Fiberstars Lighted Laminar Flow Fountains

Similar documents
ETL listed for installations within 5 ft. (1.5M) of outer edge of water

YOUR SPLASH PAD RESOURCE

BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED WATERFALLS

TYPICAL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CMP SERIES

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

1 YEAR FROM DATE OF PURCHASE

Product Manual PV1700 / PV1800 / PV2300 / PV18EXT / PV23EXT / SP1600 / SP1900 / SP2600 / SP

DIE CAST ALUMINUM & THERMOPLASTIC SUMP PUMP

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual


Single Post Anchor Part Number Spectrum Lane ~ Missoula MT ~

Installation Manual. Read the complete installation manual and Owners Manual before beginning the installation.

Gas meter clearances and service installation requirements

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION

Maelstrom. Installation and Specification Guide

Sump Pumps Office procedures for the Drainage & Grading section

SENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES

LIST OF DRAWINGS PLAN TITLE

olor Match POOL FITTINGS, INC. Blending Beauty & Function

INSTALLATION INSTRUCTION (U.S.A) FOR LUMI-O DRY NICHE INGROUND LIGHT.

Welcome: What is U-Drain? Drain Materials. Flow

Floating Headers - 4-1/8, 4-1/2, 6. with RTS88 for single or double doors. Installation instructions

INSTRUCTION MANUAL.

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual New York

If a new residence s electrical service is not located within 200 feet of existing

RESIDENTIAL FIRE SERVICE METERS Addendum #1

F500 Steeplechase Waterjump with Valve Option

MODEL SJ10. Installation Manual. SumpJet TM - Water Powered Backup System C IMPORTANT: MODEL SERIAL

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

1 PVC or ABS drain with strainer

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

METATEK POWER HOUSE CONSTRUCTION BUILDER S GUIDE CHECKLIST

OWNER S MANUAL IMPORTANT INFORMATION

Public Water Supply District #2 of St. Charles County, Missouri

GB-20. Submittal Specifications Installation Application Specific Details

Valve Nest Filter with Time Clock Control Installation and Operation Manual

PART 5 WATER SYSTEMS

INSTALLATION AND OPERATING INSTRUCTIONS

BioPrism Solid Surface

Multi-Piece Shower with Trench Drain

Section 2: Underground

Guy cable tower for WTGS. Installation guide for tower & foundation

Floor drain armatures

UNPARALLELED PERFORMANCE

Foundation Manual. Part Number: Version: Updated: July 5, S. Meadows Pkwy. A-9, #329 Reno, NV

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project.

STANDARD SPECIFICATIONS

Grizzly TM Part Number Spectrum Lane ~ Missoula MT ~

Low-Profile Multi-Piece Shower with blue, high-density polyurethane bottom

RESIDENTIAL QUICK REFERENCE

Welcome: What is U Drain? Drain Materials. Cost Comparisons

ANY SPECIFICATION DRAWINGS OR DATED PRIOR TO SEPTEMBER 2015 WILL NOT BE HONORED.

SECTION FIRE HYDRANTS

200 Series In-Slab Pool Fittings

SP-1. Owners Manual. Submersible Pump. toll free , office ,

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

VERsacourt LED Light System Installation Instructions

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Ohio

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

Please check with your local inspection authority for any additional requirements before installation.

Multicell. Vikimatic MultiCell Conduit Systems MULTICELL

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SWIMMING POOL PERMIT AND INSPECTION REQUIREMENTS

INGLEBEAMS. Our Inglebeam range is available in either solid aggregate versions or hollow light weight version.

Multi-Piece Shower with Trench Drain

Policy No As of January 12, 2016

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES

INSTALLATION INSTRUCTIONS

Installation Guide. PrivacyShield Outdoor Enclosure

Multi-Piece Shower with Trench Drain

assembly and installation guide

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

CHAPTER 12 HANDHOLES, PULLING VAULTS, AND JUNCTION BOXES

How To Construct a Ferro Cement Tank

B-500 / B-600 SERIES

INGLEBEAMS. Our Inglebeam range is available in either solid aggregate versions or hollow light weight version.

INSTALLATION MANUAL KOCH

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

B500-VRC / B600-VRC SERIES INSTRUCTIONS DETAILS RS-500-VRC INSTALLATION

I. Preconstruction Meeting and Site Preparation Date: Inspector: A. MDE Certified Installer Name

Mason s Training Programme on Onsite Treatment Systems

Variety of uses: Universal Pool Skimmer Cover, Water Main, Valves, Waterfalls & Fountains, Sewer Cleanouts MADE IN USA. Also Available in Gray & Tan

Linear Drainage ZF806 ZF812

simple, efficient, and cost effective floor and surface drainage system

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

INSTALLATION MANUAL. B-710/760 H20 SERIES MODULAR UST to AST TRANSITION SUMP

Rock Sock (RS) Rock Sock height.

SECTION FIRE HYDRANTS

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

ROOF MOUNT KIT OWNERS MANUAL

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

By Jerry Turrentine, NRCS Biologist USDA Natural Resources Conservation Service

Aegis Heavy Capacity 20K Floor Scale. MODEL: 6200 Series. Installation Manual

Transcription:

Fiberstars Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Lighted Laminar Flow Fountain. The maximum lighted distance of the laminar stream should be considered approximately 8ft height and 8ft in distance. If the laminar arc is over 8ft there is a high degree of probability that the lighting will not travel the full distance to the bottom of the laminar flow. Also, if the throw distance is over 8ft, the lighting will also fail to go the full distance of the laminar stream. IMPORTANT GENERAL SPECIFICATIONS: 1. The water supply to the laminar fountains should be filtered with a cartridge filter. Sand filter and DE filters will likely produce small particles of debris that will clog the filter screens internal to the laminar flow fountains. 2. Water supply is dependent upon 3 important factors: a. Pump size if dedicated pump is used it must be a minimum of a ½ hp and supply proper flow rate at 16 ft of head. b. Plumbing pipe size c. Number of laminar flow fountains on system NOTE: GENERAL RULE OF THUMB IS THAT EACH LAMINAR REQUIRES A MINIMUM OF 10 GPM. SEE FOLLOWING SECTION ON DESIGN CRITERIA THE LAMINAR FLOW DECK BOX IS MADE OF ABS MATERIAL. USE ONLY ABS-PVC GLUE WHEN MAKING ANY PLUMBING CONNECTIONS TO THIS DECK BOX 3. Each Fiberstars Lighted Laminar flow fountain contains 150 strands of fiber. Minimum sized conduit is 1. Always use sweep 90 s to allow the fiber to be pulled easily through the conduit. 4. Fiberstars Lighted Laminar Flow Fountains can be place in most any location from concrete decks, raised bond beams or even soft scapes. Be sure that the distance from the interior pool wall to the laminar flow fountain is no further than 5 feet. This would allow the lighted laminar flow stream to be approximately 3 feet into the pool interior. 1

5. Each fountain requires a 1 ½ PVC water supply that is reduced to ¾ to connect to the bottom of the deck box. 6. On main water supply line install a check valve and system bypass valve. Adjust bypass valve until desired flow is achieved to Laminar Fountain. INSTALLATION OF THE LAMINAR FLOW DECK BOX 1. Reconfirm that fountain is no further than 5 feet away from water surface interior. 2. Prepare location by digging hole 2 feet in diameter and depth. A. For in deck applications Level the lid to the finished grade level of decking. B. For planter areas Laminar lid should be 2 inches ABOVE the landscape area to prevent materials from intruding or washing into the fountain itself. 3. Remove the laminar flow fountain from the deck box assembly by undoing the S.S. clamp on the ½ flex hose at the bottom of the fountain. 4. Insert included plug into ½ flex pipe. Secure with S.S. clamp for pressure testing. 5. Place the deck box into the excavated hole with the internal water connection pointing in the direction of the desired water flow (towards pool interior). 6. The bottom of the deck box can be supported by utilizing the two 1 PVC support connection. The support pipe should be approximately 6 in length. You may also wire tie the deck box to any decking rebar using the 4 rebar support wings to help maintain the proper level. 7. Attach the ¾ PVC supply line to the inlet fitting. 8. Install ¾ PVC pipe for fiberoptic cable run. It is highly suggested that you install all fiber conduits with sweep fittings for easy of installation. 9. Install 1 PVC pipe for drainage. IT IS IMPERATIVE THAT ALL LAMINAR FLOW FOUNTAINS HAVE PROPER DRAINAGE. 2

10. Fill excavated area with gravel until gravel reaches approximately 1 up on bottom of deck box. 11. Finish your deck material installation making sure that the Lighted Laminar Flow fountains remain level. Utilizing the Adjustable Deck Flange adjust to match your deck height. After deck box has been installed and system has been pressure tested, the laminar flow fountain itself may be reinstalled. IT IS EXTREMELY IMPORTANT THAT THE WATER SUPPLY TO EACH LAMINAR IS ALLOWED TO BE FLUSHED SO THAT ALL MATERIAL THAT MIGHT BE IN THE LINES ARE BLOWN FREE PRIOR TO BE REINSTALLED INTO THE LAMINAR FLOW ITSELF. ADJUSTING WATER FLOW The water flow is determined by two factors: GPM water flow and angle of laminar. Set angle of your laminar flow by using the two adjustment knobs on the inside the deck box on either side of the laminar. Adjust your distance by opening or closing each respective gate valve until the desired distance is achieved. MAXIMUM HEIGHT AND DISTANCE IS APPROXIMATELY 8 FEET. Initial start up should be done gradually, allowing each laminar to fill with water slowly and allowing air to escape. Failure to do so may cause damage to unit and plumbing. DO NOT EXCEED 20 GPM PER LAMINAR OR DAMAGE CAN BE DONE INTERNALLY. IMPORTANT NOTES AND REMINDERS Always leave 2 feet of fiber on the inside of each laminar flow deck box for servicing. Max fiber runs are 5 feet off fiber distance. This is caused by plumbing fitting, etc. 20 feet = 15 feet maximum distance 40 feet = 35 feet maximum distance Fill conduit connection inside of the deck box with silicone or similar material to prevent water from entering fiber area. 3

Minimize the number of plumbing fittings in the water run to cut down flow restrictions and water turbulence. When using multiple laminar flow fountains it is extremely important that the fiberoptic cables are the same length, regardless if they are different distances from the illuminator. Example: If you have 1 laminar at 20ft and another at 40ft, both should have 40ft of fiber. Laminar flow fountains are susceptible to wind conditions and the higher the angle of your fountain the more they may be effected. If your area has regular amounts of high winds you may consider moving the laminars closer to the pool edge and decreasing the angle of the fountain. For adjustment of Fiberstars Light Enhancement Device (Scratcher) please see attached direction sheet. FOR WINTERIZATION, THE LAMINAR FLOW FOUNTAIN CAN BE REMOVED BY DISCONNECTING THE FIBER AT THE BOTTOM BY LOOSNING THE CONNECTION AND BY UNSCREWING THE 2 QUICK DISCONNECTS FOR WATE SUPPLY. If internal screens of the Lighted Laminar Flow become obstructed this will effect the laminar stream. To correct this, please remove laminar fountain from the deck box assembly and apply water pressure at the laminar fountain exit point. This will back flush the laminar and allow debris to be exited from the bottom. After back flushing of the reinstall the laminar fountain and adjust water flow and angle for desired effect. 4

Rebar Support Wing Laminar Lid Scratchers Rebar Support Wing Adjustment Knob Laminar Adjustment Knob 150 Strand Fiber ½ Flex ¾ Fiber Connection Figure A ¾ Water Connection NOTE: Use supplied ¾ flex pipe section to glue into Laminar Body connection. 13 ½ 12 15 ¼ 1 Stand Pipe 1 Drain Figure B Figure C 5

Lighted Laminar Light Enhancement Device In order to achieve maximum light output, the Light Enhancement Device will need to be adjusted. Adjustment of the scratcher or Light Enhancement Device will increase the light output of the laminar flow stream and also will allow you to create water effects such as pulsing of the flow stream and light output. NOTE: For best effects the following should be done in a dark or nighttime environment Adjustment 1. Ensure that all connections and other installation requirements have been completed. 2. Turn on and operate system as per other directions. This will allow you to adjust the water direction and height properly along with the water flow (GPM) that you wish to achieve. 3. Once both of the above have been completed, turn off system. 4. Raise the laminar flow lid/fountain by the edge of the deck box approximately 4 inches. 5. Insert 1 2 x 4 board under each side of the lid, parallel with the slot in the lid, so that the lid is supported, yet raised up from the deck box base. 6. Turn back on the system and reestablish water flow to the fountain. 7. The scratcher has 3 adjustment screws. Adjust each screw so that the tip just touches the water flow. (See diagram below) 8. As you increase the contact area of each screw you can achieve different light effects, such as pulsing or burping of the light and water flow. 9. Once you have made the adjustments to achieve your desired effects, add a little drop of silicon or a non permanent thread locking compound on each screw. Turn off the system and remove the 2 x 4 braces and set the laminar/lid back into place on the deck box flange. 10. Turn on the system one last time as a final inspection to insure that the lighting effect you adjusted for in #7 is still there. You may have to do several adjustments to achieve the maximum lighting effect. 6

7