Degasification of Boiler Feed Water with Liqui-Cel Membrane Contactors

Similar documents
Quality water. Powerful results.

Quality water. Powerful results.

Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager

Condensate System Troubleshooting andoptimization

Optimize Your Boilers. Kevin Brady Merlo Energy

effective deoxygenation by a hybrid process combining gas transfer membranes with catalytic oxygen reduction

Challenges in Industrial Waste Heat Recovery. Texas Technology 2006 Showcase Tony Dafft December 6 & 7, 2006

Boiler and. steadily increases while the supply decreases energy

The Cost of Improper Water Treatment

Boiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE

Optimizing Steam and Cooling Systems for Reliability and Sustainability. Presented By: Kevin Emery

Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies

Boiler Energy Efficiency & Overview of Economizers

Introduction. Food & Dairy Plants typically employ psig steam generated by firetube boilers. First cost of a steam boiler plant is exceeded

Centerpoint Energy. Energy Efficiency & Technology Conference. Steam and Process Heat Recovery. May 23, 2017

Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies

PMAX Cycle Isolation Module Greg Alder

Steamate* technology. superior protection against condensate system corrosion. Water Technologies & Solutions technical bulletin

Page of ENGINEERING DATA - HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine

Energy Efficiency Strategies Waste Heat Recovery & Emission Reductions

Downsizing a Claus Sulfur Recovery Unit

Maxi-Therm Since 2002, throughout North America, Maxi-Therm has been manufacturing innovative packaged solutions for informed specifiers.

Brian Carrico, AICP, Senior Project Manager/Environmental Planner

Steam Basics Armstrong International, Inc.

Steam System Energy Efficiency Opportunities and Waste Heat Recovery Keith McBrien GDS Associates

ENGINEERING DATA HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS

NIPPON PAPER RO SYSTEM + 2 Others

Treatment Technologies

Water Treatment Program. Training Manual

Cannon Boiler Works. Boiler Heat Recovery History and Recent Advances. Serving the steam and process industries for more than 35 years.

Energy Efficient. & Cost Saving. Continuous Boiler Blowdown Package Heat Recovery Systems. 20 Models from 1,200 pph to 50,000 pph Capacity

Miura Steam is Engineered for Greater Efficiency, Lower Costs.

Reverse Osmosis Technology

BESTPRACTICES STEAM PROGRAM STEAM TOOLS SPECIALIST QUALIFICATION TRAINING PREREQUISITE STUDY GUIDE (1/12/2004)

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

Central Heating Plants EU 311

SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS

Delayed Coker Blowdown System Water Reuse

Boiler/Cooling Water Processes and Parameters

Water supplied by Marafiq does not meet the process requirements.

KEYWORDS: Deaerator, Condensate, Oxygen Removal, Boiler Feed Water, Heater, Water Treatment

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc.

PRODUCT DESCRIPTION PARAMETERS

Hydrazine, sodium and dissolved oxygen measurement The power of boiler chemistry

BOILER WATER TREATMENT TECHNOLOGY. DSS HEAD OFFICE - SERPONG May 2008

Introduction to Condensate Recovery

Item Hydrogen Gas Plant

Plant Utilities and Energy Efficiency CH505

Oxidation And Degradation Products Of Common Oxygen Scavengers

We have softening plant for boiler so water treatment chemicals is not require. We used 90 % condensate water so no need of any chemicals treatment

Mobile Water Services. Emergency, Planned and Multi-Year Water Treatment WATER TECHNOLOGIES

rios Water Purification system The standard for laboratory-grade water

Taravosh Jam Design & Engineering Co.

VONTRON INDUSTRIAL MEMBRANE ELEMENTS ULP SERIES RO MEMBRANE ELEMENTS

4HE ", -ICRO #ONTROLLER "OILER #ONTROL 3YSTEM. Miura Gas-Fired/ Low NOx LX Series High Pressure Steam Boiler. On-Demand Steam Solutions

40 MIGD potabilization plant at Ras Laffan: design and operating experience

40 MIGD potabilization plant at Ras Laffan: design and operating experience

Using Ski Slopes to Capture and Mix Oxygenated Water to Improve the Efficiency of a Condensate H 2 S Abatement System at Aidlin Power Plant

San Joaquin Valley Unified Air Pollution Control District Best Performance Standard (BPS) x.x.xx

by: Steven M. Puricelli and Ernesto Vera-Castaneda MECS, Inc USA

Treatment Technologies

The material balance equations, after introducing the known values for the variables, are:

Saving energy - reducing costs - protecting the environment Energy, cost and emission-saving solutions for shell steam boiler systems

VVER-440/213 - The reactor core

BOILERS. Outline. Introduction. Types of Boilers. Assessment of a Boiler. Energy Efficiency Opportunities 2/16/2014

1000 GPD Marlin Reverse Osmosis Instruction & Owner s Manual

News. Power Generation 11. ph Control Reduces Acid Consumption in Neutralization Process up to 90 % Perspectives in Pure Water Analytics THORNTON

Western BLRBAC Review/Refresher of Tappi Water Quality Guidelines and Contamination Procedures for mill boilers operating on high purity water

Boiler Water Treatment Design: The 5 Biggest Mistakes

Energy Efficient Industrial Systems: Realizing the Potential. International Energy Conference. Vienna, Austria June 2009

ES Fluid & Thermal Systems Page 1 of 6 STEAM TURBINE LABORATORY

Energy Conservation Preventive Maintenance

Modeling Techniques for Increased Accuracy

Appendix A. An Introduction to Steam Turbine Selection

Cooling tower efficiency U2 Eco-efficiency resources for the food processing industry

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER

Experience In Motion. SIHI Gas separation by using membranes

BOILER FEED WATER AND ITS TREATMENTS

STATE OF ILLINOIS. R. W. Lane. Issued by. Department of Registration and Education C. HOBART ENGLE, Director

Boilers & Fired Systems. Clean Coal Technology Dr. Tanveer Iqbal

Thermal Distribution in District Energy and Cogeneration Systems

7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS

NALCO BT-28 Condensate Corrosion Inhibitor

percent hours of the year heat rejected to loop percent hour building load on loop, Btuh percent hour building load on loop, Btuh

SUGAR INDUSTRY TECHNOLOGISTS MEETING 2000

DW Module 23: Organic Removal Answer Key

Chemistry of Petrochemical Processes

Boiler Water Treatment

POWER PLANT- BOILER OPERATIONS SIMULATOR

Process Total Organic Carbon Analyzer

Exhaust Heat Recovery Systems

Thermal & Fluids PE References Exam Errata

Miura Steam is Engineered for Greater Efficiency, Lower Costs.

Solus* AP - advanced boiler all-polymer internal treatment technology

For Condensing Economizers ENBRIDGE MAY Topics

Training Fees 3300 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch

Guide to Optimal Steam Generation

27 th ANNUAL WATEREUSE SYMPOSIUM CHALLENGES OF HIGH-SULFATE WASTEWATER RECYCLE. Abstract. Introduction

OPERATING PARAMETERS Reliable Means to Continuously Monitor Facility Performance

AN INTRODUCTION HARFST AND ASSOCIATES, INC.

Transcription:

Degasification of Boiler Feed Water with Liqui-Cel Membrane Contactors Author: Fred Wiesler, Membrana. Background Proper treatment of boiler feed water is an important part of operating and maintaining a boiler system. As steam is produced, dissolved solids become concentrated and form deposits inside the boiler. This leads to poor heat transfer and reduces the efficiency of the boiler. Dissolved gasses such as oxygen and carbon dioxide will react with the metals in the boiler system and lead to boiler corrosion. In order to protect the boiler from these contaminates, they should be controlled or removed. There are several different technologies that are widely used in the industry for removing these contaminants. Dissolved solids can be removed with reverse osmosis membrane and ion exchange systems. Dissolved gasses have historically been removed using forced draft degasifiers, chemical agents and steam deareators Recently Membrane Contactors have been utilized to remove the dissolved gasses in boiler feed water. Membrane Contactors are widely used in the semiconductor, power, pharmaceutical and other industries to control dissolved gasses in water systems. Their use in boiler feed water degasification systems has grown steadily since the development of new industrial grade devices. Membrane Contactors are constructed using microporous hydrophobic membranes. The membrane is used to bring a gas and liquid in direct contact without mixing. Contactors operate by lowering the pressure of gas in contact with the liquid to create a driving force to remove the dissolved gasses from the water. They are highly efficient, compact and can be used inline under pressure. Chemical Treatment Chemical treatment is widely used to control dissolved oxygen in a boiler. The cost of operating a chemical treatment program consists of chemical costs and blow down costs. As the water is converted to steam, non-volatile compounds in the boiler feed water are concentrated inside the boiler. Periodically the water in the boiler must be flushed out to remove these compounds. They are flushed out of the boiler in a process called blow down. Any chemical that is added to the water can increase the frequency of blow down. If the blow down frequency is increased or decreased this will impact the operating cost of the boiler. The cost of blow down can be broken down into two costs. Water and steam that is purged from the boiler during blow down is sent to drain. This water must be

replenished by fresh makeup water and there is a cost associated with it. The second cost is a heat or energy cost. The water blow down from the boiler is hot. It is replaced with cold water that must be reheated in order to produce steam. The energy cost can be calculated by looking at the energy needed to heat the water back to the temperature of the steam produced by the boiler. Chemical Costs In smaller low-pressure boilers (<10000 lbs/hr and < 50 psig), chemical treatment alone may be utilized; for larger high-pressure boilers a combination of steam deareation and chemicals is most often used. For ease of calculation, a small low-pressure boiler using a chemical program only is evaluated. These same calculations can be used to evaluate boilers that use steam deareation. When evaluating a deareator, the cost of operation should also be included. Details of the steam deareator operations can be obtained from the supplier. The operating cost of the steam deareator can be estimated by calculating the extra feed water required to operate the deareator and the energy loss associated with venting the steam deareator. Chemical Dosage In practice, 10 ppm of pure sodium sulfite is needed to remove 1 ppm of oxygen from water. One ppm of sodium sulfite equates to 8.3 lbs per million gallons of water. The amount of dissolved oxygen in the water varies with the water temperature. If we assume that if 10 ppm of dissolved oxygen is dissolved in the water, 83.0 lbs of sodium sulfite will be required per million gallons of water. In order to calculate the chemical costs the price of sodium sulfite per pound can be multiplied by the above relationship. Chemical cost (dollars/gallon*ppm O2) = (688) 83.0 lbs of sodium sulphite 0. 5dollars 1,000,000 gallon ppm O2 lbs sodium sulfite The feed water flow rate is the amount of water that is added to the boiler. The feed water rate is equal to the boiler capacity + water loss in blow down condensate return. (34) Feed water flow rate (lb/hr)= lbs boiler capacity hr [ ] 100 Blowdown rate 100 x (100-condensate return) 100 (22)

The chemical cost is directly associated to the gallons of water treated and the inlet dissolved oxygen level in the feed water. Chemical cost (dollars/year)= Feed water Flow rate lbs 0. 11993 gal hr lb Hours of operation hr year Chemical cost dollars ppm O2 gal ppm O2 Blow Down Costs The blow down cost has two components. The costs associated with water loss and the energy costs associated with heating fresh feed water. Water Costs The water cost can be calculated by multiplying the amount of water lost during blow down by the water costs. (48) Blow down flow rate (lbs/hr)= Boiler Capacity lbs hr [ 100- blowdown ] 100 rate lbs - Boiler Capacity hr Blow down Water costs (dollars/yr)= Blow Down lb 0.1193 gal dollars flow rate water ts hour lb gal cos Operating hr [ yr] time Energy Costs Since the feed water is at 60F and must be heated in the boiler, heat must be added to the water. The energy costs associated with heating the water can be estimated by calculating the extra energy needed to heat the feed water. The difference in enthalpy of the steam and the feed water is essentially the difference in the heat content of the feed water and steam in the boiler. The energy costs can be calculated by dividing the fuel cost by the energy content of the fuel. (121) The enthalpy of the water can be found in steam tables. The enthalpy of water at 60F is 28 BTU/lb. The enthalpy of steam at 50 psig is 297 BTU/lb.

Fuel costs (dollars/year)= Blow down flow rate lb hr Operating time hr BTU Energy dollars [ ] yr Enthalpy Boiler lb Cost BTU Efficiency Example Calculation Using Membrane Contactors Membrane Contactors can be used to remove the dissolved oxygen from water. By removing the dissolved oxygen the volume of chemicals added to the boiler will be reduced. By reducing the chemicals added to the boiler the frequency of blow down can be potentially reduced. The example below compares operating costs of two systems. One system is a chemical only treatment system with a blow down rate of 10%. The other system assumes that the oxygen content of the feed water is reduced to 0.5 ppm and that the blow down rate can be reduced to 5% due to the reduction of chemicals in the boiler. (146) The boiler specifications used in this example are for reference only and used so actual calculations can be shown. These calculations can be modified in order to apply them to boilers with different operating conditions. Boiler Operating Details Chemically Treated Degassed Feed Water Feed Water Boiler capacity 10,000 lb/hr 10,000 lb/hr Pressure 50 psig 50 psig Efficiency 80% 80% Fuel Natural Gas Natural Gas Fuel cost 4.5 USD/ 1000 ft3 4.5 USD/ 1000 ft3 Fuel efficiency 1000 BTU/ft3 1000 BTU/ft3 Condensate return 30% 30% Boiler blow down rate 10% 5% Hours of operation 6600 hrs/yr (275 days/yr) 6600 hrs/yr (275 days/yr) Feed water costs 1.2 USD/1000 gallons 1.2 USD/1000 gallons Sodium Sulfite cost 0.5 USD/lb 0.5 USD/lb Feed water temperature 60 F 60 F Inlet Dissolved 9.0 ppm 0.5 ppm

Comparison of Chemical Treatment System to Degassing System Chemically Treated Feed Water Degassed Feed Water Savings Chemical cost $2,299.00 $128.00 $2,171.00 Blow down water costs $1055.00 $500.00 $555.00 Energy cost due to heat $11,095.00 $5256.00 $5,839.00 loss in blow down Total yearly costs/savings $13,997.00 $5,669.00 $8,565.00 Membrane System Operating Cost In order to produce feed water with low levels of dissolved oxygen, a membrane system can be used. The running cost of a membrane system is made up of electricity and seal water for the vacuum pump. The costs for a system designed to operate at the conditions above is outlined below. (56) Operating Cost of a Membrane System Utility Yearly Operating Cost VP operating cost 1.5 kw Seal water 0.4 gal/min $346.50 (Based on 0.035 USD/kW) $190.00 Total $536.50 The operating cost of the membrane system is less than 550.00 dollars per year. When comparing this to the chemical treatment system only, a 1,600.00 dollar per year savings can be realized. When the savings associated with blow down is included, the operating costs savings can be more than 8,000.00 dollars per year. A typical membrane system designed to degas the water outlined in this example can have a payback in less than two years. (75)

In addition to the operating cost savings, a membrane-based system has other advantages as well. It is an ecologically friendly system that reduces the dissolved oxygen in the water without the addition of chemicals. ShenLan Environment Inc located in Shanghai China uses Liqui-Cel Membrane Contactors in their boiler feed water treatment systems. These systems realize lower operating costs with the added benefit of reducing the chemicals added to the boiler feed water. Two photographs of systems built by Shen Lan are shown below. (83) Steam Deaeration A Liqui-Cel Contactor System built for Boiler Degassing by Shen Lan Many boilers use a steam deareator to degasify the boiler feed water. These devices use steam that is produced by the boiler to remove dissolved oxygen. Steam is brought into contact with the feed water. The steam preheats the feed water and strips out the dissolved gas. Some portion of this steam must be vented off to remove the gasses from the system. This venting is essentially a loss of energy and can be calculated in the same manner that the energy loss associated with blow down was calculated. Steam deareators typically need to vent approximately 10% of the feed to the deareator to purge the dissolved gasses from the water. They also need to operate at 2-4 psig. During peak operating times the pressure may be difficult to maintain so additional boiler capacity may be required. These added boiler loads should be included in an operating cost analysis. (221) Summary Dissolved oxygen control in boiler feed water is an important process that protects the boiler from corrosion. Chemical treatment is often used to control the dissolved oxygen. Liqui-Cel Membrane Contactors can be used to replace or supplement the chemical treatment program. The Contactors can minimize

the volume of chemicals added to the feed water and offer savings to the end user by reducing chemical as well as energy costs. References 1. Wiesler, F Membrane Contactors an Introduction to the Technology, ULTRAPURE WATER (Sept 1996) Tall Oaks Publishing 2. Steam tip sheet 9 from the USDOE ref DOE/GO-10099-954 3. Recommended ABMA & ASME Boiler Water Limits - download from Anderson Water Systems www.awsl.com 4. Edited by C R Westaway and AW Loomis Properties of Saturated Steam Cameron Hydraulic Data (16 th edition), Ingersoll Rand Woodcliff Lake, NJ 5. Communications with Dr Avijit Dey R&D Manager, Chemitreat Private Limited, Singapore 6. Communications with Dr Her ShenLan Environment Inc, Shanghai China About the Author Fred Wiesler is a Technical Sales Manager in the Industrial Separations Group of Membrana. He has over ten years experience in the field of membrane separations. He has authored several papers on membrane-based applications and holds patents on the design of membrane contactors. He is currently responsible for sales and service of Membrana s Membrane Contactor product line for Asia. Word Count (not including formulas): - 1689 including table words - 1494 without tables