Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Similar documents
Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

150 mm. 1/8 BSPP brass male compression fitting with locknut included

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

Platinum Resistance Thermometer (PRT) Selection Guide

Article on Selection & Uses of right temperature sensors

Cable Selection Guide

5. How to Select and Use the Right Temperature Sensor

SURFACE TEMPERATURE SENSORS

How To Select And Use The Right Temperature Sensor

1. TEMPERATURE MEASUREMENT USING ELECTRICAL TECHNIQUES

Platinum Ceramic Resistance Elements

GENERAL INFORMATION ABOUT RESISTANCE THERMOMETERS

Thermal-Tab and Thermal-Ribbon Sensors

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

Proven Capabilities. Features and Benefits. Watlow provides:

In most industrial applications, temperatures are typically

M/s. INDUSTRIAL FABRICATORS.

4 RESISTANCE THERMOMETRY

uk.rs-online.com (UK) (International)

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

Troubleshooting RTDs and Thermocouples

Nickel Temperature Sensors 1/12

Proven Capabilities. Features and Benefits. Watlow provides:

Data sheet chainflex CF887

Automotive air or oil temperature Appliances cooking temperature. MOUNTING DIMENSIONS (for reference only)

Thermocouple Accuracies Tolerance classes for thermocouples to IEC : 1982.

Carbon film resistors

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

Platinum Temperature Sensors

Platinum Chip Temperature Sensors with Connection Wires to EN PCA design

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

Nickel Temperature Sensors 1/15

Thermocouples and RTD

Reference thermometer Model CTP5000

HEADLESS TYPE RESISTANCE THERMOMETERS

Compact Module. Enhanced Category 5 FTP Cabling System

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Thermometer Probes. for accurate temperature measurement. specialists in the design & manufacture of temperature measuring equipment for over 30 years

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

7. EXTENSION LEADS AND COMPENSATING CABLE

SERV-RITE Wire and Cable

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media

Ignition Leads, Plugs and Safety Caps. Perfection built in

Overview. A thermocouple assembly generally has four major components:

Thermometer Probes. for accurate temperature measurement. specialists in the design & manufacture of temperature measuring equipment for over 30 years

International Thermocouple and Extension Grade Wire Color Codes

SafeX110 Single Core Flexible Tinned Copper Cable

International Thermocouple and Extension Grade Wire Color Codes

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

THERMOMETER PROBES FOR ACCURATE TEMPERATURE MEASUREMENT 2019


Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

Omnigrad T TST310. Technical Information. RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring

SECTION 2: PROBES. Page 2-1

Resistance Temperature Detectors

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

TEMPSENS Instuments (I) Pvt. Ltd is a part of Pyrotech group which was established by four technocrats in 1976 at Udaipur, with our first product as

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

Thermocouple temperature sensor omnigrad T -TSC 310

MEHRAN UNIVERSITY OF ENGINEERING AND TECHNOLOGY, JAMSHORO Sensors & Actuator for Automatic Systems LAB # 01 RESISTIVE TEMPERATURE TRANSDUCERS

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

Thermon. Cellex TubeTrace. Tubing Bundles BSX TM. Self-Regulating Heating Cable. Now with IEC Ex Product Specifications

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems

Frequently Asked Questions about Platinum RTD Elements

Process Variables. Process Variables. Temperature Strain Level Flow Pressure

Instrumentation & Data Acquisition Systems

Realization of ITS-90 from K through K: One Company s Approach

PRODUCT SELECTION GUIDE

Data sheet chainflex CFSPECIAL.182

Infinite Thermal Solutions Inc. Thermocouples and RTDs

Photo: HELUKABEL. Robotic Cables H 1

INDUSTRIAL TEMPERATURE SENSORS

RTDs. Offered by. Phone: (203) Fax: (203) Specialists in Valves, Controls, Pneumatics, Fluid Measurement

Electric cables. CRANES APPENDIX

Section 2 Index PAGE 2-I. Metal Sheath and Ceramic Thermocouple Assemblies. AccuTru Sensor Technologies 2-1. Spring Loaded Hex Nipple w/ Head 2-2

Innovative Temperature Measurement in Heat Treatment Processes

Thin Film Platinum RTDs. HRTS Series. Datasheet

Mineral Insulated Stainless Steel & Alloy Sheathed Thermocouples & Transducer Cables & Probes

SERV-RITE Wire. Product Description Page. Thermocouple and Extension Wire

measure Temperature Probes temperature probes thermocouple, PT100 (RTD) & NTC thermistor response times handle types lead types applications

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

ANSI and IEC Color Codes for Thermocouples, Wire and Connectors

THERMOWELL ASSEMBLIES & THERMOWELLS INDEX


MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

Transcription:

Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641 237-1657 237-1629 Tubular ceramic encased Pt100 elements Thin film Pt100 element housed/potted in a ceramic sheath, 5mm dia. x 35mm long Class B to IEC 751: 2008 Single element, 2 or 4 wire configurations Available with stranded 7/0.2mm silver plated copper PFA Teflon insulated leads, or 1/0.4mm solid nickel wire with removable glassfibre sleeving 50 or 450mm lead lengths, or 10mm bare wire version Sensor temperature rating: -50 C to +250 C PFA Teflon types -50 C to +450 C bare nickel/glassfibre types Ordering information: Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code 5mm 35mm 2 wire 7/0.2mm SPC Teflon 50mm 70641766 237-1641 5mm 35mm 4 wire 7/0.2mm SPC Teflon 450mm 70641767 237-1657 5mm 35mm 4 wire 1/0.4mm Nickel + Glass* 450mm 70641765 237-1635 5mm 35mm 2 wire 1/0.4mm Nickel 10mm 70641764 237-1629 *Glassfibre sleeving is removable from bare wire nickel leads

Need RTD Cable or Pt100/Pt1000 Detectors? RTD Extension Cable 4 core (10 or 25 metre reel) Platinum Resistance Thermometer Extension Cable Silicone Rubber Insulated Silicone rubber insulated cable for extending Platinum Resistance Thermometers Can be used to extend up to 4 wire RTD configurations Commonly used with Pt100Ω thermometers but suitable with other types Pt130/500/1000Ω etc. 4 core silicone rubber insulated 7/0.2mm tin plated copper conductors, twisted together with silicone rubber outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 Good electrical and mechanical properties, highly flexible, resistant to oils, acids and other adverse fluids Good heat resistance up to 200 C Insulation rating -40 C to 200 C Supplied in 10 or 25 metre reel lengths Type Conductors mm² Cores (4 core) Jacket Reel Length Allied RS order Code Code RTD 7/0.2mm 0.219 2x Red / 2 x White Brown 10 metres 70657147 827-5823 RTD 7/0.2mm 0.219 2x Red / 2 x White Brown 25 metres 70644361 455-4242 Overall sheath Dimension (approx.) 4.0mmØ

RTD Extension Cable 4 & 6 core PFA Platinum Resistance Thermometer Extension Cable, PFA insulated & screened 4 core (cores: 2 x red / 2 white) 6 core (cores: 4 x red / 2 x white) PFA insulated cable for extending Platinum Resistance Thermometers High temperature to 260 C, extruded PFA Teflon construction Commonly used for Pt100Ω thermometers, also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 & 6 core available to extend 2, 3 or 4 wire RTD configurations, the 6 core can be used to extend 2 x 3 wire duplex (dual element) configurations Construction PFA insulated 7/0.2mm tin plated copper conductors, twisted cores with nylon cord, tin plated copper braided screen with PFA insulated outer jacket Cores colour coded Red & White in accordance with IEC-751, black outer jacket Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids Insulation rating -75 C to 260 C See below for available reel lengths Type Conductors mm² Cores Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 x 4 Yes Black 10 metres 70646175 611-8078 RTD 7/0.2mm 0.219 x 4 Yes Black 25 metres 70646176 611-8090 RTD 7/0.2mm 0.219 x 4 Yes Black 50 metres 70657148 827-5827 RTD 7/0.2mm 0.219 x 4 Yes Black 100 metres 70657150 827-5836 RTD 7/0.2mm 0.219 x 6 Yes Black 25 metres 70646177 611-8107 RTD 7/0.2mm 0.219 x 6 Yes Black 50 metres 70657151 827-5839 Overall sheath Dimension (approx.) 4 core: 3.2mmØ 6 core: 3.8mmØ

RTD Extension Cable 4 core PTFE (10 & 25 reel lengths) Platinum Resistance Thermometer Extension Cable, PTFE insulated & screened PTFE insulated cable for extending Platinum Resistance Thermometers High temperature to 260 C, wrapped PTFE tape construction Can be used to extend 2, 3 or 4 wire RTD configurations Commonly used for Pt100Ω thermometers, also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 core PTFE insulated 7/0.2mm silver plated copper conductors, twisted cores, Mylar tape, silver plated copper braided screen with PTFE insulated outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 + black outer jacket Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids, steam, gasses etc. Insulation rating -75 C to 260 C Supplied in 10, & 25 metre reel lengths Type Conductors mm² Cores (4 core) Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 10 metres 70644773 492-9775 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 25 metres 70642885 290-4976 Overall sheath Dimension (approx.) 3.5mmØ

RTD Extension Cable 4 core PVC (10, 25 & 50 reel lengths) Platinum Resistance Thermometer Extension Cable, PVC insulated & screened PVC insulated cable for extending Platinum Resistance Thermometers Can be used to extend 2, 3 or 4 wire RTD configurations Commonly used for Pt100Ω thermometers but also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 core PVC insulated 7/0.2mm tin plated copper conductors, twisted cores, polyester tape & nylon cord, tin plated copper braided screen with PVC insulated outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 with black outer jacket Heat resistant PVC to 105 C Good for general purpose cable, highly flexible & waterproof Insulation rating -10 C to 105 C Supplied in 10, 25 & 50 metre reel lengths Type Conductors mm² Cores (4 core) Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 10 metres 70644772 492-9753 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 25 metres 70642884 290-4954 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 50 metres 70646179 611-8129 Overall sheath Dimension (approx.) 4.4mmØ

Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A, B and 1/3DIN For use from 50 C to +500 C Thin film construction Suitable for surface & immersion applications where protected Vibration resistant Specifications: Sensor type: Pt100 (100 Ohms @ 0 C) Construction: Thin film, 10mm tails Temperature range: -50 C to +500 C Ice point resistance: 100Ω Fundamental interval (0 C to 100 C): 38.5Ω (nominal) Self-heating: <0.5 C/mW Thermal response: 0.1s Stability: ±0.05% Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt100 2 x 5.0mm Class A 70646146 611-7788 Pt100 2 x 5.0mm Class B 70646148 611-7801 Pt100 2 x 5.0mm Class B 70642888 290-5070 (Packet of 5) Pt100 2 x 10mm Class A 70643577 362-9799 Pt100 2 x 10mm Class B 70641762 237-1607 Pt100 2.0 x 10mm 1/3DIN 70643578 362-9812 Pt100 2.0 x 2.3mm Class A 70643579 362-9834 Pt100 2.0 x 2.3mm Class B 70643580 362-9840 Pt100 2.0 x 2.3mm 1/3DIN 70643581 362-9856 Pt100 Elements (continued) Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt100 1.2 x 1.6mm Class A 70646834 666-7362 Pt100 1.2 x 1.6mm Class B 70646831 666-7353

Pt100 1.0 x 3.0mm Class A 70646833 666-7359 Pt100 1.0 x 3.0mm Class B 70646832 666-7356 Pt100 2.0 x 5.0mm 1/3 Din 70656467 814-0162 Pt100 1.2 x 4.0mm Class B 70656468 814-0165 Pt100 1.2 x 4.0mm Class A 70656469 814-0169 Pt1000 Elements, Thin Film (1000 Ohm) Pt1000 elements to IEC 751 Class A and B For use from 50 C to +500 C Thin film construction Suitable for surface & immersion applications where protected Vibration resistant Specifications: Sensor type: Pt1000 (1000 Ohms @0 C) Construction: Thin film, 10mm tails Temperature range: -50 C to +500 C Ice point resistance: 1000Ω Fundamental interval (0 C to 100 C): 385Ω (nominal) Self-heating: <0.5oC/mW Thermal response: 0.1s Stability: ±0.05% Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt1000 2.0 x 10.0mm Class A 70643582 362-9907 Pt1000 2.0 x 10.0mm Class B 70643583 362-9913 Pt1000 2.0 x 10.0mm 1/3 Din 70656472 814-0178 Pt1000 1.0 x 3.0mm Class B 70656470 814-0171 Pt1000 1.25 x 1.7mm Class B 70656471 814-0175

Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or B 100Ω Ohms @ 0 C Single or dual element Platinum coil wire-wound construction sealed inside a high purity alumina ceramic body Optimum performance & stability Temperature range 200 C to +650 C Specifications: Sensor type: Pt100 (100 Ohms @ 0 C) Construction: Wire-Wound, 10mm tails Temperature range: -200 C to +650 C Ice point resistance: 100Ω Fundamental interval (0 C to 100 C): 38.5Ω (nominal) Self-heating: 0.02 to 0.3 C/mW Thermal response: <0.4s (secs. to 63% of final value in water @ 1m/s) Measuring current: 1mA Tolerance Class: In accordance with IEC 60751 W0.15 (Class A) -100 C to +450 C W0.3 (Class B) -196 C to +660 C Continued:

Single element: Resistance Tolerance Class Diameter ( D ) Length ( L ) Allied code RS order code Pt100 Class B 1.5mm 8mm 70646153 611-7851 Pt100 Class A 1.5mm 8mm 70646155 611-7873 Pt100 Class B 1.5mm 15mm 70646154 611-7867 Pt100 Class A 1.5mm 15mm 70646151 611-7839 Pt100 Class B 2.8mm 15mm 70646150 611-7823 Pt100 Class A 2.8mm 15mm 70646152 611-7845 Pt100 Class B 2.8mm 25mm 70646147 611-7794 Pt100 Class A 2.8mm 25mm 70646149 611-7817 Dual element: Pt100 (x2) Class A 1.5mm 15mm 70643873 397-1595 D L 10mm