Available online at ScienceDirect. Energy Procedia 57 (2014 )

Similar documents
Effect of Building Shape And Neighborhood Design On Solar Potential And Energy Performance

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

An enhancement of the daylighting from side-window using two-section venetian blind

The effect of shading design and control on building cooling demand

Energy Saving Benefits of Daylighting Combined with Horizontal Exterior Overhangs in Hot-and-Humid Regions

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

The Effects of Light Shelf on Climate-based Daylight performance in Tropics- A Case Study

Available online at ScienceDirect. Energy Procedia 57 (2014 )

SIMULATION-ASSISTED DAYLIGHT PERFORMANCE ANALYSIS IN A HIGH-RISE OFFICE BUILDING IN SINGAPORE

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

SPLIT CONTROLLED BLINDS AS A THERMAL AND DAYLIGHTING ENVIRONMENTAL CONTROL SYSTEM

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

Available online at ScienceDirect. Energy Procedia 78 (2015 )

NRC CONSTRUCTION TECHNOLOGY UPDATE

SKYLIGHT DESIGN PERFORMANCE EVALUATION METHOD DEVELOPMENT WITH THERMAL AND DAYLIGHT SIMULATION

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

EE2E045 A Calculation Method on the Energy Demand of Urban Districts

THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING AND ENERGY PERFORMANCE FOR AN OFFICE BUILDING IN CANBERRA

DEVELOPMENT OF OPTIMIZATION METHODOLOGY FOR INCREASED ENERGY EFFICIENCY OF PV INTEGRATED CURTAIN WALL SYSTEMS

BUILDING INTEGRATION OF RENEWABLE ENERGY SYSTEMS TOWARDS ZERO OR NEARLY ZERO ENERGY BUILDINGS

Enhancing visual comfort in classrooms through daylight utilization

COMPARATIVE EVALUATION OF SIDE-DAYLIGHTING STRATEGIES

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Solar Shading System Based on Daylight Directing Glass Lamellas

Reducing energy demand in non-domestic buildings: integrating smart facades, ventilation, and surface heating and cooling

A Study of Daylight Metrics Elucidating a basis for a common European approach

Irvine CA MAE ROW ROW ROW. Office Lighting Plan. Page 93

Assessing the energy performance of modern glass facade systems

ScienceDirect. Simulation based mixed mode building design

Procedia - Social and Behavioral Sciences 216 ( 2016 )

Volume 8, ISSN (Online), Published at:

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Utilization of Combined Daylighting Techniques for Enhancement of Natural Lighting Distribution in Clear-Sky Residential Desert Buildings

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

DESIGN METHODOLOGY FOR OPTIMIZATION OF ELECTRICITY GENERATION AND DAYLIGHT UTILIZATION FOR FAÇADE WITH SEMI- TRANSPARENT PHOTOVOLTAICS

Daylight Harvesting in Tropic

Available online at ScienceDirect. Energy Procedia 91 (2016 )

The Assessment of Advanced Daylighting Systems in Multi-Story Office Buildings Using a Dynamic Method

MODELLING THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING PERFORMANCE OF AN OFFICE BUILDING IN SINGAPORE USING ENERGYPLUS

USE OF NET ZERO ENERGY SOLUTION SETS FOR THE REDESIGN OF THE REUNION ISLAND ENERPOS BUILDING IN CHRISTCHURCH

SAGEGLASS VARIABLE TINTED GLAZING INPUT SHEET FOR DIAL+ SOFTWARE

BIPV a-si through façade

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Comparative Performance of Internal Venetian Blind and Roller Blind with Respects to Indoor Illumination Levels

Case study of increasing photovoltaic energy solar fraction in a conventional office building in northern latitudes

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

PRELCO INC. INSULATING GLASS THERMALITE

Available online at ScienceDirect. Energy Procedia 70 (2015 )

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 20 26

Analysis of the effect of artificial lighting on heating and cooling energy in commercial buildings

Available online at ScienceDirect. Energy Procedia 78 (2015 )

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

Modeling Energy Consumption Effects of Glazing

Cost Optimal Retrofitting Of Shopping Malls In Europe

Daylight And Seating Preference In Open-Plan Library Spaces

Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment

Introduction to basics of energy efficient building design

Solar Energy for Hospitals

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

Comparison of Energy and Visual Comfort Performance of Independent and Integrated Lighting and Daylight Controls Strategies

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Facade Design for Super High- Rise Building in Subtropic Region in China

PRELCO INC. PRINTED PREL-DESIGN GLASS

Systematic Analysis on Sustainable Retrofit of Typical High-rise Community Based on Building Performance Simulation Model Yang Hongwei 1,*, Liu Congho

Effect of Building Orientation and Window Glazing on the Energy Consumption of HVAC System of an Office Building for Different Climate Zones

DAYLIGHTING PERFORMANCE OF TOPLIGHTING SYSTEMS IN THE HOT AND HUMID CLIMATE OF THAILAND

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Dynamic facades, the smart way of meeting the energy requirements Johnsen, Kjeld; Winther, Frederik Vilbrad

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

Curtainwalls. Brussels Window. Objectives. Windows & Curtainwalls. Curtainwalls. 1 R2 R3. High tech? Low tech?

Building Technology Research in Architectural Practice: Lessons Learned from Implementations of Energy-Efficient Advanced Building Technologies

Optimization of an external perforated screen for improved daylighting and thermal performance of an office space

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

The Study on the Elevation Design of Apartments Incorporating Daylight Performance

An Experimental Study for the Evaluation of the Environmental Performance by the Application of the Automated Venetian Blind

Available online at ScienceDirect. Energy Procedia 91 (2016 )

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

Monitoring of Advanced Facades and Environmental Systems

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

New solar shading system based on daylight directing solar glass lamellas

Veronica Garcia-Hansen Gillian Isoardi Michael Hirning John Bell

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 2 Heiselberg, Per Kvols. Publication date: 2016

What is Sustainable Design?

additional cooling energy consumption. Because the thermal resistance of windows has always been a weak point, even with vacuum glass or low-e glass,

Automating the Balance of Energy Performance with Occupant Comfort with Smart Fenestrations

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Module 3: Simulation and Data Analysis

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

Daylight Factor Analysis with Slat Angle Control for Glare Reduction in a Three Storied Office Building

Student Modeling Competition

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

Transcription:

Available online at www.sciencedirect.com ScienceDirect Energy Procedia 57 (2014 ) 1815 1824 2013 ISES Solar World Congress Design of Curtain Wall Facades for Improved Solar Potential and Daylight Distribution Caroline Hachem*, Andreas Athienitis and Paul fazio Concordia University, 1455 Maisonneuve W.Montreal, Quebec, Canada, H3G 1M8 Abstract The current paper presents a study of the effect of equatorial-facing façade design on energy performance of multi-story buildings. Façade surfaces are assumed to be in the form of curtain walls, allowing for freedom in the design of surface geometry. The design parameters that are investigated include geometrical aspects, solar technologies integrated in the facades and the surface ratio and positioning of windows. The study is carried out for Montréal area (45 N). Preliminary results indicate that some designs are significantly more advantageous than a flat south facing façade. Electricity generation of PV system integrated in 50% of the surface of a façade shaped as folded platecan be increased by up to 56% as compared to theflat south facing façade, which serves as reference. When PV coverage is increased to 2/3 of the façade surface area, electricity generation can reach a factor of 2.8 of the reference.heating and cooling loads are affected as well by the design. The increase of heating load can be mitigated by increasing the transparency of PV panels.the design of folded plates can affect daylighting level and distribution. While the total useful daylighting hours are not significantly compromised, for some configurations, the number of hours with large illuminanceis significantly reduced, as compared to the reference case. 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license 2013 The Authors. Published by Elsevier Ltd. (http://creativecommons.org/licenses/by-nc-nd/3.0/). Selection Selection and/or and/or peer-review peer-review under responsibility under responsibility of ISES. of ISES Keywords: Curtain wall; photovoltaic sytem; semi-transparent photovoltaic; daylight;energy genration. 1. Introduction Compact urban development with vertical zoning offers an efficient high-densitydesign. These forms of development require less land, increase energy saving on space heating and cooling and help in reducing infrastructure demand, as compared to low density, spread development [1]. However, roof and façade surfaces available in conventional multi-story buildings for integration of solar collector systems * Corresponding author. Tel.: +1-514-6384937 E-mail address:carolinehachem@gmail.com; c_hachem@concordia.ca 1876-6102 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/). Selection and/or peer-review under responsibility of ISES. doi:10.1016/j.egypro.2014.10.045

1816 Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 are restricted [2]. Multistory buildings have inherently limited roof area per overall occupied floor area. This implies that the energy generated by roof- integrated PV systems would cover only a small fraction of energy consumption of these buildings. Moreover, electricity generation by PV systems integrated in equatorial-facing facades is reduced by up to 40% as compared to an equatorial facing roof surface with an optimal tilt angle. The optimal tilt angle is generally equal to the latitude (latitude -15 o for summer, and latitude +15 o for winter)[3, 4]. Increasing electrical generation and solar potential of tall buildings can therefore be attained by manipulation of the geometry and other design features of the facades, subject to visual and functional constraints, such as window design and positioning. A curtain wall system represents an efficient way to integrate photovoltaic modules. Photovoltaic curtain wall may offeradvantages including reducing temperature rise of wall surface and consequently the heat-exchange between outdoor and indoor [5], offering sun-shading by utilizing semi-transparent photovoltaic panels, and can be utilised for aesthetic effects. Distribution of the vision portion of the facade with respect to the opaque portion, where PV systems can be integrated, should be optimized fromthe early design stages. Semitransparent PV (STPV) options can be a good compromise that offers a degree of light transmission in addition to electricity generation. By adjusting the distance between solar PV cells, it is possible to regulate the light transmission, and consequently the level of shading inside the building. Provision of adequate levels of daylight is considered beneficial for the well-being and productivity of occupants [6], andcan significantly affect artificial lighting,and thus reduceenergy consumption [7, 8]. Excess of high levels of daylight illuminance(>2500 lux on the workplane) should be avoideddue topotential visualdiscomfort and the riskof overheating. The objective of this study is to analyze the effect of manipulating the design of curtain wall façades in multistory buildings on energy performance and on the level and spatial distribution of daylighting. This study is expected to contribute to improved energy efficiency and energy generation of tall buildings. 2. Design Approach The current study investigates a number of design options of an equatorial- facing curtain wall façade (south facing in the northern hemisphere) on the energy performance of a single south facing apartment within a mid-rise apartment building (see Fig. 2). While construction details of the facades are not elaborated, curtain wall construction is assumed to facilitate flexibility of geometric design. The apartment is designed to be energy efficient (wall and roof insulation of 7RSI and 10RSI, respectively; triple glaze, low-e argon fill windows(shgc=0.57, Visible transmittance =0.65), and airtight construction) and to conform to passive solar design principles. The basic design of the units relies on passive solar design principles [9]. All apartments in the buildings are designed with a ratio of the south façade to the perpendicular façade of about 1.3. This ratio falls within the optimal range that maximizes passive solar gains in winter, for the south facing apartments,without compromising cooling loads. Heating and cooling energy consumptionare computed assuming a heat pump with coefficient of performance (COP) of 4 [10].An intelligent shading control is considered: Interior blinds (reflectance of 0.69) are assumed to be shut when the indoor air temperature exceeds 22 C, throughout the cooling season.

Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 1817 2.1 Parametric Investigation The design options whose effects are analyzed include variations on the basic geometry of the façade, the type of solar technology integrated in the proposed design of the curtain wall façades and the positioningand size of the vision portion. Investigated façade geometries include, in addition to flat, planar surface, which serves as reference, folded plates with different orientations and tilt angles of the panels. The basic folded plate unit is shown in Figure 1 and its implementation over the top 2 stories of a 6 story apartment building is shown in Figure 2.The basic unit is composed of 4 plates, the upper plates (UP) are used to integrate the PV systems, while the lower plates (LP) comprise the vision part. The orientation angle of a surface, relative to south, can be defined as the angle between south and the projection on a horizontal plane of the normal to this surface. Tilt angle of a surface is the angle between the normal to this surface and a vertical axis. Two combinations of tilt and orientation angles are investigatedin this study. The first set of configurations combines atilt angle of 70 and orientation of 15 east or west of south, and the second set combines a tilt angle of 60 and orientation angles of 20. It should be mentioned that, within a folded plate unit, the plates are symmetrically oriented toward east and west ofsouth. Upper Plates (UP) 30 30 Lower Plates (LP) (Vision part) 20 Front view Side view 20 Front view Side view Plan view (a) Asymmetric configuration (AS-C) Plan view (b)symmetric configuration (S-C) 30 30 20% Vision part, bottom of UP 20% Vision part, top of UP (c) (d) Figure 1, Folded plate module of 60 o tilt and 20 orientation: (a) Asymmetric design (AS-C (60, 20)); (b) Symmetric design (S-C (60, 20); (c) illustration of AS-C5; (d) illustration of AS-C6 Two main designs of folded plates are investigated: symmetric and asymmetric. In symmetricconfigurations, upper plates (UP) and the lower plates (LU) haveequal surface area (Fig. 1b). In the asymmetric configuration, the upper plates are twice as large as the lower plates (Fig. 1a). The configurations are represented by the letter S-C or AS-C to indicatewhether they are symmetric or asymmetric,followed by a pairof numbers indicating the tilt and orientation angles, respectively.basic

1818 Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 folded units in this study are assumed to cover the south façade of a single apartment. This position can be shifted according to needs, to have for instance the glazing in the middle section of the façade. In addition to the effect of façade surface geometry, the effect of varying the proportion of transparent to opaque areas of façade surface is investigated. Position of the vision part (transparent section) is expected to affect light distribution within the lighting zone of the apartment. This effect is investigated by comparing configuration in which the windows are located on the bottom part of the UP (20 cm from the joint between UP and LP) and on the top of the UP (40 cm from the top of the plates)(fig. 1, c and d). These transparent sections constitute 20% of the area of the UP, in S-C and AS-C configurations. Reference case Studied case (a) (b) (c) Figure 2, Six-story apartment block: (a) illustration of the reference apartment; (b) planview; (c) Illustration of the building with a folded plate curtain wall. Solar technology aspects include the integration of PV systems and semitransparent PV (STPV). STPV with transparency of 10%, 20% and 30% are analyzed. The effect of STPV on light distribution is not analyzed in this study.the characteristics of all configurations are shown in Table 1. The size of the vision part of this folded plates design is expressed as percentage of the corresponding plates, while the PV and the STPV size is expressed as percentage of the overall façade.the configurations of Table 1 are investigated for (70, 15 ) and for (60, 20 ) tilt/orientation of the plates. Table 1, Parameter combinations of studied the configurations Description Symmetric folded plates Asymmetric folded plates Configuration Glazing PV STPV Lower plates-lp Upper plates-up Ratio to Ratio to Ratio to LP Position Ratio to UP facade facade Transparency S-C1 90% - 50% - - S-C2 90% (see STPV) - 50% 10% S-C3 90% (see STPV) - 50% 20% S-C4 90% (see STPV) - 50% 30% S-C5 90% Top 20% 40% - - S-C6 90% Bottom 20% 40% - AS-C1 90% - 70% - - AS-C2 90% (see STPV) - 70% 10% AS-C3 90% (see STPV) - 70% 20% AS-C4 90% (see STPV) - 70% 30% AS-C5 90% Top 20% 56% - - AS-C6 90% Bottom 20% 56% -

Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 1819 The response variables are heating and cooling loads, energy generation and daylighting illuminance and its spatial distribution. Effects are measured by comparing the results to the reference design. The reference is a vertical south-facing surface with a PV system assumed to cover 50% of surface area. 2.2 Simulations Simulations employing the EnergyPlus software [11] are performed to assess values of the response variables. Geometric data of investigated configurations needed for the simulations are generated by Google Scketchup [12]. The weather data for Montreal, Canada (45 N) is employed to represent a northern mid-latitude climate zone. Two design days, winter design day (WDD) and summer design day (SDD) are employed in the simulations to represent winter and summer climatic conditions. Design days are used to study daylighting levels and its space distribution. Additionally, a whole year weather data set is used to estimate annual electricity generation of the PV system installed on near south-facing façade surfaces, as well as energy demand for heating and cooling of the apartment unit, and the number of yearly hours of useful daylighting (see below for more details). The TRNSYS PV model (or equivalent one-diode model) provided by EnergyPlus is employed in electricity generation simulations of the BIPV systems with approximately 12.5% efficiency, under standard conditions. Daylighting:Daylight analysis is performed to enable general comparison between design options. In practice, for design purposes a more detailed daylighting model that integrates advanced shadingsuch as reflective venetian blinds over each section and glare control would be advisable. The evaluation of daylighting is based on an analysis of hourlyilluminance values across the workplane an imaginary horizontal plane situated at the working height (0.8m from the floor). These predictions are used to evaluatethe overall daylighting potential of the design options and the daylight distribution.daylight illuminance values are computed at approximately 100 points evenly distributed over the workplane. The analysis of the illuminance values, obtained from the simulations, isbased on the useful daylight illuminance (UDI) scheme [13, 14]. The UDI describes the annual occurrence of illuminances considered as useful" by occupants. Theseilluminance values are based on surveys carried mainly on office buildings. For residential buildings a higher upper limit for UDI (up to 2500 lux) is suggested. In this study the UDI values,determined at each calculation point,are divided into three ranges defined as follows: UDI supplementary (or UDI-s): The illuminance levels range between 300 and 500 lux. These levels of illuminance may require additional artificial lighting to supplement daylight for common task.in this project the lower limit in this scheme is assumed at 300 lux. UDI autonomous (or UDI-a):The illuminance levels range between 500 lux and 2500 lux. This categoryrepresents occurrence of daylight where no additional artificial lighting isneeded. UDI exceeded (or UDI-e): Theilluminance levels are greater than 2500 lux. Moderate occurrence of illuminances greater than 2500 luxmay be beneficial, and therefore it should not be excluded altogether. Careful attention should be paid to the degree of occurrence of the UDI-e metric [15].

1820 Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 Analysis of Results 3.1. Energy Performance Effects of key design parameters of the curtain wall facade on energy consumption(heating and cooling load) and on energy generationare assessed by comparison to the reference case (apartment with flat façade). Results are presented in Figure 2. The main effects are highlighted below. The results for configurations C (70, 15 ) indicate that the heating load is increased by a maximum of 12% for the UP (S-C1 (70,15 ))configuration, but it decreases by 6% for S-C4, wheresemitransparent PVwith 30% transparency is employed(refer to Table 1for details of configurations). The increase in heating load is related to the percentage of the vision sections (or transparency) within the façade and therefore the amountof passive solar heat gain. Asymmetric configurations show the same pattern.pv panels coveringthe total area of the UPs increase heating load by up to 45%. Employing STPV decreases this load. Configurations with tilt/orientation60 / 20 demonstrate asimilar behavior; however heating loads are generally larger in the symmetric configurations while cooling loads are lower by up to 50%. Results are shown in the graphs of Figure 3 for the configurations (70, 15 ) and (60, 20 ). The energy generation of all configurations of folded plates significantly counterbalances the increase in energy consumption for heating. Energy generation is considerably higher for the folded plate curtain wall design, than for the reference south façade covered by 50% of PV. For instance, S-C1 (70, 15 ) produces 56% more electricity than the reference case, while configuration S-C1 (60, 20 ) produces 230% electricity as compared to the reference case. Electricity generation of asymmetric configurations issignificantly higher,by up to 250% for AS-C(70, 15 ) and up to 280% for AS-C(60, 20 ). These configurations are advantageous also with the use of STPV of 20% or 30% transparency. For instance AS-C3(60, 20 ) and AS-C4(60, 20 ) generate 224% and 196% electricity, respectively, relative to the reference case. (a) (b) Figure 3, Energy performance of different configurations relative to the reference case: (a) Configurations (70, 15 );(b) Configurations (60, 20 ). 3.2. Daylighting Illuminance levels

Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 1821 The illuminance level (in units of lux)iscomputed at 100 points evenly distributed over the work plane. Analysis of daylighting level is conducted for two reference points, the first reference is in the middle of the zone (at 4.5 m distance from the south façade),while the second point is at the back of the zone (9 m deep). The results in the two reference points are represented in figure 4 aand b, in termsof annual number of hours of UDI-s, UDI-a and UDI-e, associated with different design options. The reference flat façade provides the largest number of hours of UDI-e per annum, where the illuminance level exceeds the upper desirable level of 2500lux(over some 350 hours per annum at reference point 1), and the largest number of annual autonomous hoursof useful daylighting - UDI-a (Fig. 4c). The results also indicate that configurations with STPV, or a percentage of transparency on the UPs, would give larger number of UDI-s than the reference case, and lower number of UDS-a. The overall useful daylighting hours (sum of UDI-s and UDI-a, Fig. 4c) of all configurations with a certain percentage of transparency within the UPs, is comparable to that of the reference case, ranging from 70% to 98% of the overall useful daylighting hours of the reference case. hrs/yr 1600 1400 1200 1000 800 600 400 200 0 Reference Rectangle (a) Hours of Useful daylighting S-C1 S-C2 S-C3 S-C4 AS-C1 AS-C2 AS-C3 AS-C4 S-C1 S-C2 S-C3 S-C4 AS-C1 AS-C2 AS-C3 AS-C4 (70,15) (70-15) (60,20) (60-20) (b) (c) Figure 4, Annual hours of UDI, (a) at reference point 1, (b) at reference point 2, (c) Overall UDI at reference point 1

1822 Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 Daylight Distribution The average daylight illuminancefor the daylight hours of the SDD and WDD at all 100 studied points is plotted, for some of the studied configurations:flat façade (reference Fig. 5a-4h), S-C1(70, 15 ), S-C5 (70,15 ) and S-C6(70, 15 ). Configurations S-C5 (70, 15 ) and S-C6(70, 15 )display the effectof positioning the vision part in the upper plateon the distribution of lighting. The figuresshow that illumination for WDD is order of magnitudes higher than for SDD. This can be explained by the low sun position in winter, as well as by the shading control that is activated when the summer indoor temperature exceeds a set point of 22. The flat façade and S-C6(70, 15 ) have better distribution of lighting for thesummer day than the other configurations. For the WDD, the flat façade would cause the occurrence of glare in the middle of the zone. All other configurations have more uniform illuminancedistribution. Configurations S-C5 (70, 15) and S-C6(70, 15 ) allow deeper penetration of daylight, where uniform valuesof UDI-s and UDI-a are identified. (a) Flat façade-sdd (b) Flat façade- WDD (c) S-C1(70, 15 ) -SDD (d)s-c1(70, 15 ) -WDD

Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 1823 (e) S-C5(70, 15 ) -SDD (f) S-C5 (70, 15 ) -WDD (g) S-C6(70, 15 ) -SDD (h) S-C6(70, 15 ) -WDD >2500 Figure 5, Averageilluminance (lux)distribution during the daylight hours of the SDD and WDD, at 100 points studies at the workplane level. Summary and Discussion This study compares the performance of curtain wallfacades of varying designs incorporating photovoltaics (opaque and semitransparent) onenergy performance and daylighting level and distribution for an apartment within amid-rise apartment building. Folded plate design with different orientation and

1824 Caroline Hachem et al. / Energy Procedia 57 ( 2014 ) 1815 1824 tilt angles of the plates are designed. Size and positioning of vision parts, and solar technologies (PV and STPV) are theparametersgoverning the response values. The results indicate that heating load is affected mainly by the degree of transparency (opening size and use of STPV). Larger openings (windows) size reduce heating load, due passive heat gain. Cooling load is not significantly affected. Electricity generation is significantly increasedwhen a folded-plate design of curtain wall is adopted. The design can increase generation by up to 280%, relative to the reference flat plate façade,depending on the design of the plates and the percentage ofopenings. Asymmetrical design of the plates allows larger upper plates for PV integration resulting in increased electricity production. The most advantageous folded plate configuration would be an asymmetrical design that combines a tilt of 60 and an orientation of 20 east and west from south. Installing a semitransparent PV system with a transparency of 20-30% would present a good compromise between reducing energyconsumption and increasing generation. This design enables to obtain a large number of annual useful daylight hours (ranging between 300 and 2500 lux), which is comparable to the flat façade, while reducing significantly the occurrence of glare. Another alternative of design is to install PV system on the upper panels, together with a vision part of 20-30% of the plates area. Implementing such folded plates curtain wall design presentsnumerous benefits for multistory buildings. Such design increases significantly the electricity generation potential of facades for buildings that have limited roof areas and it can be applied to retrofit existing buildings. The design would not affect the area and the perimeter of the building, especially if it is applied to the upper floors. References [1] Hui, S. C. M., 2001. Low energy building design in high density urban cities, Renewable Energy, 24 (3-4): 627-640. [2] Hachem, C., Athienitis, A. and Fazio P., 2013. Effect of Housing Density on Energy Performance of Solar-optimized Residential Configurations, CISBAT, Sep. 5-6, Lauzanne, Switzerland. [3] Hachem C., A. Athienitis, P. Fazio, 2012. Design of roofs for increased solar potential of BIPV/T systems and their applications to housing units. ASHRAE Transactions, RNS-00226-2011.R1. [4] Duffie, J.A. and Beckman, W.A., 2006. Solar Engineering of Thermal Processes. Wiley, 928 pp. [5] Quirouette, R., 1999.Glass and Aluminium Curtain Wall Systems.CMHC-SCHL. https://www.cmhcschl.gc.ca/en/inpr/bude/himu/coedar/upload/glass-aluminum-curtain-wall-systems.pdf.visited on 10 April, 2013. [6] Heschong, L., 2002. Daylighting and human performance. ASHRAE Journal, 44(6):65-67 [7] Crisp, V.,Littlefair, P.,Cooper, I.,and McKennan. G. T.,1988. Daylighting as a passive solarenergy option: An assessment of its potential in non-domestic buildings. Building Research Establishment Report, Garston, CRC. [8] Reinhart C. F. and Voss, K.,2003. Monitoring manual control of electric lighting and blinds. Lighting Research and Technology, 35(3):243-258. [9] Chiras, D. 2002. The Solar House: Passive Heating and Cooling. White River Junction, VT : Chelsea Green Publishing, 2002. [10] Hachem C., Fazio, P., and Athienitis, A., 2012. Energy Implications and Solar Energy Potential of Housing Units Shapes, The 5th International Building Physics Conference (IBPC5), Kyoto, Japan. [11] EnergyPlus. 2010. Version 6. 0. Lawrence Berkeley National Laboratory, Berkely, CA. [12] Google SketchUp Plugins, 2011. http://sketchup.google.com/intl/en/download/plugins.html [13] Mardaljevic, J. and Nabil, A.,2005. The useful daylight illuminance paradigm: A replacement for daylight factors. Lux Europa, Berlin, pages 169-174. [14] Reinhart, C. F., Mardaljevic, J., and Rogers, Z.,2006. Dynamic daylight performance metricsfor sustainable building design. Leukos, 3(1). [15] Webb, AR.. Considerations for lighting in the built environment: Non-visual effects of light. Energy and Buildings, 38(7):721{727, 2006.