Nu-Wool U382 2 Hour Firewall Guide Please note that this firewall can only be installed by approved Nu-Wool U382 installers

Similar documents
A.ENVELOPE AIR SEALING

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

Chapter 14 - Air Sealing

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

Chapter 4: Insulation

Feature Zone IECC 2009 IECC

Project Name: Enforcement Agency: Permit Number:

SECTION THERMAL INSULATION

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Building Division Informational Handout

Standard Practice for Installing Sound-Isolating Lightweight Partitions 1

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

SECTION NON-STRUCTURAL METAL FRAMING

2. Heat Transfer is quantified in British Thermal Units (BTU s)

GYPSUM BOARD

SECTION GYPSUM BOARD

Andy Schreder CBO Building Official for St Francis, Nowthen

FIELD COPY ATTACHMENT

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

Table Air Barrier and Insulation Inspection Component Criteria

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

Hardin County Planning and Development Commission

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Dead Load Weight of Roof Trusses. Dead Load Weight of Floor Trusses

Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4)

Explaining the Thermal Bypass Checklist. Ed Minch, Energy Services Group Kelly Parker, GWS

FIRESTOP 201 WHAT EVERY A&E PROFESSIONAL SHOULD KNOW CHRIS ALLINGTON - HILTI - CHRIS LYNCH - CODE RED CONSULTANTS NATHAN BENNETT - HILTI

SECTION GYPSUM BOARD

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

ACCESSORY BUILDING. Building Permit Requirements: (must be completed before submitting application)

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

UL Design System HW-D-1012 continued

Cavity ShAftwall System

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

WoodWorks. Learning Objective. Presentation Overview. Fire Protection II Requirements for rated assemblies and common detailing

Student Services & Classroom Addition

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

Gypsum Board Systems Manual

G703 Continuation Sheet Minimum Schedule of Values Please use the breakdown listed below when submitting your billing for the project

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

STEEL FRAMING INDUSTRY ASSOCIATION OBSERVATION REPORT PROTOCOL STRUCTURAL FRAMING GUIDELINES FOR THE INSPECTOR

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

Where to Draw the Line with Thermal Boundaries

FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK

SECTION GYPSUM BOARD PART 1 - GENERAL

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

Inspection of New One- and Two- Family Dwellings

INSTALLATION GUIDE GUIDE TO ASC ISO-WALL CONSTRUCTION SYSTEM APPLICATION ISO-WALL SYSTEM. ASC Iso-Wall System Includes: Materials Required:

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017

Intertek Testing Services

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Prescriptive Checklist for the 2015 Washington State Energy Code

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

RSH ENGINEERING, INC. END OF BUILDERS WARRANTY INSPECTION REPORT INSP#: K00001 DATE: 00/00/11 PAGE #: 1

FIGURE R502.2 FLOOR CONSTRUCTION

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Success with 2012 NC Energy Conservation Code in North Carolina: Tech Tips for Builders. insulation

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

Garage/Accessory Structures

206 Basic Construction Management

IRC 2012 Key Changes

Type III Fire-Resistant Design and Detailing: Exterior walls, Intersections and Balconies. For Light-Frame Wood Construction

The Inspection Process. Waxhaw N.C.

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

The GlasRoc Shaftliner Type X advantage...

Strong-Drive SDWS TIMBER Screw

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

Structural Technical Report #2 By Robert Whitaker

Ash Brook Golf Course Scotch Plains, New Jersey

TYPICAL BEARING WALL FRAMING

APPLICATION FOR FINISHED BASEMENT PERMIT

Presented by: Stephen Carr Regional Building Science Manager (386)

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Chapter 19 - Interior Insulation

SECTION GYPSUM BOARD

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

INSULATION INSTALLATION

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

THE FLORIDA BUILDING CODE

City of Kasson Building Permit Process

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Boulder City NV Prepared by (Print Name) Signature Date

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

ADDENDUM A CONSTRUCTION SPECIFICATIONS

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Presented by: Stephen Carr Regional Building Science Manager (386)

Building for Energy Efficiency Part 2 Advanced Framing Workshop. Objectives for this presentation...

SECTION GYPSUM BOARD SYSTEM

Flanking Transmission at Joints in Multi-Family Dwellings. Phase 1: Effects of Fire Stops at Floor/Wall Intersections

Transcription:

Nu-Wool 2 Hour Firewall Guide Please note that this firewall can only be installed by approved Nu-Wool installers For Information, please contact: Bill Hulstrunk (413) 668-6133 Rev 01/13

Wall Construction Double row of staggered 2x4 studs. Opposite rows spaced 1 in. apart. Bearing plates: Two layers on the top and one layer on bottom. Continuous 5/8 Type C drywall on both sides. Nu-Wool WALLSEAL installed at a density of 4.6 lbs/ft. 3 Cross-bracing at midheight or diagonally. Side View Top View

Cross-Bracing

Note: Unlike this picture, the 2 x 4 cross bracing should be staggered on each of the two sides of the firewall

Partition Walls and Other Issues In order for the type C drywall to be continuous, the type C drywall must be installed before framing any intersecting partition walls. Any partition wall framed directly against the firewall without type C drywall behind it will need approval by the appropriate local code official. Make sure that the type C drywall is continuous behind the stairwell, tub and shower enclosures, cabinets, built ins or any drop soffits or drop ceiling areas.

Firewall Penetrations All wire penetrations must be fire sealed No gas lines or waste pipes can run inside the firewall All plumbing penetrations must have U.L. approved collars and assembly listings

All Outlets in Firewall Must be 2 Hr UL Approved Electrical boxes must not exceed 100 square inches per 100 square feet

Wall Construction Review Two ways to frame the wall: Blocking staggered at 4.5 feet on each of the walls or diagonal bracing between walls Continuous type C drywall must be installed. One layer of type C drywall must be installed prior to application of insulation. Minimum gap between the framed walls is 1 inch. 4.6 lbs./ft. 3 tested Nu-Wool insulation density.

Floor-Ceiling Assembly There is no ASTM test for this area of the wall system. There is no third party testing facility to ensure an hourly rating. The builder/architect doesn t need to change anything they are specifying right now.

Floor-Ceiling Assemblies Perpendicular floor joists. (Rim & Band Joist application) Attic, floor-ceiling assembly, and foundation details will vary. Two layers of Type X drywall must extend from the bottom of the top plate on the lower wall and extended up to the top of the bottom plate on the upper wall (area circled). 5/8" GYP. BD. CEILING (TYP.) DOUBLE TOP PLATE (TYP.) 2 LAYERS TYPE X GYP. BD. 5/8" GYP. BD. CEILING (TYP.) CONTINUOUS RIMBOARDS - SEE STRUCTURAL DESIGN SECOND FIRST FLOOR FLOOR INSULATION PER SPECS WALLSEAL INSULATION (SLAB TO ROOF DECK) FLOOR-CEILING INTERSECTION MAY VARY BY LOCALE AND MUST BE APPROVED BY LOCAL INSPECTOR SEE FRAMING PLANS FOR FLOOR SYSTEM USED (PERPENDICULAR FLOOR JOIST CONDITION SHOWN) NU-WOOL WALLSEAL - APPLIED BETWEEN JOISTS AT A DENSITY OF 4.6 LBS./CUBIC FT. (MUST BE INSTALLED BY A NU-WOOL CERTIFIED DEALER) WALLSEAL INSULATION (SLAB TO ROOF DECK) SEE FOUNDATION PLAN FOR FOOTING DETAIL (FOUNDATION SYSTEM MAY VARY)

Floor-Ceiling Assemblies (cont.) Parallel floor joists. The wall system is fully load bearing so this wall detail may be rare. Two layers of Type X drywall must extend from the bottom of the top plate on the lower wall and extended up to the top of the bottom plate on the upper wall (area circled). 5/8" GYP. BD. CEILING (TYP.) DOUBLE TOP PLATE (TYP.) 5/8" GYP. BD. CEILING (TYP.) CONTINUOUS RIMBOARDS - SEE STRUCTURAL DESIGN (Material May Vary) SECOND FIRST FLOOR FLOOR INSULATION PER SPECS WALLSEAL INSULATION (SLAB TO ROOF DECK) FLOOR-CEILING INTERSECTION MAY VARY BY LOCALE AND MUST BE APPROVED BY LOCAL INSPECTOR SEE FRAMING PLANS FOR FLOOR SYSTEM USED (PARALLEL FLOOR JOIST CONDITION SHOWN) 2 LAYERS TYPE X GYP. BD. WALLSEAL INSULATION (SLAB TO ROOF DECK) SEE FOUNDATION PLAN FOR FOOTING DETAIL (FOUNDATION SYSTEM MAY VARY)

Floor-Ceiling Assemblies (cont.) Perpendicular floor joists. (Rim & Band Joist application) Attic section dependant on inspector. Two layers of Type X drywall must extend from the bottom of the top plate on the lower wall and extended up to the top of the bottom plate on the upper wall (area circled). 5/8" GYP. BD. CEILING (TYP.) DOUBLE TOP PLATE (TYP.) 2 LAYERS TYPE X GYP. BD. 5/8" GYP. BD. CEILING (TYP.) CONTINUOUS RIMBOARDS - SEE STRUCTURAL DESIGN SECOND FIRST FLOOR FLOOR ATTIC SYSTEM MAY VARY BY LOCALE - THE ATTIC SYSTEM MUST BE APPROVED BY A LOCAL BUILDING OFFICIAL INSULATION PER SPECS WALLSEAL INSULATION FLOOR-CEILING INTERSECTION MAY VARY BY LOCALE AND MUST BE APPROVED BY LOCAL INSPECTOR SEE FRAMING PLANS FOR FLOOR SYSTEM USED (PERPENDICULAR FLOOR JOIST CONDITION SHOWN) NU-WOOL WALLSEAL - APPLIED BETWEEN JOISTS AT A DENSITY OF 4.6 LBS./CUBIC FT. (MUST BE INSTALLED BY A NU-WOOL CERTIFIED DEALER) WALLSEAL INSULATION SEE FOUNDATION PLAN FOR FOOTING DETAIL (FOUNDATION SYSTEM MAY VARY)

Floor-Ceiling Assemblies (cont.) Perpendicular floor joists. (Rim & Band Joist application) Foundation will vary. No need to change the attic detail the builder/architect has been using. Two layers of Type X drywall must extend from the foundation extending up to the top of the bottom plate on the upper wall (area circled). 5/8" GYP. BD. CEILING (TYP.) DOUBLE TOP PLATE (TYP.) 2 LAYERS TYPE X GYP. BD. 5/8" GYP. BD. CEILING (TYP.) CONTINUOUS RIMBOARDS - SEE STRUCTURAL DESIGN SEE FOUNDATION PLAN FOR WALL DETAIL (FOUNDATION SYSTEM MAY VARY) SECOND FLOOR ATTIC SYSTEM MAY VARY BY LOCALE - THE ATTIC SYSTEM MUST BE APPROVED BY A LOCAL BUILDING OFFICIAL INSULATION PER SPECS WALLSEAL INSULATION FLOOR-CEILING INTERSECTION MAY VARY BY LOCALE AND MUST BE APPROVED BY LOCAL INSPECTOR SEE FRAMING PLANS FOR FLOOR SYSTEM USED (PERPENDICULAR FLOOR JOIST CONDITION SHOWN) NU-WOOL WALLSEAL - APPLIED BETWEEN JOISTS AT A DENSITY OF 4.6 LBS./CUBIC FT. (MUST BE INSTALLED BY A NU-WOOL CERTIFIED DEALER) SEE FOUNDATION PLAN FOR FOOTING DETAIL (FOUNDATION SYSTEM MAY VARY)

Floor-Ceiling Assemblies (cont.) Perpendicular floor joists. (Rim & Band Joist application) Builders/Architects must get floor-ceiling intersection approved through local building department. Two layers of Type X drywall must extend from the foundation extending up to the top of the bottom plate on the upper wall (area circled). 5/8" GYP. BD. CEILING (TYP.) DOUBLE TOP PLATE (TYP.) 2 LAYERS TYPE X GYP. BD. 5/8" GYP. BD. CEILING (TYP.) CONTINUOUS RIMBOARDS - SEE STRUCTURAL DESIGN SEE FOUNDATION PLAN FOR WALL DETAIL (FOUNDATION SYSTEM MAY VARY) SECOND FLOOR INSULATION PER SPECS WALLSEAL INSULATION (BASEMENT WALL TO ROOF DECK) FLOOR-CEILING INTERSECTION MAY VARY BY LOCALE AND MUST BE APPROVED BY LOCAL INSPECTOR SEE FRAMING PLANS FOR FLOOR SYSTEM USED (PERPENDICULAR FLOOR JOIST CONDITION SHOWN) NU-WOOL WALLSEAL - APPLIED BETWEEN JOISTS AT A DENSITY OF 4.6 LBS./CUBIC FT. (MUST BE INSTALLED BY A NU-WOOL CERTIFIED DEALER) SEE FOUNDATION PLAN FOR FOOTING DETAIL (FOUNDATION SYSTEM MAY VARY)

Acoustics TOP PLATE 2 LAYERS 5/8" GYP. BD. STC 58 (Double Layer of Drywall on One-Side) WALLSEAL INSULATION (SLAB TO ROOF DECK) TOP PLATE STC 53 (Standard) WALLSEAL INSULATION (SLAB TO ROOF DECK) TOP PLATE 2 LAYERS 5/8" GYP. BD. 2 LAYERS 5/8" GYP. BD. STC 63 (Double Layer of Drywall on Both Sides) WALLSEAL INSULATION (SLAB TO ROOF DECK)

Alternate 2 Hr Firewall Design U360 This firewall design does not require the special certification and therefore can be insulated by any Nu-Wool Installer

Firewall Continued