Great Do you need it larger or would like to relocate windows and doors or do you need something completely different?

Similar documents
GARAGE MAIN FLOOR PLAN

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

Custom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems

Incl. Ft. In. SF Qty. Calcs Item Directions

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

GARAGE MAIN FLOOR PLAN 1

GARAGE MAIN FLOOR PLAN 1

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

BARN MAIN FLOOR PLAN. #G457a 12 x 20 x 8 Gentleman Bunkhouse Shed By SDS-CAD Specialized Design Systems 12'-0" 3'-0" 4'-0" 1'-6" 3'-0" 1'-6" 20'-0"

DATE: 4/1/2014 SCALE: 3/16"=1'- 0" SHEET:

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Sample Plan Not for Construction for pricing

GARAGE MAIN FLOOR PLAN

Pulaski County, Virginia Practical Wall Bracing

GARAGE MAIN FLOOR PLAN

BOISE CASCADE - BC FRAMER 3.0 US MAIN FLOOR File Name:

R Code and Commentary for 2012 NC Residential Code final 03/06/13

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

REAR PORCH/COVER PATIO

B and H Cedar Log Homes, L.L.C. 65 Nottingham Dr.

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED

Applying for Permits to build a new house in Linn County

GARAGE MAIN FLOOR PLAN SDSCAD Specialized Design Systems

Customer A101. Front Elevation. Roof Peak 24' /32" Roof 17' - 6" Main Floor 9' - 6" Floor Joist 8' - 6" Basement 0' - 6" Grade 0' - 0"

Featuring Selection and Installation Information for Lateral Wind Loads

GYPSUM BOARD. 2x WALL FRAMING EXTERIOR SHEATHING 3/4" PT WOOD FURRING WEATHER RESISTIVE BARRIER FIBERCEMENT SIDING COR-A-VENT OR SIM PT STARTER STRIP

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Payton Place Lot 106

Meier Residence. Structural Calculations. Project Address: 330 East Lewis Park Cove, Bountiful, Utah

STRUCTURAL EDGE ENGINEERING, PLLC

GARAGE MAIN FLOOR PLAN

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

HOLDOWN & STRAP SCHEDULE

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

14' x 24' Garage Plan

Building Guide. Colorado Chapter of the International Code Council

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Framing Methods Structural Components

LVL Product Guide 2.0E LVL 1.5E LVL

Building Division Informational Handout

AG-1.0. M.E. Designs Civil & Structural Engineering Drafting & Design PATRICIA EDWARDS FAMILY TRUST SANTA BARBARA, CA TUNNEL ROAD LANE

Garage/Accessory Structures

Attic. Bedroom 8'-11 5/8" 16'-5 5/8"

Calculated Quantities and Details

BROADSPAN. LVL Design Brochure. Design properties for LVL header and beam applications in the U.S. for residential floor and roof systems

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

BWP BWP 8'-0" 5'-0" BWP 12'-0" 5'-0" 60'-0" GARAGE 19'-7" x 59'-0" GARAGE 14'-3" x 59'-0" BWP. 9' Ceiling Height 12'-0" 5'-0" BWP

SOME SAMPLE TAKEOFFS FOUNDATION

GETTING STARTED... 2 YOUR LIST OF PRODUCTS... 2 WHAT THAT LIST BECOMES... 2 PRODUCTS CREATED AS ENVISIONEER ELEMENTS... 3

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

Residential Patio Cover Specifications

E-Blueprints. Shed WorkShop Loft 20' x 20' 800 sq. feet Shed Roof 2 x Framed Walls 8' Doors 8' ceiling Height E-BLUEPRINTS C ABINS G ARAGES

STEEL FRAMING INDUSTRY ASSOCIATION OBSERVATION REPORT PROTOCOL STRUCTURAL FRAMING GUIDELINES FOR THE INSPECTOR

CRM Homes BUILDER Mangan Drafting Jim Mangan

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Detached Garages and Building Permits. 1 and 2 Family Dwellings

SITE AND BUILDING NEW CONSTRUCTION FOR: BUSH'S CHICKEN RESTAURANT EXTERIOR COOLER/FREEZER PROTOTYPE. Contact Information:

Garris Evans Estimating Department. Project Name: Project Address: Customer Phone Number: Project Type: Residential Commercial Homeowner

Christensen Detached Garage

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

front elevation right elevation

U.S. WALL GUIDE. Featuring Trus Joist TimberStrand LSL and Parallam PSL Wall Framing. Engineered to meet code requirements for walls up to 30' tall

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

KP Estimating 2700 East Hayden View Dr Couer d' Alene Idaho (503)

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Detached Residential Garage or Accessory Building ~ Includes Garage Conversion to Habitable Space ~

2003 International Residential Building Code

6.0 TUTORIAL. Cascade Consulting Associates, Inc. PO Box 1617 Corvallis, Oregon 97339

BERRIDGE SPACEFRAME BUILDING COMPONENTS DESIGN GUIDE

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

TYPICAL BEARING WALL FRAMING

Minimum Residential Plan Submittal Requirements

Typical Garage/Storage Shed/Shop Details YOU CAN USE TO BUILD YOUR GARAGE, STORAGE SHED OR SHOP BUILDING (Valid for 2007, check for annual updates)

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

Residential Project Example

Connect Easily to Insulated Concrete Forms

Administrative Changes

TOWN OF SOUTH KINGSTOWN REQUIREMENTS FOR BUILDING PERMITS RESIDENTIAL SINGLE FAMILY

Connect Easily to Insulated Concrete Forms

The Homeowner s Building Application Checklist for Constructing a Residential Addition

Main Floor Plan Scale: 1/8"=1'-0"

LPI 56 Technical Guide

One and Two Family Additions

STRUCTURAL ENGINEERING CALCULATIONS NEW WINDOW OPENING IN EXISTING PERIMETER LOAD BEARING WOOD FRAMED WALL Project Address: Job #: 80167

PLANNING DEPARTMENT. Introduction

Proud of its Heritage, Preparing for its Future

Project Name: the candlelight. Project No. Scale: sewer line. water line 1 8"=1'-0"

Considerations for Outof-Plane. Design

Table of Contents. Page Title

A.ALL CONCRETE SHALL BE NORMAL WEIGHT (150 PCF) CONCRETE: f'c=3,000 PSI AT 28 DAYS.

Transcription:

Congratulations: You should have our free 384 SF cabin plan with loft and are one step closer to enjoying the vacation space that will result from using these plans. We hope that these plans are the correct size and configuration for your property. Great Do you need it larger or would like to relocate windows and doors or do you need something completely different? No Problem We can create a custom plan that matches your specifications in a short time and for a reasonable cost. We also have many other pre-designed plans that are displayed on our website. http://www.cabinplans123.com/ We have many more plans that are not shown on the website. There is a good chance we have one close to your proposed building. You should be able to see the quality and completeness of our plans. Our purchased plans are equal to these with the exception of being on full size drawing paper. We have reduced this free plan to personal printer size so that you can print them your self. Your Next step Call Cad Northwest (503) 6330 to order an inexpensive pre-designed plan, a custom plan, to receive a quote, or ask a question. If you find this free garage plan useful then please like or share our site on Facebook or Google+. Go to our Facebook Page Go to our Google+ Page Cad Northwest Custom Home Design 22685 SW Conifer Dr. Sherwood OR 97140 www.cabinplans123.com cadnw@zzz.com (503) 6330

Page Title Index 1 Congratulations 2 Index 3 Front and Rear Elevation 4 Right and Left Elevation 5 Main Floor Plan 6 Foundation Plan 7 Roof Plan 8 Cross Section 9 Typical Wall Detail 10 Alternate Foundation Detail (Slab Option) 11 Alternate Brace Panel 12 Notes 13 Notes 14 Floor Joist Calculation 15 Rafter Calculation 16 Porch Roof Beam Calculation 17 Porch Deck Beam Calculation 18 Floor Beam Calculation 19 Materials List

C0384A Cabin Plan B01 Selection Conditions Data Attributes Actual Critical Status Ratio Values Adjustments BeamChek v2005 licensed to: Cad Northwest Reg # 5234-65453 2x 6 DF-L #2 @ 16 in. oc Repetitive Use, NDS 2001 Min Bearing Area R1= 0.5 in² Beam Span Beam Wt per ft Bm Wt Included Max Moment TL Max Defl LL Max Defl Section (in³) 7.56 6.02 80% Base Values Base Adjusted CF Size Factor Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use Cl Stability 00 R2= 0.5 in² Lu = 0.0 Ft 9.0 ft Reaction 1 LL 240 # 0 # Reaction 1 TL 300 # 0 # Maximum V 300 # 675 '# Max V (Reduced) 269 # L / 240 TL Actual Defl L / 366 L / 360 LL Actual Defl L / 457 Shear (in²) 8.25 2.25 27% Fb (psi) 900 1346 1.300 1.15 Floor Joist TL Defl (in) 0.30 0.45 66% Fv (psi) DL Defl LL Defl 0.24 0.30 79% 0.06 in E (psi x mil) Date: 1/04/07 Reaction 2 LL Reaction 2 TL Fc l (psi) N/A Rb = 0.00 Le = 0.00 Ft Kbe = 0.0 240 # 300 # Loads Uniform LL: 53 Uniform TL: 67 = A Uniform Load A R1 = 300 SPAN = 9 FT Uniform and partial uniform loads are lbs per lineal ft. R2 = 300

C0384A Cabin Plan B02 Selection Conditions Data Attributes Actual Critical Status Ratio Values Adjustments BeamChek v2005 licensed to: Cad Northwest Reg # 5234-65453 2x 12 DF-L #2 @ 16 in. oc Lu = 0.0 Ft Repetitive Use, DL adj: 12:12 pitch, NDS 2001 Min Bearing Area R1= 1.1 in² R2= 1.1 in² DL Defl<0.01 in. Beam Span Beam Wt per ft Bm Wt Included Max Moment TL Max Defl LL Max Defl Section (in³) 34 17.86 56% Base Values Base Adjusted CF Size Factor Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use Cl Stability 9.0 ft Reaction 1 LL 600 # 0 # Reaction 1 TL 685 # 0 # Maximum V 685 # 1541 '# Max V (Reduced) 542 # L / 240 TL Actual Defl L / >1000 L / 360 LL Actual Defl L / >1000 Shear (in²) 16.88 4.52 27% Fb (psi) 900 1035 0 1.15 00 Rafters TL Defl (in) 0.08 0.45 18% Fv (psi) LL Defl 0.07 0.30 23% E (psi x mil) Date: 1/04/07 Reaction 2 LL Reaction 2 TL Fc l (psi) N/A Rb = 0.00 Le = 0.00 Ft Kbe = 0.0 600 # 685 # Loads Uniform LL: 133 Uniform TL: 152 = A Uniform Load A R1 = 685 SPAN = 9 FT Uniform and partial uniform loads are lbs per lineal ft. R2 = 685

C0384A Cabin Plan B04 Selection Conditions Data Attributes Actual Critical Status Ratio Values Adjustments BeamChek v2005 licensed to: Cad Northwest Reg # 5234-65453 4x 8 DF-L #2 NDS 2001 Min Bearing Area Beam Span Beam Wt per ft Bm Wt Included Max Moment TL Max Defl LL Max Defl Section (in³) 30.66 22.44 73% Base Values Base Adjusted CF Size Factor Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use Cl Stability R1= 2.3 in² 00 R2= 2.3 in² Lu = 0.0 Ft 6.0 ft Reaction 1 LL 1200 # 6.17 # Reaction 1 TL 1458 # 37 # Maximum V 1458 # 2188 '# Max V (Reduced) 1165 # L / 240 TL Actual Defl L / 905 L / 360 LL Actual Defl L / >1000 Shear (in²) 25.38 9.71 38% Fb (psi) 900 1170 1.300 Porch Beam TL Defl (in) 0.08 0.30 27% Fv (psi) DL Defl LL Defl 0.07 0.20 33% 0.01 in E (psi x mil) Date: 1/04/07 Reaction 2 LL Reaction 2 TL Fc l (psi) N/A Rb = 0.00 Le = 0.00 Ft Kbe = 0.0 1200 # 1458 # Loads Uniform LL: 400 Uniform TL: 480 = A Uniform Load A R1 = 1458 SPAN = 6 FT Uniform and partial uniform loads are lbs per lineal ft. R2 = 1458

C0384A Cabin Plan B05 Selection Conditions Data Attributes Actual Critical Status Ratio Values Adjustments BeamChek v2005 licensed to: Cad Northwest Reg # 5234-65453 4x 8 DF-L #2 NDS 2001 Min Bearing Area Beam Span Beam Wt per ft Bm Wt Included Max Moment TL Max Defl LL Max Defl Section (in³) 30.66 17.74 58% Base Values Base Adjusted CF Size Factor Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use Cl Stability R1= 1.4 in² 00 R2= 1.4 in² Lu = 0.0 Ft 8.0 ft Reaction 1 LL 720 # 6.17 # Reaction 1 TL 865 # 49 # Maximum V 865 # 1729 '# Max V (Reduced) 734 # L / 240 TL Actual Defl L / 858 L / 360 LL Actual Defl L / >1000 Shear (in²) 25.38 6.12 24% Fb (psi) 900 1170 1.300 Deck Beam TL Defl (in) 0.11 0.40 28% Fv (psi) DL Defl LL Defl 0.09 0.27 35% 0.02 in E (psi x mil) Date: 1/04/07 Reaction 2 LL Reaction 2 TL Fc l (psi) N/A Rb = 0.00 Le = 0.00 Ft Kbe = 0.0 720 # 865 # Loads Uniform LL: Uniform TL: 210 = A Uniform Load A R1 = 865 SPAN = 8 FT Uniform and partial uniform loads are lbs per lineal ft. R2 = 865

C0384A Cabin Plan B06 Selection Conditions Data Attributes Actual Critical Status Ratio Values Adjustments BeamChek v2005 licensed to: Cad Northwest Reg # 5234-65453 4x 8 DF-L #2 NDS 2001 Min Bearing Area Beam Span Beam Wt per ft Bm Wt Included Max Moment TL Max Defl LL Max Defl Section (in³) 30.66 21.05 69% Base Values Base Adjusted CF Size Factor Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use Cl Stability R1= 2.2 in² 00 R2= 2.2 in² Lu = 0.0 Ft 6.0 ft Reaction 1 LL 1080 # 6.17 # Reaction 1 TL 1368 # 37 # Maximum V 1368 # 2053 '# Max V (Reduced) 1093 # L / 240 TL Actual Defl L / 964 L / 360 LL Actual Defl L / >1000 Shear (in²) 25.38 9.11 36% Fb (psi) 900 1170 1.300 Floor Beams TL Defl (in) 0.07 0.30 25% Fv (psi) DL Defl LL Defl 0.06 0.20 29% 0.02 in E (psi x mil) Date: 1/04/07 Reaction 2 LL Reaction 2 TL Fc l (psi) N/A Rb = 0.00 Le = 0.00 Ft Kbe = 0.0 1080 # 1368 # Loads Uniform LL: 360 Uniform TL: 450 = A Uniform Load A R1 = 1368 SPAN = 6 FT Uniform and partial uniform loads are lbs per lineal ft. R2 = 1368

MATERIAL LIST C0384A Cabin Plan Standard Foundation W/ Framed Roof This estimate is designed solely to provide the customer with a rough estimate of the amount of material used in the given project. The material estimate is based on normal and typical building and construction techniques. The actual amount of material used may vary from this estimate due to a number of factors. Consequently, no representation or warranty has been made that the amount of material used will not vary from the estimate. ITEM CALC SIZE LENGTH O.C. QTY 1 MAIN EXT STUDS 2X6 92-5/8" 16'' 57 EA 2 MAIN TREATED SILL 2X6 77 LF 3 MAIN INT PLATES 2X4 60 LF 4 MAIN EXT PLATES 2X6 160 LF 5 MAIN INT STUDS 2X4 16'' 24 EA 6 MAIN FLOOR PLYWOOD 3/4'' 384 SF 7 UPPER INT WALL STUDS 2x4 VARIES 16'' 37 EA 8 UPPER CEILING S.R. 1/2" GYP. 543 SF 9 HEADER, (Main Window) N/A 4X12 6' 1 EA 10 HEADER, (Ext Main Door) N/A 4X8 4' 1 EA 11 HEADER, (Main Window) N/A 4X8 4' 1 EA 12 HEADER, (Main Window) N/A 4X8 5' 1 EA 13 RAFTERS B02 2x12 15' 16'' 38 EA 14 EAVE BLOCKING 2X 14.5'' 16'' 36 EA 15 H2.5 RAFTER TIE 16'' 38 EA 16 ROOF SHEATH 1/2'' CDX 815 SF 17 ROOF FELT 30# Felt 815 SF 18 ROOFING 662 SF 19 BARGE RAFTERS 2X6 15' 4 EA 20 MAIN EXT WALL S.R. 1/2" GYP. 616 SF 21 MAIN INT WALL S.R. 1/2" GYP. 480 SF 22 MAIN CEILING S.R. 1/2" GYP. 384 SF 23 EXT WALL SHEATH 1/2" CDX 616 SF 24 EXT WALL VAPOR 15# Felt 616 SF 25 EXT SIDING (See Plan) Varies 616 SF 26 CONCRETE 4.24 CY 27 UPPER JOISTS B01 2X6 16' 16'' 9 EA 28 UPPER FLOOR PLYWOOD 5/8'' 140 SF 29 POST 4X6 8' 4 EA 30 MAIN FLOOR JOISTS B02 2X6 16' 18 EA 31 POST 4X4 6' 2 EA 32 DECK BEAM B05 4X8 9' 2 EA 33 FLOOR BEAM 4X8 24' 1 EA 34 PORCH BEAM B04 4X8 P.T. 6' 2 EA 35 DECK JOISTS 2X6 P.T. 6' 14 EA 36 DECKING 2X6 P.T. 18' 13 EA 37 MAIN FLOOR RIM JOISTS 2X6 80' 80 LF 38 RIDGE BEAM 2X14 30' 1 EA 39 ANCHOR BOLTS 1/2'' 48'' 20 EA 40 ANCHOR BOLTS 5/8'' 3 EA 41 HOLD DOWNS HD5A W/ SSTB20 2 EA 42 HOLD DOWNS HD2A 2 EA 43 STRAPS LSTA18 10 EA 44 FLOOR PLYWOOD 1-1/8 384 SF