Tri-Star MAX Spill Containment System - 7' x 16' x 9" Panel

Similar documents
Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Keep workers and products out of harms way. STRUCTURAL GUARDS

Captor Containment. DOUBLE WALL TANK SYsTEMS.

Captor Containment DOUBLE WALL TANK SYSTEMS.

INSTALLATION MANUAL KOCH

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Poly Sumps for IBC Totes

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

Raised Basement. Mechanical Installation Guide

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

Abstract. 1. Introduction

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

Chlorine Contact Basin at Keegan s Bayou WWTP, Houston, TX

Architectural Roof and Wall Products Guide Specifications

SRP-AirOutshield UV Issued:

ThermaSteel Corporation ASSEMBLY MANUAL

CITY OF THOUSAND OAKS APPROVAL CHECKLIST FOR REFUSE/RECYCLING ENCLOSURES

Coakley Bay Association

SECTION 07530CP EPDM MEMBRANE ROOFING

High Performance Insulating Concrete Form

Continuous Insulation Systems for Exterior Walls

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

LIST OF DRAWINGS PLAN TITLE

Section X - Miscellaneous

SECTION IMPACT RESISTANT WALL PROTECTION

GRATING PRODUCTS. PROGrid and PROGrate

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Section 32 - Miscellaneous

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Architectural Roof and Wall Products Guide Specifications

Guardrails. A Safe Workplace

FOLDING CONTAINER HOUSE: AMH-4000 SERIES GENERAL AMH-4120 DIMENSIONS AND WEIGHT PICTURES:

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Central Station Air Handler Specification

The Ton-Tel Weighbridge

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Utility Cabinet System (UCS)

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

SECTION Motor Operated Horizontal Sliding Sound Control Door

Section 7: Specifications

MDS TL5 Minimum Deflection Systems

Secure Storage On Demand

Vehicle Scales. Rugged Concrete Weighbridge Composite design for long life

Guardrails. A Safe Workplace

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

CONTAMINATED WASH RUN-OFF

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

Rapid Deployment Shelter System User Manual

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

Equipment Catalog. Most Cost Effective Longest Lasting. Manufactured by

Installation Guide and Safety Manual

HOTEL SPECIFICATION SECTION 08100

DALAL FLAT PACK MODULAR UNITS

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

Architectural Wall Products Guide Specifications

Residential Products

INSTRUCTIONS AND GUIDELINES

A. Provide and install a factory made, wood framed, storage building. B. Building Construction Type: IBC Type V-B Wood Frame.

Product Guide Specification

SECTION PRE-ENGINEERED METAL BUILDING

SECTION METAL DOORS & FRAMES

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

DESIGN AND CONSTRUCTION STANDARDS November 2010

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

DESIGN AND CONSTRUCTION STANDARDS April 2011

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

Attachment A-Flagpole(s) Specifications

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

8497 MFab BBU broch. 10/19/05 2:06 PM Page 1 APPLICATION 4 FT TYPICAL Bulk Bag Unloaders

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

Transparent Fiberglass Tanks

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

SOLAR. Superior productivity. Superior performance.

Light-Metal Roof Edge, Raised

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

3' COMMERCIAL RIB PREFORMED METAL SIDING

Student Services & Classroom Addition

Rapid Clamp EUROBUYSERVICES EBS

Vortex Filters. Conservation Technology

CW Series FLOORSCALES. ISO 9001:2000 Registered

Roof Drains. The Hole Story

Preassembled steel stairs with concrete-filled treads.

Contents. 4 Recreate scenarios. 10 Entry Panels 12 PPS Ballistic 14 PPS Container Packs. 16 CQB Training House 18 Accessories 19 Contact

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

Design & Construction Standards, Revised January

SECTION WELDED STEEL WATER STORAGE TANKS

(4) Production inspection is the inspection that must initially be conducted on each newly manufactured IBC.

Transcription:

Export date: Sun Dec 10 6:41:03 2017 / +0000 GMT Tri-Star MAX Spill Containment System - 7' x 16' x 9" Panel SKU: CST-MAX071609 Product Categories: Tri-Star MAX - Fuel Tank Containment - Tanker Containment Product Page: https://containmentcorp.com/product/tri-star-max-spill-containment-system-7-x-16x-9-panel/ Product Description Tri-Star MAX Spill Containment System - 7' x 16' x 9" Panel Our surface-mounted, modular, drive-in containment system has standardized widths for tankers of 13' wide and 16' wide and is assembled with 7' length panels. Designed for fuel or chemical trucks with large containment requirements. The Tri-Star MAX's modular design supports custom lengths, and allows this heavy-duty steel system to be shipped over the highways or even overseas in shipping containers! Our 16' wide system is ideal for Fuel Tanker Containment. Please visit our Tri-Star MAX page for Fuel Tankers to view our 42' x 16' x 9" Tri-Star MAX System for Fuel Tankers. For other size tankers our minimum lengths for systems is 21' or 3 panels and can be expanded as desired based on vehicle size and capacity requirements. Constructed of heavy plate steel panels, and featuring the proven tri-linear wall design, thousands of Tri-Star MAX systems have been employed in military applications for more than ten years now without a single reported wall failure. Page 1/18

Export date: Sun Dec 10 6:41:03 2017 / +0000 GMT Each panel is fully encapsulated in a heavy fiberglass (with glass mat) protective coating, many times thicker than any paint, to provide maximum protection over the long haul. The sump is comprised of horizontal panels with overlapping seams which are bolted together to compress a gasket/caulk sealant for a watertight surface. Various gasket/caulk materials can be used for compatibility with various fuel and chemical exposures. Each system is completed with drain ports in all four corners, and filter berms with ball valves for rainwater management. Systems include tie-downs to anchor the structure to the substrate and Line-of-Sight Poles to assist drivers entering and exiting the systems. Page 2/18

Export date: Sun Dec 10 6:41:04 2017 / +0000 GMT Page 3/18

Export date: Sun Dec 10 6:41:05 2017 / +0000 GMT Tri-Star MAX's modular construction allows the disassembled panels to be stacked for shipment over the highways or containerized for shipment overseas. Page 4/18

Export date: Sun Dec 10 6:41:05 2017 / +0000 GMT Page 5/18

Export date: Sun Dec 10 6:41:06 2017 / +0000 GMT Ramps: The interior half of the ramp system is integral to the end panel. The outside half of the ramp system bolts onto the assembled structure. Page 6/18

Export date: Sun Dec 10 6:41:06 2017 / +0000 GMT Ramps come in three standard lengths: X Ramps extend out for the ramp peak 3ft in both directions, 6ft total. These ramps are sufficient for most military tanker trucks. XX extends out from the ramp peak 5ft in both directions, 10ft total. Large AF R-11 refuelers and most large commercial refuelers are comfortable with this ramp. XXX Ramp extends out from the ramp peak 8ft in both directions, 16ft total. This ramp is occasionally used for very large refuelers, or situations where site conditions dictate a longer ramp. Page 7/18

Export date: Sun Dec 10 6:41:07 2017 / +0000 GMT Page 8/18

Export date: Sun Dec 10 6:41:07 2017 / +0000 GMT Tri-Star MAX's modular construction allows the disassembled panels to be stacked for shipment over the highways or containerized for shipment overseas. Page 9/18

Export date: Sun Dec 10 6:41:08 2017 / +0000 GMT All Tri-Star MAX Truck Containment Systems come with up to four large (1-1/2 ) female threaded Drain Ports. Generally located in each corner. The open floor plan allows for rainwater to flow freely to the lowest corner. The Drain Ports can be secured with a Filter Berm on the inside of the drain, and a Ball Valve on the outside, to safely control rainwater releases from the system Page 10/18

Export date: Sun Dec 10 6:41:08 2017 / +0000 GMT Half inch thick steel tie-downs are used at every joint to secure the system to the substrate. Understanding that a 42' long full size Tri-Star containment system with ramps at either end weighs approximately 13,000 lbs. and isn't going anywhere Page 11/18

Export date: Sun Dec 10 6:41:09 2017 / +0000 GMT Page 12/18

Export date: Sun Dec 10 6:41:10 2017 / +0000 GMT System is completed with Line-of-Sight poles; break-away design that gives the driver a visual point of reference entering and leaving the system. Page 13/18

Export date: Sun Dec 10 6:41:10 2017 / +0000 GMT Page 14/18

Export date: Sun Dec 10 6:41:11 2017 / +0000 GMT Need additional capacity Plumb systems together to share capacity. The five systems pictured to the left were plumbed together to create more than 14,000 gallons of surface containment! Page 15/18

Export date: Sun Dec 10 6:41:11 2017 / +0000 GMT Page 16/18

Export date: Sun Dec 10 6:41:12 2017 / +0000 GMT Add a Tri-Star Canopy for protection from the elements. The canopies are surface mounted; no ground penetration. A heavy duty anchor is attached to the rugged tri-linear sidewall, and the canopy poles are secured to these anchors. Designed to withstand winds to 80 mph. We now offer surface mounted (similar to canopy above) steel building! These can be ordered complete with roll-up doors and man-doors. See additional images of Tri-Star Tanker Truck Containment in our photo gallery! Product Attributes - Dimensions: 7 x 16 x 9 cm Product Gallery Page 17/18

Export date: Sun Dec 10 6:41:12 2017 / +0000 GMT Page 18/18