Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine

Similar documents
Disinfection Performance of Peracetic Acid in Florida Wastewater Reuse Applications

Disinfection Performance of Peracetic Acid in Florida Wastewater Reuse Applications

EWRI Pittsburgh Section Meeting October 30, U.S. EPA, Cincinnati, OH CB&I Federal Services LLC, Cincinnati, OH

Control Strategies for PAA Wastewater Disinfection at WWTPs with Variable Effluent Quality

Aquatic Toxicity and Fate of VigorOx WWT II

Control of Trihalomethanes (THM s) In Wastewater. Philip S. Bober, Operations Superintendent, Wayne Township

RI Municipal WWTF Total Residual Chlorine Limits History and Status

Session 311: Effects of TSS on Peracetic Acid Dosing for CSO Events

Wastewater Reuse Solutions in Small Communities by Fixed Film Based Package Treatment and Innovation

ABSTRACT. by Amy Elizabeth Nutter

The Impact of VigorOx WWT II Wastewater Disinfection Technology on Endocrine Disruptors. ED Deactivation Bench Test Procedure

City of Paso Robles Uses Online Monitor to Detect Low-Level of THMs in Treated Wastewater

Disinfection Byproducts in the Drinking Water What Does it Mean and What is Being Done

UV DISINFECTION. Introduction to TrojanUV

Effect of Suspended Particles on Disinfection of a Physicochemical Municipal Wastewater with Peracetic Acid

CITY OF STEUBENVILLE, OHIO WASTEWATER TREATMENT FACILITY

Disinfection of Secondary Effluent Using 22% Peracetic Acid at the M.C. Stiles Wastewater Treatment Facility

THMs Control in Wastewater Treatment Plant Effluent Jurek Patoczka 1, Peter Tyrrell 2 and Michael Wynne 2

ON LINE CONTROL STRATEGIES FOR DISINFECTION SYSTEMS: SUCCESS AND FAILURE

Using PAA as an Alternative WWTP Disinfection Method

THM Analysis From Compliance to Optimization

Ecotoxicity evaluation of pure peracetic acid (PAA) after eliminating hydrogen peroxide from commercial PAA

A New Approach to Drinking Water Nitrate Removal. Ali Dorri Director of Business Development

WEFTEC.06. ** Hatch Mott McDonald Gateway View Plaza, 1600 West Carson Street Pittsburgh, Pennsylvania. *** City of Akron Akron, Ohio

USEPA s Pursuit of New Ambient Water Quality Criteria for Bacteriophage:

Present Disinfection Practices and Solution for the Future Ashbridges Bay Treatment Plant

Registration Decision. Proxitane

Annual Drinking Water Quality Report for Village of Lisle 2612 Liberty Street P.O. Box 729 Whitney Point, NY 13862

The Application and Measurement of Peracetic Acid for Wastewater Disinfection

Annual Drinking Water Quality Report Village of Chatham, NY 77 Main St., Chatham, NY (Public Water Supply ID# ) June 1, 2011

ATTACHMENT A TO THE AGREEMENT FOR ENGINEERING SERVICES. Project: Chloramine Replacement Alternative Evaluation

Introducing ClearBlue 104

Wastewater Treatment Works... The Basics

Toxicity Report. Section 1. Overview

WASTEWATER DEPARTMENT. Bentonville Wastewater Treatment Plant Facts:

Whole Effluent Toxicity (WET) Testing

NJWA Presents DISINFECTION BYPRODUCTS: TREATMENT OPTIONS & CHALLENGES. Stage 2 D/DBPR. Trihalomethanes DISINFECTION BYPRODUCTS.

Chlorination/Dechlorination: An Environmental Solution

The city of Clearwater operates and

Facilities Plan. Technical Memorandum Nos. TM-CSO-11 and TM-WW-5 Disinfection Facilities

Scavenger2000 s Technology

USPE Environmental Conference Nashville, TN March 10, 2011

Comparative Toxicity of Eight Oil Dispersant Products on Two Gulf of Mexico Aquatic Test Species

2017 Annual Drinking Water Quality Report Town of Edenton Water System Number

Homework #7 Topic: Disinfection Due Tues., April 12 Assignment for 2018: Answer problem 1; then choose two of problems 4, 5, 8.

Peracetic Acid for Municipal Water and Wastewater Related Processes Online Workshop for Regulators: Part 1

University of South Florida

2015 CONSUMER CONFIDENCE REPORT. Travis AFB, CA

CGN 6933: Drinking Water Treatment Processes Department of Civil & Environmental Engineering University of South Florida Cunningham Spring 2013

Surfside Homeowners Association

UV-OXIDATION. Environmental Contaminant Treatment

BROCKVILLE CITY OF THE 1000 ISLANDS BROCKVILLE WATER POLLUTION CONTROL CENTRE UPGRADE CLASS ENVIRONMENTAL ASSESSMENT REPORT

UV Disinfection for a Municipal Wastewater Lagoon Effluent No Prior Filtration Needed? Wayne Wong, M.A.Sc., P.Eng., PMP

2017 Water Quality Report

Water sanitation at its best

Applied Environmental Microbiology. Copyright McGraw-Hill Global Education Holdings, LLC. Permission required for reproduction or display.

Disinfection and Disinfection Byproducts (DBP)

Disinfection of Total Coli-forms in the Effluent from Municipal Wastewater Plant with e- Beam. June 07, EB TECH Co.

East Hanover Water Quality Report 2014 PWS ID#

SESSION 10. Operational Savings through Online THM Monitoring

Balancing Microbial Control and Stage 2 DBP Rule Compliance (at Ocean City, Maryland)

Module 5: Disinfection and Chlorination Answer Key

EFFECTIVE STRATEGIES FOR RESIDUAL POLYMER AND AQUATIC TOXICITY TESTING FOR DREDGE SLURRY DEWATERING

RECLAIMED WATER DISINFECTION ALTERNATIVES TO AVOID NDMA AND THM FORMATION

Village of Lockland, Ohio. What s On Tap?

Annual Drinking Water Quality Report for 2017

Texas A&M Wastewater Treatment Plant 9685 Whites Creek Rd., College Station, TX

3 8 COLIFORM BACTERIA AS INDICATOR ORGANISMS Laboratory tests for disease-producing bacteria, viruses, and protozoa are difficult to perform

American Water College 2010

Ozone. However, new concerns have arisen about the ability of chlorine to inactivate. TechCommentary,/Vol. 1/No. 4 1

Consumer Confidence Report

Village of Ada Water Department 2014 Drinking Water Quality Report

Case Study. Biological Help for the Human Race. Bathurst Municipal Wastewater Treatment Works, New South Wales, Australia.

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

As part of its program to help protect the quality of urban waterways and Lake Erie, the

MUNICIPAL SUPPLY DOCUMENT

ANNUAL WATER QUALITY REPORT FOR CALENDAR YEAR 2013 CITY OF POUGHKEEPSIE

Drinking Water Disinfection A History and Improved Monitoring Techniques. Randy Turner Technical Director, Chemist Swan Analytical USA

Advanced Oxidation Systems

VC Series Wastewater. Vertical Open Channel Ultraviolet Disinfection

Implementation of Emerging Technologies: Treatment Capability of Peracetic Acid and Ultraviolet Irradiation. Samantha Cooper

INTRODUCTION TO UV-OXIDATION FOR ENVIRONMENTAL CONTAMINANT TREATMENT

PRACTICAL CONSIDERATIONS OF APPLYING UV TECHNOLOGY FOR REUSE WATER DISINFECTION. Wayne Lem. Trojan Technologies

Reporting and Testing Guidance for Biomonitoring Required by the Ohio Environmental Protection Agency

Town of Boiling Springs

2015 Annual Drinking Water Quality Report Wells College Water Department PO Box 500 Aurora, NY (Public Water Supply ID# )

TOTAL TRIHALOMETHANES (TTHM) MITIGATION FEASIBILITY STUDY AND PILOT TESTING ABSTRACT KEYWORDS

MEDIUM PRESSURE UV TREATMENT OF BALLAST WATER Yeojoon Yoon¹, Yeonjung Jung¹, Tae Sung Pyo², Soo-Tae Lee², Kyoungsoon Shin³, and Joon-Wun Kang¹

Overview of Chapter 21

APPLICATIONS AND SUSTAINABLE WATER SOLUTIONS FOR. Food and Beverage

City of Plymouth Consumer Confidence Report & Annual Water Quality Report

DE-CHLORINATION PRODUCTS

2014 Water Report Consumer Confidence Report

Issues. Issues (cont.) A multiple barriers approach is required to provide potable water

Optimization of Anaerobic Digestion with Bio- Organic Catalyst Compositions (BOCs)

VILLAGE OF GREENWICH STATE OF OHIO Administration Offices: 45 Main Street. Greenwich, Ohio (419)

customer confidence report

FROM RAW WATER INTAKE TO DISTRIBUTION NETWORK: THE JOURNEY OF DBP CONTROL

ULTRAVIOLET DISINFECTION 2013 Municipal Markets.

Gretchen Onstad ENV H /15/11

Transcription:

Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine Situation Wastewater treatment plants are required to disinfect effluent prior to discharge in order to destroy any pathogenic organisms present and minimize public health concerns. Chlorine has been the principal disinfection method in the wastewater industry, despite the fact that disinfection with chlorine produces chlorinated disinfection byproducts (DBPs), including trihalomethanes (TTHMs) that are toxic to aquatic life. In recent years, many municipalities have been required to install dechlorination systems in order to address DBPs, but upgrading an existing plant with a dechlorination process typically results in significant capital cost and operational complexity. The 2.7 million-gallon-per-day (MGD) wastewater treatment plant in St. Augustine has a chlorination/dechlorination disinfection system, but plant officials decided to seek an alternative disinfection process that did not generate DBPs, was cost effective, and was simple to operate. The plant investigated disinfection options such as ozone and ultraviolet disinfection, but VigorOx WWT II disinfection was deemed the most attractive option because the plant s existing contact chamber could be used for the VigorOx WWT II technology, providing large capital cost savings to the municipality. Figure 1: St. Augustine Wastewater Treatment Plant After successful bench-scale testing with VigorOx WWT II, a full-scale demonstration test was conducted to evaluate the performance of the VigorOx WWT II disinfection system compared to the existing chlorination/dechlorination system, based on several evaluation criteria: Disinfection performances Aquatic toxicity Disinfection byproducts Chemical consumption/sustainability Trial Overview Disinfectant: VigorOx WWT II was selected for the study. The product is a proprietary 15-percent peracetic acid formulation that is approved by the U.S. Environmental Protection Agency for wastewater disinfection, EPA Reg. No. 65402-8. The VigorOx WWT II solution breaks down to the non-harmful products water, oxygen, and acetic acid (vinegar).

Disinfection Layout: The St. Augustine Wastewater Treatment Plant (Figure 1) has two identical disinfection contact tanks. Each tank receives 50 percent of the 2.7-MGD plant flow. After a consultation, plant management deployed VigorOx WWT II disinfection system consisting of a storage tank, a dispensing system, and a residual monitor to treat the first contact tank. The second contact tank continued to operate using the existing chlorination/dechlorination system, enabling plant managers to conduct a direct, head-to-head comparison of the two technologies. Both disinfection systems were connected to the plant s SCADA system and identical flow pacing equipment was installed at each contact tank. The flow pacing equipment enabled chemical dosage and flow rates to be controlled in real time. The plant s flow data, pathogen counts, chemical dosage rates, and residual data were recorded during the trial. Trial Results Disinfection performances: A wastewater disinfectant s performance can be quantified based on two specific pathogens of concern: enterococci and fecal coliform (FC). Effluent grab samples from both disinfection tanks were tested several times a week. Enterococci: Figure 2 shows that an average concentration of 1.5 parts per million (ppm) VigorOx WWT II reduced the enterococci count between 1 and 6 CFU/100mL, well below the plant discharge limit of 35 CFU/100 ml. The average chlorine dose of 7 ppm yielded similar enterococci results to VigorOx WWT II with one outlier at 29 CFU/100mL. Thus, the test demonstrated an opportunity for the plant to use a lower concentration of VigorOx WWT II (versus chlorine) and still meet enterococci disinfection requirements. Fecal Coliform (FC): The plant s discharge permit limit for FC is 200 CFU/100mL. Figure 3 shows the VigorOx WWT II treatment performance side by side with the chlorination/dechlorination treatment

performance. The data showed that an average VigorOx WWT II dosage of 1.5 ppm yielded similar disinfection performance to an average chlorine dosage of 7 ppm, and that both disinfection processes were effective in keeping FC count below the discharge limit. Aquatic Toxicity Results: Wastewater can produce adverse effects on the biological system, damaging its infrastructure and causing death to aquatic life. The criteria for aquatic toxicity testing are mortality and reproduction rate. Mysidopsis bahia (mysid shrimp) and Menidia beryllina (tidewater silverside) were the species used for both acute and chronic toxicity testing. During the trial, testing for acute and chronic toxicity at dilution levels ranging from 0 percent (control) to 100 percent effluent. The first set utilized treated effluent from the chlorination/dechlorination process (Table 1). The second set utilized the VigorOx WWT II-treated effluent (Table 2). Table 1: Toxicity results from chlorination/dechlorination M. bahia M. beryllina % Survival Growth Survival Growth Control 97.5 0.390 100 2.096 6.25 85 0.375 97.5 1.986 12.5 97.5 0.415 97.5 2.333 25 90 0.372 100 2.226 50 77.5 0.414 100 2.562 100 82.5 0.377 97.5 2.506 Table 2: Toxicity results from VigorOx WWT II M. bahia M. beryllina % Survival Growth Survival Growth Control 92.5 0.353 100 2.374 6.25 90 0.383 100 2.487 12.5 95 0.380 100 2.491 25 95 0.396 100 2.426 50 90 0.377 100 2.563 100 97.5 0.358 97.5 2.337 The toxicity results show a higher survival rate for the M. bahia and the M. beryllina in the VigorOx WWT II treated effluent when compared to the chlorination/dechlorination treated effluent. The growth rate results for both disinfection systems were comparable. The overall trend showed that VigorOx WWT II was slightly less toxic to aquatic life than chlorination/ dechlorination. DBP Results: DBPs are chemicals formed as a result of the reaction between the disinfectant added to the water and naturally occurring organic material present in the water. The U.S. Environmental Protection Agency has established

discharge effluent limits for DBPs (Tables 3 & 4). DBP results from a chlorine treatment test are presented in Table 3. Untreated effluent grab samples were taken from the plant s side stream and tested for DBPs once chlorine was added (chlorine start), after disinfection was completed (chlorine end), and after the dechlorinating agent was added (after dechlorination). Total trihalomethanes (TTHMs) concentration was found to be 194.19ug/L after disinfection. After the dechlorinating agent was added, TTHMs concentration decreased to 170.70ug/L, suggesting that the dechlorinating agent had only a limited capability of reducing TTHMs concentrations. Results showed that there were virtually no TTHMs generated by the VigorOx WWT II disinfection process. Currently, many wastewater treatment plants in North America are having difficulty meeting DBP permits. This trial test suggested that conversion to VigorOx WWT II disinfection could provide a low-capital solution to resolve DBP issues. Table 3: Disinfection byproducts from a chlorination/dechlorination treatment Volatiles Effluent limit (annually) Chlorination start Chlorination end Bromodichloromethane [ug/l] 22 95.55 65.72 56.82 Bromoform [ug/l] 360 22.64 20.90 19.62 Chloroform [ug/l] 470.8 49.25 26.13 21.55 Dibromochloromethane [ug/l] 34 102.99 81.44 72.71 Total Trihalomethanes [ug/l] - 270.43 194.19 170.70 After de-chlorination Table 4: Disinfection byproducts from a chlorination/dechlorination treatment Volatiles Effluent limit (annually) VigorOx WWT II start VigorOx WWT II end Bromodichloromethane [ug/l] 22 0.6 0.6 0.6 Bromoform [ug/l] 360 0.6 0.6 0.6 Chloroform [ug/l] 470.8 0.64 0.64 0.64 Dibromochloromethane [ug/l] 34 0.75 0.75 0.75 Total Trihalomethanes [ug/l] - 0.6 0.6 0.6 After de-chlorination Other results: The plant s SCADA data revealed that the average chemical usage for chlorination/ dechlorination system was 235 gallons per day, while the VigorOx WWT II system used only 23 gallons per day of chemical to meet the same disinfection requirements. Plant operators observed that the VigorOx WWT II treatment was easier to adjust and maintain dosing in response to rapid changes in plant flow rate, compared to the chlorine system. This may be attributed to the lower VigorOx WWT II chemical feed rate compared to that of chlorine. Field studies have demonstrated that changes in wastewater characteristics can impact the dosage of VigorOx WWT II required for effective pathogen control. In order to address this challenge, a proprietary VigorOx WWT II analyzer unit that can accurately measure and record PAA residuals in real time was developed. It may be integrated with a plant s automated control system and flow pacing equipment to enable plant operators to adjust VigorOx WWT II dosage rates based on real time to help ensure consistent pathogen control while optimizing chemical consumption.

Conclusion The objective of the St. Augustine trial was to compare the VigorOx WWT II disinfection system to a chlorination/dechlorination system at a full scale over an extended period based on pathogen results, environmental impact, and cost. At the St. Augustine plant, the VigorOx WWT II system achieved equivalent disinfection performance for both enterococci and fecal coliform compared to the chlorine treated system. The VigorOx WWT II system was found to have some environmental advantages, since it did not generate DBPs and exhibited less toxicity to aquatic life. The VigorOx WWT II system was found to be 10 percent less expensive compared to the chlorination/dechlorination system because VigorOx WWT II was more efficient, with 1.5 ppm VigorOx WWT II concentration delivering equivalent microbial performance to 7.0 ppm of chlorine. Finally, the VigorOx WWT II system offered the St. Augustine plant some additional soft benefits, including the opportunity to reduce its overall disinfection chemical consumption by 90 percent and to respond more rapidly to changes in flow rates. Acknowledgement The authors wish to thank the St. Augustine Public Works Department, which played an important role in making this project possible. References [1] S. Rossi, M. Antonelli, V. Mezzanotte, and C. Nurizzo, Peracetic Acid Disinfection: A Feasible Alternative to Wastewater Chlorination, Water Environment Research, vol. 79, 2007, pp. 341-350. [2] A. Dellerba, D. Falsanisi, L. Liberti, M. Notarnicola, and D. Santoro, Disinfecting behaviour of peracetic acid for municipal wastewater reuse, Desalination, vol. 168, 2004, pp. 435-442. [3] M. Kitis, Disinfection of wastewater with peracetic acid: a review, Environment International, vol. 30, 2004, pp. 47-55. [4] D. Chen, X. Dong, and R. Gehr, Alternative Disinfection Mechanisms for Wastewaters Using Combined PAA/UV Processes, Water Environment Federation, 2005, pp. 886-906. [5] J. Koivunen and H. Heinonen-Tanski, Inactivation of enteric microorganisms with chemical disinfectants, UV irradiation and combined chemical/uv treatments, Water Research, vol. 39, 2005, pp. 1519-1526. [6] M. Wagner, D. Brumelis, R. Gehr, Dis- infection of Wastewater by Hydrogen Peroxide or Peracetic Acid: Development of Procedures for Measurement of Residual Disinfectant and Application to a Physicochemically Treated Municipal Effluent, Water Environment Research, vol. 74, 2002, pp. 33-50. The information contained herein is, to our knowledge, true and accurate. However, we make no warranty or representation, expressed or implied, and nothing contained herein should be construed as permission or recommendation to infringe any patent. All intellectual property rights to this material are retained by PeroxyChem.