LIQUID ALIPHATIC POLYURETHANE WATERPROOFING MEMBRANE

Similar documents
Polyurea F SPRAYED, HOT-APPLIED POLYUREA WATERPROOFING MEMBRANE

Impermax B 2k BITUMEN-BASED LIQUID WATERPROOFING POLYURETHANE MEMBRANE

Polyurea Rayston POLYUREA MEMBRANE FOR WATERPROOFING IN SPRAY APPLICATIONS EXTRA FAST CURING. It can be pigmented

WATERPROOFING OF BALCONIES. COLD-LIQUID APPLIED.

HYPERDESMO -ADY-E. One-component, transparent, glossy, aliphatic, elastic polyurethane liquid membrane. must be dry.

SECTION A. American Society for Testing and Materials (ASTM):

Permaroof 500 Liquid Membrane application onto:- Corrugated asbestos roofs

Continuous and union-free hybrid polyurea hot-sprayed liquid membrane for more demanding waterproofing, protection and sealing works.

HYPERDESMO Polyurethane liquid membrane for waterproofing & protection, easy application. alchimica.com. Page 1/5 DESCRIPTION

TDS. TECHNICAL DATA SHEET TECNOFLOOR T-3020 v / 6

SECTION A. American Society for Testing and Materials (ASTM):

FEATURES AND BENEFITS COVERAGE

2013 Product Catalogue

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

SECTION A. American Society for Testing and Materials (ASTM):

Seal- Krete High Performance System

SIKA CAR PARK DECK SYSTEM. Product. Scope. Appraisal No. 781 [2019] Appraisal No. 781 (2019) This Appraisal replaces BRANZ Appraisal No.

TDS. TECHNICAL DATA SHEET TECNOCOAT CP-2049 v / 5

Neoproof Polyurea L. Technical Characteristics. Description of the product. Applications

Ultra fast spray applied polyurethane membrane

Neoproof Polyurea R. Technical Characteristics. Description of the product. Applications

METHOD STATEMENT SIKALASTIC -680 AP SIKA LIMITED (VIETNAM)

Desmopol Application Guide for Corrugated Asbestos Roofs

TDS. TECHNICAL DATA SHEET TECNOFLOOR Tw-3040 v / 6

DIVISION 7 THERMAL AND MOISTURE PROTECTION Section Traffic Coatings

Liquid applied pure polyurea membrane

Neoproof Polyurea R. Technical Characteristics. Description of the product. Applications

Instruction Guide APPLICATION OF CIM TO CONCRETE

Technical Data Sheet EpoGlass PU Code: 65

Spray applied waterproofing membrane

Desmopol Application Guide onto Ply/OSB Deck

SECTION A. American Society for Testing and Materials (ASTM):

838 Coatings System Specification Single-Ply Restoration (838 SPR)

Dist. by: BEST MATERIALS Ph:

TDS. TECHNICAL DATA SHEET TECNOCOAT H-2049 EL v / 5

Flowfast SR (3mm) Technical Profile

Flooring and Bedding. RonaFloor SL. Self-smoothing seamless epoxy resin flooring system

SECTION A. American Society for Testing and Materials (ASTM):

RAPIDFOAM PAD 868 PREFABRICATED SHOCK-PAD FOR PLAYGROUND FLOORING

Westbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane.

TOPCOAT System Specifications Corrugated Transite Panels

WHO WE ARE? WE DEVELOP AND PRODUCE POLYURETHANE, POLYUREA AND POLYASPARTIC SYSTEMS FOR USE IN FLOORING / WATERPROOFING OUR COMPANY

Data Sheet Eco-Smart Membrane WS M1

Conforms to the requirements of ETAG Certificate: European Technical Approval No. ETA-05/0265

Spray applied polyurea membrane

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

3-component epoxy self-smoothing screed

MasterSeal NP 474 DESCRIPTION FIELD OF APPLICATION

CIM IG 13 11/06. Instruction Guide

Pacific Polymers Elasto-Deck 5000MR Guide Specification

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

EPOXY FLOORING SYSTEMS

ADLOCK 121 TWO-PART TOUGHENED ACRYLIC ADHESIVE TECHNICAL DATA SHEET

Spray applied modified polyurea membrane

Two component solvent-free epoxy system for creation of self-levelling floors. Gloss >4% <70% 83mg IR4

Membrane-based aliphatic polyurea for protection and waterproofing of surfaces

2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL. A. Two component liquid waterproofing for positive side waterproofing on mineral substrates

Flowcoat OP (0.3mm) Technical Profile

TDS. TECHNICAL DATA SHEET TECNOCOAT P-2049 EL v / 6

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

Cool-R is one component, highly reflective, seamless, waterproofing coating for new and refurbished roofs. It can be use on flat and slope roofs.

Fosroc Nitodek UR200 System

V-Pur S-84L V-PUR S-84L. Polyurethane Spray Foam System certified according to EN Description

FORMAK 629 CONCEALED WATERPROOFING SYSTEM

7F-420 C-FLOOR VARNISH E420 QS Epoxy varnish for mortars

Construction. Spray applied modified polyurea membrane. Product Description

Ultra Fast Curing Polyurethane Waterproofing Membrane System

Purtop System Roof SPRAY-APPLIED HYBRID POLYUREA WATERPROOFING SYSTEM FOR NON-TRAFFICKED ROOFS

SECTION A. American Society for Testing and Materials (ASTM):

Epoxol Floor. Two component solvent-free epoxy system for creation of self-levelling floors. Fields of Application. Properties/ Advantages

SilGrip* PSA529. Technical Data Sheet

TDS. TECHNICAL DATA SHEET TECNOCOAT H-2049 LV v / 7

Liquid applied polyurea hybrid membrane

DIVISION 9 FINISHES Section Floor Finishes

Flowfast SRQ (2mm) Technical Profile

A range of popular roof shades Spruce Acrylic Roof cannot be tinted.

Primeseal Bitum Polyurethane Based Waterproofing Membrane

Elasto-Kote Installation Guide

Fosroc Polyurea WPE. 18 CI/SfB: May constructive solutions. Fast setting, pure polyurea elastomeric waterproof coating.

PRODUCT DATA SHEET Sikalastic -590

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

Refer to Substrates & Surface Preparation.

WPM WATERPROOFING MEMBRANE

NSP SPECIALTY PRODUCTS Technical Data Sheet. NSP 120 High Performance Epoxy Coating

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

COOL BARRIER ROOF. High Solar Reflective Elastomeric Liquid Applied Roof Coating Water-Based for Big and Low Slope Roofs

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

SPRAY-APPLIED HYBRID POLYUREA OR PURE POLYUREA-BASED WATERPROOFING SYSTEM FOR TRAFFICKED ROOFS AND BRIDGES AND VIADUCT DECKS

Sikalastic -821 LV is a two part, elastic, crack-bridging, rapid-curing polyurethane membrane. Sikalastic -821 LV is for machine application only.

Construction. Pulastic Coating-221 W. 2 Component Polyurethane

Two component spray applied roof waterproofing membrane

SIGMAZINC 158. Revision of September 2008 DESCRIPTION. two component moisture curing zinc (ethyl) silicate primer PRINCIPAL CHARACTERISTICS

Membryl UV stable waterproofing membrane.

Wecryl 230 / -thix / -TT Waterproofing

SIGMAZINC 160. Revision of March 2007 DESCRIPTION. two component moisture curing inorganic zinc (ethyl) silicate primer PRINCIPAL CHARACTERISTICS

Non-sag, ultra low modulus, neutral cure silicone sealant for pavements

Flowcoat SK (0.35mm) Technical Profile

Pacific Polymers Elasto-Mat D&G Guide Specification

Transcription:

IMPERMAX A LIQUID ALIPHATIC POLYURETHANE WATERPROOFING MEMBRANE DESCRIPTION Single-component liquid waterproofing membrane. When cured, the product gives a colour-stable solid elastomeric membrane based on aliphatic polyurethane. APPLICATION Liquid waterproofing PROPERTIES Seamless, elastic, weather resistant membrane with good adhesion properties. Does not undergo yellowing or discolouration by sunlight. Aliphatic polyurethane. Non water dispersible. Technical Data INFORMATION ON THE PRODUCT BEFORE APPLICATION Chemical description Physical state Packaging Single component aliphatic polyurethante, solventborne Liquid Metal container 5 kg 10 kg 25 kg Non-volatile content (%) 81% Flash point Not determined FT Impermax A Page 1 of 5 Rev-12/8/12

Colour White Density 1,25 g/cm3 (23ºC) Viscosity Approximate values, Brookfield Temperature Viscosity (mpa.s) (ºC) 25 446 VOC content 19% 237 g/l Pot life 100 g, 23ºC: 8 hours INFORMATION ON THE FINAL PRODUCT Final state Solid elastomeric membrane Hardness 65A, 17D Shore Mechanical properties Maximum elongation: 85% Tensile strength: 1,7 MPa Chemical resistance Surface contact (0=Not recommended, 5=best) Temperature: 25ºC, 48 h Chemical Result Water 5 Acetic acid (10%) 1 Sodium hydroxide (40 g/l) 3 Xylene 3 isopropyl alcohol 2 Chlorinated water (500 ppm 5 trichloroisocyanuric acid) Acetone 2 Ammonia (3%) 5 Skydrol 4 Engine oil 5 Bleach 5 Hydrogen peroxyde 2 Diesen 4 Formol 37% 3 Sulphuric acid(10%) 4 Ethyl alcohol 3 White spirit 2 UV resistance Aliphatic-based polyurethane. Non yellowing FT Impermax A Page 2 of 5 Rev-12/8/12

Solar reflection Index (SRI) value ASTM E1980-01 100 (white colour, 2-6 m/s) APPLICATION GUIDELINES Recommended combinations Support requirements Option 1: Non traffic waterproofing Primer Rayston Epoxy 100 (200g/m2) Waterproofing Impermax A 2 kg/m2 two coats or las coat after Impermax In order to achieve a good penetration and bonding, support must be: 1.Flat and leveled (Impermax is self-leveling) 2. Compact and cohesive (pull off test must show a minimum resistance of 1,4 N/mm2). 3. Even and regular surface 4. Free from cracks and fissures. If any, they must be previously repaired. 5. Clean and dry, free of dust, loose particles, oils, organic residues or laitance. Recommended environmental conditions Support temperature should be between 0ºC and 40º. High moisture conditions can lead to bubble formation under the membrane surface. Preparation Treatment of critical spots is necessary, much in the same way as in th Impermax. Mixing Stir and homogeneize the product before use. Some of the contents settle during storage and must be redispersed. Allow some minutes to release air bubbles. Stirring should be done at low speed. If needed, the product may be thinned with up to 10% of Rayston solvent, as a viscosity adjustment. Never use universal or unknown solvents (e.g. white spirit or alcohols) Application and recommended quantities Apply by roller, brush, spreader or airless equipment. It is useful to apply in 2 differently coloured coats, at 1 kg/m2 each. Although not strictly necessary, it is strongly recommended to use entirely the product of the container. If there is some product left, ensure it is completely sealed after use. Curing time Curing time is dependent on the environmental conditions. Curing rate increases with temperature and humidity rises. The following table gives a rough estimation of the curing time under diverse conditions for a 1,5 kg/m2 coat. Conditions Dry to Total touch -15ºC <5 days >5 days 7ºC, 50% 2 days 3 days 20ºC, 60% 7 hours 24 hours 35ºC, 30% 4 hours 24 hours FT Impermax A Page 3 of 5 Rev-12/8/12

Ficha Técnica Recoating Possible up to 24 hours after curing of the underneath coat. Return to service Tool cleaning Cleaning and maintenance At 20ºC, 60% hr, after 24 to 48 hours Impermax A can be cleaned with solvent Rayston, acetone or alcohol. Once cured it cannot be dissolved. A maintenance work must be carried out regulary on the treated roofs according to the intended use. This work includes the following tasks: Leaf removal Grass, dirt, moss and other vegetation removal Keeping storm water system in good working order. Ensure gratings are in place, in order to prevent gutter obstructions. Check proper condition of several structures (flashing, seams, retaining walls...) Verification of possible damages due to improper use. If aesthetic appearance of the roof is an important issue, it is essential to regularly clean the surface with water (some mild detergent may be added), according to the use. For stain removal, a surface treatment with Rayston solvent or isopropyl alcohol may be attempted. Strong acids are totally inadequate. Some solvents may damage the membrane. If this happens, the affected area has to be cut and repaired with a new Impermax A application. Safety Impermax A contains isocyanates and flammable solvents. Always follow the instructions provided in the material safety data sheet and take the precaution described there. As a general rule, a suiable ventilation must be ensured and all ignition sources must be avoided. This product is intended to be used only for the uses and in the way here described. This product is to be used only by industrial or professional users. It is not suitable for DIY-type uses. Environmental precautions Other information Empty containers must be handled taking the same precautions as if they were full. Containers must be considered as hazardous waste, to be tranferred to an authorized waste manager. If there is some residual product in the containers, do no mix it with other substances without checking for possible dangerous reactions. This is a developmental product that is supplied for research and development purposes only. The information contained herein is merely preliminary because testing as to properties is not final. Further information including data that could change or add hazards associated with use, may be developed. Such information may be needed to evaluate and/or use this product properly. The user agrees that: use is undertaken at the user s sole risk, that the material is furnished as is, with all faults, without any warranty or guarantee; Gama RAYSTON and that Krypton Chemical shall not be liable for any damages, of whatever nature, arising out of the user s receipt and/or use of the material. Commercialization and continued supply are not assured. The user agrees that Krypton Chemical reserves the right to discontinue supply at any time. This data sheet supersedes all previous versions. FT Impermax A Page 4 of 5 Rev-12/8/12

Krypton Chemicals UK LTD Ashtree House, Ashbrook Lane Abbots Bromley, Rugeley WS15 3DW STAFFORDSHIRE GREAT BRITAIN tel. : 0044 1283 841 800 Fax : 0044 1283 841 801 info@kryptonchemicals.co.uk www.kryptonchemicals.co.uk Made by : Krypton Chemical SL c. Martí i Franquès, 12 Pol. Ind. les Tàpies 43890-l'Hospitalet de l'infant- España Tel: +34 902 908 062 Fax: +34 977 823 977 rayston@kryptonchemical.com www.kryptonchemical.com FT Impermax A Page 5 of 5 Rev-12/8/12