CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE

Similar documents
Corrosion Under Insulation Detection Methods and Inspection

An Examination of Surface Morphology and In-Situ Study on ASTM A106-Gr.B CUI Piping in EDC Plant

Corrosion Under Insulation and Fire Proofing Materials V. P. Sastry TCR Arabia Company Ltd.

CORROSION UNDER INSULATION (CUI) A Nanotechnology Solution. Explanation:

NACE International The Worldwide Corrosion Authority by NACE International All Rights Reserved Printed in the United States of America

Corrosion Under Insulation (CUI) and the Insulation System. By Soeren Nyborg Rasmussen ROCKWOOL Technical Insulation, Jubail, 10 December 2015

Corrosion and Thermal Insulation in Hot areas A New Approach

B. Refer to Section : Air Distribution for lined ductwork requirements.

Corrosion Under Insulation

Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems

Match your Inspection Ports to your Process Temperatures

James E. Parker \ Sr. Director of Business Development - Amerapex. CUI Technical Workshop NACE - Jubail Dec 10th 2015

Designing for Mechanical Integrity: Piping

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

Mechanical Insulation for Refrigeration Systems

Corrosion Under Insulation (CUI) inspection of cold insulated lines

Corrosion Under Insulation

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

Best Practice On Insulation Of Process Installations

Corrosion in GASCO Habshan CBA Units and its mitigation

This specification describes the minimum requirements for industrial thermal insulation.

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Design & Construction Standards, Revised January

Corrosion Under Insulation CUI

Coating Applications - Chemical

sites under the deposit become anode and the lead to pitting. Hence, a good design should not allow the built up of impurities on surface

10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING FINISHES 2

UBC Technical Guidelines Section Edition Thermal Insulation for Piping Page 1 of 5

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES

FRAZIER RELIABILITY SOLUTIONS

CORROSION UNDER INSULATION WHY CUI IS NOT THE PROBLEM A TOPICAL DISCUSSION ON THE CHALLENGES THAT DRIVE THE PROBLEM OF CORROSION UNDER INSULATION

OUTLINE ATMOSPHERIC CORROSION INTEGRITY MANAGMENT

Quality NBR Insulation

STANDARD ENGINEERING SPECIFICATION for THERMAL INSULATION DESIGN

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT

On-Line Repair Solutions for Corrosion Under Insulation

Plant Aging and Life Extension Program. at Arun LNG Plant. Lhokseumawe, North Aceh, Indonesia

PIP INSC1000 Cold Service Insulation Materials and Installation Specification

This presentation covers process steam energy reduction projects supported by the Ameren Illinois ActOnEnergy program.

Subject Index. STP880-EB/Aug. 1985

INSTALLATION GUIDELINE FOR TRYMER INSULATION

Customized test for detecting the atmospheric corrosion resistance of uncoated AISI 316 type stainless steel in marine environment

SECTION HVAC PIPING INSULATION

INSTALLATION GUIDELINES FOR CHILL WATER PIPE INSULATION

Heat Transfer Compounds

Addendum to Specifications

Protection Effectiveness of Vapor Corrosion Inhibitor VpCI 619 for Corrosion Under Insulation at Elevated Temperatures

HEAT-FLEX HI-TEMP 1200 Coating Under Insulation

Pulsed Eddy-Current (PEC) Inspection through Insulation

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION

SPECIFICATION GUIDELINES FOR THE USE OF CRYOGEL Z ON COLD PIPING AND EQUIPMENT

SECTION MECHANICAL INSULATION

Division 15 INSULATION Section 15100

ProRox. ProRox NCS Industrial insulation PROVEN METHOD. How to combat Corrosion Under Insulation? RECOMMENDED BY EXPERTS

Northeast Gas Operation School Thursday June 5 th

PERMATHERM, INC. SPECIFICATION FOR CHILLED WATER PIPE INSULATION

SECTION HVAC INSULATION

HVAC Piping Insulation- FIBERGLAS Insulation

OH&S practices as a cause of corrosion under insulation?

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

University of Delaware

Assessment Schedule - TS.5

Evolution of an LNG Terminal: Senboku Terminal of Osaka Gas. Toshiro Otsuka Senboku LNG Terminal Osaka Gas Co., Ltd.

Techno-Economics. Steam Tracing & Auto-Trace (Electric Tracing). Case Studies 1 to 5 Pipe Tracing

INSULATION & EFFICIENCY

ITW INSULATION SYSTEMS

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

ITW INSULATION SYSTEMS

Innovative Coatings Technologies

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

REAFFIRMATION WITH EDITORIAL REVISION October Process Industry Practices Insulation. PIP INEG1000 Insulation Design Guide

Revision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

Mechanical Integrity and Carbon Steel Refrigerant Piping

STATE UNIVERPROGRAM DIRECTIVES

Stayflex Systems FREQUENTLY ASKED QUESTIONS

Protection of Corrosion under Insulation using Vapor Phase Corrosion Inhibitors, Corrologic V p CI-658

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

This Design guideline contained herein includes the requirements for mechanical insulation at The University of Texas at Austin

PRODUCT CATALOGUE. for. smartphone / website / digital edition / BOOK / ipad / GPS

Emperor Penguins and Efficient Buildings. Resisting frigid temps with thermal breaks.

White Paper. By Jeffrey T. Kochelek and Adam H. Hilton V.1.0.0

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

SUPERIOR CAL-SHIELDS Features & Benefits FAST

Cold Spray Coatings for Prevention and Mitigation of Stress Corrosion Cracking

FOAMGLAS INSULATION SPECIFICATION

SECTION MANUFACTURED ROOF EXPANSION JOINTS

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

PERMATHERM PIPE INSULATION PRODUCTS

APPENDIX B, TABLE B.2.4 DISPOSITION OF NEI COMMENTS ON CHAPTER V OF GALL REPORT

Installation Guidelines for ITW Insulation Systems Metal Jacketing Used on Insulated Pipe

079 Quick Installation Guide

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

Petrochemical. System Guide. Coatings, Linings, and Fireproofing

Transcription:

CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE Prepared By: Mohammed AbuALRub SAFCO Reliability Dept. December 10, 2015

CONTENT Introduction CUI PhenomenaMain components of the cold insulation system Wet Insulation Cyclic Temperature Effect CUI contributing Factors Design of cold insulation system Application of cold insulation systems Common locations susceptible to CUI Systems susceptible to CUI CUI Inspection Methods & program CUI cases Conclusion Remarks No. 1

INTRODUCTION In the process industry and petrochemical plants several hundreds of pipe lengths, equipments, storage tanks an assets are insulated for process requiremnts. The common types of insulation systems are: Hot thermal insulation Cold thermal insulation In additional to the thermal insulation systems, fire proofing also present in plant assets as per requirements. CUI is real threat to the parent metal of insulated equipments, pipelines and structures which are operating in the CUI susceptible temperature range [(-4) 120] C. No. 2

CUI PHENOMENA Corrosion Under Insulation (CUI) is a localized corrosion occurring at the interface of a metal surface and the insulation on that surface. CUI can be a particularly severe form of corrosion because of the difficulty in detection due to the corrosion occurring beneath the insulation. The most common forms of CUI are localized corrosion to the CS materials and chloride SCC of austenitic SS Thermal insulation and fire proofing provide the cover for the corrosion to hide underneath. The insulation cover may trap moisture or spilled chemicals which can form corrosive media that attacks the parent metal. Because the corrosion is hidden from sight, the phenomena often progress undetected for long time. No. 3

CUI PHENOMENA Moisture combined with Oxygen is the largest contributing factor to corrosion. The closed environment of the insulation material over the metallic component, creates conditions that encourage build up of moisture and initiating corrosion reaction. In general, corrosion is in the form of pitting type corrosion No. 4

THE WET INSULATION Promote corrosion and provide the cover for corrosion to hide underneath. Right environment for corrosion to start & grow in. Spread corrosion to other areas. Trap the moisture / spilled chemicals. The corrosion is often more severe because the insulation material not allowing evaporation and the insulation acting as a carrier. Moisture occurring in one area moves through the insulation to another area causing the corrosion to spread more rapidly. Acids, acid gases and strong bases like caustics and salts are aggressive corrosive agents and will accelerate existing CUI. No. 5

CYCLIC TEMPERATURE EFFECT Cyclic temperatures that vary from below the dew point and above the ambient temp. Wet/dry cycle develops water condensation, then baked off during hot/dry cycle. Transition from cold/wet to hot/dry includes intermittent period of damp/warm condition with attendant high corrosion rate. No. 6

CUI CONTRIBUTING FACTORS Inadequate design of weather barrier Improper application of insulating system Improper installation of weather barrier Workmanship Physical abuse Insufficient stage inspection Insufficient maintenance No. 7

DESIGN OF COLD INSULATION SYSTEM Temperature of the product Design life Protective coating Insulating material & its thickness Sealing of the gaps Vapor barrier Metal jacketing Water proofing for metal jacketing No. 8

MAIN COMPONENTS OF THE COLD INSULATION SYSTEM Preformed Polyurethane Foam with pre-laminated vapor barrier Jacketing Cover Material. Fastening material Joint sealer. Cradle wooden block or urethane block for supports. Stainless steel band and clips No. 9

COLD INSULATION SYSTEM No. 10

APPLICATION OF COLD INSULATION SYSTEM Blast clean the surface Apply protective coating Coat joints with adhesive material Attach insulating material Attach vapor barrier Metal jacketing Water proofing No. 11

SPECIAL CARE FOR INSULATING Valves Flanges Expansion bellows Nozzles Pipe supports Hangers Attachments No. 12

COMMON LOCATIONS SUSCEPTIBLE TO CUI All penetrations or breaches Dead legs Pipe hangers & supports Valves & fittings Pipe support Steam tracer tubing penetration Termination of insulation at flanges Damages or missing insulation jacketing Low points in the piping system No. 13

SYSTEMS SUSCEPTIBLE TO CUI CS piping systems operating between [(-4)- 120] C. CS piping systems operate in service above 120 but are intermittent service. Austenitic SS piping systems that operate between (60 204) C are susceptible to chloride SCC Vibrating piping systems that cause damages to the insulation jacketing Dead legs and attachments systems Areas exposed to mist overspray Areas exposed to steam vents Areas exposed to deluge systems Areas subject to process spills, ingress of moisture or acid vapors Steam traced piping systems that might experience tracing leaks Pining with deteriorated coating and or wrapping No. 14

CUI INSPECTION METHODS External Visual Surveillance External damages Visible wet spots Random stripping of insulation NDT Methods Profile Radiography (RT) Infrared to detect Damp Spots Pulse Eddy Current (EC) No. 15

CS AFTER INSULATION STRIPING No. 16

CS AFTER INSULATION STRIPING No. 17

CS LINE AFTER INSULATION STRIPPING No. 18

CONCLUSION REMARKS 1) Intermittent service temperature in the CUI susceptible range highly promotes CUI attack. 2) Regular inspection program of insulated piping and equipment, external visual surveillance. 3) Important factors: Proper design and application of the insulation system. Stage wise inspection of the insulation system during application. Proper coating system of the substrate. Inspection of insulation repaired locations 4) Workmanship is essential factor for healthiness of the insulation system. No. 19

20 No. 20