Strengthening Laboratory Management Toward Accreditation. Module 6: Quality Assurance

Similar documents
Establishing Chemistry QC Ranges

Strengthening Laboratory Management Toward Accreditation. Module 3: Inventory Management

Prepared by Date Adopted Supersedes Procedure # Adapted from HPTN Policy. Review Date Revision Date Signature

Quality Control in clinical laboratory. Kanit Reesukumal, M.D. Assistant Professor Clinical Pathology Mahidol University

Strengthening Laboratory Management Toward Accreditation. Module 2: Work Area Management

2015 Version MODULE 8. Laboratory Testing. SLMTA Trainer s Guide

Plan Subject Index Number Section Subsection Category Contact Last Revised References Applicable To Detail PRINCIPLE:

SLMTA Management Framework Page 1

QC results in true real-time

Common Deficiencies

Advances in Biochemistry & Applications in Medicine

What is SLMTA? SLMTA A Mentoring and Training Program with Structured Improvement Methodology. Improvement Projects. Workshop #1.

Verifying New Reagent Lot Performance

Verification of Method XXXXXX

Establishing Quality Control Target Values and Standard Deviations for Hematology Instrumentation

Laboratory Accreditation Test Validation: A Brave New World for Anatomic Pathology

Quality Assurance by Liz McChlery

The International Haemostasis External Quality Control Program

Quality Control for Chemistry Laboratory Dynacare Kasper Laboratories Procedures

QUALITY CONTROL & STANDARD OPERATING PROCEDURES EHI JAMES OCHEIKWU.

Proficiency Testing Turning Pitfalls into Positive Outcomes

CAP Regulatory Potpourri for Microbiologists. Christi Wojewoda, MD Director of Clinical Microbiology 2/2/19

Competency Assessment: Is Your Program Competent? Judy Sullivan, MS, MT(ASCP)SBB HAABB Meeting April 30, 2013

QUALITY CONTROL/QUALITY ASSURANCE IN THE MOLECULAR MICROBIOLOGY LABORATORY

Urinalysis and Body Fluids CRg. Laboratory Regulation. Laboratory Regulation for Quality Assessment. Unit 1 B. Quality Assessment

What is? An Overview of Operational Processes

Strengthening Laboratory Management Toward Accreditation. Module 7: Specimen Collection and Processing

AAG PRINCIPLE SPECIMEN. REF (150 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

IQCP for the Akers Bio PIFA PlussPF4 Rapid Assay

2015 Version MODULE 6. Quality Assurance. SLMTA Trainer s Guide

Traceability and Measurement Uncertainty within Clinical Biochemistry UKAS

M-TP PRINCIPLE REF ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

IQCP Inspector Training Scenarios

Measurement Uncertainty Guide. ISO Accreditation Program

LabGuide 13 How to Verify Performance Specifications

IQCP for the Akers Bio PIFA Heparin Platelet Factor 4 Rapid Assay

Most Common POCT Deficiencies

TNI s NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM (NELAP) Changing to the 2009 Standard

Meets Standards AFTER REVIEW ( 2.5 pts) Fail to meet the standard safety precautions, counseled one time

CLIA Personnel & Competency Requirements

Quality Management. Carlos Bachier, MD

Guide to Fulfillment of Laboratory Results Comparability Requirements

Total Analytic Error From Concept to Application

Marcia L. Zucker, Ph.D. ZIVD LLC

APFCB. Improving Laboratory Performance Through Quality Control. Designing an Appropriate QC Procedure for Your Laboratory QUALITY CONTROL

ASVCP quality assurance guidelines: control of general analytical factors in veterinary laboratories

JGK TRAINING PROGRAMME MODULE 2: METHOD VALIDATION AND MEASUREMENT OF UNCERTAINTY IN VETERINARY LABORATORIES PRACTICAL COURSE

Laboratory Developed Tests. William Castellani, MD Inter-regional Commissioner Clinical Pathologist, Penn State Hershey Medical Center

Ann E. Snyder, MT (ASCP) CMS/CCSQ/SCG Div. of Laboratory Services CLIA

Total 170 files quick download in editable form by e delivery

Ready, Set, Test! AACC Conference Mass Spectrometry in the Clinical Lab: Best Practice and Current Applications September 17-18, 2013 St.

WAIT! Ready, Set, Test! Financial Disclosure. Research/Educational grants/consulting/salary support

Angelia Dooley, MT, BS CRI Educational Surveyor. Terri Wolek, MBA, MT(ASCP) Bio-Rad Laboratories Senior Sales Product Manager

SEED HAEMATOLOGY. SNCS IQAS Online the quality control solution for the haematology laboratory

MODULE 2A GENERAL MANAGEMENT SYSTEM REQUIREMENTS

Ensuring Compliance. When Adding a Specialty or Subspecialty. > LabGuide

MAINTENANCE OF QUALITY IN THE LABORATORY Dr Tom Hartley Quality Manager : Royal Hobart Hospital Senior Research Fellow : University of Tasmania

CLIA Corner. In This Issue... Common Deficiencies. Proficiency Testing Personnel Micro Quality Control

APB PRINCIPLE SPECIMEN. REF (300 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

IQCP for Streamlined ID QC of Vitek 2

Quality Control Program

Total 170 files quick download in editable form by e delivery

WEQAS: what is it and what does it mean?. Celia Critchley Point of Care Co-ordinator Warrington and Halton Hospitals NHS Foundation Trust

Date. Albumin measurements are used in the diagnosis and treatment of numerous diseases primarily involving the liver and/or kidneys.

A Practical Guide to Internal Quality Control (IQC) For Quantitative Tests in Medical Laboratories, Version 2.0 February 2015

Fully Automated EIA System. True open flexibility.

Successful performance in proficiency testing (PT) is required

NEW YORK STATE DEPARTMENT OF HEALTH CLINICAL LABORATORY EVALUATION PROGRAM. Crosswalk of Proposed Revision to General Systems Standards

Guide to Fulfillment of Validation and Verification of Examination Requirements

Sysmex Educational Enhancement and Development No

Interlaboratory Data Management Software

PAB PRINCIPLE. Kit Reorder # ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Project Proposal Form

Guidelines for Use of Back-Up Equipment and Back-up Clinical Laboratories for Safety Testing in DAIDS-Sponsored Clinical Trials

Designing QC Activities to More Precisely Manage Analytical Accuracy and Patient Risk

Edward F. Askew PhD Askew Scientific Consulting

Validating, Verifying, and Evaluating Your Test Methods: It s NOT a Regulatory Exercise!

Building an Effective Laboratory QC System

CLSI C60: Assay Validation & Post-Validation Monitoring

Proficiency Testing Corrective Action Checklist:

USE OF INFORMATICS IN ANALYTICAL QUALITY

MODULE 6 DATA QUALITY & CLEANSING. CRIS Manual of Operations April

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Basic Good Laboratory Practice. Christopher Jerome, B.Vet.Med., Ph.D

RAJESH NAIR DIRECTOR CALF-NDDB, ANAND, GUJARAT

QAM-Q-113 Responsibilities of the Laboratory Quality Assurance Officer

KENYA ACCREDITATION SERVICE

Current Topics in NYS Clinical Laboratory Oversight

Diagnostic Accreditation Program 2015 Laboratory Medicine Accreditation Standards FAQ

True Walkaway Automated Urinalysis, Chemistry to Microscopy The CLINITEK AUWi System Answers for life.

Documenta tion and Records

External Quality Assurance Services. EQAS Explained

Discover the Importance of Third Party Quality Control

Products & Services. Catalog

Inspecting Cytopathology

Lucia M. Berte Laboratories Made Better! P.C. Broomfield, Colorado, USA

The All-Commons Checklist

QUALITY ASSUARENCE IN THE FOOD CONTROL LABORATORIES

Medical Cannabis Laboratory Approval Program

BIOEQUIVALENCE TRIAL INFORMATION

Transcription:

Strengthening Laboratory Management Toward Accreditation Module 6: Quality Assurance

Key Message My lab assures accurate and reliable testing processes. Desired Outcome Consistently accurate and reliable test processes Pre-analytical Analytical Post analytical 2

Tasks Ensure the Quality Manual with quality assurance policies and procedures is accessible to and reviewed by all staff Module 10: Why Was the Outdated Version Used? Validate new equipment, reagents, and supplies Module 3: Did You Receive What You Ordered? Module 8: Validation of Test Results Review discordant rates and determine appropriate action Cross-cutting: Workstation Set-up 3

Tasks Review occurrence log for patterns/trends and take corrective action Module 2: Safety Incident Role Plays Periodically observe/assess accuracy of personnel s work and take corrective action Module 1: Competency Assessment 4

Bonus Question Which section - Key Area of Work in the Framework has three tasks that refer to SOPs? Answer Section or Key area of Work 6 Note tasks 6.2, 6.10 & 6.11 Additional related tasks 1.4, 1.6, 1.7, 7.3, 8.1, 10.1 5

Tasks 6.2 - Ensure the QC material is tested according to SOP 6.10 - Customize site-specific SOPs as needed 6.11 - Ensure that SOPs are read and understood by staff 6

Using Standard Operating Procedures Standardizing Best Laboratory Practices

Job Aid depicting a Standard Operating Procedures - SOP 8

Activity: Using Standard Operating Procedures Purpose To write and follow a simple SOP on handwashing What will you need? Handout 1: Hand Washing Article Job Aid 1: SOP Template Job Aid 2: Annotated SOP Flipchart pages & markers What will you do? Read Handout 1 for OVERNIGHT HOMEWORK Use Handout 1 and Job Aid 1 & 2 as needed to write a simple 7-step SOP on hand washing Record the SOP on the flipchart pages One group to demonstrate the SOP written by another group Participate in the classroom discussion 20 minutes for writing 9

10

Demonstration Time Let s see if these SOPs are - Complete Easy to follow Yield Accurate & Consistently Reliable Results 11

Another Bonus Question Name one Checklist Item that defines how to use SOPs? Checklist Items 1.5, 1.6, 1.7, 1.8, 3.4, 3.7, and 8.7 12

Tasks Establish acceptable ranges for control material Track test performance (e.g. Levey-Jennings chart) for trends Review records of environmental checks and QC trends to assess impact on testing and take corrective action Monitor reagent performance Enroll in EQA program, monitor results, and take corrective action 13

Activity: Is QC That Important Purpose To voice and examine the behavior and attitude applied at the worksite regarding quality control. What will you need? Worksheet: QC Program Questions What will you do? Complete the Worksheet as homework the evening before this activity Participate in the classroom discussion for each question on the Worksheet Share your viewpoints openly and respectfully throughout the discussion and listen to others in the same manner. 40 minutes 14

Knowing where you are and where you want to be starts with creating the right graph. Is There More to QC Than Just Plotting the Data? 15

Wrong Patient Results Can: Endanger patient lives. Prolong suffering. Add significant cost (money and time) to patient treatment. The right QC approach will detect and prevent errors. 16

Categories of QC Quantitative Measures the quantity of an analyte Numeric 5.2 mmol/l Semi-quantitative Measures the quantity of an analyte Estimate trace, moderate, +1, +3 Qualitative Presence or absence Positive, negative, growth, no growth, reactive, nonreactive

Statistical QC Mean ( x ) the average of a set of values primary indicator of accuracy measure of systematic error (error in a given direction) Standard deviation (SD) used to measure dispersion/scattering of a group of values around a mean primary indicator of precision measure of random error ( error in any direction) 18

Mean x = S x i N X i = individual value N = number of individual values 19

Standard Deviation SD = S (x i x ) 2 N-1 S = sum (of the differences) X i = individual value X = mean of individual values N = number of individual values 20

Confidence Limits Based on normal distribution of results (a bell-shaped frequency curve) a control result will have the following confidence limits: 68% will be 1 standard dev. above and below the mean 95% will be 2 SD above and below the mean 99% will be 3 SD above and below the mean 95% confidence limits are the most important limits used. Gaussian Curve 68.26% 95.46% -3s -2s -1s x +1s +2s +3s 21

Levey-Jennings Chart 22

Activity: Is There More to QC than Just Plotting the Data? Purpose To demonstrate control range and rule selection s effect on the error detection level of a QC system. What will you need? Worksheet 1: Normal Control Worksheet 2: Data Points Worksheet 3: L-J Charts What will you do? Work individually during the first part of the activity to complete Worksheet 1 For the second half, work with a partner (pairs) to chart data points using Worksheet 1, 2 & 3 Simple arithmetic used in the worksheets Apply different rules and assess level of error detection 25 minutes 23

Establishing Quality Control Range Step 1: Run new control daily for 20-30 data pts. Run in parallel with current control material All new controls must be within the manufacturer s product package insert range 24

Step 2: Calculate from the 20-30 data points of the new control: - the mean - the standard deviation (1 S.D.) From the mean and standard deviation, calculate: +/- 1 S.D.; +/- 2 S.D.; and =/- 3 S.D. 25

The following information was included in the control s package insert: Chemistry Normal Control Lot # 13427N Expiration Date 15/04/XX Analyte Mean ( ) SD Creatinine 80 umol/l 10 umol/l You analyzed 30 control samples on your chemistry analyzer, the Illustra 200, and calculated the following values based upon your instrument s control results: Chemistry Normal Control Lot # 13427N Expiration Date 15/04/XX Analyte Mean ( ) SD Creatinine 81 umol/l 4 umol/l Complete the following table using the information above Values Using the Package Insert s Values Using Your Instrument s 80 81 + 1 SD 90 85 +2 SD 100 89 +3 SD 110 93-1 SD 70 77-2 SD 60 73-3 SD 50 69 68% of the data will fall between (± 1SD) 70-90 77-85 95% of the data will fall between (± 2SD) 60-100 73-89 99% of the data will fall between (± 3SD) 50-110 69-93 26

Analyte: Lot #: Cape Clinic Laboratory L-J Chart for Illustra 200 Chemistry Analyzer Creatinine Control Material: Normal Units: Exp Date: SD From: May 1, 20XX Through: May 20, 20XX Use This Graph to Create and Plot the Package Insert Values C o n t r o l V a l u e +3 SD + 2 SD + 1 SD X - 1 SD - 2 SD -3 SD DAY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Use This Graph to Create and Plot the Instument's Calculated Values SD C o n t r o l +3 SD + 2 SD + 1 SD X 27

Analyte: Cape Clinic Laboratory L-J Chart for Illustra 200 Chemistry Analyzer Creatinine Control Material: Normal Units: umol/l Lot #: 13427N Exp Date: 4/15/XX 80 SD 10 Package Insert Values From: May 1, 20XX Through: May 20, 20XX C o n t r o l V a l u e 110 100 90 80 70 60 50 +3 SD + 2 SD + 1 SD X - 1 SD - 2 SD -3 SD DAY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Instument's Calculated Values 81 SD 4 C o n t r o l V a l u e 93 89 85 81 77 73 69 +3 SD + 2 SD + 1 SD X - 1 SD - 2 SD -3 SD DAY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 28

1 2s rule and 1 3s rule violations using the instrument s mean and SD chart values. Day Normal Control Value 1 2s Violation 1 3s Violation 1 80 2 85 3 77 4 72 5 84 6 88 7 94 8 81 9 74 10 78 11 83 12 87 13 86 14 75 15 71 16 74 17 80 18 81 19 81 20 90 4 1 It makes a difference what control rule(s) is/are applied to accept or reject a run. 4 rejections using the 1 2s rule versus 1 rejection using the 1 3s rule. 29

Common QC Terms Control Rule - a decision criteria to assess whether an analytical run is in-control or outof-control. Single-rule uses a single criterion or a single set of control limits such as 1 3s or 1 2s. Multirule uses a combination of decision criteria such as 1 3s /2 2s /R 4s. _ Analytical Run - the interval ( time or a group of samples) for which a decision on acceptability (in-control or out-of-control) is made. 30

Choice of Quality Control Rules Control rules should be carefully selected to maximize error detection and minimize false rejection The best set of control rules will vary from method to method and will be based upon: the allowable error required by the test the imprecision and inaccuracy of your method 31

How QC Works for You Calculate the mean and SD of the control material for a single data population. Use the calculated mean and SD on the QC chart. Use the right QC rules for your method Plot the control values versus time on a control chart. If a significant change occurs in accuracy or precision, then the QC rule failures alert you to the change. Investigate, resolve, and document the rule failure before patient results are reported. 32

Periodic Review Daily review of control values and control charts by the technologist before accepting or rejecting the analytical run. Weekly review of QC data and charts by the supervisor Monthly review of QC data and charts by the director of the laboratory Periodic quality audits by the quality assurance department 33

Cape Clinic Laboratory L-J Chart for Illustra 200 Chemistry Analyzer Analyte: Creatinine Control Material: Normal Units: umol/l Lot #: 13427N Exp Date: 15/04/XX 81 SD 4 From: May 1, 20XX Through: May 20, 20XX C o n t r o l V a l u e 93 89 85 81 77 73 69 +3 SD + 2 SD + 1 SD X - 1 SD - 2 SD -3 SD DAY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Control Material: Abnormal Lot #: 13436A Exp Date: 15/04/XX 228 SD 8 o C 252 +3 SD 34

Internal and External Internal QC- detecting problems during routine laboratory operations. External Quality Assessment (EQA) A group of laboratories analyze the same specimens and submit their results to an external facility. Compares your laboratory to a peer group with regard to accuracy and precision of your method. Types of EQA Peer Comparison Proficiency Testing 35

Activity: Workstation Set-up Purpose To create and organize an efficient and productive workstation using elements developed from each module. What will you do? Participate in the classroom s discussion Integrate key concepts from earlier activities What will you need? Laboratory Accreditation Preparedness Checklist 15 minutes 36

URINALYSIS DAILY Q.C. LOG AND MAINTENANCE Multistix 10 SG: Chek-Stix Combo Pak: lot #: SG101 Positive Control Negative Control lot # P83 lot # N83 exp. date 11/11/XX exp. date 1/15/XX exp. date 1/15/XX EXPECTED negative neg neg neg 1.010-1.025 6.0-7.0 neg 0.2-1 neg neg neg RESULTS positive trace - 250 pos trace - 80 1.000-1.015 8.0-9.0 trace- 100 2.0-8.0 pos mod - large trace-moderate Date C l units mg/dl mg/dl mg/dl EU/dl e a n C a l Control Glu Bili Ket S.G. ph Prot Urobili Nit Blood Leuk Initials 2/03/XX negative neg neg neg 1.0 2O 6.5 neg 0.2 neg neg neg LLC positive 250 pos 40 1.0 O5 8.5 30 8.0 pos large mod 3/03/XX negative neg neg neg 1.0 2O 6.5 neg 0.2 neg neg neg LLC positive 250 pos 40 1.0 O5 8.5 30 8.0 pos mod mod 3/03/XX negative neg neg neg 1.0 2O 6.5 neg 0.2 neg neg neg LLC positive 250 pos 80 1.0 15 8.5 30 8.0 pos large mod negative 1.0 positive 1.0 negative 1.0 positive 1.0 37

AFB Stain Log Manufacturer: Microtrek, Inc ZN Carbolfuchsin Decolorizer Methylene Blue Results Initials Date 1Z 1D 1M 1S - A LLC 7/8/XX 1Z 1D 1M 2S- A LLC 7/8/XX 1Z 1D 1M 1S - A AT 9/8/XX 1Z 1D 1M 2S- A AT 9/8/XX 1Z. 2D 1M 1S - A LLC 13/8/XX 1Z. 2D 1M 2S- A LLC 13/8/XX Expiration Date Code Lot Number Expiration Date Reagent Reagent Code Lot Number TB Ziehl Neelsen Carbolfuchsin 1Z C837 2/11/XX 2Z TB Decolorizer (3% acid alchohol) 1D D837 2/11/XX 2D D954 15/12/XX TB Methylene Blue 1M B837 2/11/XX 2M Manufacturer Reagent Code Microtrek Positive (M. gordonae) 1S Microtrek Negative (E.coli) 2S QC-589N QC Slide Lot Number QC-589P Positive control expected result: red bacilli Negative control expected result: blue bacilli Interpretation: A = Acceptable control results F = Control results are Not acceptable Complete an Occurrence Report Form if results are not acceptable. Comments: Expiration Date 4/7/XX 4/7/XX Supervisor Review: Theresa Rhinehardt Date: 31/08/XX 38

Glucometer QC Maintenance and QC Log Calibration /Test Strip: Control Level LOW NORMAL HIGH Lot Number #654 / # 977 Lot Number L835 N721 H854 Expiration Date 7/06/XX / 12/12/XX Expiration Date 2/1/XX 2/1/XX 2/1/XX Glucometer #2: Outpatients SN #2875S Daily: Verify test strip matches with display Run three control levels each day of use & plot With New Lot# of Strips : Change code chip Run three control levels As Needed: Change Battery Clean Glucometer with a damp cloth Opened Date Expected Range (mmol/l) 10/04/XX 13/04/XX 08/04/XX 2.5-3.5 4.5-5.5 21.0-23.0 Opened Expiration Date of Vial (90 days) 9/07/XX 12/07/XX 07/07/XX Date Display Lot # matches Test Strip Lot #? Control Level Control Result (mg/dl) QC Plotted Initials Low 2.7 Normal 4.9 High 22.1 Low 3.0 3/06/XX Normal 5.0 High 22.4 ABL Low 2.8 5/06/XX Normal 4.6 High 21.7 RSM 30/05/XX RSM Low Normal High Low Normal Action Log Date Action Item Initials High 30/05/XX New batteries installed, notified supervisor - one set of batteries available RSM 5/06/XX New Lot number of test strips in use; code chip inserted RSM 39

Date Kit Lot Number Kit Expiration Date QC Lot Number u HCG QUALITY CONTROL LOG QC Expiration Date Control Results Control Line Present SA 721 N 15/12/XX negative + / - Y / N SA 721 P 15/12/XX positive + / - Y / N 12/06/XX SA 721 15/12/XX SA 721 N 15/12/XX negative + / - Y / N SA 721 P 15/12/XX positive + / - Y / N 11/06/XX SA 721 15/12/XX Corrective Action: Date: negative + / - Y / N positive + / - Y / N Initials LLC Initials: TY Date Patient Name RESULT LOG BOOK (example) uhcg Control Line Present Initials 11/06/XX Ramos, Lucinda positive LLC Martek, Elizabeth negative LLC Caspella, Janice negative LLC 12/06/XX TY King, Mary negative 40

Excerpts from Workstation s SOP Quality Control: Built-in Control The appearance of a control line in the C region must appear on the membrane for a test to be valid and for a result to be reported. Document the control line result on the.. If the colored line fails to appear in the C region, then Qualitative Quality Control: A positive and negative quality control material must be performed and recorded in the uhcg Quality Control Log for the following instances: A. each day. B. when opening a new If either the positive or negative Q.C. is unacceptable, then. 41

Activity: What Would You Do? Purpose To integrate the module s lessons and apply them to the case scenario. What will you need? Handout: Case Study Scenarios What will you do? Divide into groups of 4-5 Select a spokesperson for your group Formulate specific action steps to address the scenario from the Handout. The group s spokesperson presents the proposed steps during the 2 minute class report. 5 minutes 42

What Would You Do? You notice that only one staff member performs testing on EQA (External Quality Assurance) samples. In fact, the EQA survey was not performed last week because that staff member was on holiday. When you questioned the other staff members they explained they are uncomfortable performing EQA tests. During the same discussion, you discover that the staff member who usually performs the tests has been running the samples 5 times to make certain he has the correct result. You know patients samples are not to be handled in this manner, and it does not reflect your testing process. How should you handle EQA surveys at your facility? 43

Tasks Ensure the Quality Manual with quality assurance policies and procedures is accessible to and reviewed by all staff Validate new equipment, reagents, and supplies Review discordant rates and determine appropriate action Review occurrence log for patterns/trends and take corrective action 44

Tasks Periodically observe/assess accuracy of personnel s work and take corrective action Ensure the QC material is tested according to SOP Customize site-specific SOPs as needed Ensure that SOPs are read and understood by staff 45

Tasks Establish acceptable ranges for control material Track test performance (e.g. Levey-Jennings chart) for trends Review records of environmental checks and QC trends to assess impact on testing and take corrective action Monitor reagent performance Enroll in EQA program, monitor results, and take corrective action 46