Specifications for Concrete Embedment Liner

Similar documents
SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

GRI - GM13 Standard Specification*

6.5 oz/yd g/m 2. 35/35 lb f min. 155/155 N min. 1.5% max. each direction Adhesion - Heat Sealed Seam ASTM D751, Dielectric Weld

GRI Standard GS-15* Test Methods, Test Properties and Testing Frequency for Geocells Made From High Density Polyethylene (HDPE) Strips

DISTRICT OF SUMMERLAND APPENDIX 7 UNIT PRICE APPENDIX 7 UNIT PRICE FOR IMPORTED MATERIALS CONTRACT 2018

Smooth Liner THE MATERIAL OF CHOICE FOR CONTAINMENT APPLICATIONS

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI. GRI Standard GM19a*

QUALITY CONTROL PROGRAM OUTLINE

Specifications for SWC #110: Pipe, Pipe Liner, & Liner Installation

AGRU Specialized Geomembranes COEXTRUDED BLACK/WHITE AND CONDUCTIVE GEOMEMBRANE LINERS

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SPECIFICATIONS FOR DRAINTUBE DRAINAGE GEOCOMPOSITES

GEOMEMBRANE INSTALLATION GUIDELINES RUFCO 20, 30 & 40 MIL UNREINFORCED DURA SKRIM 30, 36 & 45 MIL REINFORCED

SECTION 8130 XR-3-PW FABRIC BAFFLE WALL SPECIFICATION

GRI - GM17 Standard Specification*

GRI Test Method GM19* Seam Strength and Related Properties of Thermally Bonded Polyolefin Geomembranes

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

DIVISION 2 - SITE WORK

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION POLYETHYLENE PRESSURE PIPE

SECTION (07100) - DAMPPROOFING AND WATERPROOFING

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

GEOMEMBRANE PRODUCTS MANUFACTURING QUALITY ASSURANCE manual

Section Pre-Applied Sheet Membrane Waterproofing

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI. GRI Test Method GM21

CORROSION ENGINEERING SPECIFICATION FOR INSTALLATION

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

B. Seaming shall be a continuous process with a minimum of interruption along any given seam.

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SPECIFICATION for ISCO HDPE DUAL CONTAINMENT PIPE

SECTION POLYETHYLENE TAPE WRAPPING FOR PIPE

SECTION UTILITY POLYETHYLENE CONTAINMENT PIPE SYSTEMS

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec

Independent certification of your products & services. 2.2 Relevant Standards 1. SCOPE

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

SECTION FLUID-APPLIED WATERPROOFING

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

INSTALL WITH CONFIDENCE. Liners & Covers.

GRI GM30* Test Methods, Test Properties and Testing Frequency for Coated Tape Polyethylene (cpe) Barriers

Structural. Lubron. Self-Lubricating PTFE Resin Slide Bearings. Lubron Bearing Systems. Bearings to move the world.

Student Services & Classroom Addition

SEWER FORCE MAIN HDPE PIPE

CORROSION ENGINEERING SPECIFICATION FOR INSTALLATION

Reinforced Soil Slopes (RSS)

Test Charges (Rs.) per Sample GEOTEXTILES

Corrstop Dual Laminate Equipment. Corrstop. R CS Dual Laminate Equipment

2018 Intertape Polymer Group GEOSYNTHETIC RAIN COVER INSTALLATION GUIDE

SAMPLE SPECIFICATION for HIGH DENSITY POLYETHYLENE PIPING LEACHATE COLLECTION SYSTEMS

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

TESTING APPLICATION STANDARD (TAS) STANDARD REQUIREMENTS FOR THERMOPLASTIC OLEFIN ELASTOMER BASED SHEET USED IN SINGLE-PLY ROOF MEMBRANE

Geosynthetic Research Institute. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GRI Test Method GM13*

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Secudrain WD The NAUE Geosynthetic Drainage System Installation Recommendations

SECTION ORNAMENTAL ALUMINUM FENCING

A. ASTM F Standard Specification for Pressure-rated Polypropylene (PP) Piping Systems.

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

HERCULITE REPLACEABLE CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE

SECTION G SPECIFICATIONS. Table of Contents

HDPE Conduit Specification 2011

SPECIFICATIONS - DETAILED PROVISIONS Section Pond Lining - Clay and Flexible Membrane C O N T E N T S

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION CONCRETE REINFORCEMENT

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Product Information. Polyester Felt Cured-In-Place Pipe (CIPP) Lining Tube

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI GRI - GM22

SECTION MANUFACTURED ROOF EXPANSION JOINTS

@Copyright 2016 SKAPS Industries.

SECTION EXPANSION CONTROL

SECTION ORNAMENTAL WELDED STEEL FENCING

SECTION PRE-ENGINEERED BUILDING INSULATION

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

SECTION 027 SPECIFICATIONS - PIPE MATERIALS FOR SEWERS

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Specifications. Chapter 13. Specifications (800) CULVERT 96

SECTION STRUCTURAL REINFORCED POLYMER COMPOSITE PEDESTRIAN BRIDGE DECK

THERMOFIT SCL TUBING Polyolefin, Selectively Crosslinked, Semirigid, Heat Shrinkable

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

UNISTRUT CORPORATION GENERAL NOTES 1. THIS UNISTRUT SUPPORT SYSTEM IS DESIGNED TO SUPPORT A MAXIMUM UNIFORM LOAD OF PSF.

Sure-Grip System. A System with Benefits. Concrete Protection

EFFISUS EASYREPAIR MEMBRANE

GEOSYNTHETICS AND WELDED GAS RESISTANT MEMBRANE INSTALLATION QUALITY PLAN

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL

STANDARDIZATION IN GEOTECH SECTOR V.K.PATIL

Technical Information: Standard Inverted and Pull-In CIPP

DUO-THERM 505 Specification Guide

MPG Series 2250T Thermally Broken Aluminum Window

For domestic water and chilled water applications Texas A&M University requires minimum of SDR11 and meeting the following minimum specifications:

SECTION SUBDRAINAGE

TECHNICAL SPECIFICATION FOR CURED-IN-PLACE MANHOLE REHABILITATION LINER SYSTEM

Thermoplastic Lined Tunnels

SECTION EXPANSION CONTROL

Technical Specification

Transcription:

Specifications for Concrete Embedment Liner Part 1: GENERAL 1.01 SECTION INCLUDES A. Specifications and guidelines for MANUFACTURING high-density polyethylene embedment liners. 1.02 REFERENCES A. American Society for Testing and Materials (ASTM) 1. D 1505 Test Method for Density of Plastics by the Density-Gradient Technique. 2. D 1603 Test Method for Carbon Black in Olefin Plastics 3. D 5199 Standard Test Method for Measuring Nominal Thickness of Geotextiles and Geomembrane. 4. D 5596 Standard Test Method for Microscopic Evaluation of the Dispersion of Carbon Black in Polyolefin Geosynthetics. 5. D 6693 Standard Test Method for Determining Tensile Properties of Nonreinforced Polyethylene and Nonreinforced Flexible Polypropylene Geomembranes. 6. D 1204 Standard Test Method for Linear Dimensional Changes of Nongrid Thermoplastic Sheeting or film at Elevated Temperature 7. D 696 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30º C and 30º C With a Vitreous Silica Dilatometer 8. D 746 Standard test Method for Brittleness Temperature of Plastics and Elastomers by Impact 9. D 570 Standard Test Method for Water Absorption of Plastics 10. E 96 Standard Test Method for Water Vapor Transmission of Material 1.03 POST AWARD AND SUBMITTALS A. All work for and in connection with the installation of the lining, field seaming and welding joints shall be completed in strict conformity with all applicable instructions and recommendations of the liner manufacture. B. All surfaces in contact with corrosive or erosive environments or environments susceptible to mechanical damage shall be lined with an approved HDPE independent anchor embedment liner.

C. At the request of the Engineer, Pre-Caster or End User, samples, datasheets, installation instructions, etc. will be provided. D. Included with the shipment of liner, submit certified test reports that the liner and material are manufactured in accordance with standards specified herein. 1.04 QUALIFICATIONS A. The HDPE liner specified in this section shall be furnished by a Manufacture that is fully experienced, reputable and qualified in the manufacturing of the materials. The manufacture must have at least 10 years manufacturing experience. B. Locking independent anchors must be of the same material as that of the Liner, and shall be integrally extruded with the sheet in a one step process. C. Liner shall demonstrate minimum pull-out strength of 14,000 p.s.f. D. HDPE liner exposed to U.V. must be protected with 1.5-3% carbon black and comply with ASTM D1603, and D 5596. E. Liner in below grade installations, not exposed to U.V. should be light in color to facilitate camera inspections, U.V. protection is not required. 2.02 Material Properties A. The material used in the embedment liner, and in all welding strips shall be made from 97-98% virgin high density polyethylene. B. Plasticizer shall not be added to the resin formulation. C. Embedment sheet, and welding strips shall be free of holes, pinholes, bubbles, blisters, excessive contamination by foreign matter, and nicks and cuts on roll edges. D. The cap strips shall be made from HDPE, and have good impact resistance and have an elongation sufficient to bridge up to ¼ inch settling cracks. E. Cap strip shall be approximately 4 inches wide or greater, and shall be equivalent to the liner. F. Material shall maintain a repairable state through it s lifecycle by methods approved, and recommended by the manufacturer.

G. Embedment sheets shall have the following physical properties when tested in accordance with Table 1. H. Raw resin shall have the following properties when tested in accordance with Table 2. 2.03 Material Supply A. Embedment sheets shall be supplied in roll form, pre-fabricated tubes or panels. B. Cap strips shall be supplied in 4 inch widths or greater. 2.04 Material Handling A. Materials are to be handled as to prevent damage. B. The on-site storage location for geomembrane material, provided by the Contractor to protect the liner from punctures, abrasions and excessive dirt and moisture. Storage area should have the following characteristics: 1. Level (no wooden pallets 2. Smooth 3. Dry 4. Protected from theft and vandalism 2.05 Welding Procedures A. Only welding techniques approved by the manufacture are to be used. Approved welding techniques are as follows. 1. Factory butt welding. 2. Wedge welding 3. Extrusion welding 4. Electro-fusion welding. B. Hot air welding is not allowed except for the purpose of temporarily Tack welding sheets together, and will not be considered a permanent weld. C. Horizontal Pipe joints should be welded using the Electro-Fusion process as developed by GSE Lining Technology, and DemTec, whenever possible. Vertical Structures may be Extrusion Welded or Electro Fusion Welded as the contractor sees fit.

D. Welding contractors must be approved by the manufacture, and be able to demonstrate welding proficiency E. Field welded joints must be made water tight prior to the weld. Any joints leaking should be repaired using SealGuard 2 expanding foam grout or equivalent before weld is attempted. E. Proper surface preparation is required on all field welds in accordance with the Manufacture recommendations. 2.06 Weld Testing Program A. A suitable weld testing program should be instituted that meets the approval of the owner, the contractor, and the liner manufacture before start of any welding procedures. Testing methods should include both destructive and non destructive testing. B. Testing on embedded material must be non-destructive. C. Test methods may include spark testing, vacuum testing, and pull testing. D. Holidays found in welds should be ground out re-welded and tested. E. Only non destructive testing is allowed on embedded material. F. Destructive testing on weld samples should be done at the start of every shift, and consist of 1 sample welds pulled to failure using an approved potentiometer. Welds should have a minimum of 80% base material strength. G. Vacuum testing should be done on all practical field welds. H. Spark testing may be done on field welds where vacuum testing is not practical. I. Factory butt welds are exempt from testing.