The better way to build TM

Similar documents
The better way to build TM

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Plan /Submission Requirements

SIP Homes: Built for a Lifetime of Comfort and Value

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

Framing Methods Structural Components

CODE COMPLIANCE, STRENGTH AND SAVINGS IN ONE PANEL

'Rose Avenue Project'

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

9.36. Energy Efficiency

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

The Advantage ICF System. Installation Detail Drawings. The Advantage ICF System. Recommendation: Review the Advantage ICF System Installation Videos.

INFORMATION SHEET. Dealer name: Complete mailing address: Complete courier address: (courier will not deliver to P.O. box)

Issue Date: April 2003 Release: I. Product Specifications

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

Garage/Accessory Structures

HOUSE ADDITIONS A guide to the plans required when applying for a Building Permit

THE FLORIDA BUILDING CODE

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

LP OSB Sheathing & Structural 1 Sheathing

SIPs over a steel frame Raised SIP floor

TYPICAL BEARING WALL FRAMING

BUILDING INSULATION. Residential Product Guide

Carpenter Level 2 Rev. September 2017

PRESENTATION PLAN A MODEL COMPARISON FLOOR CONSTRUCTION

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

THE SPENCER RESIDENCE J&S ARCHITECT

Genesis. Light-Steel Structural Projects. Build with the Global Green Building Experts

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

City of High Point Airport Overlay District Noise Level Reduction Design Standards

DESIGN FORM. Rapid River Rustic, Inc. Cedar Log Homes and Fencing B.I. PHONE: CROSS-SECTION ENGINEER STAMP ARCHITECT STAMP

Thermal Characteristics of Exterior Building Wall (Above Heritage Building

Typical Single-Story Framing Section

One and Two Family Additions

Changes. With respect to Energy efficiency 2006 Code is 22% better than 1997 Code Code 37% better than 1997 Code

Administrative Changes

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

POST AND FRAME STRUCTURES (Pole Barns)

2010 National Building Code Adoption and Associated Process Changes

Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Section 1 - Introduction 1.1 Introduction Welcome to Fox Blocks. You have made an excellent decision to use Fox Blocks Insulated Concrete Forms (ICFs)

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

POST AND FRAME STRUCTURES (Pole Barns)

R-Matte Plus-3: Insulation for the Building Envelope

Formulating a Korea Industrial Standard for light-frame wood construction

GARAGE MAIN FLOOR PLAN

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

Section Downloads. Background. Load Development Outline. Types of Loads ANSI/ASCE 7. Section 07: Load Development. Download & Print. Version 2.

1.0 - PRODUCT DESCRIPTION

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Floor Truss Ribbon Board Load Path. Overview Revised 3/24/2017

RESIDENTIAL DETACHED ACCESSORY STRUCTURES

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

10 EXTREME BASEMENT PANELS

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

The better way to build TM. Installation Manual NAILBASE PANELS

Applying for Permits to build a new house in Linn County

A Homeowner s Guide to Renovation and Addition Permits

Use of Energy Efficient Wood Structural Insulation Panels in Seismic Regions

Building for Energy Efficiency Part 2 Advanced Framing Workshop. Objectives for this presentation...

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

The Homeowner s Building Application Checklist for Constructing a Residential Addition

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

2003 International Residential Building Code

WOOD I-JOIST AWARENESS GUIDE

GARAGE MAIN FLOOR PLAN

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15

Structural Technical Report #2 By Robert Whitaker

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

Residential Building Permits

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

MID-RISE DESIGN & CONSTRUCTION

Panelize Your Dreams. With Enercept, The Better Way To Build. Structural Insulated Panels The Builders Choice

Interior FRT Wood. References of Previous Model Building Codes

Flanking Transmission at Joints in Multi-Family Dwellings. Phase 1: Effects of Fire Stops at Floor/Wall Intersections

9.36 Energy Efficiency

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Supplementary Standard SB-12. Energy Efficiency For Housing

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Section 5 Crew Requirements

Residential Plan Review for New One and Two Family Dwellings

Date of Authorization APRIL 29, 2004 BMEC Authorization BMEC # BMEC Application #A

CHAPTER 6 INTERNATIONAL RESIDENTIAL CODE

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

STOP ANTIQUATED BUILDING PRACTICES STEP INTO THE 21st CENTURY

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

Main Floor Plan Scale: 1/8"=1'-0"

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

Transcription:

The better way to build TM Product Catalog

Exterior Wall SIP The Exterior Wall SIP is the most common panel manufactured by Thermapan with numerous applications in residential and commercial construction alike. Exterior Wall SIPs are highly structural, distributing loads across an even surface and bearing three times the load of conventional 2x framed walls. Thermapan SIPs replace several components of conventional framing, including studs, insulation, vapour barrier and air barrier. A 20 foot wall section can be installed in just 30 minutes by a trained crew. 4 Exterior Wall SIPs are suitable for partition wall assemblies. The assembly is UL&ULc listed and has a STC 50 sound transmission rating. SIP party walls are faster and easier to install than concrete block or stick frame party walls. Ideal for townhouse, apartment, hotel/motel and other multi-unit projects. Party Wall Assembly 1 Thermapan 6.5 SIP 2 Resilient Channel 3 Sonosecur Panel 4 5/8 Gypsum Type C (two layers each side) 4 2 3 1 Exterior Side 7/16 OSB Interior Side 7/16 OSB Length 8, 9, 10, 12, 14, 16 Thickness 4.5, 6.5, 8.25 R-Value R19, R29, R38 2

Roof & Ceiling SIP Non-vented roof and ceiling insulation is critical to energy efficient building design. Thermapan Roof SIPs are an increasingly popular option for home, cottage and commercial construction. Flat Ceilings: Ideal for flat, big box store or green roofs; faster installation and reduced labor savings. Vaulted Ceilings: SIPs make vaulted roofs easy to frame and insulate, while providing superior load strength. Panels can be covered with shingles or any other standard roof sheathing. Exterior Side 7/16 OSB Interior Side 7/16 OSB Length 8, 9, 10, 12, 14, 16 Thickness 6.5, 8.25, 10.25, 12.25 R-Value R29, R38, R48, R58 Roof Span Chart (L/360) SIP Splines Lumber Splines Panel Spline Lumber Thickness 30 psf 40 psf 50psf 30 psf 40 psf 50psf Dimension Dimension 6.5 3 x5.5 13-0 12-0 10-6 2x6 16-0 14-6 13-0 8.25 3 x7.25 14-0 13-0 11-0 2x8 16-0 16-0 15-0 10.25 3 x9.25 16-0 14-0 12-0 2x10 16-0 16-0 16-0 12.25 3 x11.25 16-0 15-0 13-0 2x12 16-0 16-0 16-0 Uniform live load and 10 psf dead load as shown. 16 ft. length is maximum manufactured. 3

Floor SIP Commonly used for easy floor construction in additions, sunrooms and pier foundations, as well as for living spaces above garages. Floor SIPs are non-vented and therefore provide true insulation, giving you a comfortable floor to walk on. Floor SIPs are very easy to install. Typical conventional floors for sunrooms and additions that take 2-3 days to build can be assembled in a matter of hours. Because of a panel s continuous bond between the OSB and EPS, SIP floors keep your living space warm in the winter and cool in the summer. Floor for residential addition Living space above garage Exterior Side 7/16 OSB Interior Side 7/16 OSB Length 8, 9, 10, 12, 14, 16 Thickness 6.5, 8.25, 10.25, 12.25 R-Value R29, R38, R48, R58 Floor Span Chart (Standard Term) Panel Thickness Lumber Spline Maximum Span 6.5 2x6 12-0 8.25 2x8 13-9 10.25 2x10 15-4 12.25 2x12 16-0 Note: Vibration controlled floor span table. Please contact Thermapan s Engineering Department for more details. 4

Nailbase Panel Nailbase SIPs are suitable for applications involving a) insulation improvements, or b) when a structural wall or roof panel is not required Exterior Walls: Nailbase panels are suitable for adding insulation to an exterior wall, by removing its existing siding and installing the panel directly to the structure. New siding is then affixed to the nailbase. Added Roof Insulation: For those flat or vaulted roofs requiring extra insulation. Simply remove the roof shingles or other, and install the nailbase panel to the structure. New shingles are then affixed to the nailbase OSB. Flat Ceilings: Can be installed on the underside of a roof truss to make an insulated ceiling. 2 1 1 2 3 Vaulted Ceilings: Timberframe and log homes typically have structural ceilings with maximum 4 o/c purlins and 1.5 (minimum) pine or cedar finish. 3 Exterior Side 7/16 OSB (opt: SmartPanel TM ) Interior Side None Length 12, 14, 16 Thickness 4, 6, 7.75, 9.75, 11.75 R-Value R18, R28, R37, R47, R57 Industrial/Commercial: Wall and ceiling on steel-frame building 5

PWF Foundation SIP PWF Foundation SIPs are specifically engineered for below grade uses. The pressure-treated exterior sheathing resists wood decay, backed by a limited lifetime warranty. PWF SIP foundations have numerous advantages over traditional concrete foundations: Dry basements with no mustiness No framing required to insulate and finish basement No cracking Fast construction no concrete to cure Structurally Strong: An 8.25 thick PWF SIP can support 30,000 lbs of loading. With an R-value of R-38 to R-48, PWF Foundation SIPs far exceed traditional concrete basement construction and exceeds Insulated Concrete Form (ICF) basements. Note: Refer to the Thermapan Installation & Reference Manual for recommended installation. For additional installation details, refer to local building code and the following building standards: Canada: CAN/CSA S406-M92:Construction of Preserved Wood Foundations USA: ANSI / American Forest & Paper Association (AF&PA): PWF 2007: Permanent Wood Foundation Design Specification Exterior Side 1/2 PWF Plywood (minimum) Interior Side 7/16 OSB Length 8, 9, 10 Thickness 8.25, 10.25 R-Value R38, R48 Full-sized basement Crawl-space basement 6

Frost Wall SIP Frost wall SIPs are the ideal solution for slab on grade applications. They are installed in one step as compared to pouring concrete or laying blocks and applying insulation separately. Ideal solution for a solid, unexcavated foundation (e.g. garage area, cottage with no basement) beneath the level of frost penetration in order to prevent building shift due to frost action. Extremely fast installation compared to traditional concrete pour or laying block. Note: Refer to the Thermapan Installation & Reference Manual for recommended installation. For additional installation details, refer to local building code and the following building standards: Canada: CAN/CSA S406-M92: Construction of Preserved Wood Foundations USA: ANSI / American Forest & Paper Association (AF&PA): PWF 2007: Permanent Wood Foundation Design Specification Exterior Side 1/2 PWF Plywood (min.) Interior Side 1/2 PWF Plywood (min.) Length 8, 9, 10 Thickness 6.5, 8.25, 10.25 R-Value R29, R38, R48 Slab on grade application 7

1380 Commerce Parkway Fort Erie, Ontario, Canada L2A 5M4 Phone: (905) 994-7399 Toll-Free: 1-877-443-9255 Fax: (905) 994-7400 E-mail: info@thermapan.com www.thermapan.com Distributed by: TPC-C 01/10