Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

Similar documents
FRP Anchorage Systems for Infill Masonry Structures

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

SHEAR AND BUCKLING STRENGTHENING OF STEEL BRIDGE GIRDER USING SMALL-DIAMETER CFRP STRANDS

Use of CFRP for Strengthening Steel Structures & Bridges

FRP FOR SUSTAINABLE PRECAST CONCRETE STRUCTURES

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

FATIGUE BEHAVIOR OF IMPACT DAMAGED PRESTRESSED CONCRETE BRIDGE GIRDER REPAIRED WITH CFRP SHEETS

Presentation in support of

Performance of NSM FRP strengthened concrete slabs at low temperatures

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

EFFECT OF EMBEDMENT LENGTH ON THE PERFORMANCE OF SHEAR-STRENGTHENED RC BEAMS WITH L-SHAPED CFRP PLATES

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Flexural strengthening of reinforced concrete beams using externally bonded FRP laminates prestressed with a new method

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

FRP STRENGTHENING OF 60 YEAR OLD PRE-STRESSED CONCRETE BRIDGE DECK UNITS

LOAD-BEARING PRECAST CONCRETE SANDWICH WALL PANELS WITH BASALT-FRP REINFORCEMENT AND TIES

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

2.0 REVIEW OF LITERATURE. In the last few years, the use of fiber-reinforced plastic (FRP) rebars to replace steel

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

OUT OF PLANE BEHAVIOR OF MASONRY INFILL WALLS RETROFITTED WITH A REINFORCED POLYMER GRID AND POLYUREA SYSTEM

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

FRP Shear Transfer Mechanism for Precast Prestressed Concrete Sandwich Load Bearing Panels. Sami Rizkalla, Tarek Hassan and Gregory Lucier

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

BEHAVIOR OF 40 YEAR-OLD PRESTRESSED CONCRETE BRIDGE GIRDERS STRENGTHENED WITH CFRP SUBJECTED TO CYCLIC LOADING

BEHAVIOUR OF RC BEAMS STRENGTHENED WITH NSM STEEL AND CFRP BARS

FATIGUE BEHAVIOR OF CFRP-STRENGTHENED REINFORCED CONCRETE BRIDGE GIRDERS. Abstract

STRENGTHENING OF MASONRY WITH NEAR SURFACE MOUNTED FRP BARS. Abstract

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

BEHAVIOUR OF FIBRE REINFORCED POLYMER REINFORCED CONCRETE BEAMS WITH FIBRE MESH SHEAR REINFORCEMENT

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

STATIC AND FATIGUE PERFORMANCE OF 40 YEAR OLD PRESTRESSED CONCRETE GIRDERS STRENGTHENED WITH VARIOUS CFRP SYSTEMS

USE OF ANCHORS IN SHEAR STRENGTHENING OF REINFORCED CONCRETE T-BEAMS WITH FRP

INNOVATIVE USE OF FRP FOR SUSTAINABLE PRECAST STRUCTURES

Extending the Lifespan of Structural Concrete

Determining the Bond-Dependent Coefficient of Glass Fiber- Reinforced Polymer (GFRP) Bars

Structural Performance of 8-inch NRG Concrete Masonry Units. Report Compiled for: Niagara Regional Group. Date: January 28, 2013

AFRP retrofitting of RC structures in Japan

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

RESEARCH ON SEISMIC RETROFIT OF EARTHQUAKE-DAMAGED AND SEISMIC-DEFICIENT STRUCTURES USING FIBRE-REINFORCED POLYMER (FRP) TECHNOLOGY

Nafadi, Khalaf Alla, Lucier, Rizkalla, Zia and Klein BEHAVIOR AND DESIGN OF DIRECTLY LOADED LEDGES OF SHORT SPAN L- SHAPED BEAMS

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

BEHAVIOR OF FRP SANDWICH PANELS FOR TRANSPORTATION INFRASTRUCTURE

A STUDY ON THE BEHAVIOUR OF RC BEAMS RETROFITTED USING CFRP LAMINATES UNDER SINGLE POINT LOADING

EFFECTS OF SUSTAINED LOAD AND FREEZE-THAW EXPOSURE ON RC BEAMS STRENGTHENED WITH PRESTRESSED NSM-CFRP STRIPS

LATEST ACHIEVEMENT IN TECHNOLOGY AND RESEARCH OF RETROFITTING CONCRETE STRUCTURES

Repair and Strengthening of Highway Bridges with FRP

INNOVATIVE HYBRID WEARING SURFACES FOR FRP BRIDGE DECKS

PRE-CONSTRUCTION INVESTIGATION FOR THE REHABILITATION OF A BRIDGE USING INTERNAL FRP TECHNOLOGIES

Fatigue and Overloading Behavior of Steel Concrete Composite Flexural Members Strengthened with High Modulus CFRP Materials

Strengthening Highway Bridges with CFRP Composites

Carbon Fibre Textile

Retrofitting methods

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Debonding Behavior of Skew FRP-Bonded Concrete Joints

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Basic types of bridge decks

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Fiber Reinforced Polymer Composites for Infrastructure Strengthening - From Research to Practice

Strengthening of infilled RC frames by CFRP

Moment curvature analysis of concrete flexural members confined with CFRP grids

SEISMIC STRENGTHENING OF INFILLED RC FRAMES BY CFRP

Use of Externally Bonded FRP Systems for Rehabilitation of Bridges in Western Canada

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Chapter 2 Notation and Terminology

RESILIENT INFRASTRUCTURE June 1 4, 2016

Seismic Behavior of Shear-Critical Reinforced Concrete Frame: Experimental Investigation

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

Application of Tensioned CFRP Strip Method to an Existing Bridge

Characterization of Physical Properties of Roadware Clear Repair Product

Flexural behavior of aged prestressed concrete girders strengthened with various FRP systems

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

Seismic Behavior of Concrete Columns Confined with Steel and Fiber-Reinforced Polymers

FRP-confined concrete-encased cross-shaped steel columns: stub column tests

Function-integrated GFRP sandwich roof structure Experimental validation of design

The Effect of Width, Multiple Layers and Strength of FRP Sheets on Strength and Ductility of Strengthened Reinforced Concrete Beams in Flexure

STRENGTHENING OF MASONRY BEAM WITH ECC AS BED JOINT

Flexural Behaviour of Composite Girders Using FRP and Precast Ultra-High-Strength Fiber-Reinforced Concrete Slabs

Prestressing Concrete with CFRP Composites for Sustainability and Corrosion-Free Applications

PASSIVE AND ACTIVE NEAR-SURFACE MOUNTED FRP RODS FOR FLEXURAL STRENGTHENING OF RC BEAMS. Abstract

Parametric Analysis on the Optimal Dimensions of Steel Sleeve in Swaging Type Anchorage for CFRP Tendon

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips


Seliem, Lucier, Rizkalla, and Zia BEHAVIOR OF CONCRETE BRIDGE DECKS REINFORCED WITH HIGH- STRENGTH STEEL

An Experimental Investigation on Flange Bonded Retrofitting of RC Beam-Column Joints using CFRP

STRUCTURAL STRENGTHENING WITH FRP AYDIN KHAJEPUR SIKA PARSIAN, TM REFURBISHMENT

BEHAVIOR OF BRIDGE DECKS REINFORCED WITH MMFX STEEL

Static Behavior of 40 Year-Old Prestressed Concrete Bridge Girders Strengthened with Various FRP Systems

PULLOUT CAPACITY BEHAVIOUR OF FRP-HEADED REBARS

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

International Journal of Advance Research in Engineering, Science & Technology

Transcription:

Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

AltusGroup, Inc. Freyssinet, Inc. Fyfe Company, LLC Grancrete, Inc. Martin Marietta Composites Nippon Steel Materials Co., Ltd. 2

Korea Institute of Construction Technology (KICT) Millikan & Company KPFF, Inc. 3

NCSU-1. Rapid FRP Repair of Damaged Reinforced Concrete Columns NCSU-2. 3-D FRP Sandwich Panels with Corrugated Sheets for Bridge Decks NCSU-3. Innovative Bonding and Fibers for Strengthening Concrete Structures NCSU-4. Innovative FRP Shear Transfer Mechanism for Precast Prestressed Concrete Sandwich Panels NCSU-5. FRP Anchorage Systems for Strengthening Infill Masonry Structures (Please complete LIFE forms for these projects) 4

PI: Dr. Rudi Seracino Industrial Collaborator: Fyfe Company, LLC Student: Amy Byrum (Hao Hu & Ty Rutledge) Overview: Develop rapid FRP repair techniques for damaged RC columns with buckled and/or ruptured longitudinal reinforcing steel. Budget: $25,000 5

Motivation Rapidly restore lost strength and ductility of damaged RC columns Currently, FRP repair not permitted when longitudinal bars are not straight Research Plan Phase I Confined Cylinder Tests Phase II Full-Scale Column Repair 6

Phase I Cylinder Tests with 3 parameters 1. FRP Material 2. Core Material 3. Adhesive Direct axial compression in order to determine confined stress-strain properties 7

Phase I - Repair System Design Types of FRP Carbon Fiber Reinforcing Fabric Unidirectional Open Weave Basalt Fabric 0/90 bidirectional 8

Phase I - Repair System Design Core Material PC Concrete 5000 psi Rapid Curing Cementitious Patching Material 4500 psi Initial set in 3-5 minutes Adhesive Regular Epoxy 7 day full cure Rapid Cure Epoxy 48 minute gel time Cementitious Bonding Matrix 50 min workability time Interlocks fibers 9

Phase I - Repair System Design Material Tests Tensile Properties of Composites and Epoxies (ASTM D3039 and ASTM D638) Tensile Properties of Basalt Cementitious Alternative and Dry Fibers 10

Phase I - Test Matrix Core Material Control (No Wrap) CFRP & 7- day Epoxy CFRP & Rapid Cure Epoxy Basalt & Bonding Matrix PC Concrete Rapid Patch Material 3 3 1 layer 3 layers 1 layer 3 layers 1 layer 3 layers 1 layer 3 layers 1 layer 3 layers 1 layer 3 layers 11

Phase I Continuous Strain Field Measurement Particle Image Velocimetry (PIV) Benefits Speckle Pattern 12

Phase I Phase 2 Compare data with existing confinement models Use proposed model to optimize design for wrapping damaged columns 13

Future Work - Phase II (Column Repair) Moderately Damaged Buckled reinforcing bars Remove loose concrete Replace damaged concrete Apply repair system design Severely Damaged Ruptured reinforcing bars Remove loose concrete Add longitudinal reinforcement in concrete cover Replace damaged concrete Apply repair system design 14

15

PI: Dr. Sami Rizkalla Industrial Collaborator: Martin Marietta Composites Graduate Student: Gautam Sopal Objective: To Study the behavior of new 3-D GFRP sandwich panels with corrugated sheets under various loading conditions Budget: $50,000 16

Through fibers Top GFRP plies Bottom GFRP plies 3-D GFRP Sandwich Panel with corrugated sheets Additional corrugated sheets Centre Line 17

Direct Shear behavior Configuration Specimen Shear Modulus (psi) Transverse Steel plates Longitudinal Applied Load Ultimate Strength (psi) 1T 17754 242 2T 17728 Additional 251 3T 22664 steel strip 249 Average 19400 247 1L 18664 203 2L 19460 193 3L 16009 195 Average 18000 200 Linear potentiometer 18 Typical test setup for ASTM 273 in transverse direction

Direct Shear behavior

Applied Load, Kips Applied Load, Kips One way flexural behavior Span 36 in Load vs Displacement Applied load through 220 kips actuator Load vs Displacement Failed due to localize crushing of top GFRP plies Span 48 in Span 60 in Foam cracking and through fibers crushing Span 60 in Simple Support conditions Non-linear Behavior Avg. Midspan Displacement, in Support Displacement potentiometer Midspan Displacement potentiometer Avg. Midspan Displacement, in 20 Typical test setup evaluating one way flexural behavior

Applied Load, Kips Two way flexural behavior Load vs Displacement Failed due to localize crushing of top GFRP plies Foam cracking and through fibers crushing Typical test setup evaluating two way flexural behavior Avg. Midspan Displacement, in 21

Applied Load, Kips Shear behavior Load vs Displacement Direct Shear results Configuration Avg. Ultimate Shear stress (psi) Transverse 247 Longitudinal 200 Failed due to localize crushing of top GFRP plies Foam cracking and through fibers crushing Where, V= Experimental shear force = 43.5 Kips Q = 1 st moment of inertia = 2.1 in 3 I = Moment of inertia = 10.1 in 4 Typical b = width test setup of the evaluating section = 46 shear in behavior 22 = 196.6 psi Shear Span 12 in Avg. Midspan Displacement, in

Failure Modes Localize crushing Shear cracks Shear cracks Debonding between bottom plies and core corrugation Direct shear behavior One way and two way flexure behavior Shear behavior Bottom plies undamaged 23

Future experiments Direct One way compression fatigue behavior behavior Steel Plate Loading Plate Support Specimen 72 in x 18 in Steel Plate Specifications Applied No. Load of specimens - 2 No. of cycles 2 million Frequency 2 Hz Load range 6 to 10 kips Cut specimen 24 Load cell Typical test setup for one way fatigue behavior Typical test setup for direct compression study

Preliminary conclusions Panels failed under required failure modes Increased shear strength and shear modulus Perfectly linear and elastic behavior towards failure Localize crushing of top GFRP plies Bottom GFRP plies remained undamaged 25

Future study Quantify the effect of core corrugation Compare the fundamental characteristics Determine the possible degradation under cyclic loading Calibrate specific analysis approach Develop simple design guidelines 26

27

PI: Dr. Sami Rizkalla Industrial Collaborators : Grancrete, Inc., Nippon Steel Materials Co., Ltd., Fyfe Company, LLC, Freyssinet, Inc. Graduate Students: Adolfo Obregon-Salinas, Benjamin Mielke, Brian Mielke Objective: Investigate the effectiveness of various fiber strengthening systems using different adhesive materials. Budget: $125,000 28

Repair and Strengthening of Concrete Structures Using Grancrete/FRP System Parameters Application Method Type of Fiber Adhesive Material Fiber Reinforcement Ratio 29

Test Matrix 30 Cast Type of Fiber Adhesive Material 1 2 3 Layers of Fiber Application Method Specimen ID NONE NONE NONE NONE Control 1 Glass Fibers (small ¼ grid) Basalt Grid Cast GS-G-1-C Grancrete PCW Paste 1 Layer Sprayed GS-G-1-S Epoxy Cast GS-E-1-C Grancrete PCW Paste Cast B-G-1-C 1 Layer Sprayed B-G-1-S Epoxy Cast B-E-1-C Grancrete PCW Paste 2 Layers Cast B-G-2-C NONE NONE NONE NONE Control 2 Glass Fibers (Large 1 grid) C-Grid Carbon Strand Sheet Grancrete PCW Paste Cast GL-G-1-C 1 Layer Epoxy Cast GL-E-1-C Grancrete PCW Paste Cast CG-G-1-C 1 Layer Epoxy Cast CG-E-1-C Grancrete PCW Paste Cast CS-G-1-C 1 Layer Epoxy Cast CS-E-1-C Grancrete PCW Paste 2 Layers Cast CS-G-2-C NONE NONE NONE NONE Control 3 Basalt Grid Carbon Strand Sheet 1 Layer Cast B-G-1-C Grancrete PCW Paste 2 Layers Cast B-G-2-C Epoxy 2 Layers Cast B-E-2-C 1 Layer Cast CS-G-1-C Grancrete PCW Paste 2 Layers Cast CS-G-2-C Epoxy 2 Layers Cast CS-E-2-C C-Grid Grancrete PCW Paste 2 Layers Cast CG-G-2-C Total number of slabs 24 I Application Method III Bonding Material Cast Sprayed IV Fiber Reinforcement II Type of Fibers Ratio Grancrete PCW paste ¼ Glass Grid vs Single Layer Basalt C-Grid Double Layer Carbon Strands 1 Glass Grid Epoxy vs

Test Results SLAB ID CRACKING YIELD MAX LOAD DEFLECTION AT DUCTILITY FAILURE Load (kips) Deflection (in) Load (kips) Deflection (in) (kips) 85% MAX LOAD (in) MODE CAST #1 Control - 1 2.51 0.06 11.90 0.94 13.49 4.85* 5.18* Concrete Crushing GS-G-1-C 4.40 0.13 13.24 0.97 15.54 4.50 4.62 Fiber Rupture GS-G-1-S 3.92 0.09 13.51 0.99 16.23 6.46 6.55 Fiber Rupture GS-E-1-C 4.61 0.12 15.30 1.02 17.96 3.41 3.33 Fiber Rupture B-G-1-C 4.62 0.10 13.35 0.88 16.09 6.98 7.92 Concrete Crushing B-G-1-S 3.42 0.07 13.01 0.93 14.76 6.02* 6.44* Concrete Crushing B-E-1-C 4.30 0.09 14.70 0.91 16.22 3.91 4.32 Fiber Rupture B-G-2-C 4.43 0.07 13.53 0.81 15.74 6.07 7.53 Concrete Crushing CAST #2 Control - 2 2.20 0.07 12.30 1.12 12.66 5.46 4.89 Concrete Crushing GL-G-1-C 3.00 0.12 12.30 1.15 14.02 3.78 3.30 Fiber Rupture GL-E-1-C 2.61 0.08 14.51 1.20 14.88 2.35 1.97 Fiber Rupture CG-G-1-C 2.40 0.06 13.81 1.17 15.00 2.62 2.24 Fiber Rupture CG-E-1-C 2.81 0.10 14.41 1.26 14.99 2.40 1.91 Fiber Rupture CS-G-1-C 3.30 0.09 16.30 1.34 18.68 2.30 1.72 Fiber Rupture CS-E-1-C 3.40 0.08 18.20 1.36 19.69 1.82 1.34 Fiber Rupture CS-G-2-C 5.10 0.11 20.80 1.22 23.21 1.93 1.58 Concrete Crushing CAST #3 Control - 3 2.50 0.05 12.30 1.05 13.10 5.26 5.03 Concrete Crushing B-G-1-C 3.11 0.06 12.71 1.02 13.33 6.65 6.54 Concrete Crushing B-G-2-C 3.10 0.07 12.90 1.07 14.97 4.12 3.85 Concrete Crushing B-E-2-C 3.40 0.10 15.40 1.20 17.29 3.07 2.55 Fiber Rupture CS-G-1-C 4.21 0.09 17.45 1.23 21.11 2.30 1.88 Fiber Rupture CS-G-2-C 5.01 0.11 21.31 1.36 26.12 2.63 1.93 Concrete Crushing CS-E-2-C 4.30 0.11 23.61 1.39 27.21 2.05 1.47 Fiber Rupture CG-G-2-C 3.91 0.09 15.30 1.15 18.28 3.25 2.82 Fiber Rupture * Test stopped before reching 85% of maximum load. Maximum recorded deflection used instead. 31

MEASURED / CONTROL MEASURED / CONTROL Typical Test Results 2.50 2.50 2.00 2.00 1.50 1.50 1.00 0.50 Max Load Yield Load Crack Load 1.00 0.50 0.00 0.00 Load at different stages Ductility Data dimensionalized with respect to the control specimen 32

Test Results Relative % Increase in Max Load Per Fiber Area Glass Grid (1/4 spacing) Basalt Grid Glass Grid (1 spacing) C-Grid Carbon Strands 33

Effects Method of Application No major differences observed Both methods adequate for FRP application Spray Positive moment regions Cast Negative moment regions 34

Effects Type of Fibers All fibers increased load capacity Basalt quality control Fibers with high tensile strength and modulus increase load capacity and decrease ductility Fiber grids with small spacing may cause localized debonding Carbon Strand Carbon-Grid 0.25 Glass Grid 1 Glass Grid Basalt Grid 35

Effects Bonding Material Epoxy had slightly higher load capacity Epoxy caused fibers to rupture at a single crack Grancrete had slightly higher deflection and ductility Grancrete forms well distributed flexural cracks Grancrete Epoxy 36

Effects Fiber Reinforcement Ratio Higher reinforcement ratio increases flexural capacity Higher reinforcement ratio reduces ductility 1 Layer Carbon Strands 2 Layers Carbon Strands 37

Work In Progress I. Advanced Fiber Strengthening Systems for Concrete Structures Applied Load P P 38

Materials to be Investigated Fibers Carbon Strand Carbon Grid Glass Grid Adhesive Epoxy Cementious Bonding Matrix Grancrete Carbon Strand 0.25 Glass Grid 1 Glass Grid Carbon-Grid 39

Test Matrix Specimen ID Fiber Details Adhesive Application Reinforcement Ratio No. of Specimens CONTROL NONE NONE NONE NONE 2 HT-E-E HT -G-E-1 High Tensile Epoxy Externally Bonded (EB) 1.64 mm 1 EB 1.64 mm 1 HT -G-E-3 Carbon Strand EB 3.28 mm 1 Grancrete HT -G-E-4 EB 4.92 mm 1 HT -G-NSM NSM ----------------- 1 HM-E-E Epoxy EB 1.64 mm 1 HM-G-E-1 EB 1.64 mm 1 High Modulus HM-G-E-3 EB 3.28 mm 1 Carbon Strand Grancrete HM-G-E-4 EB 4.92 mm 1 HM-G-NSM NSM ----------------- 1 C-E-E Carbon Grid Epoxy EB 19 mm Grid 1 C-G-E Grancrete EB 19 mm Grid 1 C-C-E Cementious Bonding Matrix EB 19 mm Grid 2 G-G-0.25 Grancrete EB 0.25 inch Grid 1 Glass Grid G-G-0.5 Grancrete EB 1.0 inch Grid 1 Total Number of Slab Specimens 18 IV III Reinforcement Type Application of Fiber II Bonding Ratio Method Material Glass 1.64 Grid mm 3.28 mm Carbon EB Epoxy 4.92 mm Grid Grancrete 19 mm Carbon Grid Strands Cementious Bonding 0.25 and Matrix 1.0 Grid NSM 40

Reinforcement Ratio for Carbon Strands Type 1 Type 2 Type 3 Type 4 41

Different Application Techniques Cut grooves for FRP strengthening Elevation View Plan View Externally Bonded (EB) Near Surface Mounted (NSM) 42

Work in Progress II. CFRP Strengthening System for Reinforced Concrete Structures 43

Motivation Experimental study of innovative CFRP sheet strengthening system for RC structures Phase I - Physical and Mechanical Properties and Aging Tensile Properties Creep (Tensile) Glass transition temperature Void Content Coefficient of Thermal Expansion Interlaminar Shear Strength Phase II - Large Specimen Testing RC beams in flexure and shear RC slabs in flexure RC columns in axial compression 44

Physical and Mechanical Properties and Aging Witness Panels Coupon Specimens Testing Tensile Properties 45

Large Specimen Testing (c) Column 46

Test Matrix Beams and Slabs 47

Test Matrix Columns 48

49

PI: Dr. Sami Rizkalla Industrial Collaborator: AltusGroup, Inc. Graduate Students: Greg Bunn Overview : Investigate the fundamental properties of a unique CFRP shear transfer mechanism. Budget : $50,000 50

Precast, reinforced, and prestressed concrete sandwich panels have been produced for over 50 years. Panels are typically load bearing and provide insulating value. 51

Provides up to 100% composite action by transferring all forces across the insulation that separates the two wythes of concrete through truss action. Creates a more thermally efficient building envelope. 52

Expanded Polystyrene Insulation (EPS) Closed-cell Insulation Manufactured by expanding a polystyrene polymer Extruded Polystyrene Insulation (XPS) Rigid Insulation Manufactured using and extrusion process of polystyrene polymer 53

Dual Reaction Frames 150 Kip Load Cell Two - 60 ton Hydraulic Jacks Linear Pots 54 Outer Wythes Supported

Insulation Type EPS XPS Insulation Thickness EPS XPS 2" 2" 4" 4" 6" 8" Panel Width 24" 36" 48" 72" CGRID Spacing 12" 18" 24" 36" Insulation Concrete Interface Bonded - Typical Practice Debonded - Plastic Sheets Breaking Bond CGRID Continuity No Gap 6" Gap CGRID Orientation Vertical Transverse 55

Load (lbs.) 120000 48EPS.24.2.A Load vs Displacement - 8 Sensors 100000 80000 60000 40000 20000 LP1 LP2 LP3 LP4 LP5 LP6 LP7 LP8 0 0.00 0.20 0.40 0.60 0.80 1.00 Displacement (inches) 56

Load (lb) 120000 36" Panel w/ 18" CGRID Spacing 110000 100000 90000 36EPS.18.2.A 80000 36EPS.18.2.B 70000 60000 50000 40000 30000 36XPS.18.2.A EPS Insulation Shear Flow = 303-400 lb/in Shear Stress = 15.5-20.5 psi 57 20000 10000 0 36XPS.18.2.B 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 Average Deflection (in) XPS Insulation Shear Flow = 177-228 lb/in Shear Stress = 9.0-11.6 psi

Load (lb) 120000 72" Panel w/ 36" CGRID Spacing - 4" Insulation 110000 100000 90000 80000 70000 72EPS.36.4.A 72EPS.36.4.B EPS Insulation Shear Flow = 283-402 lb/in Shear Stress = 7.9-11.2 psi XPS Insulation Shear Flow = 142-184 lb/in Shear Stress = 4.0-5.1 psi 60000 72XPS.36.4.A 50000 40000 30000 20000 72XPS.36.4.B 10000 58 0 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 Average Deflection (in)

Load (lb) Transverse Panels 120000 110000 100000 90000 80000 70000 60000 50000 48EPS.36.2.TRANS.A 48EPS.36.2.TRANS.B Transverse XPS Panels Avg. Shear Flow = 133-141 lb/in Avg. Shear Stress = 3.7-3.9 psi Transverse EPS Panels Avg. Shear Flow = 334-355 lb/in Avg. Shear Stress = 9.3-9.85 psi 40000 30000 20000 48XPS.36.2.TRANS.B 10000 48XPS.36.2.TRANS.A 59 0 0.00 0.20 0.40 0.60 0.80 1.00 1.20 Average Deflection (in) Scale changed from 0.8 1.25 in.

Typ. Buckling of Cords in Compression Typ. Rupturing of Cords in Tension 60

Observed Pull-Out of CGRID in Some Cases Typ. Rupturing of Cords in Tension 61

T T 62

Load (lb) 8000 2" EPS vs XPS - Tension Specimens 7000 6000 5000 2" EPS EPS Max Strength = 391.6 lb/in XPS Max Strength = 183.8 lb/in 4000 3000 2000 2" XPS 1000 63 0 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 Average Deflection (in)

64 P

Deflection (mm) 7 Creep - XPS vs EPS 45% Max Load 6 EPS 5 4 3 2 XPS 1 65 0 0 10 20 30 40 50 60 70 80 Time (days)

EPS insulation exhibits greater shear capacity. XPS panels rely primarily on the CGRID reinforcement. Increasing the thickness of EPS tends to have a negative effect on the shear capacity. Increasing thickness of XPS seems to have minimal effect. Tension tests exhibited similar behavior. 66

Analyze test data to provide design guidelines for use of CGRID as a shear transfer mechanism in precast concrete wall panels. Investigate the effect of freeze/thaw cycling on composite action. Complete 1 year creep testing In progress. Explore the use of other FRP and insulation types in wall panels. 67

68

PI: Dr. Sami Rizkalla & Dr. Tamon Ueda Industrial Collaborators: Fyfe Company, LLC & Nippon Steel Materials Co., Ltd. Graduate Students: Dillon Lunn & Shohei Maeda Objective: Explore the performance of innovative FRP anchorage systems for strengthening of masonry infill walls Budget: $50,000 69

Motivation Flexural Shear Sliding Failure 70

71 Test Setup

FRP Anchorage Systems Control Overlap Mechanical Embedded Bar Fiber Anchor 72

FRP Anchorage Systems Shear Key Near Surface Mounted 73

Shear Embedded Control Overlap NSM Fiber CFRP Key Anchor Restraint Bar Underside Top of GFRP Mortar Joint After Failure after Failure GFRP GFRP GFRP Horizontal Pullout Crack (Right) Anchor Rupture (left) NSM CFRP w/grancrete Debonding Shear keys Embedded NSM Bar Strands FRP Rupture GFRP Top Mortar Joint after Failure PET Top Mortar Joint after Failure GFRP Top Mortar Joint after Failure PET NSM CFRP w/epoxy PET PET Underside of PET after Failure Shear keys NSM Strands Anchor Pullout 74

75 Ultimate Strength Comparison

76 Ultimate Displacement Comparison

Future Work Non-Linear Finite Element Analysis Material non-linearity Geometric non-linearity Conclusions Increase in strength of between 1.6 to 7.2 times the control Change in displacement capacity ranged between 0.6 to 4.5 times the control Mode of failure closely related to type of anchorage GFRP typically provided greater strength, while PET provided greater ductility 77

78

Move to accept the Korea Institute of Construction Technology (KICT) as a member of the NSF I/UCRC Center for Integration of Composites into Infrastructure (CICI) for the period of Feb 1, 2011 to June 30, 2013. The research project that will be undertaken is the Use of FRP for Innovative Insulated Concrete Sandwich Panels. PI: Dr. Sami Rizkalla Graduate Student: Greg Bunn 79