Lithia Dodge East 5500 L St. Omaha, NE

Similar documents
MOISTURE MANAGEMENT. Providing roofing and waterproofing solutions. Zionsville High School Roof Asset Management Plan

Summary of Existing Conditions: Point Pleasant Borough High School

Architectural Inspection Low Slope Roofing

HANSON MIDDLE SCHOOL

REPORT OF ROOF CONDITION STUDY. YOUR FACILITY Your Facilities Location. Date YOUR FACILITY S IDENTIFICATION. Prepared for Your Company

Roof Inspection Report

Roof Inspection Report

ADDENDA #3- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

ROOF INSPECTION AND ANALYSIS PROCEDURE QUINLAN ASSOCIATES, LLC. 166 SHORE DRIVE BURR RIDGE, ILLINOIS

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

METACRYLICS ACRYLIC ROOF TOP PENETRATION ROOF DETAILS

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

GAF Scheduled Maintenance Checklist

ASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS

INSTALLATION GUIDE SPECIFICATION

IRS I ndustrial R oofing S ervices, Inc.

July Minimum Fastening Requirements (Fully Adhered)... 5

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

MAINTENANCE INSPECTION GUIDE

Roof Inspection Report

63 + Fix Your Roof... And Fix Your Cost

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Roof Systems ROOFS. Inspections

Roof Inspection Report

OREGON ROOF CONSULTING - ROOF INSPECTION FORM


Buncombe County Schools. Project Address: 21 Trinity Chapel Road, Asheville, North Carolina Abbreviations

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING

ROOF OWNER'S OPERATION AND MAINTENANCE MANUAL

Update In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists

Tuscaloosa Police Station

Architectural Inspection Pitched Roofing

G October 2018

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

Roof Inspection Report

RCi. roof consultants, inc. Thank you for your interest in Roof Consultants, Inc.

Prepared By. Accent Building Sciences Inc. For

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

G October 2018

The Perfect Fit For Your Metal Roof. We ve Got You Covered! 3245 W US Highway 136 Covington, IN

APPLICATION GUIDELINE

Coating over Metal Roof: 5-Year System

838 Coatings System Specification Single-Ply Restoration (838 SPR)

Maintaining Building Envelope Integrity. Is Your Leak REALLY a Roof Leak?

ReflectiClean Acrylic/Urethane

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

ROOF REPORT 3130 TCHULAHOMA

There have been many instances of aircraft hangars roof systems

Light-Metal Roof Edge, Raised

Metal Retrofit Systems from Royalty Roofing

MAGNUM. I N S P E C T I O N S Inc. ROOF Walked on roof, crawled attic where accessible.

SECTION ROOF SPECIALTIES

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Project Number BID NO. CAG 18 2 ROOF REPLACEMENT FOR HARFORD COUNTY PUBLIC SCHOOLS NORTH HARFORD ELEMENTARY. Addendum # 2

Metal Roofing. The Devil is in the Details SSRLU3B. I LU/HSW Hour

Duro-Last Roofing System. Protecting Your Investment

ROOF SUBSTRATE PREP MANUAL

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate

GAF EnergyGuard Polyiso Wall Sheathing

about your house Before You Start Repairing or Replacing Roof Finishes Figure 1 Common problems

A. Submit product data sheets and literature verifying physical properties of materials.

ADDENDUM. ADDENDUM NO. 2 October 19, 2017

Section X - Miscellaneous

Section 32 - Miscellaneous

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SUBMITTALS Descriptive literature: Submit manufacturer's application instructions and technical data sheets or catalog cuts on materials.

WeatherSmart Air Barrier Installation Guide

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

bout your house before you start Repairing or Replacing Roof Finishes

TYPICAL ROOF CONDITION LAYOUT

SITE AND BUILDING INSPECTION CHECKLIST

Existing Roof Assembly Information. 2 nd Roof Assembly

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO

the re-cover option, there are several elements to keep in mind to achieve proper longevity of the new roof system. Replacement vs.

REROOFING ANALYSIS OF K-12 BUILDING. Unified School District 306 Gypsum, Kansas

SPRI Updates and Improves Roof Edge Standards

September 30, Mr. Michael E. Melnick Permanent Building Committee 278 Old Sudbury Road Sudbury, MA 01776

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

Radon Vent Pipe System. Labeling Performance Indicators

National Property Inspections

V.I. Inspections Page 1 of 15 21:04 September 18, 2018

PHILMONT WAREHOUSE BUILDING PRELIMINARY STRUCTURAL ASSESSMENT

ADDENDA #5- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

1 Firestone EPDM Roofing Systems

ADDENDUM # 2. - Page 1 of 2

SECTION SINGLE-PLY ROOFING SYSTEM

Shepard & Associates, LLC

Shepard & Associates, LLC

Warranty and Inspection Requirements & Procedures

Metal to the metal. by W. Lee Shoemaker, Ph.D., P.E. and Vincent E. Sagan, P.E. and Dale Nelson

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Options In Flashing for Asphaltic and Single-Ply Systems Brochure

CCIM Central Canada Chapter. Richard Weldon, P.Eng., LEED AP Carson Dunlop Weldon & Associates Ltd. October 5,

Transcription:

Lithia Dodge East 5500 L St. Omaha, NE

Perimeter Photos Failed Joints at North Rear Wall Control Joints Look Good Inadequate Downspout Elbows Erosion Along Wall Minor Efflorescence

Roof Section Photos Roof Overview Section 1 Missing Coping Stone Existing Coping Stone Still Usable Water Evidence in Block Below Missing Coping Missing Roof Jack Cap Nicely Flashed and Installed HVAC Details

Roof Section Photos Roof Overview Section 2 Nicely Flashed and Installed HVAC Details Nicely Flashed and Installed Cap Metal

Roof Section Photos Roof Overview Section 3 Pulling Membrane at Vertical Wall (North) Pulling Membrane at Vertical Wall (East) Membrane Pulling Against Metal Flashings Pulling At Curb Pulling at Curb

Roof Section Photos Ponding at Gutter Edge (Poor Detail) Missing Roof Jack Cap Roof Overview Section 3 Minor Rusting at Seams (Typical) Possibly Vandalized HVAC Unit Possibly Vandalized HVAC Unit

Rusting Panel Behind HVAC Unit Roof Section Photos

Roof Section Summary Roof System: Roof sections 1,2 and 4 use a Trapezoidal Standing Seam Metal System. Water flows at approximately 2 per foot to gutters and downspouts. Section 3 uses a Ballasted EPDM system with insulation on a metal deck. Water flows at approximately 1/2 per foot to an internal gutter. Roof Evaluation Section 1 is in good condition overall. The metal has virtually no rusting and field seams look good. There are fasteners in places that have lifted, but this is not uncommon for a roof of this age. The ridge has gaps where each panel seam enters the ridge cap because the gasket seals of this detail have aged and worn out. Again, this is not uncommon for a roof of this age and does not necessarily mean that leaking is occurring. A roof jack (furnace stack) cap is missing. This is certainly letting water into the HVAC system. A coping stone on the northwest corner has detached and fallen on to the roof field. This has exposed the parapet wall masonry to water. Water penetration into the masonry can be seen on this corner all the way down the wall with darker wet spots along the top half of the wall and efflorescence (white mist) in the block towards the bottom of the wall. The rear block wall itself is in good condition. Control joints in the block look good. There just a few failed joints just below the gutter run. Downspouts do not have adequate extensions and water is running along the base of wall. This is causing erosion along this detail. Section 2 is in excellent condition. The field is rust free and panel seams look excellent. The parapet walls on this section nicely and properly flashed with EPDM membrane and topped with cap metal. HVAC units were nicely flashed with crickets to direct water around them. A very nice installation. Section 3 is in good condition overall. The roof has good slope which really helps a roof s life expectancy. The field is loaded with skylights which is often a liability from a roofing perspective but these were nicely flashed at the time of installation and the skylight metal components look to be in nice shape as well. Two of these skylight curbs have heavily pulled EPDM membrane. The entire north vertical wall and entire east parapet wall have significantly pulled membrane. It is pulling to a point where it is pressing against the metal wall flashing above and could cut open in the future. Pulling is very common with Ballasted systems. At the gutter edge, a metal gravel stop edge was installed along the entire run instead of installing drain bar. This was a poor idea. The raised 2 edge of the gravel stop negates some of the great roof slope and is causing water to pond along this edge. Slots were cut in, but this is not sufficient and leaves more opportunities for failures in the future. This edge will deteriorate faster than other components of the system, but is acceptable for now. It should be noted that a far better design in the future will be to install a Fully Adhered EPDM system. First of all, the roof s relatively small size would have made upgrading to a fully adhered roof quite inexpensive. This would have eliminated any realistic possibility of pulling (especially with all the curbs that exist on this little roof). Finally, a fully adhered roof would have eliminated the need for drain bar or gravel stop edge at the gutter, allowing clear water flow to the internal gutter. This internal gutter likely has freeze problems in the winter. Finally, a roof jack cap is missing on this section. Section 4 is in excellent condition. There is minor rusting starting at the field seams, but this can be monitored year and could be coated in 5-7 years to extend the system for another 10 years. A large HVAC unit has fallen panels and some wind damage. The panels are on the roof field. A condensation line from this unit is causing significant surface rust down one panel as the water from the unit runs down it to the gutter.

Roof Section Summary Recommendations: Section 1 should have the existing coping stone secured back on the parapet wall and sealed. Any masonry joints directly below this detail that have failed because of this should be cleaned and sealed as well. The missing roof jack cap on section 1 should be replaced and properly secured. It would also be advisable to add downspout extensions to direct water away from the foundation. The rear block wall should have the few runs of failing joints filled with sealant. Budget number for this work would be $900. Section 2 has no immediate work needed. Section 3 should have the north and east vertical walls cut open, the membrane relaxed and new membrane installed and tied into the roof field to alleviate the pulling. RPF strip (a strip that uses fasteners and plates drilled into the masonry) should be installed first to pin the new membrane to the wall to help keep the walls from pulling apart in the future. Merely cutting the rubber and gluing in new membrane up the wall is far cheaper but will pull apart again very easily. Two skylight curbs that are pulling should be reflashed in the same manner. The missing roof jack cap should be replaced. A budget number for all repairs on this section would be $3100. Section 4 should have an HVAC contractor inspect the metal panels to insure that they can be properly resecured or they should be replaced. It would be advisable to have the contractor inspect the entire unit as it appears possible that it was vandalism and not wind that caused some of the damage. An extension hose should be installed on the condensation line and it should be run to the gutter to stop the rusting that is being caused on that metal roof panel. Estimated Life: Section 1: The roof should perform for another 10+ years. Section 2: The roof should perform for another 10+ years. Section 3. The roof should perform for another 7-9 years with reflashing repair. Section 4: The roof should perform for another 10+ years.