION

Firestone Polyiso Boards

SPECIFICATION GUIDELINE

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

Foamular INSULATION FAMILY GUIDE FOR RESIDENTIAL APPLICATIONS

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

CommercialComplete WALL SYSTEMS. Visit Division7.owensCorning.com to view our new Division 7 thermal & moisture protection ebook!

Product Information Bulletin

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide

Thermasheath-XP. Insulation for Exposed Use

CommercialComplete Wall System

ProGUARD DP The Game-changing Wall System

Continuous Insulation Systems for Exterior Walls

O82018 Hunter Panels XCI Foil

Triton DCI Decoupling Mat

Product Information Bulletin

NOVAWRAP ASPIRE Q & A

Triton BK Backer Board & Tile Underlayment

Foam-LOK Spray-Applied Rigid Polyurethane Foam Insulation Medium Density

THERMAL AND AIR BARRIER WALL SYSTEM

SUSTAINABLE BUILDING WITH XPS TOP TO BOTTOM THE SINGLE LARGEST POINT SCORING OPPORTUNITY IN LEED * WE VE GOT YOU COVERED

DIVISION 07 SECTION 2100 Short Form Guide Specification THERMAL, AIR BARRIER AND WATER BARRIER WALL SYSTEM

(Project Location) (your firm's name)

Thermal Control in Buildings by John Straube (updated )

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

SECTION SPRAY FOAM INSULATION

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

MortarNet (updated to include Insect Barrier) Master Specification

FOAMULAR SUSTAINABLE BUILDING TOP TO BOTTOM WITH FOAMULAR XPS THE SINGLE LARGEST POINT SCORING OPPORTUNITY IN LEED + WE VE GOT YOU COVERED

TABLE OF CONTENTS HALO INSTALLATION GUIDE. THE ADVANCED RIGID INSULATION ENVELOPE PRINTED 2017

STRENGTH AND DURABILITY OF THE INSTALLED STONE

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

SECTION THERMAL INSULATION

May 19, 2006 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

INSTALLATION GUIDE EPS FOAM

Concrete Faced Insulated Perimeter Wall Panels. Durability. Sustainability. Energy Efficiency. Durable Finish & Superior Insulation in One Easy Step

A4/8 PS AW2324D Issue 10 May Permishield

SUBSTITUTION REQUEST (During the Bidding/Negotiating Stage)

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

PRP-108 Performance Standards and Policies for Structural-Use Panels

2006 Building Science Press All rights of reproduction in any form reserved.

Owens Corning PinkWrap Housewrap, the brand trusted to protect your home from moisture and the elements.

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

Summary of Test Results

Product Test Summaries Nichiha Fiber Cement Products Sierra Premium Boards

An Introduction to Spray Foam Insulation

Master Wall Inc. continuously tests our products and systems to meet the most current building codes.

Improve Energy Efficiency and Moisture Performance of Foundations

Transcription:

EXCEPTIONAL R-VALUE. OUTSTANDING RESISTANCE TO MOISTURE. LONG TERM DURABILITY. INSULATION THE NATURAL WAY. ON THE EXTERIOR. WALL APPLICATIONS IN BUILDINGS EXTRUDED POLYSTYRENE INSULATION

CONCRETE BLOCK WITH BRICK VENEER CAVITY WALL ASSEMBLY Placing Celfort 200 on the exterior of the concrete block wall, keeps the wall warm so that it is not subjected to temperature variations. This reduces the potential for expansion and contraction of the materials at different temperatures lessening the likelihood of cracked mortar joints. The thermal properties of Celfort 200 are virtually unaffected by the inevitable presence of moisture in the assembly. Many other insulating materials absorb water which results in a significant decrease in thermal resistance in wall configurations typical for most buildings. Celfort 200 is made in 16" and 24" (400 mm and 600 mm) widths. NEW CONSTRUCTION High Moisture Resistance Lightweight an STEEL STUD WITH BRICK VENEER CAVITY WALL ASSEMBLY Resists absorption of moisture driven through the brick, helping to keep water away from the inner wall elements while maintaining its thermal properties. Applying the insulation on the exterior of the steel studs, reduces the effect of heat loss through studs by conduction (thermal bridging). Does not contribute to corrosion of studs thus reducing the likelihood of wall damage and expensive repairs. CONCRETE SLAB ON GRADE, PERIMETER INSULATION Rigid and strong, less susceptible to damage at backfill stage. The PVC channels allow flexibility to easily install a variety of approved insulation protection systems or materials. Superior freeze-thaw resistance.

ION OR RENOVATION ance, Excellent R-Value, t and Durable. EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) Rigid and strong; providing an excellent substrate on which to install the finish. Compatible with common finishing systems. RETROFIT/UPGRADES IN THERMAL COMFORT Metal channels replace wood studs, minimizing installation time, reducing construction cost (significantly for large areas), and maximizing usable interior space. Foundations are areas of potentially high moisture presence. The thermal properties of the Celfort 200 insulation panels are virtually unaffected by moisture, making the Cel-Lok system a durable choice for an interior foundation insulation. Goes up quickly and easily, instantly upgrading the wall s thermal performance at the same time as interior renovations are performed. RENOVATION Very rigid and strong therefore it will not get damaged when furring strips (for attachment of siding) are nailed on top of insulation to the stud back-up wall. Its rigidity helps achieve a consistent finish when applied over the uneven surface of existing siding. Insulating over existing siding saves time, tear off costs, and dumping charges making it an effective and economical retrofit solution.

THE PERFECT MATCH! Celfort 200 AND THE CAVITY WALL THE THEORY Today s architects and engineers need to design wall assemblies which are efficient, cost effective and durable. Choosing Celfort 200, Extruded Polystyrene Insulation contributes to their success. To see why, let s take a closer look at the wall environment. Moisture From The Exterior And Interior The veneer, (masonry or concrete), in a cavity wall assembly fulfills several functions, including some protection of the insulation. However the commonly used "Rainscreen Design Principle" allows moisture to enter the cavity through the veneer and then escape via the weep holes at the bottom of the wall. Furthermore, warm air from the interior of the building carries vapour into the cooler wall cavity where it condenses into moisture. Moisture is present in all cavity wall applications, thus choosing a moisture resistant insulation product is imperative to achieving a consistent wall assembly R-value. The performance test data below shows why Celfort 200 is so often the insulation chosen by design professionals. PERFORMANCE COMPARISONS IN LABORATORY TESTS % 60 40 20 10 3% 17% 61% % 100 90 80 70 60 50 40 20 10 99% 69% 60% DAYS 100 90 80 70 60 50 40 20 10 4 100 0 CELFORT 200 BEADBOARD FOIL FACED (50 MM - TYPE I) POLYISOCYANURATE 0 CELFORT 200 BEADBOARD FOIL FACED (50 MM - TYPE I) POLYISOCYANURATE 0 CELFORT 200 BEADBOARD FOIL FACED (50 MM - TYPE I) POLYISOCYANURATE Fig. 1 Fig. 2 Fig. 3 WATER ABSORPTION IN FREEZE/THAW CYCLING TEST (ASTM C666-73 PROCEDURE A) AFTER 200 CYCLES Celfort 200, absorbs less than 3% of its total volume of moisture after being exposed to 200 freeze/thaw cycles. THERMAL RESISTANCE VALUE RETAINED AFTER 600 FREEZE/THAW CYCLES Insulation effectiveness is inversely proportional to water absorption. Celfort 200 s low water absorption keeps the insulation value at a maximum. TIME TO RECOVER INITIAL THERMAL RESISTANCE VALUE AFTER 600 FREEZE/THAW CYCLES Celfort 200 quickly regains exceptional R-value even after prolonged exposure to moisture and freezing conditions.

CAN/ULC-S701* Type III Extruded Polystyrene Rigid Foam Insulation. Celfort 200 s compressive resistance of 20 psi is an economical alternative to a psi product (CAN/ULC-S701 Type IV) for all building wall applications, including below grade exterior. Celfort 200 maintains its R-value even when exposed to moisture typically present in the walls of buildings. For these reasons architects, engineers, contractors and owners have been specifying and applying Celfort 200 since 1986. NOTE: For insulation in wall applications other than buildings referenced in the National Building Code of Canada Parts 3 and 9 consult the manufacturer before use. Product Description Made by a unique patented method called Hydrovac, a vacuum hydrostatic process, polystyrene foam insulation is extruded to form rigid panels while maintaining the consistent material density of choice. OC CELFORTEC INC. s product development research allows all products to be manufactured using HCFC s, meeting or surpassing government environmental regulations, while maintaining key physical properties. PERFORMANCE Insulating Effectiveness Celfort 200 has a thermal resistance of R-5 and R-5.4 per inch of thickness at mean temperatures of 75ºF and 40ºF respectively, when tested in accordance with ASTM C 518 or C 177. Moisture penetration significantly reduces the thermal effectiveness of many insulations. Moisture particularly affects the thermal performance of mineral fibre and loose fill insulations, and, to a lesser extent, polyisocyanurate and molded EPS (beadboard) panels. Celfort 200 however, absorbs less water than either molded EPS (beadboard) or polyisocyanurate insulation, due to its extruded surface skin and closed cell structure. The closed cell structure also accounts for its higher insulating value per unit of thickness (R/in; RSI/mm), than that of molded EPS (beadboard), fibrous or loose-fill insulation. The available shiplap edges minimize air leakage for added insulating effectiveness. Built in rigidity resists damage to panels during backfilling of soil or when used under slabs. Moisture Resistance Celfort 200 offers exceptional resistance to moisture of all types ground water, condensation, water leakage, freeze/thaw cycling for long-term retention of high R-value. Excellent hydrophobic properties stop wicking and provide superior dimensional stability under elevated moisture conditions. Long-Term Durability Celfort 200 is extremely durable because of its high compressive and flexural strength and is also resistant to the deleterious effects of mildew, fungus, corrosion and common soil acids. Ease of Handling, Installation Celfort 200 is lightweight, durable and impact resistant. These features facilitate handling, sawing, cutting and scoring, adding to installation efficiency. PRODUCT DATA Material Extruded polystyrene closed cell foam panel insulation with continuous skins on face and back surfaces. Weight 120-1 pounds/1,000 ft 2 for 1 inch thickness. Packaging 4 individual shrink wrapped bundles strapped together to form a unit, typically containing 1,536 board feet. Thermal Resistance: R-5 per inch at 75ºF (RSI 0.87 per 25 mm when tested at 24ºC) R-5.4 per inch at 40ºF (RSI 0.94 per 25 mm when tested at 4ºC) [R expressed in (ft 2 hr F / Btu), RSI in (m 2 ºC/W)] Classification: Type III, according to CAN/ULC-S701. *(replaces CAN/CGSB-51.20-M87)

CAN/ULC-S701* TYPICAL PHYSICAL PROPERTIES Property ASTM Method Celfort 200 TYPE III THERMAL RESISTANCE (1) C 518 or C 177 (ft 2 hr F/BTU) 5.0 (m 2 C/W ) 0.87 COMPRESSIVE STRENGTH, min. (2) D 1621 (psi) 20 (kpa) 140 WATER ABSORPTION D 2842 (% by volume) 0.70 WATER VAPOUR PERMEANCE, max. E 96 (perms) 2.26 (ng/pa.s.m 2 ) 1 FLEXURAL STRENGTH, typical (3) C 203 (psi) 44 (kpa) 0 LINEAR COEFFICIENT OF D 696 THERMAL EXPANSION (in/in/ F) 3.5 x 10-5 (mm/m/ C) 6.3 x 10-2 DIMENSIONAL STABILITY, max. D 2126 (% linear change) 1.5 MAXIMUM OPERATING TEMPERATURE ( F) 165 ( C) 74 FLAME SPREAD CLASSIFICATION (CAN/ULC-S102.2 tunnel floor test) >25 (1) Per inch (25 mm) thickness. (2) At 10% deformation or yield. (3) At 5% deformation or yield. STANDARD SIZES Celfort 200 Edge Size Thickness Butt Edge 24" x 96" 1", 1.5", 2", (also available in 16" x 96") 2.5", 3", 4" Shiplap 24" x 96" 1", 1.5", 2", 2.5", 3", 4" Metric equivalent available upon request. STANDARDS AND CODES COMPLIANCE CCMC Evaluation Report # 11246-L CAN/ULC-S701, type III *(replaces CAN/CGSB-51.20-M87) CAN/ULC-S102.2 OC CELFORTEC INC. P.O. Box 310 Valleyfield (Quebec) J6S 4V6 Tel.: 1-800-GET-PINK www.owenscorning.com ARCHITECTURAL NOTES 1. Certified Performance OC CELFORTEC INC. will provide test certification for published physical properties pertaining to our Celfort 200 product. 2. Jobsite Handling To protect Celfort 200 insulation and prevent discoloration and/or surface deterioration caused by excessive exposure to direct sunlight, it is recommended that in exterior applications, the product be covered as soon as practicable. 3. Vapour Retarders Assemblies should be evaluated for effectiveness and location of vapour retarders to avoid condensation and subsequent damage to structures. Vapour retarders shall be chosen and applied in accordance to applicable Codes for desired assembly. 4. Air and Water Infiltration All air and water infiltration requirements for a designed assembly shall conform to applicable Building Codes. 5. Flame Spread Classification Flame spread classification greater than 25 and less than 500 according to CAN/ULC-S102.2 (tunnel floor test). 6. Limiting Application Temperature Celfort 200 insulation must not be installed where it will be continuously exposed to temperatures above 165ºF (74ºC). 7. Warning Combustible Celfort 200 insulation is combustible and can be a fire hazard if improperly used or installed. Though it contains a flame retardant to inhibit ignition, it will ignite if exposed to fire of sufficient intensity. Do not expose it to open flame or other ignition sources during shipping, handling, storage, installation or use. 8. Interior Protection When used in buildings for human occupancy, Celfort 200 insulation must be protected by a minimum 1/2" (12.7mm) thick gypsum board, or approved equal, covering surfaces exposed after installation. The wall finish must be mechanically fastened in place as prescribed by the applicable Building Codes. 9. Exterior Finish Systems/Protection of Insulation Protect the exterior of Celfort 200 insulation, when used in a sheathing application, with masonry veneer, exterior siding or other approved exterior finishes. Mechanically attach protective finish to framing, as per applicable Building Code requirements. 10. Structural Bracing Celfort 200 insulation is not a structural material. Adequate diagonal/lateral bracing for structural framing is required in accordance with job and service load conditions and all applicable Building Codes. 11. Adhesives/Sealants Some of these products contain solvents that attack polystyrene insulation. Consult manufacturer to verify the chemical compatibility of solvents/sealants with Celfort 200 insulation. 12. Chemicals Celfort 200 insulation has good chemical resistance to many acids, caustics, salts, cements and mortars and poor resistance to some hydrocarbons and a number of other petroleum derivatives. Be sure to check with the supplier of the item regarding chemical compatibility. NOTICE: We trust the information given herein will be helpful. It is based on data and knowledge considered to be true and accurate and is offered for the user s consideration, investigation and verification. Please read all statements, recommendations or suggestions in conjunction with our conditions of sale which apply to all materials supplied by us. We shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of our materials not in accordance with our current printed instructions or for other than their intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made to us in writing within thirty () days from the date when the basis for it was, or reasonably should have been, discovered. Hydrovac is a registered tradmark of Owens Corning. Celfort and Cel-lok are registered trademarks of OC Celfortec Inc. Manufactured by OC Celfortec Inc., an Owens Corning company. THE PINK PANTHER & 2003 United Artists Corporation. The colour PINK is a registered trademark of Owens Corning. All rights reserved. 2003 Owens Corning. All rights reserved. INNOVATIONS FOR LIVING TM is a trademark of Owens Corning. Pub. No. 011291 Printed in Canada April 2003