TC54. for architects & designers. Dimensions Clearances Venting

Similar documents
TCWS54 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

TC30 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

TC36 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

TC42 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

TC42 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

for architects & designers

for architects & designers

for architects & designers

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

B36XTCE Gas Fireplace

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

Regency Horizon HZ30E Gas Fireplace

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

Natural Gas Service Installation and Meter Clearance Requirements

B41XTCE Gas Fireplace

Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision.

Contemporary Collection

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE


RESIDENTIAL BUILDING REQUIREMENTS

Builder's Manual for Ortal Fireplaces

GCI60 Hampton Cast Iron Pellet Insert

CHIMNEYS AND FIREPLACES

Gas meter clearances and service installation requirements

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

GENERAL MECHANICAL SYSTEM REQUIREMENTS

PORTRAIT WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 569 Ledge Front

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

CHIMNEYS AND FIREPLACES

DIRECT-TEMP METALBESTOS DIRECT VENT SYSTEM

Installation Manual Installation and Appliance Setup

Installation Manual Installation and Appliance Setup

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

Architect & Builder s Guide. ORTAL Heating Systems Ltd.

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

County of Yolo Development Services Building Inspection Division

Basement Renovation Guide For Residential Dwellings

APPLICATION FOR FINISHED BASEMENT PERMIT

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

GENERAL MECHANICAL SYSTEM REQUIREMENTS

2003 International Residential Building Code

General Requirements for Mobile Homes

Typical Finished Basement Details

Pulaski County, Virginia

City of Santa Monica Building and Safety Division

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

One and Two Family Additions

Installation Manual Installation and Appliance Setup

NEWS LETTER MARCH 27, 2009

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

ENBRIDGE GAS DISTRIBUTION METER BOX. Builder Installation Requirements February 2018

Administrative Changes

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

City of Oviedo Residential Permit Application Guidelines

Residential Building Plans

FRAMING INSPECTION GENERAL

New Jersey Home Inspection - Standards of Practice

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

PADMOUNT EQUIPMENT LOCATIONS / CLEARANCES

GARAGE MAIN FLOOR PLAN

THE FLORIDA BUILDING CODE

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Fairfax County, Virginia

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

General Residential Code Requirements

General Residential Code Requirements

Values That Matter PLAN CERTIFICATION WORKSHEET

RESIDENTIAL REMODELING AND BASEMENT FINISH

Siding and Soffit Installation Guidelines

Residential Accessory Structures & Room Additions

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

2018 IRC Sections R303 through R310 Building Planning II

DEVICES AND LUMINAIRES

TECHNICAL DATA COIN QUICK RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION)

Table Air Barrier and Insulation Inspection Component Criteria

Permit Posting and Inspection Procedures

UCC Permit Application Procedures

Village of Glen Ellyn Basement Remodeling Project Guidelines

Interior FRT Wood. References of Previous Model Building Codes

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

City of New Hope Community Development 4401 Xylon Ave N New Hope MN Phone: Fax: newhopemn.gov

STANDARD CONSTRUCTION PACKAGE Addendum A REV SITE & EXCAVATION Layout of the foundation and septic system as approved by local and state author

City of Aurora, Ohio. Architectural Board of Review. Residential Guidelines

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Transcription:

for architects & designers TC54 Series D Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction Manual supplied with the fireplace for detailed information regarding installation and operation. Product installation manuals can also be viewed at: www.townandcountryfireplaces.com 5056.9054-A TC54.D 040717-12

Fireplace Dimensions 62 3/8" 35 5/8" 63 7/8" 33 1/8" 44 1/2" 48 1/8" 54 5/16" 33 1/8" Must allow for minimum 1/2 inch gap for non-combustible board and facing TC54D Cad Drawing Available at www.townandcountryfireplaces.com See Minimum Combustible Framing Dimensions section on page 6 for precise framing dimensions. Examples of Common Locations 040717-12 2

Direct ent Roof Installation NOTE: A vertically vented TC54 cannot be power-vented. 48' MAX. ertical termination cap dimensions 16 1/2 40' 9 Minimum total vent height for propane: 20 feet. 20' Termination cap shown without vertical vent pipe. For vent terminal minimum clearances, see Roof Pitch Table and ent Terminal Minimum Clearances Table - both on page 8. Minimum total vent height for natural gas: 10 feet. 10' 4' MAX. Minimum 5 of vertical vent required before 1st elbow. 5' 3 040717-12

Wall Termination enting This unit can be vented horizontally (wall termination) ONLY with an approved High Capacity Power ent Kit (TCT.PAX2) using TC 8x11 ent Pipe. Finished exterior wall 29 5/8 16 3/4 Power vent terminal Blower outlets 19 1/8 Power vent dimensions Power vent terminal Up to 66 feet of run plus six 90º elbows Power vent terminal Up to 3 feet below unit Maximum vent length is 66 ft plus six 90 degree elbow or combination of other elbows equaling 90 degrees. Minimum vent length is 10 ft plus one 90 degree elbow. The vent can be installed with any combination of rise and run between the above figures including 3ft below the unit. Ensure vent pipe is properly supported. The premium Power ent fan runs quietly outside, at the exterior terminal. TC54D Cad Drawing Available at www.townandcountryfireplaces.com 040717-12 4

Mantel Clearance Chart COMBUSTIBLE FRAMING AND FINISH WALL ABOE STANDOFFS STEEL FRAMING NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING OR GAS PLUMBING IN THIS AREA. MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA NON-COMBUSTBLE FINISH MATERIAL A B FIREPLACE FRONT D TOP OF LINTEL BAR E C F STANDOFFS MANTEL CLEARANCE CHART * MANTEL CLEARANCE A 17 B 15 C 12 ** MANTEL DEPTH D 12 E 6 F 1 Minimum Clearances to Combustibles CEILING 24 * MANTEL ** ADJACENT WALL OR MANTEL SUPPORT Minimum Clearances: Side standoffs... 0 in. (0 mm) Back standoffs... 0 in. (0 mm) Top standoffs... 0 in. (0 mm) Bottom of appliance... 0 in. (0 mm) Adjacent side wall... 4 in. (102 mm) Ceiling to appliance... 24 in. (610 mm) 43 5/8 AN 18" DEEP, 2" THICK, NON-COMBUSTIBLE HEARTH MUST BE PLACED IN FRONT OF THE FULL WIDTH OF THE GLASS. See Page 7 4 *Mantel to appliance... See mantle clearance... chart above **Maximum Mantel extension... See mantle clearance... chart above... Mantel support... 4 in. (102 mm) ertical vent pipe... 1 3/4" in.(45 mm) Horizontal ent pipe (Top, sides and bottom)... 1 3/4" in.(45 mm) Unit may be recessed up to 4 1/2 with non-combustible masonary type material 5 040717-12

Steel Stud Framing Kit Dimensions Framing kit is supplied with Fireplace All other framing can be done with conventional lumber Non-combustible Board Detail NON-COMBUSTIBLE BOARD 63 1/2" 18 3/4 5 63 7/8" NOTE: Fireplace should be in its final location before framing. NON-COMBUSTIBLE materials must extend a minimum of 18 3/4 above and 5 to the sides of the framing edges. NON-COMBUSTIBLE board not included. Minimum Combustible Framing Dimensions 40 5/8" 81 1/8" 28 1/4" 63 1/2" 15 3/4" RANGE 31 1/8 to 32 7/8 33 1/8 81 1/8" 63 1/2" 114 11/16" FRAMING LINTEL RANGE 1/4" to 2" 1/2" 040717-12 6

Proflame 2 Control System Town and Country D Series fireplaces use the SIT Proflame 2 control system. This includes an elegant hand-held remote control transmitter with an easy to read LCD display. The fireplace also comes with a wall-mounted control switch which allows for simple ON/OFF operation, or can be linked with the hand-held remote control unit. This switch has a battery powered back-up system which allows operation during power outages. The wall-mounted switch easily connects to any customer supplied Home Automation System. Up to 40 Feet PROGRAM ON REMOTE OFF TOWN & COUNTRY L U X U R Y F I R E P L A C E S Hearth Extension Caution: A minimum 2 thick non-combustible hearth extension extending 18 in front of this fireplace must be fitted if a combustible sub floor extends in front of the fireplace. To ensure that the hearth does not interfere with the safety screen, the fireplace must be raised to ensure that the hearth extension is no more than 1 above the bottom of the fireplace. Lintel The fireplace can be raised using combustible or noncombustible materials ensuring that it is fully supported along the full width and depth of the fireplace. Hearth extension 2 thick minimum 18 wide minimum Width of glass 1 max above bottom of fireplace Recessed Installation This fireplace may be recessed up to a maximum depth of 4 1/2. This recess must be constructed from noncombustible material. Finishing material must not protrude past framing flanges under ANY circumstance. The safety screen and the window, with trim fitted, must be able to move freely. 7 040717-12

Minimum clearances to the vent terminal must be maintained as shown (See illustration to right & below). Measure clearances to the nearest edge of termination hood. (See pitch table below). NOTE: ent terminal must not be recessed Direct ent Terminal Clearance ENT TERMINAL MINIMUM CLEARANCES TO ADJACENT STRUCTURES NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE different CLEARANCES. 36" (91.5 cm) 24" (61 cm) Terminal to sloped Roof Pitch Table (minimum) ft m Flat to 6/12 1.00 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.50 0.46 Over 8/12 to 9/12 2.00 0.61 Over 9/12 to 10/12 2.50 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4.00 1.22 See Roof pitch table Direct ent Terminal Minimum Clearances D E B L F C B FIXED CLOSED OPEN- ABLE B B OPEN- ABLE A A B FIXED CLOSED J G A H G I M K A ENT TERMINAL A= *12 inches (30 cm) min. clearances above grade, veranda, porch, deck, or balcony B= *12 inches (30 cm) min. clearance to window or door that may be opened C= 12 inches (30 cm) min. clearance to permanently closed window recommended to prevent condensation on window D= 30 inches (76 cm) min. ertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the edge of the terminal E= 30 inches (76 cm) min. clearance to unventilated soffit F= 6 inches (15 cm) min. clearance to outside corner G= 6 inches (15 cm) min. clearance to inside corner AIR SUPPLY INLET H= 3 feet (90 cm) min. *Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator I= *6 feet (1.8 m) min. clearance to service regulator vent outlet J= *12 inches (30 cm) min. clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance K= *6 feet (1.8 m) min. clearance to a mechanical air supply inlet ent Terminal Minimum Clearances Table L= *7 feet (2.1 m) min. ^ Clearance above paved side-walk or a paved driveway located on public property M= **30 inches (76 cm) min clearance under veranda, porch, deck, or balcony A AREA WHERE TERMINAL IS NOT PERMITTED ^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149.1 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, NFPA54/ANSI Z223.1 GAS METER 040717-12 8 G

9 040717-12

040717-12 10

11 040717-12

2017 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For personal service pertaining to specific projects, contact: Town & Country Architect Resource Planner architects@townandcountryfireplaces.com www.townandcountryfireplaces.com Phone: (250) 748-1184 2975 Allenby Road, Duncan, BC Canada 9L 68