Direct vs Indirect. How are you measuring NO2? Do it directly, with the new Serinus 60.

Similar documents
ACOEM Group. Direct vs Indirect NO 2. Measurement. Do it directly with the new Serinus 60 gas analyser

Direct vs Indirect NO 2. Measurement. Do it directly with the new Serinus 60 gas analyser. ecotech.com

Fpollutant-free zero air for analytical

Environmental Monitoring. Solution Snapshot. ecotech.com

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

Environmental Monitoring

ASI MODEL DM 100 SERIES DILUTING MODULES

Environmental Monitoring. Solution Snapshot ECOTECH Europe. ecotech.com

Using the PPM2 Portable Trace Moisture Transmitter

Ambient Air Quality Monitoring

Certificate: / 20 August 2013

Heated FID OVF Portable THC/TVOC Analyzer

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

FOUNDRY-MASTER Pro. First class laboratory optical emission spectrometer for complete professional metal analysisoes

FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

Particulate Monitors and Samplers

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Fully Extractive Vs. Dilution Extractive CEMS

Keeping the World Flowing. Rail Industry Solutions

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

CO Sensor Response Study NO & NOx Analyzer Validation. June 6, 2018

Aurora Integrating Nephelometers. Aerosol monitoring & atmospheric research. ecotech.com

Greater efficiency through on-demand paste production

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems

TVOC Heated FID VE 7

Miniature I/P, E/P Transducer

HEROSE NEWS PRODUCTS IN THIS ISSUE: SAFETY VALVES INSTRUMENTATION VALVES 3 PIECE BALL VALVES CRYOGENIC PAPER ANCILLARIES

Title: Standard Operating Procedure for Measurement of Ozone in Ambient Air by Ultraviolet (UV) Photometry

Online Gas Analyzer / Monitor

Mark Millar. Exploring Green Logistics Green Logistics in Action Measuring Emissions Legislation on Environmental Compliance Future Directions

Controlling NOx and other Engine Emissions

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Analyzer Module Wet Chemiluminescence Detection (WCLD)

8 stream capability with dual mode (H 2 S & total Sulphur)

Lab 7 Measurement of Ozone

Petroleum Fuels. ogen process analyzers 6000 SERIES

Author: Donald Pretty, Project Manager, Presenter: John Downs, Environmental Manager, B&W PGG, KVB-Enertec Products January 29, 2015

This presentation is one of the support materials prepared for the capacity building program Building Leaders in Urban Transport Planning (LUTP).

Innovative Wellhead Tools for Landfill Gas Management

Smarter Choices, Better Air.

CHAPTER 6 : GAS SAMPLING SYSTEMS

DETOX THE AIR. APCO Family of Air Treatment Systems

Lab 6 Measurement of Ozone

DRY HYDRATED LIME INJECTION FOR COAL-FIRED BOILER FLUE GAS DESULFURIZATION (FGD) FOREWORD

Near reference sensors and their application. February 13 th, 2017 Hannamari Jaakkola, Vaisala Oyj

Mercury Monitoring in a Cement Kiln

// XPLORER-NS. Total Nitrogen and Sulfur Analyzer

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Clean Cool Energy. Harnessing the power of liquid nitrogen for zero emission power and cooling.

FORSYTH COUNTY OFFICE OF ENVIRONMENTAL ASSISTANCE AND PROTECTION

ANALYTICAL GAS GENERATORS INNOVATIVE GAS SOLUTIONS FOR YOUR LAB

HotBlock. ENVIRONMENTAL EXPRESS Call or Metals Digestions: HotBlock TM Digestion Systems

GE Measurement & Control. Moisture can t escape our innovation.

Zero emission transport refrigeration. Harnessing the power of liquid nitrogen for zero emission power and cooling.

Dublin Airport Air Quality Monitoring Q1 2017

Protecting our urban environment. Exhaust Control Industries Air and noise pollution control specialists

CANADA UNISEARCH founded in 1980

LD8000. DESIGN REPORT v2. Trace Nitrogen in Argon or Helium analyzer

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

8. PYROMETRY FUNDAMENTALS

Waterview Operational Air Quality Monitoring Report January 2018

ANALYSIS OF PARTICULATE POLLUTANT (PM 2.5 ) AND GASEOUS POLLUTANT (CO) AT JABALPUR, MP

The Energy Technologies Institute (ETI) Submission to the BERR Consultation on Renewable Energy Strategy

ONLINE TOC ANALYZER B-Series

DEVELOPMENT OF A MICRO MONITORING STATION FOR HOT SPOT NARROW STREET MEASUREMENTS

Lamproom Management 1

msp metrology software products ltd

Air Quality Modelling for Cycle Enfield. 21 st January 2016

Improving Quality Of Life And Environmental Equity In Richmond With Mobile Air Quality Sensors Combined With Census Data

Online Infrared Flue Gas Analyzer Gasboard 3000

Comparison Continuous Emission Monitoring Techniques

Engineered Solutions for Landfill Gas Well Field Management

Building a Bigger, Better Zero Air Generator Certification Process

Four Factors to Consider When Building Complex Production Systems

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

HIGH PERFORMANCE FLOW CONDITIONERS Michael P. Saunders Savant Measurement Corporation USA

ANALYTICAL GAS GENERATORS

HIGH PERFORMANCE SOLAR THERMAL SOLUTIONS

Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

AUTOMATIC PEROXYACETYL NITRATE (PAN) ANALYZER

EuroFID Total Hydrocarbon Analyzer

Air Compressor Series.

Rooftops High performance, proven reliability and easy installation

Proceedings of the 43 rd Annual ISA Analysis Division Symposium

NO INTERFERENCE BETWEEN YOU AND BETTER THROUGHPUT. NexION 1000 ICP Mass Spectrometer. For research use only. Not for use in diagnostic procedures.

On the environmental safety of automobile vehicles

testo 350. For emission testing and combustion analysis. Portable Emission Analyzer

Cllr Vic Ient s Comments to the UK Government

MRSI-175Ag Epoxy Dispenser

International Journal of Advance Engineering and Research Development STUDY ON IMPACT OF TRAFFIC ON ENVIRONMENT STUDY BY AIR QUALITY INDEX

Eco-Friendly Coal for China Value for the Environment and Value for the Power Generator

Dynex DSX 4-Plate ELISA Processing System. Modular Flexible Reliable A Perfect Combination.

Air Pollution Challenges in Cities and Contribution from Mobile Sources

Make your home a healthier home

Dublin Airport Air Quality Monitoring

Dublin Airport Air Quality Monitoring Q1, Q2 2017

Transcription:

Direct vs Indirect How are you measuring NO2? Do it directly, with the new Serinus 60.

Serinus 60. Because the world needs direct NO 2 measurement like never before. Ecotech presents the latest addition to the renowned Serinus range: The Serinus 60 NO₂ analyser with CAPS technology. Cavity Attenuated Phase Shift (CAPS), allows direct measurement of nitrogen dioxide (NO 2 ), rather than an indirect calculation from a chemiluminescence analyser. Using a modulated blue LED light source, the detector measures the phase shift attributable to the level of NO 2 in the measurement cell over an average path length of several kilometres. No converter, no high vacuum, no ozone and no chemical reactions are required. Never has accurate measurement of NO 2 been more important, or higher on the agenda, for environmental protection. Studies and health reports have raised awareness of the risks to human health from nitrogen dioxide, such as decreased lung function and other respiratory conditions. The solution starts with fast, accurate data, and nothing beats measuring directly. That s why we have launched the Serinus 60; an affordable NO 2 analyser that gives accurate and timely results. FEATURES Measures NO 2 directly - highly selective and no cycle time (switching between NOx and NO) Accurate, repeatable and rapid readings every five seconds Less maintenance than chemiluminescence analysers Low power consumption No converter or ozone generator

A worsening global problem needs effective measures. Nitrogen dioxide is in the forefront of concerns over air pollution in cities worldwide. Authorities have been forced to take drastic measures, such as odd-even number plate days, green taxes, car-scrapping and ride-sharing programmes in an attempt to mitigate the problem. But, as urban populations, industry, vehicle ownership and transportation increase, the underlying issue is getting worse. For environmental protection agencies NO₂ has long been on the radar as a criteria gas. Until the advent of the advanced and more affordable CAPS technology, levels were derived from indirect measurement, posing disadvantages such as precision of measurement and response when levels were dynamic. The Serinus 60 now makes direct, responsive and accurate measurements of this key criteria gas possible. Importantly, it also delivers these advantages in a highly affordable package. News trends around the world. Revolutionary new weapon in air pollution fight. NO 2 emissions rising... Court orders to cut NO 2 air pollution. Very high concentration of nitrogen dioxide continues

Serinus 60. It s a game changer. For years now, the Serinus range has been recognised internationally for precision and usability. The new Serinus 60 is no different. It has been designed from the outset with the user in mind: intuitive to use, simple to configure and offering in-the-field accuracy and reliability. APPLICATIONS FOR PRECISE, DIRECT & RAPID MEASUREMENTS These qualities count, when the risks from NO 2 are under scrutiny like never before. By delivering direct measurement, in an affordable and usable package, Serinus 60 is a huge step forward in addressing NO 2 pollution in an increasingly urbanised world. Traffic emissions monitoring: roadside, tunnels Plume monitoring Ambient air quality monitoring Measurement and monitoring studies Indoor air quality monitoring Medical gas monitoring Mobile and fixed monitoring stations Process control Industrial fence-line monitoring Trace gas monitoring Stack emissions monitoring

Serinus 60. The way it works. Sample IN 5 Micron Sample Filter Background Scrubber Disposable Absorption Unit Calibration Valve Manifold To Vacuum Source Dryer Orifice 0.01 Micron Sample Disposable Filtration Unit Modulated Square Wave Form Emitted Lens Lens Attenuated Wave Form Measured Detector Blue LED Light Source 450 nm Mirror Measurement Cell Mirror Bandpass Filter

The Ecotech advantage. Serinus 60 comes with the backing of Ecotech, a global leader in environmental monitoring since the 1970s. Today, Ecotech is a trusted partner in the protection of workforces, communities and the environment in over 80 countries. We operate and maintain one of the largest networks of monitoring systems in the world. The quality of our products and solutions are second to none, and we re globally recognised for our expertise in technical support. It all stems from the problem-solving mindset that s been part of our DNA since day one, and still drives us today. It goes hand-in-hand with our acute awareness of environmental issues and the need to stay ahead of changes in the natural world. As concern over NO 2 levels rises, we have stepped up to find a more precise and accurate method for monitoring. Designed, manufactured and supported by the proven experts at Ecotech, Serinus 60 is the answer. Ecotech is a trusted partner for governments and industries across 80 countries Ecotech operates and maintains large networks of monitoring systems around the world Ecotech s products have proven performance for reliability and accuracy even in remote and harsh environments Expert technical support services across the world

Serinus 60 options. High Pressure Span Calibration Valve: When a dilution system is not an option calibrate direct from a gas cylinder. Metric Fittings: Do you have issues sourcing imperial tubing? Select our metric fittings option to make pneumatic connection trouble free. Internal Pump: Perfect for compact shelters and remote locations. High Pressure Zero Calibration Valve: Gives you the flexibility to connect your zero gas cylinder directly to the analyser for a simple check. Network Port: Connect your analyser to the internet to have direct remote access from anywhere in the world. Rack Mount Kit: For smooth integration into a 19 rack. Dual Sample Filter: Need more time between sample filter changes? Do you have heavy particulate levels? Use our dual sample filter option to spread the load.

Measure NO 2 directly with the new Serinus 60. Contact Ecotech for ordering and delivery details. Ecotech Pty Ltd T. (Australia) 1300 364 946 T. (International) +61 3 9730 7800 info@ecotech.com ecotech.com