D.I.Y DAMP COURSING APPLICATION INSTRUCTIONS

Similar documents
Outward Folding Bathscreen Instruction Manual

1850 x 40/50mm Raised Shower Tray Kit

DEEP SOAK PRODUCT REQUIREMENTS. A. Product Requirements. B. Product Inspection. C. Clearance Requirements T01-A

Matrix Helical Anchoring System

30mm Height Linear Drain Shower Trays

TREAT RISING DAMP AND REDECORATE IN UNDER 24HRS

Model No. BWTDWFK-TRIFLO.

Concrete 1,8 2,0 Anidrite 0,3 0,5

INSTALLATION INSTRUCTIONS

Mega Clic Laminate Floor Installation Instructions

... Targeted treatment for Rising Damp... F A S T C L E A N E F F E C T I V E

Multi-Piece Shower with Trench Drain

fusion shower pan on wood joists installation guide

HomeGuard Precision Termite Management

Important Information

Cem-fix Wallfast Ltd SALES Tel

LAHAINA. Lahaina Showerspa Model #1030 Installation Instructions

BETAFRAMES. Engineered products for the building industry Solutions without compromise. Industry Knowledge. Flexible Manufacturing.

Cornerview Shower Enclosure & Base

Single-skin, externally reinforced, brick tank. Instructions for manufacture

BioPrism Solid Surface

Fast Cure Acrylic Adhesive

SlimLine Single Threshold Base & Q-Wall-5.1 BASE & BACKWALL INSTALLATION INSTRUCTIONS

Multi-Piece Shower with Trench Drain

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. RobinsonBrick.com

BEFORE YOU BEGIN PRODUCT REQUIREMENTS. A. Summary Of Key Requirements. B. Product Inspection T01-A INSTALLATION INSTRUCTIONS

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

SILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION

Liquid layer sampler, cable operated

adjustable fusion shower pan on wood joists installation guide

TP EA. Product Description. Properties and Benefits. Applications. Reaction Resin Mortar Based on Epoxy Acrylate. Approvals / Certificates:

aquapanel InstallatIon GuIde

Welding & Fabrication Tools Mini VaR Tool Kit

Prime Shower Enclosure & Base Kit

DECKING COMPOSITE. Installation Manual 2016

GUIDE TO DUKKABOARD AQUA 77

CENTRUM CUP STACKER OPERATIONAL INSTRUCTIONS

FLOORING INSTALLATION INSTRUCTIONS

Sheetseal GR RIW. Sheetseal GR

Fosroc Lokfix E75. High performance pure epoxy 3:1 resin cartridge system, for anchoring reinforcement and fixings into a variety of substrates.

Sheetseal 226 RIW. Sheetseal 226

Prime Shower Enclosure & Base

Multi-Piece Shower with Trench Drain

SHOWER SCREEN (8mm) Installation / Maintenance Instructions. Rev Rev 02.12

PUR Sensor Installation with PAGEL V2/40

Instructions for Finishing Heater

adjustable fusion shower pan surface mounted on subfloor installation guide

0331 Brick and block construction

EXIRA EXPOSED PIPE SHOWER INSTALLATION

Synthetic resin against rising damp, heavy moisture penetration and salt contamination. (compared to water: 1 mpa.s)

Air Delivery System. Single: Double: installation instructions

Introduction. Before you begin. Structure installation

Brick Walls MTI. Rainscreen Retrofit for. Flood Recovery Hurricane Recovery Restoration Flood Resilient Retrofit. Guide to Wet Flood-Proofing

INSTALLATION INSTRUCTION (U.S.A) FOR LUMI-O DRY NICHE INGROUND LIGHT.

Installation Guide Acrylic Bath W/O Apron

BETTER BY DESIGN BRICK SLIP MASONRY SUPPORT INSTALLATION INSTRUCTIONS. igmasonrysupport.com

Liner Replacement Instructions:

INSTALLATION INSTRUCTIONS

Brick Works (cont.) Building in bricks: Factors affecting the stability of brick building: Properties of bricks:

4. Floor Substrate Testing Prior to Floor Paint application

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Setting holding down bolts Floor screeds Bedding blocks Stone and bricks In contact with potable water Fine moulding.

PSI Crack Injection Repair Guide. Surface Preparation for Crack Injection

Low-cost, thin-shell, ferrocement tank cover

Instal ation Guide BackboxSW

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Double Tidy Rail. Assembly Instructions- Please keep for future reference. Important - Please read these instructions fully before starting assembly

Installation Guide. Linear Drain Shower bases

SKIRTED BATHTUB INSTALLATION MANUAL

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware

Straight Panel Bath Screen Instruction Manual

COASTLINE ALASSIO Swing Door. Installation & Maintenance Instructions. Rev Lakes. Bathrooms

/503 Level 3 Plastering (Fibrous) Version 1.0 November Sample Marking Scheme

FIS VS 950 S FIS VS 360 S FIS VS 150 C

Smart-Holder. Instruction Manual for North America

One Meter Internal Dome Oven AVERAGE GUIDE

EMERALD ROUGHING-IN. A. Summary Of Key Requirements. B. Product Inspection. A.Ordering Information: A. : T01-B 1 INSTALLATION INSTRUCTIONS

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED TEN66 SUB-FRAME SYSTEM

Building Regulations

premium click optimum click

hard to the core EXTREME PERFORMANCE CORE DRILL BITS

Installation Instructions

Introduction. A publication by Aquamor

2. Install the front plate insulation

The gable wall of one of the test houses is of brick/foam-filled cavity/block/air gap/plasterboard construction typical of many modern houses

Build Your Own. Biogas Generator. Basic Principles

Building Construction 7. Dr Nabil El-Sawalhi Associate professor Engineering Projects Management

Installation Instructions DEKO PV 1090

Sormat ITH-Pe PRODUCT DATA SHEET. ITH-Pe - POLYESTER BASED RESIN STYRENE FREE. Polyester based injection resin, styrene free. ITH 165 Pe art.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

SlimLine Neo-Angle Base & Q-Wall-2

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

K17 Insulated Plasterboard

Niagara / DLG-85 Shower Cabin Installation and User s guide

Heat-Kit System Modular Contraflow Masonry Heater Core Assembly Manual

DETAIL INSTRUCTION No. 1

Inject-TITE AW All-Weather

KWiK N EZ Rigid Track Silicone System

PITTSBURGH CORNING ASSEMBLY INSTRUCTIONS. KWiK N EZ Rigid Track Silicone System for Thinline Series Glass Block

5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE

Transcription:

D.I.Y DAMP COURSING APPLICATION INSTRUCTIONS The Tech-Dry applicator kit makes it easy to install a damp course into single and double brick walls. Each kit contains enough re-useable applicators to treat 3 metres of single brick wall (or 1.5 metres of double brick wall) at one time. Filling each reservoir with 150ml of DAMP COURSING FLUID is enough to thoroughly saturate a single brick thickness of wall. Follow the step-by step instructions outlined below. It is strongly recommended that you first attempt an installation on two bricks to ensure that you have the correct technique for your wall and brick type! DRILLING CORRECT HOLE SIZE It is important that you drill the correct diameter hole in the bricks, this will provide a leak-free seal between the hole and the applicator nozzle. The aim is to produce a hole that provides a snug, push fit, of the sealing tube inside the hole (as shown below). The correct hole diameter is generally 10mm. If you have very soft bricks you may need to drill 9mm, if you have very hard bricks you may need to drill 11mm. In any case a snug fit of the sealing tube inside the hole is required. Make sure the sealing tube is a firm fit in the drilled hole! DRILLING METHODS The drilling method varies slightly depending on the type of bricks present. Select the type of bricks and drilling method from the list below. VERY SOFT AND NOT SO WET BRICKS These types of bricks are usually found in Victorian houses. The bricks are easy to drill and the drill dust comes out of the hole as a dry dust (it is not wet enough to form clumps when squeezed in the hand). 1) Carefully remove the skirting boards from the wall using a flat pinch bar. 2) Remove any render covering the lowest course of bricks so that the entire brick face and surrounding mortar is clearly visible.

2. 3) Using a 10mm diameter masonry drill bit (see section entitled "CORRECT HOLE SIZE" above), drill two blind holes in each brick at floor level using a sturdy hammer drill. The holes should start at the mortar line level and be drilled down into the brick at an angle of approximately 45 degrees. The spacing of the holes along the wall should be 120mm as shown below. The depth of the holes should be about 90mm, take care not to drill through or break the brick. If a hole is inadvertently drilled through the brick, a new hole should be drilled beside it. Remove the dust from the holes using a vacuum cleaner. Hole Ends In Brick VERY HARD OR WET BRICKS If you have soft bricks, which are very wet (the drilling dust does not look like a free-flowing dust but clumps together), use this drilling method. This method should also be used for very hard bricks. Very hard bricks are found in houses built from about 1900 to the present. Clinker bricks and pressed clay bricks are hard bricks. 1) Carefully remove the skirting boards from the wall using a flat pinch bar. Drill Holes at 120mm Centres 2) Remove any render covering the lowest course of bricks so that the entire brick face and surrounding mortar is clearly visible. 3) Using a 10mm diameter masonry drill bit (see section entitled "CORRECT HOLE SIZE" above), drill two blind holes in each brick at floor level using a sturdy hammer drill. The holes should start at the mortar line level and be drilled down through the brick until the drill bit reaches the mortar line below. The hole should end in the mortar line halfway through the thickness of the wall. Drill at an angle of approximately 45 degrees. The spacing of the holes along the wall should be 120mm. Remove the dust from the holes using a vacuum cleaner. NOTE: If mortar is missing between bricks, re-mortar the missing areas, let the mortar set, and proceed with the damp coursing. Drill Hole Ends In Mortar Line

3. WIRE CUT BRICKS Wire cut bricks are bricks with holes in them. These types of bricks are commonly found in properties built after about 1970. These bricks are usually found in brick veneer construction or on the outside leaf of cavity walls. The method of drilling for this type of brick is as follows: 1) Remove any render covering the lowest course of bricks so that the entire brick face and surrounding mortar is clearly visible. 2) Using a 10mm diameter masonry drill bit (see section entitled "CORRECT HOLE SIZE" above), drill two holes in each brick at floor level using a sturdy hammer drill. The holes should start at the mortar line level and be drilled until the drill bit enters the holes in the bricks. The drilling angle should be approximately 45 degrees from the horizontal. The spacing of the holes along the wall should be 120mm, roughly 2 per brick. Holes in wire cut Bricks WALL TYPES There are three types of wall that can be treated with the Tech-Dry D.I.Y. system. The walls are single brick, solid double brick and cavity wall (shown below). Single brick walls can be treated from the most convenient side. Solid double brick and cavity walls must be treated from both sides. SINGLE BRICK WALL (Treat from most convenient side) SOLID DOUBLE BRICK (Treat from both sides) CAVITY WALL (Treat from both sides) Check that cavity is clear

. 4. INSTALLING THE APPLICATORS AND APPLYING THE DCF INSTALLING THE RESERVOIRS 1) A coil of sealing tube has been supplied. This should be cut into 40 mm lengths and pushed 20mm into the drilled hole. The tube should be a snug fit in the hole (see section entitled "CORRECT HOLE SIZE"). 2) Push and turn the applicator nozzle into the tube fitted into the drilled hole. The tapered nozzle should wedge into the inside of the tube, forming a seal that stops the leakage of fluid. 3) Using a sharp knife cut off the conical section of the reservoir end so that the DAMP COURSING FLUID can flow into the applicator nozzle. 4) Slip the sealing ring into position over the applicator nozzle as shown in the attached sheet. This ring stops the reservoir from leaking. 5) Screw the reservoir firmly into the applicator nozzle. DO NOT over-tighten! Make sure the sealing tube is a firm fit in the drilled hole! Gently push & twist applicator nozzle into place so as to achieve a firm fit. End of reservoir must be cut open Sealing Ring Ensure reservoir is firmly fitted to nozzle, do not over-tighten!

5. FILLING THE RESERVOIRS 1) Fill each reservoir with 150ml of the DAMP COURSING FLUID using the jug supplied. The fluid level should gradually get lower as the fluid is absorbed into the brickwork. No fluid should be leaking from the seal between the hole and the applicator nozzle or the junction between the application nozzle and reservoir. If a large amount of fluid is leaking from either of these two points, re-set the applicator nozzles and reservoirs as per instructions 1-5 in "Installing The Reservoirs". If the applicators still leak between the hole and the sealing tube, wrap a few turns of Teflon tape around the sealing tubes so as to form a good seal in the hole. One 150ml fill of each reservoir normally delivers enough fluid (1.5 litres per metre of single brick wall) to completely saturate a single brick thickness of wall. The DAMP COURSING FLUID should take from 3 hours to 15 hours to completely permeate into the bricks and surrounding mortar. A darkening of the bricks and surrounding mortar marks the progress of the installation. Where the drill hole ends in the mortar line (as for very hard or wet bricks), fill each reservoir three times with 50ml of the DAMP COURSE FLUID (150ml in total for each reservoir). Only fill a reservoir when the previous 50ml of fluid has drained out of the reservoir. The fluid will run out of the reservoir very quickly, this is normal, as mortar lines are very permeable. There should be a darkening of the entire lower mortar line after a few hours. Once the DAMP COURSING FLUID has impregnated the bricks in a complete horizontal layer, the wall above this layer will begin to dry out. Fill with150 ml of fluid

6. REMOVAL OF THE APPLICATOR NOZZLES AND RESERVOIRS Once the Tech-Dry damp course has been installed into the section of wall, the applicators can be removed. 1) Each reservoir should be unscrewed from the applicator nozzle. 2) Remove the applicator nozzle from the wall by turning the applicator while gently pulling. The sealing tube usually remains in the hole and can be removed by pulling it out of the hole with a pair of pliers. 3) The applicator nozzles and reservoirs can now be re-used on the next section of wall. The installation of the damp course is now complete and the wall will begin to dry out. Refer to page 2 of the data sheet on DAMP COURSING FLUID for instructions on what to do after the damp course has been installed. THIS APPLICATION KIT CONTAINS THE FOLLOWING COMPONENTS Building Protection Systems Pty. Ltd 177-179 Coventry Street South Melbourne, Victoria, 3205 Tel. (03) 9699 8202 Fax. (03) 9696 3362