icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Similar documents
Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

Thermo Scientific Qtegra Intelligent Scientific Data Solution. Delivering quality. Driving productivity

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis

Functionality. Normal Operation

Image Area YOUR PRESCRIPTION FOR USP 232/233 COMPLIANCE. USP 232 / 233 Readiness Solutions and Services Overview

Optima 8x00 Series. ICP Optical Emission Spectrometers

EXPAND YOUR RANGE EXTEND YOUR RESOURCES. Avio 500 ICP Optical Emission Spectrometer

Trace Elements in Petrochemical Samples: Achieving Excellent Analytical Results

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

ICP Expert software. Technical Overview. Introduction

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

NO INTERFERENCE BETWEEN YOU AND BETTER THROUGHPUT. NexION 1000 ICP Mass Spectrometer. For research use only. Not for use in diagnostic procedures.

EU water analysis using the Thermo Scientific icap 7400 ICP-OES Duo

Optima 8x00 Series. ICP Optical Emission Spectrometers

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Increase productivity for environmental sample analysis using the SVS 2+ Switching Valve System for Agilent 5100 SVDV ICP-OES

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

SPECTROGREEN ICP-OES ANALYZER. A new view of analyzer technology and value

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Introducing the new Agilent 7800 Solution-Ready ICP- MS. Agilent Technologies 2015

Analytically Monitoring the Effect of Fracturing Activity

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES

Composition Analysis of Animal Feed by HR ICP-OES

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. :

OPTIMA 4000 DV Series of ICP-OES Systems

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

Analysis of elemental impurities in drug products using the Thermo Scientific icap 7600 ICP-OES Duo

Analysis of elemental impurities in drug products using the Thermo Scientific icap 7400 ICP-OES Duo

Thermo Scientific icap 7000 Series ICP-OES Accessories Guide

USABILITY BY DESIGN Every component of the Agilent 7900 ICP-MS is engineered for performance and reliability

Automating EPA 6020 Compliant Analysis with the Agilent 7900 ICP-MS and ESI prepfast Autodilution System

Multi-element determination in pharmaceutical preparations using the Thermo Scientific icap Q ICP-MS

The Determination of Alloying Elements in High-Carbon Steel using Radially Viewed Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES)

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

SGS Delivering Excellence in Compliant Extractables and Leachables Testing

Confident Quantitation

Table I: MCL and MRL Concentrations for Contaminants Monitored Under the Safe Drinking Water Act National Primary Drinking Water Regulations

Agilent Atomic Spectroscopy Solutions for Energy & Chemicals AA, MP-AES, ICP-OES, ICP-MS.

Tender Document. National Centre of Excellence in Analytical. Chemistry, University of Sindh, Jamshoro. Inductive Coupled Plasma (ICP -OES) ISSUED BY:

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

Agilent OpenLAB Chromatography Data System IT S TIME TO ACHIEVE MORE

Thermo Scientific icap Q ICP-MS

PinAAcle 500. Flame Atomic Absorption Spectrometer

Agilent 7900 ICP-MS RAISE YOUR EXPECTATIONS WITH THE NEXT GENERATION OF ICP-MS

Completing the performance picture.

Product Descriptions and Offerings

Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES

Agilent 7900 ICP-MS RAISE YOUR EXPECTATIONS WITH THE NEXT GENERATION OF ICP-MS

Confident Quantitation

Agilent solutions for contract research and manufacturing organizations

Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST.

Agilent 4200 Microwave Plasma-Atomic Emission Spectrometer CHANGE IS IN THE AIR

ACCURACY THE FIRST TIME. Bring Your Esoteric Assays In-House Routinely SCIEX DIAGNOSTICS MASS SPECTROMETERS

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Increase your lab ROI. Operating cost analysis Resource requirements

Avio 200 ICP-OES Flat Plate

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

SCIEX OS Software One Touch Productivity

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

Runs On Air. AGILENT 4100 MICROWAVE PLASMA ATOMIC EMISSION SPECTROMETER

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II AA Mercury Analyzer

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology

Thermo Scientific X-ray product range. For chemical and phase analysis of solids, liquids and powders

Thermo Scientific X-ray product range. For chemical and phase analysis of solids, liquids and powders

MultiQuant Software 2.0 with the SignalFinder Algorithm

TurboMass GC/MS Software

Correlation coefficient

REQUEST FOR TENDER. Supply of a Dual View (radial & axial) ICP-OES instrument Issue date 04 July 2014 Briefing session Closing date and time

Atomic Spectroscopy Solutions for Environmental Applications

HID Real-Time PCR Analysis Software v1.3

Increased Sample Throughput for ICP-OES Applied to U.S. EPA Method 200.7

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

testo 350. For emission testing and combustion analysis. Portable Emission Analyzer

Comparing an instrumental technique based on its

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

Transcription:

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

icap 7000 Plus Series ICP-OES Powerful multi-element performance for routine and research applications with the flexibility to analyze the most challenging sample matrices The innovative ICP-OES technology is driven by the Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) Software and the Element Finder plug-in. The plug-in reduces method development time and removes the need for wavelength selection by the user. This delivers powerful, high performance and low-cost analysis for both high-throughput routine and research laboratories. Element Finder plug-in selects interference-free wavelengths Automated method development with plasma optimization tool Long-term stability through gas MFCs and temperature control Intelligent monitoring of analytes with Qtegra ISDS Software The Thermo Scientific icap 7000 Plus Series ICP-OES provides low-cost, multi-element analysis for measuring trace elements in a diverse sample range. The instrument combines advanced performance with high productivity and ease of use, resulting in consistently reliable data, while ensuring compliance with global regulations and standards. Optimized sample introduction for different sample types Robust plasma generation for complex matrices Optical system design for sub ppb detection limits Charge Injection Device (CID) detector for high linear dynamic range Predefined and customizable reports on demand Thallium doublet at 190 nm. 2 3

Delivering powerful performance with advanced, easy-to-use technology This advanced technology enables maximum performance and flexibility to meet, and exceed, the analysis requirements of any substance - from drinking water to crude oil. It is achieved without the complication of a user interface, ensuring simple operation by analysts with any level of experience Recovery, % 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 Time, min Stability plot of phosphors and magnesium. P 177.495 nm axial Mg 279.553 nm radial Analyze challenging samples with a self-optimizing robust plasma delivered by the swing frequency RF generator. The innovative design of the icap 7000 Plus Series ICP-OES delivers powerful analytical performance and stability. The high resolution optics enable effective interference separation. At 200 nm, the resolution is 7 pm, enabling the simple analysis of complex line-rich samples without excessively elaborate deconvolution. The low number of optical surfaces reduces reflective losses and maximizes light transmission from plasma to detector for superior detection limits. The Echelle polychromator is thermostatically controlled to 0.1 C to achieve long-term stability with recalibration typically only required every 24 hours. The icap 7000 Plus Series ICP-OES features superior signal detection and a large working dynamic range due to its unique CID. The CID enables complete access to the full spectrum between 166 and 847 nm in both radial and axial views, with the additional functionality to perform post-run integration of previously unquantified elements. The user-friendly sample introduction system with push-fit connections ensures rapid assembly and disassembly for cleaning and maintenance. Alternative sample introduction components can be added to increase the speed of analysis or for the analysis of special sample types. 4 Total gas consumption of just 16 L min. Unique features, for example, the drain sensor removes the usual challenges often associated with ICP-OES analysis. 5

Laboratory optimization Enable your analytical team to achieve more with advanced instrumentation The icap 7000 Plus Series ICP-OES offers increased productivity as it requires minimal training for analytical teams and has rapid instrument start-up. Automated method development also simplifies routine analysis. Accessories are simple to connect to the sample introduction system and are controlled by the Qtegra ISDS Software plug-ins, which dramatically expand the power and performance of the instrument. Discreet sampling and auto-dilution Higher throughput, lower maintenance and auto-dilution reduce the time and cost of analysis. Auto-dilution enables calibration from a single stock solution and the automatic dilution of samples that exceed the calibrated range or show bad internal standard recoveries, eliminate the need for additional post-run analysis. The integrated Sprint Valve enables maximum sample throughput when combined with an autosampler. The Qtegra ISDS Software monitors data and makes decisions with respect to QCs and calibrations which are used to perform dilutions with the auto-dilution system. Hydride generation This is a simple solution for increasing the detection capability of the hydride forming elements. Confidence in the detection of these elements at sub ppb concentration is delivered by the following options: A basic hydride kit which enables both non and hydride forming elements to be determined simultaneously An integrated hydride generation accessory which enables maximum improvement in detection of the hydride forming elements The Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) Software and the Element Finder plug-in deliver quality and drive productivity. The intuitive and easy-to-use Element Finder plug-in automatically selects interference-free wavelengths and optimizes plasma conditions. Ease of use Simple workflows minimize the steps needed to perform a task, giving analysts more time to focus on other activities. The Get Ready feature takes your instrument from standby to ready-for-analysis through a fully automated process, saving time and ensuring consistent performance. Element Finder plug-in The Element Finder plug-in automates method development, selecting wavelengths suited to your analysis and optimizing the plasma with an advanced tuning procedure. This eliminates interferences before you know you have them, and ensures maximum analyte sensitivity for all matrices. Create a LabBook in five clicks and automatically start an intelligent workflow with a fully integrated QA/QC protocol. Integration of peripherals The plugin architecture of Qtegra ISDS Software enables the connection to multiple industry standard sample preparation devices and autosamplers. Common platform Qtegra ISDS Software is a control software supporting different analytical devices. This makes cross-training and the adoption of new instrumentation faster and easier, so you can expect increased flexibility in multi-technique laboratories. Automated reports and calculations Data is exceptionally easy to manage, removing the need for proactive monitoring. The icap 7000 Plus Series ICP-OES and Qtegra ISDS Software minimize the requirement for analyst interaction during the analytical determinations. Data handling Query Reporting LIMS Compliance 21CFR PART 11 Data security and access control Compliance management 6 7

Environmental and human health Powerful software and maximized instrument performance enable compliance with the latest regulations and legislation Agricultural screening Maximize sample throughput when screening for nutrients and toxic elements with the Thermo Scientific icap 7600 ICP-OES Radial. This instrument provides robust sample introduction and plasma generation to enable analysis of high matrix samples such as soil extracts. Productivity enhancing technology - such as the Sprint Valve - drastically reduces uptake and wash time, increasing the speed of analysis. When used in conjunction with extended rack autosamplers, the number of samples that can be analyzed unattended is dramatically increased, freeing the operator to perform other tasks. Environmental analysis Accurately quantify the elemental composition of a wide range of environmental samples. For challenging high solid samples such as sludge, the sample introduction and plasma generation efficiently process the matrix. For the analysis of drinking water, the icap 7000 Plus Series ICP-OES has the powerful detection capabilities required for the quantification of ppb concentrations. The simplified work flows of the Qtegra ISDS enable complex procedures specified by regulations to be easily adhered to using the automatic interference correction and quality control protocols. Short analysis time leads to a low quantity of waste being produced and low consumable requirements, minimizing both the cost of analysis and its environmental impact. Food production and safety Monitor key toxic elements during food production with the dual view system. The low detection limits achieved using the axial view enable analysis which fulfills the requirements of a range of food safety regulations. Higher concentrations, typically analyzed for the nutritional labelling of products, are easily determined with the radial view, which extends the linear range of the instrument. The use of electronic signatures and workflow ensures full traceability of an analytical result. Pharmaceutical and nutraceutical compliance Ensure you have qualified instrumentation to comply with current and future legislation, including the new General Chapters and one Supplemental General Chapter of the United States Pharmacopeia: <232> Elemental Impurities Limits <233> Elemental Impurities Procedure <2232> Elemental Contaminants in Dietary Supplements Qtegra ISDS Software provides full traceability of results and workflow, incorporating features to support compliance with CFR 21 Part 11, such as electronic signatures and audit trails. The dedicate validation solutions ensure fast instrument commissioning in your laboratory. 8 9

Industrial applications Powerful instrumentation delivers the highest performance for challenging samples Chemical QA and QC The icap 7000 Plus Series ICP-OES increases your laboratory productivity with superior stability. Confidence in your results is ensured with dedicated sample introduction for different sample types; minimizing the drift associated with sample introduction, often caused by matrix deposition. The CID detector has a wide dynamic range to enable the analysis of trace contaminants in high purity chemicals or to measure high concentration matrix elements. The Qtegra ISDS software has intelligent QC functions to ensure that data meets the highest standard. Petrochemical The dedicated radial system combined with a robust sample introduction system easily analyses a range of samples from crude oil to volatiles such as gasoline. The automated plasma optimization routine within the Qtegra ISDS software ensures optimum analysis conditions for the sample type. The icap 7000 Plus Series ICP-OES, combined with a dedicated oils autosampler which homogenizes samples prior to analysis, exceeds the requirements of demanding high-throughput applications such as the analysis of in-service oil. The addition of a Peltier cooled spray chamber enables analysis of elements at single figure ppb concentrations in volatile organic samples. Mining The icap 7000 Plus Series ICP-OES is field-proven with low gas consumption for remote sites. Robust and reliable, it is designed to maximize uptime with minimal user maintenance. Dedicated accessories such as the Ceramic D-Torch coupled with the high solids sample introduction kit allow for simple analysis of high matrix samples. The Qtegra ISDS software is easy to use: create a LabBook in five clicks and automatically start a simple intelligent workflow. High volume autosamplers allow the unattended analysis of samples over extended periods of time. Metals and materials The high-resolution Echelle optics and CID detector are especially well suited to the analysis of metals and materials where trace amounts of an element must be detected in complex matrices. The radial plasma instrument has robust matrix handling abilities, in order to minimize interferences. Both auto-dilution and monitored uptake and wash reduce carry-over, virtually eliminating the need to re-analyze expensive samples. 10 11

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories icap 7200 ICP-OES A simple multi-elemental alternative to Atomic Absorption and Microwave Plasma Technology, providing increased sample throughput and lower detection limit capability. icap 7400 ICP-OES Achieve an advanced level of stability, sensitivity and robustness for a range of applications with minimal user set-up and maintenance. icap 7600 ICP-OES Secure the highest sensitivity and optimum detection limits: maximize results with the integrated sample loop which efficiently delivers the sample to the plasma. Find out more at thermofisher.com/icp-oes For Research Use Only. Not for use in diagnostic procedures. 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. BR43247-EN 0517