Journal of Asian Scientific Research

Similar documents
IOSR Journal of Engineering (IOSRJEN) ISSN (e): , ISSN (p): Vol. 07, Issue 09 (September. 2017), V1 PP 37-44

Design and life cycle cost analysis of a SAPV system to electrify a rural area household in India

Optimization of hybird PV-Wind Renewable energy system using robust algorithm

Reference: Photovoltaic Systems, p. 229

RURAL ELECTRIFICATION USING RENEWABLE ENERGY SOURCES

Design and Optimization of Photovoltaic-Diesel Generator-Battery Hybrid System for off-grid areas

Feasibility of Renewable Energy Based Distributed Generation in Yanbu, KSA

Design of Grid Connected PV System Using Pvsyst

Optimal Sizing of Photovoltaic Based Rural Electrification System under the Influence of Various Seasonal Conditions

Experimental Study of Using Renewable Energy in Yemen

SIZING CURVE FOR DESIGN OF ISOLATED POWER SYSTEMS

Solar PV, Wind, and Storage System Design. Ilya Chernyakhovskiy, NREL April 26, 2018 Dushanbe, Tajikistan

Micro-Hydrokinetic for Remote Rural Electrification

A SIZING TOOL FOR PV STANDALONE SYSTEM

Design and Performance Analysis of a Grid Connected Solar Photovoltaic System

OPTIMIZATION AND COMPARATIVE ANALYSIS OF NON- RENEWABLE AND RENEWABLE SYSTEM

ANN-Based Sizing of Battery Storage in a StandAlone PV System

Micro-power System Modeling using HOMER - Tutorial 1

SOLAR TRAINING MANUAL (INTERMEDIATE)

LOAD SCHEDULE AND MANAGEMENT FOR RELIABILITY IMPROVEMENT OF PV OFF- GRID SYSTEM. Prepared by: Supervisor Dr. Mo ien Omer

Life-Cycle Cost Analysis and Optimization of Health Clinic PV System for a Rural Area in Oman

Research Article Optimum Availability of Standalone Photovoltaic Power Systems for Remote Housing Electrification

Available online at ScienceDirect. Energy Procedia 110 (2017 ) 89 94

INTEGRATED ELECTRIFICATION SOLUTION FOR REMOTE ISLANDS BASED ON WIND-PV HYBRID SYSTEM

Experimental study of using renewable energy in Yemen

Stand-Alone Photovoltaic (SAPV) System Assessment using PVSYST Software

Journal of American Science 2014;10(8) Software Design of Photovoltaic Grid-Connected Power Plants

MODELING AND SIMULATION OF WIND-SOLAR HYBRID ENERGY SYSTEM FOR POWER SUPPLY TO FACULTY OF ENGINEERING TEACHING WORKSHOP IN UNIVERSITY OF MAIDUGURI

AN ASSESSMENT OF HYBRID DISTRIBUTED GENERATION SYSTEMS IN RURAL ALASKA

Techno Economic Evaluation of Off-grid Hybrid Solar-Wind Power System for Village Malo Bheel, Tharparkar Sindh Pakistan

Off-Grid Hybrid Energy System Incorporating Renewable Energy: The Case of Remote Coastal Area of Bangladesh

Optimal Rural Microgrid Energy Management Using HOMER

TECHO _ECONOMIC EVALUATION OF ELECTRIFICATION OF SMALL VILLAGES IN PALESTINE BY CENTRALIZED AND DECENTRALIZED PV SYSTEM

RESEARCH REPOSITORY.

Optimum Design and Evaluation of Hybrid Solar/Wind/Diesel Power System for Masirah Island

Optimum Design of Biomass Gasifier Integrated Hybrid Energy Systems

Study and Modelling of Green Energy based Micro-Grid for Rural Area

FEASIBILITY ANALYSIS OF A GRID CONNECTED PV/WIND OPTIONS FOR RURAL HEALTHCARE CENTRE USING HOMER

A study for an optimization of a hybrid renewable energy system as a part of decentralized power supply

Ecotourism of Tropical Regions with Renewable Energy Perspective in Indonesia

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

Technical and Economic Feasibility Survey for. Wind and Photovoltaic Hybrid Renewable Energy. System. A Case Study in Neiva-Huila, Colombia

Hybrid energy systems for off-grid remote telecom tower in Odisha, India

13-PV System Design. ECEGR 452 Renewable Energy Systems

EVALUATION OF A MICRO PV-WIND HYBRID SYSTEM IN NORDIC CLIMATE CONDITIONS

OPTIMIZED MODEL FOR COMMUNITY BASED HYBRID ENERGY SYSTEM FOR ST. MARTIN S ISLAND, BANGLADESH

Optimised Model for Community-Based Hybrid Energy System

Renewable Generated Electricity for Enhancement of Sustainable Livelihoods in Rural India

CHAPTER 4 TECHNO-ECONOMIC ANALYSIS OF ISOLATED AND GRID CONNECTED HYBRID SYSTEMS

Performance enhancement of a photovoltaic thermal (PVT) and ground-source heat pump system

GSJ: VOLUME 6, ISSUE 2, FEBRUARY GSJ: Volume 6, Issue 2, February 2018, Online: ISSN

RENEWABLE ENERGY SYSTEMS HYBRID ENERGY SYSTEMS APPLICATIONS

Techno-economic Feasibility Study of a Solar PV- Diesel System for Applications in Northern Part of Bangladesh

Performance Analysis of a Photovltaic System Koya - Kurdistan of Iraq

PERFORMANCE MONITORING OF THE NUNAVUT ARCTIC COLLEGE PV SYSTEM: NINE YEARS OF RELIABLE ELECTRICITY GENERATION *

Performance Analysis of PV Solar Power System

SOLAR ENERGY ASSESSMENT REPORT. For 80.5 kwp. Meteorological Data Source NASA-SSE. Date 18 October, Name of Place Uttar Pradesh.

Al-Ammar: Application of Using Hybrid Renewable Energy in Saudi Arabia

AN EFFECTIVE STUDY ON PERFORMANCE ANALYSIS OF GRID CONNECTED PV SYSTEM

Techno-Economic Feasibility of Stand-Alone Solar PV System for an Educational Institution

Optimizing and Economical Assessment of the Utilization of Photovoltaic Systems in Residential Buildings: The Case of Sari Station, Northern of Iran

Technical and Economic Evaluation of a Solar Photovoltaic (PV) based Distribution Static Synchronous Compensator (DSTATCOM)

OPTIMIZATION OF PV SYSTEM AND TECHNOLOGY IN VIEW OF A LOAD PROFILE- CASE OF PUBLIC BUILDING IN TURKEY

5. Solar Photovoltaic System

SIZING OF ISOLATED HYBRID RENEWABLE POWER SYSTEM WITH DEMAND SIDE MANAGEMENT

A Reliable Solution for JAWWAL s BTS Power Shortages in GAZA using a Photovoltaic System

Research Article Performance Analysis of Hybrid PV/Diesel Energy System in Western Region of Saudi Arabia

Annual Engineering Seminar 2012 Yusak Tanoto

Investigation on Temperature Coefficients of Three Types Photovoltaic Module Technologies under Thailand Operating Condition

POTENTIAL OF APPLICATION OF PV SYSTEM FOR BWRO DESALINATION IN GAZA

Financial Benefits of Integrating East West Fixed, Single and Dual Axes Tracking PV Systems in the Supply Mix of a South African Research Campus

A Feasibility Study of Electrification of a Base Transceiver System (BTS) using Renewable Energy Generators

REQUEST FOR BID (TURNKEY SOLUTION) 1MW GRID TIE SOLAR PV POWER PLANT. Location:

PV Powered DC System for Protection Control and Monitoring (PCM) in Sub-Stations

Optimal Sizing Design for Hybrid Renewable Energy Systems in Rural Areas *

Impact of capacity value of renewable energy resources on RAPS system energy management

IJARIIE-ISSN(O) Optimising Simulated Model of HRES with HOMER Software for Mirkal M

Original Research INTRODUCTION. Bizuayehu Bogale 1, Abiy Alemayehu 2 * Abstract. Article Information Article History:

Index term: wind-solar energy hybrid power generation, optimization control, decision-making model. Plant load factors (PLF)

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Technical Talk on HK s Largest Solar Power System at Lamma Power Station

OPTIMAL SIZING OF A GRID INDEPENDENT STANDALONE PHOTOVOLTAIC SYSTEM WITH BATTERY ENERGY STORAGE

Introduction to Solar Energy Technology

OPTIMAL DESIGN OF A GRID CONNECTED SOLAR PHOTOVOLTAIC POWER SYSTEM FOR A RESIDENTIAL LOAD

ECONOMIC STUDY OF HYBRID PV-BATTERY-DIESEL SYSTEM FOR HOTEL BACKUP GENERATOR

COMPARATIVE STUDY OF PERFORMANCE OF GRID CONNECTED SOLAR PHOTOVOLTAIC POWER SYSTEM IN IIT ROORKEE CAMPUS

Procedures for Photovoltaic System Design Review and Approval

Fact sheet. Photovoltaic systems. Why consider photovoltaics?

Study on Load Profiling and Energy Management Systems

Evaluation of PV, Wind, Diesel Hybrid Energy Potential for GSM Tower in Myanmar

Design and Modelling of a large-scale Solar Water Pumping System for irrigation in Saudi Arabia

Electrical/thermal performance of hybrid PV/T system in Sharjah, UAE

Polycrystalline VS Thin-film solar PV plant in-field performance, Southeast Asia

Optimal sizing of photovoltaic systems using HOMER for Sohar, Oman

An Investigation of a Grid-Connected Solar Powered Water Pumping System. Mohammed Shadman Salam I.D:

Technical Feasibility of Photovoltaic Fuel Cell: A Model of Green Home Power Supply for Rural India

Question # 1: Write true or false with correcting the wrong statement

Techno-Economic Analysis of Building Rooftop Photovoltaic Power System for Lecture Hall at Imo State University, Owerri

HYBRID APPROACH FOR DESIGNING SUSTAINABLE POWER GENERATION SYSTEM IN OFF-GRID ISLAND AREA

Economic Study of Solar Power for an Office Building in Jask Port

Transcription:

Journal of Asian Scientific Research journal homepage: http://aessweb.com/journal-detail.php?id=5003 DESIGN OF A PV/DIESEL STAND ALONE HYBRID SYSTEM FOR A REMOTE COMMUNITY IN PALESTINE M.S. Ismail 1 M. Moghavvemi 2 T.M.I. Mahlia 3 ABSTRACT Hybrid system based on photovoltaic is considered an effective option to electrify remote and isolated areas far from grid. This is true for areas that receive high averages of solar radiation annually. Using diesel generator as a standby source will make utilization of hybrid systems more attractive. An economic feasibility study and a complete design of a hybrid system consisting of photovoltaic (PV) panels, a diesel generator as a backup power source and a battery system supplying a small community in Palestine were presented in this paper. Other scenarios were also studied and analyzed in this paper to ascertain which of them the most appropriate considering cost and pollutant emissions are. A simulation program using iterative approach is developed to optimize the sizes of PV system and battery bank. Specifications of the hybrid system components are then determined according to the optimized values. Solar radiation data is firstly analyzed and the tilted angle of the PV panels is also optimized. Costs of different components, hourly solar radiation and ambient temperatures and other design considerations are inputs of the simulation program. It is found that electrifying rural small community using this hybrid system is very beneficial and competitive with other types of conventional sources as it decreases both operating costs and pollutant emissions. Key Words: Photovoltaic; Hybrid system; Economics; Rural region 1 Department of Electrical Engineering, University of Malaya- Kuala Lumpur, Malaysia Department of Electrical Engineering, Palestine Technical University-Tulkarm,Palestine E- mail: mahmoud_kafa@yahoo.com 2 Department of Electrical Engineering, University of Malaya- Kuala Lumpur, Malaysia Department of Electrical Engineering, University of Tehran-Tehran, Iran 3 Department of Mechanical Engineering, University of Malay- Kuala Lumpur, Malaysia Department of Mechanical Engineering, Syiah Kuala University-Banda Aceh, Indonesia 599

INTRODUCTION Different types of renewable energy sources are nowadays used to supply different applications in rural and urban areas (Bhandari, 2011). Increased reliability and energy security issues are of the most benefits that can be achieved by using hybrid renewable systems (Kamalapur,2011;Daud, 2012). Hybrid systems that depend on photovoltaic (PV) are considered the most popular among other types of renewable systems. The main advantages of this technology are their low maintenance costs and low pollutant emissions (Twaha, 2012). In this paper, a hybrid PV diesel generator battery system for generation of electric energy for a small Palestinian community is analyzed. The block diagram of this system is shown in Figure 1. The type of the hybrid system and its configuration depend mainly on the availability of the renewable source in the location selected for installing this hybrid system. For the Palestinian case, the average daily solar radiation intensity on a horizontal surface is about 5.6 kwh/m 2 while the total annual sunshine hours amounts to about 3000 hours. These values are relatively considered high and very encouraging for using PV generators. For the optimized tilted surface, it is found that this average is about 6.1 kwh/m 2. The highest averages are in summer months (June to August). Optimization of sizes of different components constructing the hybrid system is one of the important issues that shall be considered while designing this system. Maximizing utilization of the renewable source, minimizing the cost of generating energy and minimizing the pollutant emissions are objective functions of this optimization. Khatib (2011) has concluded that a PV/diesel generator hybrid system is the more feasible system compared to a diesel generator system or standalone PV system for Malaysia case. Hrayshat (2009) has used HOMER software to optimize a suggested PV/diesel hybrid system in Jordan that has a climate that approximately likes climate of Palestine. He has reached to the conclusion that the most optimal configuration in for the scenario that involves PV and diesel. A similar study done for a village in Saudi Arabia, Rehman (2010) has suggested many configurations of the desired system using different types and sizes of components to select the optimal one. In this paper, different components making the hybrid system shall be modeled, studied, specified, and chosen appropriately to minimize the system cost. Data analysis of solar radiation measurements are also reviewed and studied in this paper. It is assumed that the optimized configuration shall fulfill the load requirement for each hour in the year (no interruption of power supply). 600

Figure-1. Block diagram of the hybrid system SIMULATION APPROACH As it is stated before, a reliability of 100% is assumed in this study. An energy balance is calculated for each hour in a year to achieve this. This is done by a developed simulation program where hourly data for solar radiation, ambient temperature and load are inputted to it. The energy generated by the PV panels and stored in the battery bank has priority to supply the load. When the battery is discharged to its minimum allowable level, the diesel generator as a backup source is switched on. For each hour step, the developed simulation program compares the load requirement and the available generated energy by the PV system. A decision to charge the battery, discharge it or operate the diesel generator will be taken according to this comparison. In certain cases where the generated energy exceeds the load requirement and the battery bank is fully charged, this excess energy is consumed by a dump load. As it mentioned before, a decision to operate the diesel generator is taken when the battery is discharged to its depth of discharge level and there is no sufficient generated energy by PV system to supply the load. This case continues until the battery is fully recharged where the bidirectional inverter works as a rectifier and permits to charge the battery. The power generated by the PV panels is given by Equation (1) ( Daud, 2012): P PV-out = P N-PV (G/G ref ) [1+ K T (T c - T ref )] (1) where P PV-out is the output power generated from the PV panel, P R-PV is the PV rated power at reference conditions, G is solar radiation ( W/m²), G ref is solar radiation at reference conditions (G ref =1000 W/ m²), T ref is the cell temperature at reference conditions (T ref =25 C), K T is temperature coefficient of the PV panel (K T = - 3.7 x 10-3 (1/ C) ) for mono and poly crystalline silicon. Equation (2) is used to calculate the cell temperature T c such that: 601

T c = T amb + (0.0256 G) (2) where T amb is the ambient temperature in C. The rated power P R-PV can be calculated using the equation P R-PV = (E L SF) / (η R η V PSH) (3) where E L is daily load energy, SF is stacking factor considered to compensate for resistive and PV-temperature losses, η R,,η V are efficiencies of solar charging regulator and bidirectional inverter respectively, and PSH is the peak sun shine hours ( numerically equals to daily average of solar radiation at the specified location). The storage capacity of the battery (C Wh ) is calculated using Eq.(4)(Khatib,2011): C Wh = (E L AD)/ (η V η B DOD) (4) where DOD is allowable depth of discharge of the battery, AD is number of autonomy days, and ηb is battery efficiency. The fuel consumption of the diesel generator depends on the rated power of the generator and the actual output power supplied by it. The fuel consumption of the diesel generator (FC G ) in (l/h) is given by Eq. 5 FC G = A G P G + B G P R-G (5) where P G, P R-G are the output power and the rated power of the generator in (kw) respectively. A G and B G are the coefficients of the consumption curve in (l/kwh) where A G = 0.246 l/kwh and B G = 0.08145 l/kwh for the diesel generator (Daud,2012). Table 1 includes different inputs and part of outputs of the simulation program. Other inputs like metrological data and location specifications are inputted to the simulation program directly or through EXCEL files. The load curve of the small community under study which is also inputted to the simulation program is shown in Figure 2. Table-1. Different inputs and part of outputs of the simulation program Quantity Value Quantity Value PV cost($/kw) 2700 PV panel size (kw) 70.5 PV installation cost ($/kw) 300 Battery capacity (kwh) 335.7 Bi-directional inverter cost ($) 25000 Yearly load demand (kwh) 109500 PV regulator cost ($) 10000 Yearly energy generated by PV 141370 panel (kwh) Battery cost ($/kwh) 225 Yearly energy generated by 17290 diesel generator (kwh) PV regulator efficiency (%) 95 Yearly dump energy (kwh) 29950 602

Load Power (kw) Journal of Asian Scientific Research 2(11):599-606 Bi-directional inverter 92 Diesel generator operating hours 576.4 efficiency (%) (hour) Battery Wh efficiency (%) 85 Yearly fuel consumption (liter) 5708.5 PV life (year) 24 COE ($/kwh) 0.326 Battery life (year) 12 Yearly CO 2 produced (kg) 14271 Diesel generator rated power 30 (kw) Diesel generator cost ($/kw) 800 Diesel fuel price ($/l) 1.73 Diesel engine life (hours) 24000 Figure-2. Hourly typical load curve. 30 25 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Hour (h) In this paper the economic analysis is done based on life cycle costing method where all types of costs for different components (initial costs, maintenance costs, fuel and operation costs, replacement costs, and salvage value) are taken into account. Cost of energy (COE) which is the cost required to produce 1 kwh is the indicator used in the optimization process. It is the ratio between the total annual cost and the total annual energy required by the load. Different economic factors that affect the value of money over the life time of the project are also considered. These rates are: inflation rate and discount rate. The life cycle period of the project is considered 24 years. It is the life cycle of the component that has maximum life time. RESULTS AND DISCUSSION PV data analysis results Analysis of the available hourly PV data for a one year shows that yearly average daily solar radiation on a horizontal surface amounts to 5.6 kwh/m 2. Figure 3 shows yearly energy generated by a 1 kw PV array for different tilted angles in the location considered where hourly data for solar radiation and ambient temperatures are available. It is obvious that the optimum tilted angle is at 30 º. The yearly average daily solar radiation is 6.1 kwh/m 2 at this optimum tilted angle 603

Energy generated and consumed (kwh) PV generated energy (kwh) Journal of Asian Scientific Research 2(11):599-606 Figure-3. Effect of tilted angle variation on PV generated energy 2020 2000 1980 1960 1940 1920 1900 1880 1860 1840 1820 0 10 20 30 40 50 60 PV panel tilted angle () Simulation results The results of the simulation program indicate that the lowest COE obtained is 0.326 $/kwh achieved at 100% PV contribution and 0.7 autonomy days (AD). Table 2 illustrates this result and other results considering different values of PV contribution and different values for autonomy days. Figure 4 shows the contribution of the PV modules and the diesel generator in supplying the load in each month in the year. It is obvious that the diesel generator is off in months May to September where the solar radiation in these months is high. Figure-4. Energy contribution of PV and diesel generator in each month 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 Load Energy PV Energy DG Energy 1 2 3 4 5 6 7 8 9 10 11 12 Month 604

Table-2. COE ($/kwh) for different PV contributions and autonomy days (AD) AD (day) PV contribution (%) 20 40 60 80 100 120 140 160 180 200 0.1 0.704 0.609 0.586 0.585 0.592 0.603 0.620 0.635 0.653 0.606 0.2 0.715 0.558 0.510 0.508 0.519 0.533 0.549 0.567 0.585 0.672 0.3 0.705 0.587 0.583 0.592 0.600 0.612 0.625 0.638 0.652 0.661 0.4 0.743 0.646 0.599 0.531 0.496 0.485 0.486 0.490 0.503 0.516 0.5 0.767 0.616 0.529 0.396 0.364 0.361 0.369 0.379 0.389 0.403 0.6 0.753 0.634 0.508 0.360 0.334 0.331 0.336 0.349 0.363 0.380 0.7 0.756 0.634 0.492 0.353 0.326 0.330 0.342 0.351 0.367 0.383 0.8 0.775 0.632 0.487 0.359 0.333 0.334 0.340 0.352 0.370 0.387 0.9 0.797 0.631 0.488 0.363 0.335 0.339 0.344 0.356 0.374 0.394 1.0 0.790 0.641 0.494 0.370 0.344 0.344 0.348 0.364 0.382 0.402 Other scenarios are also analyzed in addition to the main scenario. It is found that the COE for a PV standalone system (i.e. without diesel generator) is 0.491 $/kwh and occurs at 200% PV contribution and 2 AD. The rated power of the PV modules in this case is 141 kwp and the required storage capacity is 959 kwh. The other scenario is the diesel generator only scenario. For this scenario the COE is 0.774 $/kwh and the amount of yearly produced CO 2 is 97.04 Ton. Hybrid system design The recommended voltage for the DC bus for this hybrid system is 220 V. Other specifications and design issues of main components making his hybrid system are shown in Table 3. Table-3. Specifications of different components constructing the hybrid system Component Specification Number PV Modules Each PV module has 200 Wp,26.3 V as Vmp, and 32.9 V as Voc Number of series PV modules in each string Number of Battery system Each battery has 2 V DC and 400 Ah parallel strings Number of series batteries in each string Number of 4 parallel strings Diesel Generator 30 kw, 3ph, 400 V, 50Hz 1 Charge 30 kw, 360 V input, 220 V 1 Controller output Bidirectional Inverter 30 kw, 400 V, 3-ph ac ouput, 220 V DC input 1 11 32 110 605

CONCLUSION Solar radiation data analysis for the location of the study shows that the yearly average is 5.6 kwh/m 2.day while tilting the PV modules at the optimized angle results in yearly average equals to 6.1 kwh/m 2.day. This angle is found to be 30 º. Three scenarios are analyzed in this paper. The most economic scenario is the one that includes in addition to the PV panels, the battery system and the diesel generator. The COE for this scenario is found to be 0.326 $/kwh and happens at 100% PV contribution and 0.7 AD. Other scenarios dependent on standalone PV and diesel only give results of COE greater than this value. For the diesel only scenario, both the COE and amount of produced CO2 are greater. The amount of produced CO2 is about 7 times greater compared to the hybrid one. This is in fact a very important environmental issue that shall be focused on. Considering remote areas which are far away from the grid, this solution is the most feasible one even compared with electrifying these remote areas from the grid. REFERENCES Bhandari, R. and I. Stadler ( 2011) Electrification using solar photovoltaic systems in Nepal Applied Energy Vol. 88, No.2,pp. 458-465. Kamalapur, G.D. and R.Y. Udaykumar ( 2011) Rural electrification in India and feasibility of Photovoltaic Solar Home Systems International Journal of Electrical Power & Energy Systems Vol. 33, No.3,pp. 594-599. Daud, A-K. and M.S. Ismail ( 2012) Design of isolated hybrid systems minimizing costs and pollutant emissions Renewable Energy Vol. 44, No.,pp. 215-224. Twaha, S., M.H. Idris, M. Anwari and A. Khairuddin ( 2012) Applying grid-connected photovoltaic system as alternative source of electricity to supplement hydro power instead of using diesel in Uganda Energy Vol. 37, No. 1,pp. 185-194. Khatib, T., A. Mohamed, K. Sopian and M. Mahmoud ( 2011) Optimal sizing of building integrated hybrid PV/diesel generator system for zero load rejection for Malaysia Energy and Buildings Vol. 43, No.12, pp. 3430 3435. Hrayshat, E.S. (2009) Techno-economic analysis of autonomous hybrid photovoltaic-dieselbattery system Energy for Sustainable Development Vol. 13, No. 3,pp. 143-150. Rehman, S. A. (2010) Study of a solar PV-diesel-battery hybrid power system for a remotely located population near Rafha, Saudi Arabia Energy Vol. 35, No. 12,pp. 4986-4995. 606