SOUND INSULATION TESTING IN DWELLINGS

Similar documents
Robin Mackenzie Partnership Design of Separating Constructions that are Resistant to the Transmission of Noise PART 1 of 2

June Non - Residential New Build Partition walls

June Non - Residential Refurbishment Separating floors

Acoustic Performance of Light Steel Framed Systems

1.0 INTRODUCTION BUILDING REGULATIONS SOUND INSULATION REQUIREMENTS TEST PROCEDURE AND ANALYSIS...3

June Residential Refurbishment Separating floors

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

URSA ACOUSTIC ROLL URSA GLASSWOOL.

April Section 4.3. Separating Floors

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Part E robustdetails. robustdetails. January 2018 Update Pack

GypWall QUIET Acoustic separating wall system

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

Introduction. Contents

June Residential Refurbishment Separating walls

How glass or rock mineral wool works in a wall or floor cavity

Approved Document E Technical Design Report

Independent twin frame high performance acoustic separating wall system

THE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

December 2005 Cl/SfB Ff4. Acoustic Compliance

URSA MINERAL WOOL URSA Acoustic Roll

Specialists in Acoustic Flooring and House to Flat Conversions

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

URSA Acoustic Roll Acoustic Insulation for Floors and Walls

GypWall QUIET Acoustic separating wall system

ROCKWOOL FLEXI Insulation Application Guide

April Section Internal Walls

GypLyner IWL Independent wall lining system

Selecting floors and ceilings

Part E robustdetails. robustdetails. January 2019 Update Pack. Dear Colleague,

GypWall AUDIO The ultimate cinema wall system

Guidance on U Values from Domestic Heating Design Guide

Curved partition and wall lining system

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

domestic noise introduction Introduction Background Aims Latest changes Relevant legislation 5.0.

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

The SoundBar System HIGH PERFORMANCE ACOUSTIC FLOORING SOLUTION

INTERTENANCY SYSTEMS 2018

Staggered stud acoustic partition system

Building Regulations 1997

RW SEMI-RIGID AND RIGID SLABS (RWA45, RW3, RW4, RW5 & RW6)

GypWall AUDIO The ultimate sound insulating wall system

Suspended timber upper floors

CI/SfB l l l Ym1 l (M2) l July Superior 4 in 1 insulation TIMBER FRAME SOLUTIONS GUIDE

SOUND INSULATION DESIGN OF MODULAR CONSTRUCTION HOUSING

SubPrimo. subprimo. Acoustic insulation for timber & laminate flooring. Uniclass L5395:N372 EPIC E485:Y45. CI/SfB (43) T (P2)

SOUND INSULATION ASSESSMENT RANELAGH MULTI-DENOMINATIONAL SCHOOL, DUBLIN October 2014

ACOUSTIC SYSTEMS PROFLOOR. effective solutions for impact and airborne noise INNOVATION BUILT ON EXPERIENCE

MEASUREMENT OF THE IMPACT SOUND INSULATION OF WALLS

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for

Terraced Masonry Test Houses in Bradford

The extra strong, extra durable, sound resistant system that you can direct fix to

SOUND INSULATION TESTING SITE READINESS CHECKLIST

Single frame acoustic separating wall system

Relationship between flanking noise through a common ceiling plenum and plenum absorption George van Hout, John Pearse and Brian Donohue

LOXO CLADDING SOUND INSULATION PERFORMANCE. Opinion on Acoustic Performance of. Loxo Cladding Systems Utilising Aerated Concrete.

Specialist products. Proven expertise. Acoustic flooring systems to meet the 2010 Scottish Standards - Section 5

C06. S05. P02 P12 GypFloor silent

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

CasoLine MF Concealed grid MF suspended ceiling system

C06. S05. P02 P12 GypFloor silent

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Loadbearing timber joist floors

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

Part E robustdetails. robustdetails. June 2018 Update Pack. Dear Colleague,

The ultimate sound insulating wall system

SEPARATING WALLS CLASS 1A

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

Knauf Wall Liner. Head Track. Brackets. Wall Lining Stud. Fixings. Knauf Plasterboard. Floor Track. 98 Wall Liner

FLANKING TRANSMISSION IN STEEL-CONCRETE COMPOSITE FLOORS

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

CI/SfB. November Design Guide Concrete block masonry

Acoustic Cradle Levelling System

Assessing external noise impacts for apartments

Ozone Panel 120 Acoustic Assessment and Optimization

Intertenancy Barrier Systems for Terrace Homes

SCHEDULE OF BUILDING OPERATIONS

Fire resistance and acoustic properties

GypWall RAPID db Plus

Single frame acoustic separating wall system

September Reflex Bearers

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

CasoLine MF Concealed grid MF suspended ceiling system

Technical Supplement. Internal Fire and Acoustic Rated Floor Solution INTERIORS

B Page 1 of 21-

Dwelling-houses and flats performance standards for separating walls, separating floors and stairs that have a separating function.

A Handbook of thermal bridging details incorporating aircrete blocks

GIB Quiet Clip GIB CBI March Features and Benefits

Experimental investigations on acoustical retrofitting of timber floors

PREDICTING SOUND INSULATION PERFORMANCE

GypLyner (walls) Metal framed wall lining system. GypLyner.

CASE STUDY OF THE SOUND REDUCTION OF VARIOUS RESIDENTIAL GLAZING TREATMENTS

Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:

Status: Rev: Comments Date: Author: Reviewer:

Transcription:

SOUND INSULATION TESTING IN DWELLINGS Chris Dilworth, AWN Consulting

This Presentation Discusses the standards by which we judge sound insulation performance. Presents the results of sound insulation tests performed over the last three years. Comments on the sound insulation performance and particular characteristics of a variety of constructions. Offers guidance in relation to appropriate remedial measures.

Building Regulations Requirements From Part E of the Second Schedule to the Building Regulations (1997): A wall which separates a dwelling from another dwelling shall have reasonable resistance to airborne sound. A floor which separates a dwelling from another dwelling shall have reasonable resistance to airborne sound. A floor above a dwelling which separates it from another dwelling shall have reasonable resistance to impact sound. Note that there is no absolute numerical requirement.

Technical Guidance Document Part E - Sound In the absence of an absolute numerical requirement in the Regulations themselves, sound insulation is typically assessed through reference to Part E Section 4 Similar Construction. This Section describes methods by which a wall or floor, identical or similar to an existing construction, may satisfy the requirements in respect of airborne or impact sound resistance.

Similar Construction Test Method The results of sound insulation tests on an existing construction are compared with guideline values as follows: Type of performance Individual values Test in at least four pairs of rooms Mean values Test in at least eight pairs of rooms Airborne sound (minimum values)* 49 (walls) 53 (walls) 52 (walls) 48 (floors) 52 (floors) 51 (floors) Impact sound (maximum values)** 65 61 62 Notes: * Airborne sound Weighted Standardized Level Difference (D nt,w ) ** Impact sound Weighted Standardized Sound Pressure Level (L nt,w )

Limits on the use of test evidence This method contains an important caveat. The values are provided to enable an existing construction to be assessed before similar new construction is undertaken. A failure of new construction to achieve the values is not in itself evidence of a failure to comply with the requirements of the Regulations. In other words, even if a construction fails to achieve the guideline values, it could be argued that it offers reasonable resistance to airborne or impact sound.

Sound Insulation Testing in Ireland Average results from 359 airborne and impact sound insulation tests. AIRBORNE SOUND INSULATION OF PARTY WALLS Plasterboard on dabs on dense concrete block Plasterboard on metal channel on dense concrete block Dense concrete block with thick render or plaster coat Cavity blockwork (100/50/100) Plasterboard on steel frame Plasterboard on timber frame 52.7dB D nt,w 53.9dB D nt,w 55.1dB D nt,w 58.5dB D nt,w 61.5dB D nt,w 61.7dB D nt,w

Sound Insulation Testing in Ireland AIRBORNE SOUND INSULATION OF PARTY FLOORS Timber floor (i.e. floor type 3 as per Document E) Concrete floor (i.e. floor type 1 or 2 as per Document E) 53.5dB D nt,w 57.4dB D nt,w IMPACT SOUND INSULATION OF PARTY FLOORS Timber floor without resilient/floating layer Timber floor with resilient/floating layer Concrete floor with soft covering or floating layer 67.9dB L nt,w 45.5dB L nt,w 43.0dB L nt,w

Plasterboard on Dabs 1 no. layer of 12.5mm/15mm plasterboard 215mm dense concrete block Plaster dabs Typical arrangement of plasterboard on dabs

Plasterboard on Dabs Average airborne sound insulation performance 52.7dB D nt,w 46% of the constructions tested gave results <53dB D nt,w 32% of the constructions tested gave results <52dB D nt,w 6% of the constructions tested gave results <49dB D nt,w The vast majority of the examples tested exhibited a pronounced dip in sound insulation performance in the mid to high frequency region. The measured values ranged from 46 to 58dB D nt,w. Fitted wardrobes can have a significant effect; the mean value in this instance is 57dB D nt,w.

Plasterboard on Dabs 70 Frequency f Hz 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 DnT 1/3 Octave db 29.9 31.1 37.0 32.5 36.7 36.3 40.0 44.8 49.4 54.8 56.9 58.3 62.4 62.1 60.3 58.0 52.8 50.4 Standardized Level Difference DnT, db 60 50 40 30 20 51.7 52.7 10 53.7 63 125 250 500 1000 2000 4000 Frequency f, Hz Typical sound insulation spectrum Single figure index: 53dB D nt,w

Plasterboard on Dabs In subjective terms, noise transfer across these constructions is often poor, even when the overall performance is equal to or greater than 52dB D nt,w. This is a function of the dip. Conversation, televisions, alarm clocks etc. can be clearly audible. In the very worst instances, e.g. when conversation is not only audible but intelligible, it is clear that the construction fails to offer reasonable resistance to airborne sound even though the measured results achieve the guideline values as set down in the Similar Construction test method.

Alternative Plasterboard Fixing Methods One alternative fixing method we have tested recently employs a metal U channel which is restrained to the wall using metal straps. Plasterboard is attached to the U channel and the metal strap is adjustable to give cavity depths of 30mm to 100mm. Sound insulation performance in excess of 60dB D nt,w has been measured with this system.

Alternative Plasterboard Fixing Methods Metal Straps Metal U Channel

Alternative Plasterboard Fixing Methods 1 no. layer of 12.5mm/15mm plasterboard 30-100mm cavity 215mm dense concrete block Metal Straps Metal U Channel

Compare with Plasterboard on Dabs Frequency f Hz 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 DnT 1/3 Octave db 23.0 22.2 30.5 33.3 36.8 44.6 49.4 50.9 53.4 58.5 62.6 64.1 64.8 64.7 67.5 67.9 67.7 69.1 Standardized Level Difference DnT, db 70 60 50 40 30 20 70.7 72.0 10 75.0 63 125 250 500 1000 2000 4000 Frequency f, Hz Plasterboard on 80mm cavity (61dB D nt,w ) Plasterboard on dabs (53dB D nt,w ) Typical sound insulation spectrum

Alternative Plasterboard Fixing Methods Installing plasterboard using alternative fixing methods can offer significant improvements. When compared to plasterboard on dabs, it reduces/eliminates the mid to high frequency dip. The results presented here represent the upper end of what is achievable. We have also observed a reduction in the mid to high frequency dip when standard metal top-hat sections are used to attach the plasterboard. This type of construction also provides good good structureborne isolation, i.e. clicking light switches and sockets. The low-frequency performance of the wall can be reduced.

Alternative Plasterboard Fixing Methods Summary: Attaching plasterboard to concrete block walls using dabs, typically results in a dip in sound insulation at mid to high frequencies. Attaching plasterboard to concrete block walls using metal channels offers better overall performance but can result in a dip in sound insulation at low-frequencies (this effect can minimised by large cavity depths). Using a traditional render finish does not result in either of the two negative effects noted above.

Dense Concrete Block with 12 to 18mm Rendered Finish 215mm dense concrete block 12 to 18mm rendered finish, e.g. plaster or sand/cement Typical arrangement of rendered concrete block

Dense Concrete Block (Rendered) Average airborne sound insulation performance 55.1dB D nt,w 2.1% of the constructions tested gave results <53dB D nt,w 1.8% of the constructions tested gave results <52dB D nt,w 1.1% of the constructions tested gave results <49dB D nt,w (the cause was flanking noise transfer in every instance) A typical sound insulation spectrum exhibits an upward trend from low to high frequency, with nothing significant by way of dips. The measured values ranged from 51 to 62dB D nt,w (excluding results significantly affected by flanking transmission).

Dense Concrete Block (Rendered) 70 Frequency f Hz 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 DnT 1/3 Octave db 32.2 34.0 37.5 42.7 41.6 42.2 45.0 46.3 50.1 51.9 53.1 57.5 57.7 59.8 61.6 61.6 59.3 57.8 Standardized Level Difference DnT, db 60 50 40 30 20 60.1 60.8 10 58.7 63 125 250 500 1000 2000 4000 Frequency f, Hz Typical sound insulation spectrum Single figure index: 57dB D nt,w

Dense Concrete Block (Rendered) Performance is consistent and less prone to shortfalls as a result of poor workmanship. In subjective terms, noise transfer is rarely perceived to be excessive. The construction comprises only a single leaf. When there are plug sockets or light switches in the party wall, there is potential for associated noise to be clearly audible on the other side of the wall.

Timber Frame 19mm plasterboard plank and 12.5mm wallboard Timber stud Mineral wool quilt Typical arrangement of timber frame

Timber Frame Average airborne sound insulation performance 61.7dB D nt,w None of the constructions tested gave results <53dB D nt,w A typical sound insulation spectrum exhibits an upward trend from low to high frequency, with nothing significant by way of dips. The measured values ranged from 56 to 69dB D nt,w.

Timber Frame 70 Frequency f Hz 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 DnT 1/3 Octave db 18.8 21.6 33.8 36.3 35.2 40.6 41.7 46.5 49.8 53.2 54.8 58.6 59.9 62.7 64.1 68.2 68.9 69.0 Standardized Level Difference DnT, db 60 50 40 30 20 68.0 67.0 10 65.4 63 125 250 500 1000 2000 4000 Frequency f, Hz Typical sound insulation spectrum Single figure index: 57dB D nt,w

Timber Frame Performance is consistent and is not prone to shortfalls as a result of poor workmanship. In subjective terms, noise transfer is rarely perceived to be excessive. The construction comprises two leaves of plasterboard on timber studs that are nominally independent of one another. Hence there is little transfer of noise from the use of plug sockets or light switches in the party wall. However, careful consideration must be given to the potential for airborne noise transfer via such fittings.

Timber Frame Where possible, electrical sockets should not be located on party walls. If this is unavoidable, they should be offset such that they are not back-to-back and should be boxed-in at the rear with plasterboard. Water and waste pipes should not be located within the party wall cavity; these should be located within the demise of the dwelling they serve (i.e. using suitable risers).

Lightweight Block 1 no. layer of 12.5mm/15mm plasterboard 215mm lightweight aerated concrete block Metal channels or plaster dabs Typical arrangement of lightweight aerated concrete block

Lightweight Block We have seen a reduction in the use of lightweight aerated concrete block in party walls over the last 2 years. Standard party wall construction is 1 layer plasterboard each side of the lightweight block fixed using either metal channels or dabs. Measured sound insulation for this construction is typically in the range 48 to 50dB D nt,w.

Lightweight Block with 1 Layer Plasterboard 80 Source room volume: 30 m³ Receiving room volume: 30.00 m³ Frequency f Hz 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 DnT 1/3 Octave db 31.6 27.5 35.5 26.5 31.5 30.4 34.2 36.9 43.2 48.5 53.5 59.0 62.8 65.8 69.3 71.6 70.4 66.4 Standardized Level Difference DnT, db 70 60 50 40 30 20 Frequency range according to the curve of reference values (ISO 717-1) 66.4 67.8 10 71.2 63 125 250 500 1000 2000 4000 Frequency f, Hz Single figure index: 50dB D nt,w

Improving the Sound Insulation Performance of Lightweight Block The density of lightweight concrete block is ~650kg/m 3. This density of standard concrete block is ~1850kg/m 3. This is one of the factors for the relatively poor mid to low frequency performance apparent in the sound insulation performance of lightweight block. Upgrading the construction by installing 2 layers of plasterboard can result in significant increases in the measured sound insulation performance. Tests have indicated that increases of up to 7dB are possible.

Lightweight Block 2 no. layers of 12.5mm/15mm plasterboard 215mm lightweight aerated concrete block Metal channels or plaster dabs Typical arrangement of lightweight aerated concrete block with enhanced lining

Compare 1 and 2 Layers Plasterboard Source room volume: 30 m³ Receiving room volume: 30.00 m³ Frequency f Hz 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 DnT 1/3 Octave db 30.7 34.9 32.4 41.0 35.9 39.5 42.8 44.2 48.3 53.6 60.5 67.0 70.0 68.1 70.0 73.4 72.2 73.7 Standardized Level Difference DnT, db 80 70 60 50 40 30 20 Frequency range according to the curve of reference values (ISO 717-1) 76.3 76.5 10 74.0 63 125 250 500 1000 2000 4000 Frequency f, Hz Typical sound insulation spectrum 2 layers plasterboard (57dB D nt,w ) 1 layer plasterboard (50dB D nt,w )

Remedial Measures in Occupied Dwellings The alternative wall constructions discussed so far require works to be undertaken on both sides of the party wall. This invariably results in significant nuisance for dwelling occupants on both sides of the party wall. It also increases the costs (i.e. plasterer, painter, carpenter, and electrician required to work on both sides of the wall). It is possible to carry out works to only one side of the wall and still achieve improvements in the sound insulation performance of up to 10dB.

Remedial Measures in Occupied Dwellings Suitable wall linings to be applied to one side of the wall must offer both mass and isolation. Mass is provided by using two layers of 15mm plasterboard. Isolation is provided by installing the plasterboard on an independent stud system or proprietary isolating battens.

Remedial Measures in Occupied Dwellings 2 no. layers of 15mm plasterboard, all joints staggered and taped 100mm 50mm mineral wool quilt (>12kg/m 3 ) 70I70 metal studs, fitted between head and base tracks Blockwork wall 1 no. layer of plasterboard Independent wall lining

Remedial Measures in Occupied Dwellings Proprietary isolating battens

Junction Details The sealing of junctions between party walls and the surrounding structural elements can have a significant effect on the measured sound insulation performance. The most common acoustic weakness witnessed during testing is at the junction between the party wall and the underside of the floor/ceiling structure above. Some party walls are also affected by leakage at the base of the wall.

Noise Transfer Through Ceiling Cavity Floor screed Pre-cast concrete floor slab Plasterboard ceiling on battens Plasterboard wall lining not sealed to the underside of the floor slab Typical section through party wall and floor/ceiling junction

Noise Transfer Through Ceiling Cavity Noise transfer thru ceiling cavity Mortar joint between party wall and concrete slab is prone to cracking Typical section through party wall and floor/ceiling junction

Noise Transfer Through Ceiling Cavity The degree of noise transfer through the ceiling cavity varies significantly. In some cases, this transfer path is insignificant. In other cases, the reduction in the measured D nt,w sound insulation could be as high as 3 to 5dB. Therefore, a wall with an on-site measured sound insulation rating of 53dB may be capable of 56 to 58dB if this noise transfer path is treated.

Noise Transfer Through Ceiling Cavity Treatments: The plasterboard wall layers should extend up to the underside of the concrete floor slab above with a gap of ~5mm and a continuous bead of acoustic sealant applied along the junction. The sealant can accommodate small deflections/movement of building elements whilst still maintaining a continuous seal.

Noise Transfer Through Ceiling Cavity Floor screed Pre-cast concrete floor slab Plasterboard ceiling on battens Extend plasterboard to ~5mm from underside of slab and apply acoustic sealant Typical section through party wall and floor/ceiling junction

Noise Transfer at Floor Junction Plasterboard wall lining and skirting board not sealed to the floor slab

Noise Transfer at Floor Junction Noise transfer at gap between plasterboard and floor

Noise Transfer at Floor Junction Extend plasterboard to ~5mm from the floor slab and apply acoustic sealant

Junction Details Summary: It is recommended that acoustic sealant is applied to the full perimeter of plasterboard lining to party walls. This reduces noise transfer via the ceiling cavity and at floor level. This simple treatment can provide a noticeable increase in the sound insulation performance of party walls.

ANY QUESTIONS?