Implications for Sustainable Design of Glass Facades

Similar documents
Thermal Bridging and Whole Building Energy Performance

Bridging on Building Envelope Performance. A Whole Building Energy Perspective

The Concept of Linear and Point Transmittance and its Value in Dealing with Thermal Bridges in Building Enclosures

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Final version for publication High Performance Curtain Wall using Vacuum Insulated Panel (VIP) Spandrels

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Pro-Demnity Insurance Company

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

Professional Educational Series BSP716 USGBC # Commercial Building Science Thermal Control in Building Envelopes

Thermal Performance of Northern Facades ISO Clip System Summary

Energy Code Compliance:

Ontario Building Code Breakfast

Thermal Analysis of CL-TALON Cladding Support System

Building Envelopes 101

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

Thermal Bridging and Energy Standards 2014 BOABC Education Conference. November 27, 2014

Break it, or Lose it: Thermal Bridging in Building Envelopes

High Performance, Energy Efficient Design for Wood Frame Buildings

Michigan Energy Code Training and Implementation Program

COMMERCIAL FENESTRATION FUNDAMENTALS & DESIGN CONSIDERATIONS

Optimizing Energy Efficiency During Integrated Design: A Whitehorse Case Study

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

BETA OPTION 1: PERFORMANCE RATING METHOD. Section General Information

OUTLINE. Building Envelope Thermal Bridging Guide. High Level Overview and Themes. The Code Context. The Energy Context. Where do we go from here?

No ASHRAE Standard By Susan Hayes, P.Eng., LEED AP BD+C & Graham Finch, Dipl.T, MASc, P.Eng. October 2012 rdh.com 1

Ontario s Building Code

Italcementi Center for Research and Innovation

Residential Energy Code Update

Applying Energy Code to Existing Buildings

Colorado Mountain College: Sustainable Design Standards

CREDIT COMPLIANCE (Please complete the color coded criteria(s) based on the option path selected)

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

and LEED Energy and Atmosphere Credits Jean Ascoli, LEED AP BD+C Architect, Energy Specialist

Understanding the National Energy Code of Canada for Buildings, 2011

Building Envelope

Dayton Chapter February 9, Bob Thomson, P.E., LEED-AP, CDT

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Commercial Air Barrier Systems

Impact of Insulated Concrete Curb on Concrete Balcony Slab

University of Minnesota Duluth Civil Engineering Building

ENCLOSURE SOLUTIONS THERMAL BRIDGING GUIDE FIBERGLAS FOAMULAR THERMAFIBER

Next Connecticut Energy Code

COMMERCIAL ENERGY EFFICIENCY

Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates. Jeff S. Haberl, Ph.D., P.E.

Push the Envelope: High-Performance Design in High-Rise Buildings

Gerald R. Ford Museum

Energy Efficiency / Renewable Energy (EE/RE) Projects in Texas Public Schools

What s My Baseline? ASHRAE

Energy Star Qualified - New Homes

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

2010 Residential Energy Checklist: Additions/Alterations (Prescriptive Approach)

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

National Energy Code for Buildings 2011

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Be Aggressive About the Passive Solutions

ERI vs. Performance Path: Which is better for the builder?

Energy-Efficient Facilities: Building Envelope Design. Wall Systems. Copyright Materials. Course Description

IMPACT OF CLIMATE CHANGE

Residential Energy Code Compliance

Manitoba Energy Code for Buildings. Part 3 Building Envelope

Optimise the Specification of a Building Envelope

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

EIFS The cladding with the lowest carbon footprint

2010 National Building Code Adoption and Associated Process Changes

PART 2 ENERGY SAVINGS AND COST BENEFIT ANALYSIS

Deep Energy Retrofit of a HighRise MURB

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE

Application for a Permit to Construct or Demolish This form is authorized under subsection 8(1.1) of the Building Code Act,1992

INSULATED METAL PANELS INSMP2A 1LU/HSW HOUR Prepared and presented by MBCI

Understanding Energy Codes

how to read an energy model

Energy Codes and the Building Envelope

SB-12, Chapter 3. Applicable to all building permit applications submitted after December 23, 2016

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

Building Enclosure Commissioning: Who, What, When, Why, and How?

Township of Otonabee-South Monaghan

Condominium Project Profile and General Review Form

2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012

Building Enclosure Design Fundamentals, Components, and Assemblies

SECTION ALUMINUM WINDOWS

Welcome to this continuing education seminar. This is the second of three parts of the Building Enclosure Fundamentals series.

BUILDING ENCLOSURE AIR TIGHTNESS TESTING Course Number: BCLUNA018-01P

As curtain wall and window systems. The Perfect (Retro)Fit: Overcoming Challenges with Curtain Wall Retrofits. FEATURE n n n

Energy Efficiency For Housing

Supplementary Standard SB-12. Energy Efficiency For Housing

Agenda. Scope. Market and code. Impact to Buildings. Design Solution. Future. page 2

airflow in to, out of, and within buildings. These airflows are resisted by the airtightness of building elements including the exterior enclosure and

Energy Efficiency Analysis for a Multi-Story Research Office Building (LG Multi V Water IV Heat Recovery VRF System)

The Top 10 Approach to Commercial Energy Code Compliance

ResearcH JournaL 2016 / VOL

Supplementary Standard SB-12. Energy Efficiency For Housing

Chapter 1: Compliance

Designing Beyond Code For Energy Efficiency

OPTION 1: PERFORMANCE RATING METHOD

COMMERCIAL ENERGY EFFICIENCY

Transcription:

Implications for Sustainable Design of Glass Facades How New Energy Codes Will Impact Glazing Design Stéphane Hoffman, M. Eng., M. Arch., PE VP Façade Engineering Group George Torok, C.E.T., BSSO Building Science Specialist

Learning Objectives 1. Review new energy code requirements with a focus on glazing ratios and their impact on the design of glass buildings 2. Review the implication of glazing ratios when evaluating the code compliant baseline building against proposed glass building designs for compliance to sustainability standards 3. Understand the impact of thermal bridging on effective R-value for spandrel and opaque wall assemblies. 4. Learn about new technologies that can increase the performance of glazed assemblies 2

Changing Focus on Envelope Last Decade s Focus: Durability WRB & Rainscreen Design Reviews Field Review & Testing Next Decade s Focus: Energy Air & Thermal Barriers Whole Building Energy Modeling Whole Building Commissioning 3

Challenge for Glass Buildings Recent Energy Codes have raised performance requirements for ALL systems: This makes Baseline Building REALLY efficient HVAC efficiencies can no longer be expected to make up for shortfall in envelope performance Glazing Ratio restriction define performance of the Baseline Building Increasing the Glazing Ratio significantly impacts Energy Performance Spandrel Assemblies challenged to meet increasing performance for opaque walls 4

Building Envelope Design Under the New Energy Codes 1. Introduction 2. Insurance Requirements 3. Energy Codes 4. Glazing Ratios 5. Continuous Insulation and Spandrel Design 6. Case Studies 7. Technical Innovation 8. Expectation versus Reality 9. Future Trends 5

Insurance Requirements

OAA Pro-Demnity Window Wall Endorsement Design requirements: Rainscreen design: Primary and secondary planes of protection Ventilated air spaces between planes Positive drainage to the exterior 3 rd Party review: Independent consultant (architect or professional engineer) with expertise in design and installation of Window Wall systems must review, recommendations must be incorporated into design 7

OAA Pro-Demnity Window Wall Endorsement During design: Manufacturer must submit shop drawings and calculations, sealed by a professional engineer for structural integrity, air barrier continuity and water ingress management Manufacturer must submit air and water leakage resistance test reports Shop drawings and test reports must be reviewed and approved by design architect and independent consultant 8

OAA Pro-Demnity Window Wall Endorsement Before construction: Construct full-scale mock-up including framing, fixed and operable glazing, doors, anchorage, slab edge covers, and transitions to adjoining assemblies Test for air and water leakage and environmental separation to recognized industry standards Construction and testing must be reviewed and approved by the Independent Consultant. 9

OAA Pro-Demnity Window Wall Endorsement During construction: Window wall must be installed in accordance with the approved design, including recommendations of the independent consultant Window wall must be successfully field tested for air and water infiltration to recognized industry standards to the satisfaction of the independent consultant. 10

OAA Pro-Demnity Window Wall Endorsement After construction: 5 year minimum warranty from manufacturer against air and water leakage Includes all labour and materials required to repair or replace if failure occurs during the warranty period 11

Tarion Bulletin 19 for Condominium Construction Before construction: Scope of work: Design and field review services including schedule of site visits -must be proposed and approved by Tarion, to address risk areas, appropriate for the type and size of building to be constructed Design review: Review design documents, mark-up, submit, track resolution Design must comply with OBC and with good architectural and engineering practice 12

Tarion Bulletin 19 for Condominium Construction During Construction: Field review: Throughout construction as outlined in the Scope of Work, nominally: Generally, every 60 days At 75% complete stage At building watertight stage Identify construction deficiencies found, track resolution 13

Tarion Bulletin 19 for Condominium Construction During Construction: Construction submittals: Review, identify deficiencies and changes to design, track resolution, including: Lab test reports for windows and patio doors Field tests: Throughout construction as outlined in the Scope of Work, including: Water leakage resistance tests for windows and patio doors 14

Tarion Bulletin 19 for Condominium Construction After construction: Final Report including: All submitted reports Condominium Declaration and Description (including as-built drawings, specifications, etc.) Designer of Record final clearance letters Field Review Declaration, including: Outstanding deficiencies or unfinished work Cost to correct deficiencies 15

Tarion Bulletin 19 for Condominium Construction Window wall is an identified risk area, specific requirements include: Before construction: Review of details and shop drawings ensuring compliance with the OAA and Pro-Demnitydesign principles and requirements During construction: Factory manufacture review Field mock-up installation prior to installation Field review of adhesives, fasteners, surface preparation, reinforcing, detailing, joint details, finish materials, application, frequency varies with building size 16

Unintended Consequences Pro-Demnity Window Wall Endorsement and Tarion Bulletin 19 are not intended to address energy but 2006 OBC and 2014 OBC include energy performance requirements in Supplementary Standard SB-10 2014 OBC will also include general thermal performance requirements in Parts 5 and 9 to minimize surface condensation on the warm side of the component or assembly including windows, doors and skylights: Performance requirements are not defined in Part 5 Part 9 includes requirements, use as guideline? Must coordinate with SB-10 requirements 17

Unintended Consequences Minimum U-value and Condensation Resistance for Windows, Doors and Skylights NBCC 2010, OBC 2014 Part 9 Table 9.7.3.3 Windows and Doors 2 ½% January Design Temperature Warmer than -15 C -15 C to -30 C Colder than -30 C Max. U-value Min. I-value Max. U-value Min. I-value Max. U-value OR OR OR W/m 2 K W/m 2 K W/m 2 K Min. I-value 2.5 54 2.0 68 1.7 77 Skylights 3.5 None 3.0 None 2.7 None Note: these requirements are for low indoor humidity. Requirements for high indoor humidity are not defined 18

Energy Codes

SB-10 Compliance Paths One of three total building energy consumption performance paths: 1. = ANSI/ASHRAE/IESNA 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings, with modifications given in SB-10 2. 5% over ANSI/ASHRAE/IESNA 90.1 3. 25% over 1997 Model National Energy Code for Buildings 20

SB-10 Compliance Paths 21

SB-10 & ASHRAE 90.1-2010 Outlines minimum performance parameters for: Maximum fenestration-to-wall ratio (40%) Wall, Roofs, Windows elements etc. Prescriptive and performance paths for insulation Weighted U-value allowed for some trade-offs within element type Envelope Trade-off calculations required for trade-offs across element types HVAC and Electrical requirements 22

SB-10 & ASHRAE 90.1-2010 23

SB-10 & ASHRAE 90.1-2010 R2.9 R2.2 24

Glazing Ratio

Glazing Ratios 26

Glazing Ratios Current North American energy code prescriptive path code requirements: ASHRAE 90.1-2010: 40% IECC -2009: 40% IECC 2012: 30% OBC SB-10: 40% A step backward to earlier designs? 27

Glazing Ratios A building can still be all glass with a 40% glazing ratio 28

Thermal Impact of Glazing 3,764 58% 2,764 42% Ratio 10%, Glazing U=0.40 Opaque Wall U=0.059 (R=17) Total Heat Loss = 6528 Btu Area of circle represent total envelope heat loss Fenestration heat loss, UA, Btu/hr-F Opaque wall heat loss UA, Btu/hr-F 29

Thermal Impact of Glazing 3,373 38% 5,504 62% 3,764 58% 2,764 42% Ration = 20% Ratio 10%, Glazing U=0.40 Glazing U=0.40 Opaque Wall U=0.059 Opaque Wall U=0.059 (R=17) Total Heat Loss = 8877 Total Heat Loss = 6528 Btu 36% increase Area of circle represent total envelope heat loss Fenestration heat loss, UA, Btu/hr-F Opaque wall heat loss UA, Btu/hr-F 30

Thermal Impact of Glazing 2,983 27% 8,244 73% 3,373 38% 5,504 62% 3,764 58% 2,764 42% Ratio = 30% Glazing U=0.40 Opaque Wall U=0.059 Total Heat Loss 11227 Btu 72% increase Ration = 20% Ratio 10%, Glazing U=0.40 Glazing U=0.40 Opaque Wall U=0.059 Opaque Wall U=0.059 (R=17) Total Heat Loss = 8877 Total Heat Loss = 6528 Btu 36% increase Area of circle represent total envelope heat loss Fenestration heat loss, UA, Btu/hr-F Opaque wall heat loss UA, Btu/hr-F 31

Thermal Impact of Glazing 2,592 19% 10,984 81% 2,983 27% 8,244 73% 3,373 38% 5,504 62% 3,764 58% 2,764 42% Ratio = 40% Glazing U=0.40 Opaque Wall U=0.059 Total Heat Loss = 13576 Btu 208% increase Ratio = 30% Glazing U=0.40 Opaque Wall U=0.059 Total Heat Loss 11227 Btu 72% increase Ration = 20% Ratio 10%, Glazing U=0.40 Glazing U=0.40 Opaque Wall U=0.059 Opaque Wall U=0.059 (R=17) Total Heat Loss = 8877 Total Heat Loss = 6528 Btu 36% increase Area of circle represent total envelope heat loss Fenestration heat loss, UA, Btu/hr-F Opaque wall heat loss UA, Btu/hr-F 32

Sustainability Standards Sustainability Standards raise the bar further: LEED 2009 ASHRAE 189.1 High Performance Green Buildings International Green Construction Code All require performance over and above baseline energy code 33

Sustainability Standards LEED for New Construction and Major Renovation Energy and Atmosphere Prerequisite No. 2 : Option 1: demonstrate 10% improvement EA Credit 1 (EAc1): Optimize Energy Performance: Option 1: whole building energy simulation: 1 to 19 points for 12% to 48% improvement 34

Compliance Paths Prescriptive Building Envelope Option [tables] Component Performance Building Envelope Option [trade-off] Systems Analysis [energy modeling] 35

Compliance Paths Prescriptive Building Envelope Option [tables] Component Performance Building Envelope Option [trade-off] Systems Analysis [energy modeling] 36

Prescriptive Option PRESCRIPTIVE BUILDING ENVELOPE OPTION Must meet or exceed code specified values Glazing: Vertical Fenestration max U-0.40* Area: 40% max. *metal framing 37

Compliance Paths Prescriptive Building Envelope Option [tables] Component Performance Building Envelope Option [trade-off] Systems Analysis [energy modeling] 38

Component Performance Option COMPONENT PERFORMANCE Design heat loss rate for the proposed envelope assemblies less than target heat loss rate UA p UA t Limited to envelope assemblies Over performance in some assemblies can be traded off for underperformance in others 39

Component Performance Option UA p = U mr A mr + U ad A ad + U rs A rs + U ra A ra + U ogc A ogc + U og A og + U mw A mw + U mbw A mbw + U sfw A sfw + U wfow A wfow + U d A d + U vg A vg + U vgm A vgm + U vgd A vgd + U fm A fm + U fs A fs + U fwo A fwo + F s P s + F sr P sr Don t worry= UA t = U radt A radt + U mrt A mrt + U rst A rst + U ort A ort + U ogcort A ogcort + U ogort A ogort + U mwt A mwt + U mbwt A mbwt + U sfwt A sfwt + U wt A wt + U vgt A vgt + U vgmt A vgmt + U vgdt A vgdt + U dt A dt + U fmt A fmt + U fst A fst + U ft A ft + F st P st + F rst P rst 40

Component Performance Option 41

Trade-Offs 19% 81% 40% Ratio Glazing U=0.40 Opaque Wall U=0.059 (R17) Area of circle represent total envelope heat loss Fenestration heat loss Opaque wall heat loss 42

Trade-Offs 19% 16% 81% 84% 40% Ratio Glazing U=0.40 Opaque Wall U=0.059 (R17) 50% Ratio Glazing U=0.33 Opaque Wall U=0.059 Area of circle represent total envelope heat loss Fenestration heat loss Opaque wall heat loss 43

Trade-Offs 19% 16% 13% 81% 84% 87% 40% Ratio Glazing U=0.40 Opaque Wall U=0.059 (R17) 50% Ratio Glazing U=0.33 Opaque Wall U=0.059 60% Ratio Glazing U=0.28 Opaque Wall U=0.059 Area of circle represent total envelope heat loss Fenestration heat loss Opaque wall heat loss 44

Trade-Offs 19% 16% 13% 81% 84% 87% 40% Ratio Glazing U=0.40 Opaque Wall U=0.059 (R17) 50% Ratio Glazing U=0.33 Opaque Wall U=0.059 11% 60% Ratio Glazing U=0.28 Opaque Wall U=0.059 Area of circle represent total envelope heat loss Fenestration heat loss Opaque wall heat loss 89% 50% Ratio Glazing U=0.35 Opaque Wall U=0.037 (R27)

Trade-Offs 19% 16% 13% 81% 84% 87% 40% Ratio Glazing U=0.40 Opaque Wall U=0.059 (R17) 50% Ratio Glazing U=0.33 Opaque Wall U=0.059 11% 8% 60% Ratio Glazing U=0.28 Opaque Wall U=0.059 Area of circle represent total envelope heat loss Fenestration heat loss Opaque wall heat loss 89% 50% Ratio Glazing U=0.35 Opaque Wall U=0.037 (R27) 92% 52% Ratio Glazing U-0.35 Opaque Wall U=0.024 (R41)

Compliance Paths Prescriptive Building Envelope Option [tables] Component Performance Building Envelope Option [trade-off] Systems Analysis [energy modeling] 47

Systems Analysis Systems Analysis Approach for Entire Building: Proposed building shall provide equal or better conservation of energy than the standard design. Accounts for performance of all systems impacting energy performance: HVAC, Lighting, Envelope, etc. Over performance in some systems can be traded off for underperformance in others 48

Challenge with Systems Analysis The baseline building is a hypothetical code-matching building: The bar has been raised for ALL systems Baseline building already REALLY efficient Unless you are planning on installing highly efficient energy using systems (mechanical, lights, etc.) or incorporating some aspect of on-site renewable energy don t expect to be able to make up for shortfall in envelope performance 49

Continuous Insulation and Spandrel Design

Continuous Insulation Most Energy Codes have enacted continuous insulation requirements to address thermal bridging These codes create specific challenges with respect to spandrel design 51

Continuous Insulation 52

Alternate Means of Compliance Performance based approach provides alternative to these prescriptive requirement: Must demonstrate that proposed assembly meets or exceeds the specified Maximum U-Value 53

Glazing Spandrel Spandrel area interrupted by framing creating a thermal bridge Truly continuous insulation must be provided either inboard or outboard of frame Must demonstrate that proposed assembly meets or exceeds the specified Maximum U-Value 54

ASHRAE Research Project Goals and Objectives of the Project: Calculate thermal performance data for common building envelope details for mid- and high-rise construction Develop procedures and a catalogue that will allow designers quick and straightforward access to information Provide information to answer the fundamental questions of how overall geometry and materials affect the overall thermal performance 55

ASHRAE Research Project Calibrated 3D Modeling Software: Heat transfer software by Siemens PLM Software, FEMAP & Nx Model and techniques calibrated and validated against measured and analytical solutions Guarded hot box test measurements, 29 in total 56

ASHRAE Research Project Details Catalogue: 40 building assemblies and details common to North American construction Focus on opaque assemblies, but also includes some glazing transitions Details not already addressed in ASHRAE publications Highest priority on details with thermal bridges in 3D 57

Applying Results ASHRAE Data Sheets 58

ASHRAE Research Project on 3D Heat Loss ASHRAE Data Sheets 59

Contribution of Thermal Performance of Wall Assembly to Energy Use(GJ/m 2 of Floor Area) 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0.00 U0.26 R-3.9 Clear Wall Only Including Poor Details Including Efficient Details R-4.5 R-5.2 R-5.0 R-5.3 U0.10 R-10.2 R-14.3 R-16.7 Additional building energy use based on thermal performance of the building wall assembly for varying amounts of nominal exterior insulation for a mid-rise MURB in Edmonton (overall assembly thermal resistance in ft 2 ºF h/btu also given) 60

Glazing Spandrel Areas Curtain Wall Comparison No Spray Foam 61

Glazing Spandrel Areas Curtain Wall Comparison Spray Foam 62

Glazing Spandrel Areas Spandrel Section R Value 10 9 8 7 6 5 4 3 2 1 0 8.8 9.1 8.2 7.4 4.8 5.0 4.2 3.4 0 5 10 15 20 25 30 Back Pan Insulation Detail 22 (Air in Stud Cavity) Detail 23 (Spray Foam in Stud Cavity) 63

Glazing Spandrel Areas No Spray Foam Spray Foam 64

Glazing Spandrel Areas Provide R-15 insulation in the back pan Provide continuous insulation inboard of the back pan in an airtight fashion Maximize area with floor to ceiling spandrel to further improve performance 65

Case Studies

Case Study Goal to maximize vision glass 2 levels commercial 19 floors residential Gross wall area = 76,000 sq. ft. All glass envelope Washington State Energy Code prescribes 40% glazing ratio 67

If Fenestration U = 0.35 If effective R-value is equal to Then vision glass area % can be up to 18* 46.2 20 47.0 22 47.9 24 48.7 26 48.7 28 49.6 30 49.6 32 50.5 34 50.5 40 51.3 50 51.3 60 52.2 100 53.0 Vision glazing area, % 60 58 56 54 52 50 48 46 44 0.35 10 20 30 40 50 60 Thermal performance of opaque wall (1/U), h ft2 F/Btu *Code minimum is R-19 cavity insulation + R-8.5 continuous insulation, which is 1/0.057 = R-18 effective [Table 10-5A(1)] 68

For a range of fenestration U-factors Opaque glazing effective R-value and Vision glazing area for a given vision glazing U-factor (colored lines) Vision glazing area maximum, % 60 58 56 54 52 50 48 46 44 10 20 30 40 50 60 70 80 Opaque glazing effective R-value, h ft2 F/Btu 0.31 0.32 0.33 0.34 0.35 69

What does R-33 code compliant wall look like? 5.3 backpan insulation + Insulated knee wall Min. wool R-4.1/in. = R-11.3 eff + R-22.0 eff XPS R-5/in. = R-12.6 eff + R-20.7 eff SPF R-6/in. = R-14.4 eff + R-18.9 eff 70

Horizontal versus Vertical Opaque Areas 51% (vision) glazing R-33 code-compliant opaque wall Maximized floor-to-ceiling opaque panels

Impact on Design Case Study 40-Storey High-rise Condo in Toronto Envelope: Window wall, 70% window-to-wall ratio (therefore Compliance Paths 2 or 3) Vision panels double glazed, thermally broken aluminum frame, R1.9 Spandrel panels single glazed, mineral wool insulation, steel backpan R5.3 Mechanical: Four-pipe fan coil system Forced-draft, 80% efficiency boiler and mid-efficiency chiller Corridor make-up air 72

Impact on Design Case Study Energy performance as designed: End-Use Design (GJ) MNECB Reference (GJ) % Savings Lighting 2,799 2,886 3.0 % Receptacles 1,376 1,372-0.3% Heating 15,539 12,585-23.4% Cooling 1,542 1,220-26.4% Pumps 1,923 2,342 17.9 % Fans 1,545 2,332 33.8 % DHW 5,163 5,014-3.0% Exterior Lighting 38 38 0.0 % Elevators 900 900 0.0 % % Savings Relative to MNECB -7.4% 73

Impact on Design Case Study With some basic energy efficiency upgrades: Envelope: 5% reduction in window-to-wall ratio Mechanical: Variable speed water pumps Mid-efficiency domestic hot water equipment 15% reduction in hot water usage (low-flow fixtures) High-efficiency condensing boiler Occupancy sensors for underground parking garage lights 74

Impact on Design Case Study With some basic energy efficiency upgrades: End-Use Design (GJ) MNECB Reference (GJ) % Savings Lighting 2,649 2,886 8.2 % Receptacles 1,376 1,372-0.3% Heating 9,122 12,585 27.5 % Cooling 1,524 1,220-24.9% Pumps 1,617 2,342 31.0 % Fans 1,814 2,332 22.2 % DHW 3,869 5,014 22.8 % Exterior Lighting 38 38 0.0 % Elevators 900 900 0.0% % Savings Relative to MNECB 20.1 % 75

Impact on Design Case Study With some additional energy efficiency upgrades: Individual suite ERV = 25% over 1997 MNECB (becoming common in high-rise MURBs targeting LEED) Individual suite heat recovery 25% over 1997 MNECB 76

Mechanical is part of the answer= 77

=but the Envelope is the Key! Path of least resistance = window-to-wall ratio reduction Glass building envelopew get ready for innovation Better details (address thermal bridges) 78

The Time is now for a Paradigm Shift Shiftfrom nominal R-value thinking to effective R-value Lookto building envelope to achieve energy gains Movebeyond adding insulation. Efficiency through better details? Be prepared to evaluate new products 79

Technological Innovation

Evolving Technology 81

Evolving Technology 82

Improved Thermal Breaks 83

Alternate Framing Material Pultrudedstranded glass fibers thermally fused with polyurethane 700 times less thermal conductivity than aluminum 84

Improving Insulating Glass 85

Improving Insulating Glass Single vs. Double Glazed Vacuum Insulating Glass IG Clear vs. IG Low-e Warm Edge 86

Vacuum Insulating Glazing 2 plies of 3 mm (1/8 in.) clear glass with low-e Small, 0.7 mm (0.03 in.) dia. pillars spaced on 25 mm (1 in.) centers Vacuum sealed in the gap Low melting temperature solder glass around the edges (one possible method) Resulting glass is just less than 7 mm (9/32 in.) Source: Guardian 87

Vacuum Insulating Glazing Multi-Layer Very High Performance Glazing (HVIG) U-Factor = 0.15 (R 6.7) Passive solar gain low-e: SHGC = 0.57 Tvis= 62% Solar control low-e, green tint: SHGC = 0.195 Tvis= 33% Source: NSG Group/Pilkington 88

Vacuum Insulating Glazing New Construction Hospital in Hokkaido, Japan Apartment House in Kuzaha, Japan Source: NSG Group/Pilkington

Vacuum Insulating Glazing Retrofit & Replacement Hermitage Amsterdam Library of Amsterdam University Source: NSG Group/Pilkington

Vacuum Insulated Panels 91

Vacuum Insulated Panels 92

Making the Most of High Efficiency Glazing Vision Glass Insulating Glass Unit VIG or HVIG Curtain Wall Frame Vision and spandrel panel adhered (SSG) Spandrel Panel Vacuum insulated panel 93

Making the Most of High Efficiency Glazing High Performance Curtain Wall using Vacuum Insulated Panel (VIP) Spandrels Lawrence D. Carbary, Andrew Dunlap, Thomas F. O Connor

Making the Most of High Efficiency Glazing High Performance Curtain Wall using Vacuum Insulated Panel (VIP) Spandrels Lawrence D. Carbary, Andrew Dunlap, Thomas F. O Connor

Electrochromic Glazing Electronically TintableGlass as an Architectural Enabler Helen Sanders, PhD and Louis Podbelski, AIA.

Electrochromic Glazing Electronically TintableGlass as an Architectural Enabler Helen Sanders, PhD and Louis Podbelski, AIA.

Electrochromic Glazing Electronically TintableGlass as an Architectural Enabler Helen Sanders, PhD and Louis Podbelski, AIA.

Electrochromic Glazing Electronically TintableGlass as an Architectural Enabler Helen Sanders, PhD and Louis Podbelski, AIA.

Integrated Photovoltaic 100

Alternate Glazing Material Aerogel Translucent Panels 101

Expectation vs. Reality

Expectations vs. Reality Code compliance does not guarantee energy efficiency: There are many factors that are not currently accounted for Increasingly sophisticated modeling is available to more accurately predict thermal performance 103

Glazing Spandrel Areas Spandrel Section R Value 10 9 8 7 6 5 4 3 2 1 0 8.8 9.1 8.2 7.4 4.8 5.0 4.2 3.4 0 5 10 15 20 25 30 Back Pan Insulation 9.1 40 Detail 22 (Air in Stud Cavity) Detail 23 (Spray Foam in Stud Cavity) 104

Future Trends

The Future of Energy Codes Different approaches can be employed in codes to account for thermal bridging using the same data Performance based Prescriptive based Solutions based The procedures and data provided by 3D modeling promise to enable more development and enforcement 106

The Future It will likely become increasingly more difficult to ignore thermal bridging at intersections of assemblies Move beyond simply adding more insulation Better able to evaluate condensation resistance to improve building durability and occupant comfort 107

The Future Whole Building Energy Efficiency Analysis Input values that account for all thermal bridging More accurate load analysis for sizing Determine cost effectiveness of insulating the building envelope through better details Efficient use of materials Change how sustainable rating programs reward good design for energy efficiency and material use 108

Façade Engineering vs Building Envelope Review vs Manufacturer Consultations Involvement earlier in the design process with initial focus on assemblies over details Focused on performance optimization of envelope assemblies Relies on performance analysis to guide design decisions More holistic approach balancing impact of envelope with other energy systems (HVAC, lighting, etc.) Impartial approach 109

Thank You SHoffman@MorrisonHershfield.com GTorok@MorrisonHershfield.com