Monosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD

Similar documents
In-Cell and External Hydrolysis of Biomass for Carbohydrate Determinations Using Automated Solvent Extraction

New Developments in Capillary Ion Chromatography Systems with Electrochemical Detection and Their Applications

Analysis of Fracking Flowback Water From the Marcellus Shale Using In-line Conductivity, Automated Dilution, and Ion Chromatography

Glycoprotein Monosaccharide Analysis Using HPAE-PAD with Eluent Generation

Dual EGC A simple solution for complex carbohydrate analysis

Highlighted Capillary IC Applications

HPAE-PAD analysis of Carbohydrates. Michael G. Hvizd Manager, Laboratory Operations Centers of Excellence Dionex Corporation Laboratory

Implementation of a Walk-Up High- Pressure Capillary Ion Chromatograph for the Fast Separation of Pharmaceutical Relevant Inorganic Anions and Cations

Determination of Inorganic Anions in Acid Rain Using a Dedicated High-Pressure Capillary Ion Chromatography System

HPAE-PAD analysis of galactosyl-oligosaccharidecontaining samples using dual eluent generation cartridges

The Benefits of SOLAμ Technology in Sample Preparation. Jon Bardsley and Ken Meadows Thermo Fisher Scientific, Runcorn, UK

Improved Method for Determination of Biofuel Sugars by HPAE-PAD

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Introduction. Yan Liu, Victor Barreto, Rosanne Slingsby, Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA

Thermo Scientific Dionex ICS-900 Ion Chromatography System

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water. Pranathi R Perati Thermo Fisher Scientific, Sunnyvale, CA, USA

The Effect of Working Electrode Gasket Thickness on the Sensitivity and Linearity of Carbohydrate Response by Pulsed Amperometric Detection

High-speed, High-resolution Oligonucleotide Separations Using Small Particle Anion-Exchangers

Effect of Temperature on IC Signal Noise

Determination of Glycoprotein Monosaccharide Composition by HPAE-PAD Using On-Line Electrolytically Generated Eluents

Be a pioneer. Thermo Scientific Dionex ICS-6000 HPIC system the freedom to explore

Thermo Scientific. Dionex CarboPac SA10. Column Product Manual. P/N: July Part of Thermo Fisher Scientific

Minimizing Carbon Dioxide Contamination in Anion Reagent-Free Ion Chromatography

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

Chromatography column for therapeutic protein analysis

Direct Carbohydrate Analysis in Beverages and Foods Using Pulsed Amperometric Detection or Charged Aerosol Detection

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Direct Carbohydrate Analysis in Beverages and Foods Using Pulsed Amperometric Detection or Charged Aerosol Detection

Errata. Product Manual for Dionex CarboPac PA20 Columns

Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity

Dionex Eluent Generator Cartridges

Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters Using a Compact Ion Chromatography System

Be a pioneer. Thermo Scientific Dionex ICS-6000 HPIC system the freedom to explore

columnsi o n P a c C S 1 6 C a t i o n - E x c h a n g e C o l u m n

ph gradient analysis of IgG1 therapeutic monoclonal antibodies using a 5 µm WCX column

Practical guidance for switching between anion and cation analysis systems

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Fast Ion Determinations and Efficient Separations of Complex Samples Using 4 µm Particle-Size Ion Exchange Columns

CarboPac PA200 Columns For Dual EGC ICS-6000 For Research Use Only. Not for use in diagnostic procedures.

A Novel ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge-Variant Analysis

High-Resolution Separation of Intact Monoclonal Antibody Isoforms

PRODUCT MANUAL. for the

Determination of Manganese in Brine ( 30% NaCl)

Methods for Determining Sugars and Hydroxymethylfurfural in Biomass

Jonathan R. Beck and Charles T. Yang; Thermo Fisher Scientific, San Jose, CA

DNAPac PA200 and PA200 RS Columns Solutions for Nucleic Acid Analysis

Thermo Scientific Dionex ICS-4000 Integrated Capillary HPIC System. Always ready, better results. capillary high-pressure ion chromatography

Monosaccharides. Robust Applications, Fluidly Running. Introduction. Application Note Clinical/Pharma/ Food/Life science

Analysis of Monoclonal Antibody and Related Substances using a New Hydrophobic Interaction Chromatography (HIC) Column

Configuring a High-Pressure Dedicated Capillary IC System for Electrochemical Detection

Next generation suppressor for ion chromatography. Thermo Scientific Dionex ERS 500 Electrolytically Regenerated Suppressor

Carbohydrate Analysis in Beverages and Foods Using Pulsed Amperometric Detection or Charged Aerosol Detection

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Thermo Scientific EASY-Spray Technology. Plug-and-spray with. State-of-the-art performance

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION

High-Resolution Charge Variant Analysis for Top-Selling Monoclonal Antibody Therapeutics Using a Linear ph Gradient Separation Platform

High-Throughput Oligonucleotide Analysis on a Small Particle Pellicular Anion-Exchanger

columns IonPac ICE-AS1 Ion-Exclusion Column Superior Chromatographic Performance Separates weakly ionized acids by differences in pk a

Monoclonal Antibody Analysis on a Reversed-Phase C4 Polymer Monolith Column

Thermo Scientific Dionex ICS HPIC Capillary and Analytical System. High resolution, fast analysis high-pressure ion chromatography

Determination of Cations in Hydraulic Fracturing Flowback Water from the Marcellus Shale

Options Eluent Regeneration (RFIC-ER ) Column Heater In-Line Vacuum Degas Full Chromeleon Chromatography Data System

A HIGHLY VERSATILE IC SYSTEM CAPABLE OF EVERY CHALLENGE THAT COMES YOUR WAY THERMO SCIENTIFIC DIONEX ICS HPIC SYSTEM

Passion. Power. Productivity. Corporate Headquarters

electrochemical detection

HIGH QUALITY, RELIABLE ION ANALYSIS SOLUTIONS FOR EVERY IC CHALLENGE THERMO SCIENTIFIC DIONEX PRODUCT PORTFOLIO

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

Determination of Sulfite in Food and Beverages by Ion Exclusion Chromatography with Pulsed Amperometric Detection

Assay for Citrate and Phosphate in Pharmaceutical Formulations Using a High-Pressure Compact Ion Chromatography System

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

for water and beverage analysis

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Thermo Scientific MAbPac HIC Columns. Novel Hydrophobic Interaction HPLC Columns. Designed for Monoclonal Antibody Analysis

ProPac Elite WCX, 5 μm Particle, for Fast, High Resolution Protein and mab Analysis. July 2018

Optimize Your Process Operations by Improving Process Monitoring

Complete Customer Support

Thermo Scientific Dionex DRS 600 Dynamically Regenerated Suppressor

with High Pressure Sponsored content from Presented in partnership with

Analysis of Monoclonal Antibodies and Their Fragments by Size Exclusion Chromatography Coupled with an Orbitrap Mass Spectrometer

Nitrogen Determination in Soils and Plants by Flash Combustion using Argon as Carrier Gas

MAbPac RP Column. High-performance reverse phase chromatography column for monoclonal antibody analysis

Parallel LC with Capillary PS-DVB Monolithic Columns for High-Throughput Proteomics

Method Optimisation in Bottom-Up Analysis of Proteins

Dionex IonPac AS16 Column

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

Determination of Perchlorate in Drinking Water Using a Reagent-Free Ion Chromatography System

columns PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns

Abstract. 1. Introduction

Nuvia HR-S Strong Cation Exchange Media Instruction Manual

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

Heparin Sodium - USP method

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Transcription:

Monosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD

A large number of innovator biotherapeutics are currently losing patent protection, resulting in an increased interest to develop biosimilar therapeutic proteins. A key step to proving biosimilarity is to ensure proper N-glycosylations, because variations in glycosylation can affect the efficacy and safety of therapeutic proteins, influencing their biological activity, serum half-life, and immunogenicity. Monosaccharides, including sialic acid composition analysis can detect variations in glycosylation, and support quality control for process development and manufacturing procedures. As a result, proteins are routinely analyzed to determine their monosaccharides and sialic acids amount and identity. High-performance anion-exchange chromatography with pulsed amperometric detection (HPAE-PAD) is a well-established method for carbohydrates analysis. HPAE-PAD separates carbohydrates with specific interactions between the hydroxyl and carboxyl groups of carbohydrates based on charge, size, composition, isomers, and linkages. Therefore, HPAE-PAD is the best method for monosaccharides, sialic acids, and other carbohydrates analysis. Direct detection - no sample derivatization required saving analyst time, expense and exposure to hazardous chemicals Ultra-selective, sensitive detection Fast separations without loss of resolution using Thermo Scientific Dionex CarboPac PA0 Fast columns

Glycoprotein Monsaccharide Analysis Using HPAE-PAD with Eluent Generation Rapid Screening of Sialic Acids in Glycoproteins by HPAE-PAD Evaluating Protein Glycosylation in Limited-Quantity Samples by HPAE-PAD Sialic Acids in Glcoprotein Hydrolyzates by HPAE-PAD

Glycoprotein Monsaccharide Analysis Using HPAE-PAD with Eluent Generation Characterization of glycoproteins routinely involves carbohydrate analysis. Minor variations in glycosylation can affect the efficacy of protein therapeutics. Monosaccharide composition analysis can detect variations in glycosylation, and support quality control for process development and manufacturing procedures. There are over 30 approved glycoproteinbased biodrugs on the market and the number is increasing rapidly. Agencies such as the U.S. FDA and the European Medicines Agency have increased pressure on biopharmaceutical manufacturers to demonstrate satisfactory programs for understanding, measuring, and controlling glycosylation in glycoprotein-based drugs. Conditions Columns: Eluent: Eluent Source: Flow Rate: Inj. Volume: Column Temp.: 30 ºC Cell Temp.: 30 ºC Backpressure: Detection: Background: Working Electrode: Reference Electrode: Dionex CarboPac PA0 Analytical, 3 50 mm Thermo Scientific Dionex AminoTrap, 3 30 mm 0 mm KOH Thermo Scientific Dionex EGC III KOH Eluent Generation Cartridge Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column 0.5 ml/min 0 μl (partial loop injection mode with a 4 μl cut volume) 00 psi PAD 30 50 nc Carbohydrate PTFE Disposable Au Working Electrodes Mode: Ag/AgCl mode Noise: 0 30 pc In this technical note, the HPAE-PAD-based method on a Thermo Scientific Dionex ICS-5000 chromatography system for monosaccharide composition analysis is fast and capable of providing reproducible retention time and detector response for hundreds of samples over several days. The disposable Au working electrode contributes to the reproducibility of PAD between electrodes and between laboratories. The method has high sample throughput, high precision and performance ruggedness for glycoprotein monosaccharide analysis. 80 nc 30 60 nc 36 Sample: IgG TFA Hydrolysate Sample: IgG HCl Hydrolysate Monosaccharide composition analysis of human serum IgG. 3 4 5 0 3 4 5 6 7 8 9 0 3 Minutes Peaks:. Fucose. Glucosamine 3. Galactose 4. Glucose 5. Mannose 4 Download the Technical Note 40: Glycoprotein Monsaccharide Analysis Using HPAE-PAD with Eluent Generation

Rapid Screening of Sialic Acid in Glycoproteins by HPAE-PAD Glycoprotein sialylation has been shown to be critical to bioavailability, stability, metabolism, and immunogenicity of therapeutic proteins. As a result, such proteins are routinely analyzed to determine sialylation amount and identity. Although over 50 forms of sialic acid have been identified, two forms of this carbohydrate are routinely determined, N-acetylneuraminic acid (Neu5Ac) and N-glycolylneuraminic acid (Neu5Gc). Of these, Neu5Gc is generally not found in human proteins. Due to this lack of Neu5Gc in healthy human tissue and the natural occurrence of antibodies against Neu5Gc, this sialic acid has the potential to cause an immune response in patients when present in a glycoprotein therapeutic. Conditions Column: Eluent Gradient: Eluents: Flow Rate: Injection Volume: Dionex CarboPac PA0 Fast Sialic Acid, 3 30 mm 70-300 mm acetate in 00 mm NaOH from 0.5 min, 300 mm acetate in 00 mm NaOH from.5.9 min, 300 70 mm acetate from.9 3.0 min.5 min of equilibration at 70 mm acetate in 00 mm NaOH A: 00 mm NaOH, B:.0 M sodium acetate in 00 mm NaOH 0.5 ml/min Temperature: 30 C Detection: Background: Noise: Backpressure: 4.5 μl (full loop) Pulsed amperometric, disposable Au on PTFE working electrode 8 5 nc (using the carbohydrate waveform) ~5 30 pc ~750 psi In this application update, sialic acids are determined in five representative glycoproteins by acid hydrolysis release followed by HPAE-PAD. The method is both specific and direct, eliminating the need for sample derivatization common in other chromatographic methods. Good recoveries, precision, and linear detection for Neu5Ac and Neu5Gc are demonstrated, indicating the method is appropriate for glycoprotein analysis. Peaks: A B C. Neu5Ac 9.8 6.3 5.6 pmol. Neu5Gc 0.7 0.93 38 nc 6 A B C 5% signal offset applied 0 3 Minutes Separation of fetuin, h. AGP, s. AGP hydrolyzates (:00 dilution) on the Dionex CarboPac PA0 Fast Sialic Acid column. Download the Application Update 8: Rapid Screening of Sialic Acids in Glycoproteins by HPAE-PAD

Evaluating Protein Glycosylation in Limited-Quantity Samples by HPAE-PAD Changes in protein glycosylation are frequently studied in cancer research to identify potential biomarkers. Factors investigated include differences in overall oligosaccharide (glycan) content, monosaccharide content changes, differences in sialylation amount and sialylation linkages, the degree of fucosylation, and differences in glycan branching. PSA is an example of a well known glycoprotein cancer marker. The glycosylation of this protein is of importance as researchers seek to understand the changes that occur in this protein during carcinogensis and tumor growth to provide a greater understanding the of the disease. In this study, the glycosylation of human transferrin (as a model of PSA) and PSA are investigated by HPAE-PAD using <0 µg of protein. Two methods are utilized to evaluate protein glycosylation. One method is used to investigate the N-linked oligosaccharides and glycan sialylation. A second method evaluates the potential presence of O-linked glycans by monitoring monosaccharide composition. By using a combination of acid hydrolysis and enzymatic digestion steps prior to HPAE-PAD analysis, information about the glycosylation, as well as linkages within the glycans, is determined. Conditions Monosaccharides 3 Columns: Eluent: Eluent Source: Flow Rate: Inj. Volume: Temperature: Detection: Background: Noise: System Backpressure: Thermo Scientific Dionex AminoTrap *, 3 x 30 mm Dionex CarboPac PA0 Analytical, 3 x 50 mm 0 mm potassium hydroxide (KOH) Dionex EGC III KOH Cartridge with Dionex CR-ATC Continuously Regenerated Anion Trap Column 0.5 ml/min 5 μl (partial loop) 30 ºC (column and detector compartments) * Installed before the Dionex CarboPac PA0 column Pulsed amperometric, disposable Au on PTFE electrode ~30 nc ~0 pc ~00 psi Samples: Hydrochloric acid hydrolyzates of A) 0.67 μg PSA, B) PSA glycans after PNGase F release (equivalent to 0.09 μg of protein), and C) monosaccharide standards A B C Peaks:. Fucose ND ND 5 pmol. Galactosamine.6 0.3 5 3. Unknown 4. Glucosamine 4.5 5 5. Galactose N/A N/A 5 6. Glucose N/A N/A 5 7. Mannose ND ND 5 ND = Not Determined 45 A nc B C 3 4 5 6 0% signal offset applied 34 3.5 5 7.5 Minutes 0 4 4 5 6 Separation of PSA acid hydrolysates on a Dionex CarboPac PA0 column. Both the total protein hydrolysis and the PSA-N-linked glycans have a similar ratio of galactosamine/glucosamine of 0.07. The hydrolysis conditions here do not allow reliable quantification of galactose and glucose. 7 Download the Application Note 050: Evaluating Protein Glycosylation in Limited-Quantity Samples by HPAE-PAD

Sialic Acids in Glycoprotein Hydrolyzates by HPAE-PAD Sialic acid determination can be performed by many methods. Typically, sialic acids are released from glycoproteins by acid hydrolysis or by enzymatic digestion before analysis. Once the sialic acids are liberated, there are many options for quantification. Numerous spectroscopic methods exist, although interferences in these methods can cause overestimation of the concentration of sialic acids in many samples. Therefore, chromatographic methods that separate the sialic acids from potentially interfering compounds are preferred. Among the chromatographic methods, there are thosethat require further sample derivatization for analyte detection, such as fluorescent labeling followed by high-performance liquid chromatography (HPLC), and direct detection methods such as HPAE-PAD. Of these methods, HPAE-PAD offers the advantage of direct analysis without sample derivatization. 65 nc E) D) C) B) A) Peaks: A) B) C) D) E). Neu5Ac.7 4.4 8 5 37 pmol. Neu5Gc. ND 0.39.6 ND 35 0 3 6 9.5 Minutes Sialic acid determination of five glycoprotein acid hydrolyzates. A 0% signal offset has been applied In this work, sialic acids are determined in five representative glycoproteins by acid hydrolysis release and HPAE-PAD. Determination of the sialic acids Neu5Ac and Neu5Gc by HPAE-PAD on a Dionex CarboPac PA0 column is specific and direct. After sample hydrolysis or enzymatic treatment, there is no need for further sample derivatization. Disposable Au on PTFE working electrodes with a four-week lifetime simplify system maintenance compared to conventional gold electrodes. The gradient method discussed separates Neu5Ac and Neu5Gc with a total analysis time of 6.5 min, which is faster than previous methods, allowing greater sample throughput. Conditions Columns: Eluent Gradient: Eluents: Flow Rate: Temperature: Inj. Volume: Detection: Background: Noise: System Backpressure: Dionex CarboPac PA0, 3 50 mm Dionex CarboPac PA0 Guard, 3 30 mm 70 300 mm acetate in 00 mm NaOH from 0 7.5 min, 300 mm acetate in 00 mm NaOH from 7.5 9.0 min, 70 mm acetate in 00 mm NaOH from 9.0 9.5 min, 7 min of equilibration at 70 mm acetate in 00 mm NaOH A: NaOH, 00 mm B: Sodium acetate,.0 M, in 00 mm NaOH 0.5 ml/min 30ºC (column and detector compartments) 0 μl Pulsed amperometric, disposable Au on PTFE electrode 8 5 nc (using the carbohydrate waveform) ~5 30 pc ~3000 psi Download Application Update 80: Direct Determination of Sialic Acids in Glycoprotein Hydrolyzates by HPAE-PAD

HPAE-PAD Technology Overview Electrochemical Detection and Dionex CarboPac Columns

HPAE-PAD High-Performance Anion-Exchange Chromatography HPAE chromatography can be used to separate analytes that can be ionized under high ph conditions. Carbohydrates typically have pkas in the range of 3. Once the ph rises above the pka of the analyte, it becomes ionized in solution. This is accomplished using hydroxide-based eluents. And with the development of highly cross-linked, ethylvinyl benzene-divinyl benzene pellicular resins that have broad ph stability (0 to 4), separations at high ph conditions are feasible. The columns nonporous resins have small anion-exchange microbeads carrying the anion-exchange functional groups which are permanently attached electrostatically to a larger cation-exchange resin particle. The nonporous nature of the resin minimizes band-broadening and imparts highly effective separation of a wide variety of carbohydrates, including branched oligosaccharides. Pulsed Ampermometric Detection The detection of underivatized analytes can be achieved using pulsed amperometric detection. The potential variations are known as a waveform. The variations result in oxidizing and reducing conditions on the electrode surface, which in turn causes the oxidation of analytes bound to the working electrode surface. Pulsed amperometry detects only those compounds that contain functional groups which become oxidized at the detection voltage employed. Detection is sensitive and highly selective for electroactive species, since many potentially interfering species cannot be oxidized or reduced, and are not detected. It is also important to note that neutral or cationic sample components in the matrix elute in, or close to, the void volume of the column. As a result, the carbohydrate components of interest are not impacted even if the neutral or cationic sample components are oxidized.

Technology Overview Dionex ICS-5000 + HPIC and Dionex ICS-4000 Capillary HPIC Systems The Thermo Scientific Dionex ICS-5000 + HPIC and Thermo Scientific Dionex ICS-4000 Capillary HPIC systems are ideal for ionexchange chromatography of carbohydrates using electrochemical detection. With completely metal-free, all PEEK flowpaths, ion chromatography (IC) systems eliminate the possibility of metal contamination and improve robustness. The analysis of mono- and disaccharides can be performed using Reagent-Free IC (RFIC ) systems with eluent generation that only requires deionized water to electrolytically generate the eluent. This technology provides consistent results and the highest reproducibility, day-to-day, user-to-user, and lab-to-lab. The all-peek pump of the Dionex ICS-5000 + system is capable of performing quaternary gradients at high flow rates, for demanding application needs. The Dionex ICS-5000 + HPIC and the Dionex ICS-4000 Capillary HPIC systems use 0.4 mm i.d. columns with /00th the cross-sectional volume of 4 mm columns, requiring only /00th the sample size and using only /00th the eluent. Reduced eluent usage means reduced labor, reduced waste, and reduced operating costs. Capillary HPAE-PAD Capillary HPAE-PAD is a technique that uses capillary columns (e.g., 0.4 mm i.d. columns) packed with ion-exchange resin and a capillary amperometric cell with a gold working electrode and a palladium hydrogen (PdH) reference electrode. An electrolytic eluent generator optimized for operation at capillary flow rates is also included in the system. The system requires only very small injection volumes (0.4 μl). Dionex ICS-4000 Capillary HPIC and Dionex ICS-5000 + HPIC systems.

Electrochemical Detection and Dionex CarboPac Columns Dionex ICS-5000 + and Dionex ICS-4000 Electrochemical Detector (ED) The electrochemical detector cells have been redesigned to be flow and volume optimized for capillary, microbore and standard bore formats. The optional palladium hydrogen reference electrode is robust and calibration-free. Gold working electrodes for carbohydrate analysis are available in both conventional and disposable formats. Conventional working electrodes will last for extended periods of time. However, these electrodes require periodic polishing to refinish the surface and have longer equilibration times when newly installed in a system. Disposable electrodes provide efficient, sensitive, reproducible analyses, electrode-to-electrode and lot-to-lot. After installation, rapid system re-equilibration (less than 30 min) supports quick system start-up. Dionex CarboPac Columns - Innovative Column Technology The Dionex CarboPac family of columns offers a selection of columns, each optimized for a different class of compounds. They enable high resolution separations of closely related glycoprotein oligosaccharides, monosaccharides, and sialic acids, and a wide variety of other carbohydates. The Dionex CarboPac columns use pellicular resin technology for improved chromatographic resolution, peak shape, and efficiency. The Thermo Scientific Dionex MicroBead latex particle is optimized to further improve column performance by imparting a unique chromatographic selectivity. This selectivity results in a significantly improved resolution between previously problematic analytes. Highly Crosslinked Core Latex MicroBeads with Anion-Exchange Functionalities Electrochemical detector cell for applications on standard bore and microbore size columns. Dionex MicroBead particle.

www.thermoscientific.com 04 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, Sunnyvale, CA USA is ISO 900:008 Certified. Africa +43 333 50 34 0 Australia +6 3 9757 4300 Austria +43 80 8 06 Belgium +3 53 73 4 4 Brazil +55 373 540 Canada + 800 530 8447 China 800 80 58 (free call domestic) 400 650 58 Denmark +45 70 3 6 60 Europe-Other +43 333 50 34 0 Finland +358 9 39 000 France +33 60 9 48 00 Germany +49 603 408 04 India +9 674 9494 Italy +39 0 950 59 Japan +8 6 6885 3 Korea +8 340 8600 Latin America + 56 688 8700 Middle East +43 333 50 34 0 Netherlands +3 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 333 50 34 0 Singapore +65 689 90 Sweden +46 8 556 468 00 Switzerland +4 6 76 77 00 Taiwan +886 875 6655 UK/Ireland +44 44 33555 USA + 800 53 475 AI775-EN 085S