Evaluation copy. Chloride and Salinity. Computer INTRODUCTION

Similar documents
Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

Total Dissolved Solids

Biochemical Oxygen Demand

Vernier Software & Technology

FINAL REPORT A Mini Grant for Redesigning Lab Experiments for "Chemistry in Society" (ACHM 105) - A General Education Course Kutty Pariyadath

Ocean Water. Evaluation copy

A Water Field Study. Table 1: Water Temperatures of Selected Rivers Site Season Temperature ( C)

Water Quality Temperature

Acid Rain and Its Effect on Surface Water. Evaluation copy. Figure 1: Typical rain ph in United States.

Dissolved Oxygen. LabQuest INTRODUCTION

LabQuest INTRODUCTION

Turbidity. LabQuest INTRODUCTION

Cell Respiration (Method 1 CO 2 and O 2 )

Acid Rain. Evaluation copy. Figure 1: Typical rain ph in United States.

Evaluation copy. Energy Content of Fuels. computer OBJECTIVES MATERIALS

Dissolved Oxygen Probe (Order Code: DO-BTA)

Solar Homes. Evaluation copy. empty bottle with screw-on cap

An Insulated Cola Bottle

Electrical Conductivity/Salinity Fact Sheet

To whom it may concern, February 21, 2011

seven mm screw top bottles Vernier computer interface shallow pan Vernier Dissolved Oxygen Probe scissors Logger Pro

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

How Salty Is Our Water?

Module 2, Add on Lesson Conductivity Sensor. Student. 90 minutes

Module 2, Add on Lesson Conductivity Sensor. Teacher. 90 minutes

Evaluation copy. Biodiversity and Ecosystems. computer OBJECTIVES MATERIALS PROCEDURE

Evaluation copy. Energy Content of Fuels. computer OBJECTIVES MATERIALS

Forensics with TI-Nspire Technology

Salinity in Seawater

Salinity Sensor PS Salinity Sensor Probe. Salinity Sensor Probe, 10 X, Conductivity/Temperature PASPORT Extension Cable

HYDROLOGY INVESTIGATION Electrical Conductivity. What is Conductivity?

Direct ISE Method Method to 4.00 mg/l NO 3 N Nitrate ISE

Write your own lab Spectrophotometry/Colorimetry

A natural impurity in water. The test will measure the amount of free oxygen "gas" dissolved in your water sample in ppm (mg/l).

Evaluation copy. Energy Content of Fuels. computer OBJECTIVES MATERIALS

Salinity. sulphate, SO 4

Direct ISE Method Method to 10.0 mg/l F Fluoride ISE

Collecting a Surface Water Sample

Evaluation copy. Managing Garden Soil Moisture. Experiment OBJECTIVES MATERIALS PROCEDURE

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

Know What You re Monitoring! Since not all of us are water chemists, here is a brief understanding of what your different tools measure

Collecting a Surface Water Sample

AdOc 4060 / 5060 Seawater Salinity. CTD (Conductivity / Temperature / Depth) 2013 Spring Chris Jenkins

Oceanopgraphy: 3014 lab 6 Experiments:

Finding the Salt Front

Boiler Water No.2 Test Kit Instruction Manual

INTRODUCTION TO ELECTROCHEMISTRY: CURRENT, VOLTAGE, & BATTERIES. Introduction. Electrochemistry Revised 4/28/14

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

COMPOSITION OF SEAWATER

Laboratory Exercise #6 - Introduction to Oceanography

STUDENTS 2 SCIENCE Virtual Lab Experiment Precipitates

Freezing and Melting of Water

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right

Water Analysis Kit for Home Brewers

Demonstration of Relationship between CO2 and ph Instructions

On-Site Generation Of Disinfectants

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

CBF Water Quality Interactive Map

Water Monitoring in Spa Creek: A Summary

Environmental Science

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

Instrument Adapters Light shield DR 6000, DR 5000 DR 3900 LZV849 DR 3800, DR 2800 LZV646 DR or (A)

Experiment 3: Determination of an Empirical Formula

HOBO U24 Conductivity Logger (U24-00x) Manual

Tap Water Analysis by Atomic Absorption and Ion Chromatography Michelle Youn Chem. 31: Inorganic Quantitative Analysis Section 6

Sampling Day Activities

Cartridge Prep Manual

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

Color, True and Apparent, LR

HI Seawater Refractometer INSTRUCTION MANUAL

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

Advanced Water Treatment (DESALINATION) PART 1. Instructors : Dr. Yunes Mogheir Dr. Azzam Abu Habeeb. Page 1

INTERDISCIPLINARY INVESTIGATION (IDI)-LAB LABORATORY HANDOUT

Typical Experiments. How it Works

EVENT: Perform the following steps of a BOD analysis using the YSI ProOBOD Optical BOD probe.

Eutrophication: Too Much of a Good Thing?

Odyssey Conductivity & Temperature Logger.

APPENDIX A LPR STANDARD OPERATING PROCEDURE

Introduction to the marine environment

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

The total amount in grams of solid material dissolved in 1 kg of seawater.

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

Salinity in the Central Valley

Water Quality Index For Assessment Of Water Quality In South Chennai Coastal Aquifer, Tamil Nadu, India

Operating Manual for Digital ph-meter GPHR 1400

Water Desalination and Its Techniques

Introduction The Van London Co. Cadmium Ion Electrode is used to measure Cadmium ions in aqueous solutions.

200 Series Benchtop ph/cond. Meter. Instruction Manual

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb

Chapter Overview. Water molecule. Atomic Structure. Hydrogen Bonding. Hydrogen Bonding. CHAPTER 5 Water and Seawater

HI 4105 CARBON DIOXIDE. Instruction Manual HI Carbon Dioxide Ion Selective Electrode

Experimental Procedure. Lab 402

HOBO U24 Conductivity Logger (U C) Manual

HOBO U24 Conductivity Logger (U C) Manual

Physical and Chemical Monitoring

The effect of Hilti / Salahi Recharge Dam in Batineh Area, Sultanate of Oman on the Quality of Groundwater Using GIS

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

Palintest TABLET COUNT TESTS TAB.1 INSTRUCTIONS FOR USING THE PALINTEST TABLET COUNT METHOD OF WATER ANALYSIS

Transcription:

Chloride and Computer 15 INTRODUCTION Chloride Chloride, in the form of the Cl ion, is one of the major inorganic anions, or negative ions, in saltwater and freshwater. It originates from the dissociation of salts, such as sodium chloride or calcium chloride, in water. NaCl(s) Na + (aq) + Cl (aq) CaCl 2 (s) Ca 2+ (aq) + 2 Cl (aq) These salts, and their resulting chloride ions, originate from natural minerals, saltwater intrusion into estuaries, and industrial pollution. There are many possible sources of manmade salts that may contribute to elevated chloride readings. Sodium chloride and calcium chloride, used to salt roads, contribute to elevated chloride levels in streams. Chlorinated drinking water and sodiumchloride water softeners often increase chloride levels in wastewater of a community. In drinking water, the salty taste produced by chloride depends upon the concentration of the chloride ion. Water containing 250 mg/l of chloride may have a detectable salty taste if the chloride came from sodium chloride. The recommended maximum level of chloride in U.S. drinking water is 250 mg/l. Sources of Chloride Ions River streambeds with salt-containing minerals Runoff from salted roads Irrigation water returned to streams Mixing of seawater with freshwater Chlorinated drinking water Water softener regeneration is the total of all non-carbonate salts dissolved in water, usually expressed in parts per thousand (1 ppt = 1000 mg/l). Unlike chloride (Cl ) concentration, you can think of salinity as a measure of the total salt concentration, comprised mostly of Na + and Cl ions. Even though there are smaller quantities of other ions in seawater (e.g., K +, Mg 2+, or SO 2 4 ), sodium and chloride ions represent about 91% of all seawater ions. is an important measurement in seawater or in estuaries where freshwater from rivers and streams mixes with salty ocean water. The salinity level in seawater is fairly constant, at about 35 ppt (35,000 mg/l), while brackish estuaries may have salinity levels between 1 and 10 ppt. Since most anions in seawater or brackish water are chloride ions, salinity can be determined from chloride concentration. The following formula is used: salinity (ppt) = 0.0018066 Cl (mg/l) Evaluation copy A Chloride Ion-Selective Electrode can be used to determine the chloride concentration, which is converted to a salinity value using the above formula. can also be measured in freshwater. Compared to seawater or brackish water, freshwater has much lower levels of salt ions such as Na + and Cl ; in fact, these ions are often lower in concentration than hard-water ions such calcium (Ca 2+ ) and bicarbonate (HCO 3 ). Because Water Quality with Vernier 15-1

Computer 15 salinity readings in freshwater will be significantly lower than in seawater or brackish water, readings are often expressed in mg/l instead of ppt (1 ppt = 1000 mg/l). Increased salinity levels have been observed in the lower reaches of the Colorado and Rio Grande rivers, due to return of irrigation water (see Table 1). In these arid regions of the United States, water readily evaporates during irrigation, resulting in high concentrations of salt ions in the water returned to the rivers. is also of interest in bodies of water where seawater mixes with freshwater, since aquatic organisms have varying abilities to survive and thrive at different salinity levels. Saltwater organisms survive in salinity levels up to 40 ppt, yet many freshwater organisms cannot live in salinity levels above 1 ppt. Expected Levels Seawater has a chloride ion concentration of about 19,400 mg/l (a salinity of 35.0 ppt). Brackish water in tidal estuaries may have chloride levels between 500 and 5,000 mg/l (salinity of 1 to 10 ppt). Even freshwater streams and lakes have a significant chloride level that can range from 1 to 250 mg/l (salinity of 0.001 to 0.5 ppt). Table 1: Chloride and in Selected Sites Site (fall season) Chloride (mg/l) (mg/l) (ppt) Columbia River, Newport, WA 1.3 2.3 0.0023 Mississippi River, Memphis, TN 14.1 25.5 0.025 Rio Grande River, San Marcial, NM 56 101 0.101 Rio Grande River, Brownsville, TX 220 397 0.397 Colorado River, State Line, CO-UT 67 121 0.121 Colorado River, Andrade, CA 190 343 0.343 Summary of Methods Method 1: Chloride Concentration and (ISE) A Vernier Chloride Ion-Selective Electrode is used to measure the chloride ion concentration in the water (in mg/l) either on site or after returning to the lab. can be determined using the relationship, salinity (ppt) = 0.0018066 Cl (mg/l). Method 2: Using a Conductivity Probe (Seawater or Brackish Water) A Vernier Conductivity Probe is used to measure the salinity value of the water (in ppt). If salinity values exceed 13 ppt, dilution of samples, as described in the procedure, will be necessary. This method uses the assumption that most of the ions in the solution are noncarbonate salt ions (e.g., Na +, K +, or Cl ), and converts the conductivity reading to a salinity value. 15-2 Water Quality with Vernier

Chloride and Method 1: CHLORIDE CONCENTRATION AND SALINITY (ISE) Materials Checklist computer Low Standard (10 mg/l Cl ) Vernier computer interface High Standard (1000 mg/l Cl ) Logger Pro Very High Standard (20,000 mg/l Cl ) Chloride Ion-Selective Electrode tissues wash bottle with distilled water small paper or plastic cup (optional) Advanced Preparation The Vernier Chloride Ion-Selective Electrode (ISE) must be soaked in the Chloride High Standard solution (included with the ISE) for 15 30 minutes. Important: Make sure the electrode is not resting on the bottom, and that the small white reference contacts are immersed. Make sure no air bubbles are trapped below the electrode. If the ISE needs to be transported to the field during the soaking process, use the Short-Term ISE Soaking Bottle. Remove the cap from the bottle and fill it 3/4 full with High Standard. Slide the bottle s cap onto the ISE, insert it into the bottle, and tighten. Important: Do not leave the ISE soaking for more than 24 hours. Long-term storage should be in the Long-Term ISE Storage Bottle. Collection and Storage of Samples ISE soaking for travel 1. This test can be conducted on site or in the lab. A 100 ml water sample is required. 2. It is important to obtain the water sample from below the surface of the water and as far away from shore as is safe. If suitable areas of the stream appear to be unreachable, samplers consisting of a rod and container can be constructed for collection. Refer to page Intro-4 of the Introduction of this book for more details. Testing Procedure 1. Position the computer safely away from the water. Keep water away from the computer at all times. 2. Prepare the Chloride Ion-Selective Electrode (ISE) for data collection. a. The ISE should be soaking in the High Standard. Make sure that it is not resting on the bottom of the container, and that the small white reference contacts are immersed. b. Plug the ISE Sensor into Channel 1 of the Vernier interface. 3. Prepare the computer for data collection by opening the file 15 Chloride ISE from the Water Quality with Vernier folder of Logger Pro. Water Quality with Vernier 15-3

4. You are now ready to calibrate the Calcium ISE. First Calibration Point a. Choose Calibrate CH1: Chloride ISE from the Experiment menu and then click. b. Type 1000 (the concentration in mg/l Cl ) in the edit box. c. When the displayed voltage reading for Reading 1 stabilizes, click. Computer 15 Second Calibration Point d. If you are testing a freshwater sample, place the tip of the electrode into the Low Standard (10 mg/l Cl ). If you are testing a seawater- or brackish-water sample, place the tip of the electrode into the Very High Standard (20,000 mg/l Cl ). Be sure that the electrode is not resting on the bottom of the bottle and that the small white reference contacts are immersed. Make sure no air bubbles are trapped below the electrode. e. After briefly swirling the solution, hold the ISE still and wait approximately 30 seconds for the voltage reading displayed on the computer screen to stabilize. f. Enter 10 (the concentration of the Low Standard) or 20,000 (the concentration of the Very High Standard), depending on which one you used. g. When the displayed voltage reading for Reading 2 stabilizes, click, then click. 5. You are now ready to collect chloride concentration data. a. Rinse the ISE with distilled water and gently blot it dry. b. Place the tip of the probe into the stream at Site 1, or into a cup with sample water from the stream. Make sure the ISE is not resting on the bottom and that the small white reference contacts are immersed. Make sure that no air bubbles are trapped below the ISE. c. Click to begin data collection. d. Click to begin a 10 s sampling run. Important: Leave the probe tip submerged for the 10 seconds that data is being collected. e. When the sampling run is complete, stop data collection and record the mean chloride concentration value on the Data & Calculations sheet. 6. Return to Step 5 to obtain a second reading. 7. Determine the salinity value of your sample (in ppt). Use this formula to calculate the salinity, based on the chloride concentration, Cl salinity (ppt) = 0.0018066 X Cl (mg/l) Record this value in the Data & Calculations table (round to the nearest 0.1 mg/l Cl ). 15-4 Water Quality with Vernier

Chloride and DATA & CALCULATIONS Method 1: Chloride Concentration and (ISE) Stream or lake: Site name: Site number: Date: Time of day: Column A B Reading Chloride (mg/l Cl ) (ppt) 1 2 Average Column Procedure: A. Record the chloride concentration value (in mg/l Cl ) from the computer. B. Calculate salinity, using the formula: salinity (ppt) = 0.0018066 Cl (mg/l). Field Observations (e.g., weather, geography, vegetation along stream) Test Completed: Date: Water Quality with Vernier 15-5

Computer 15 Method 2: SALINITY USING A CONDUCTIVITY PROBE Materials Checklist computer Vernier computer interface Logger Pro Vernier Conductivity Probe 100 ml graduated cylinder 500 ml bottle with lid wash bottle with distilled water tissues or paper towels 5 ppt salinity standard 10 ppt salinity standard small paper or plastic cup (optional) Collection and Storage of Samples 1. This test can be conducted on site or in the lab. A 100 ml water sample is required. 2. It is important to obtain the water sample from below the surface of the water and as far away from shore as is safe. If suitable areas of the stream appear to be unreachable, samplers consisting of a rod and container can be constructed for collection. Refer to page Intro-4 of the Introduction of this book for more details. Testing Procedure 1. Position the computer safely away from the water. Keep water away from the computer at all times. 2. Prepare the Conductivity Probe for data collection. a. Plug the Conductivity Probe into Channel 1 of the Vernier interface. b. Set the switch on the probe box to the 0-20000 µs range (0-13 ppt salinity). 3. Prepare the computer for data collection by opening 15 Conductivity from the Water Quality with Vernier experiment files of Logger Pro. 4. You are now ready to calibrate the Conductivity Probe. If your instructor directs you to use the calibration stored in the experiment file, then proceed to Step 5. If your instructor directs you to perform a new calibration for the Conductivity Probe, follow this procedure: First Calibration Point a. Choose Calibrate CH1: Conductivity (ppt) from the Experiment menu and then click. b. Perform the first calibration point by placing the Conductivity Probe into the 5 ppt salinity standard. The hole near the tip of the probe should be covered completely. c. Type 5 (the salinity value) in the edit box. d. When the displayed voltage reading for Reading 1 stabilizes, click. 15-6 Water Quality with Vernier

Chloride and Second Calibration Point e. Place the Conductivity Probe into the 10 ppt salinity standard solution. The hole near the tip of the probe should be covered completely. f. Type 10 (the salinity value) in the edit box. g. When the displayed voltage reading for Reading 2 stabilizes, click, then click. h. Rinse the electrode with distilled water and gently blot it dry with a tissue. 5. You are now ready to collect salinity concentration data. a. Place the tip of the electrode into a cup with sample water from the body of water you are testing. The hole near the tip of the probe should be covered completely. b. Monitor the salinity concentration value in the meter. If the value is less than 13 ppt (the upper range of the Conductivity Probe), record this value on the Data & Calculations sheet. If you did a 1/4 dilution of the sample, be sure to multiply this value by 4! If the salinity value is greater than 13 ppt, go to Step 7. 6. Repeat Step 5 to obtain a second reading. 7. If your salinity value is greater than 13 ppt, then the sample had a salinity value that is beyond the upper range of the Conductivity Probe. You will need to dilute the sample to a salinity value that is within the range of the probe. To do this, a. Use a graduated cylinder to add 100 ml of the water sample to a 500 ml bottle. b. Add 300 ml of distilled water to the sample in the bottle, screw the lid on, and shake it well. c. Important: The sample has been diluted by a factor of 100 / 400 or ¼. Any salinity measurements made on this sample will have to be multiplied by a factor of 4 to account for this dilution. d. Repeat Step 5 to obtain a second reading. Water Quality with Vernier 15-7

Computer 15 DATA & CALCULATIONS Method 2: Using a Conductivity Probe Stream or lake: Time of day: Site name: Site number: Date: Column Reading A (ppt) 1 2 Average Column Procedure: A. Record the salinity concentration as determined by interpolation of the calibration curve. Field Observations (e.g., weather, geography, vegetation along stream) Test Completed: Date: 15-8 Water Quality with Vernier

Vernier Lab Safety Instructions Disclaimer THIS IS AN EVALUATION COPY OF THE VERNIER STUDENT LAB. This copy does not include: Safety information Essential instructor background information Directions for preparing solutions Important tips for successfully doing these labs The complete Water Quality with Vernier lab manual includes 16 water quality tests and essential teacher information. The full lab book is available for purchase at: http://www.vernier.com/cmat/wqv.html Vernier Software & Technology 13979 S.W. Millikan Way Beaverton, OR 97005-2886 Toll Free (888) 837-6437 (503) 277-2299 FAX (503) 277-2440 info@vernier.com www.vernier.com