Waterproof Digital Refractometer , , , , , & Instruction Manual

Similar documents
Turbidity Meter Instruction Manual

POCKET DIGITAL REFRACTOMETERS

Concentration.

HI Seawater Refractometer INSTRUCTION MANUAL

The J47 and J57 Series of Automatic Refractometers

Operating manual Digital refractometer

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

8000 / 8100 ph Meters

Scientific products for the hydroponics grower

Tracer TM Total Chlorine PockeTester Code 1740

Instruction Manual HI Portable Microprocessor Turbidity Meter

Owner s Manual & Safety Instructions

TN100 PortableTurbidity Meter. Instruction Manual.

INSTRUCTION MANUAL DAFM3

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter

TB100 Portable Turbidity Meter Instruction Manual

P300 ph/mv/t Meter. Manual

Model M130 Mini Anemometer

RJE INTERNATIONAL, INC. STI- 350 R EV 2.2

LP 2000 Microprocessor-based Bench Turbidity Meter

Model E100 Gauss Meter

Instruction Manual. ph20 ph21. Basic ph meters

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

User's Guide. ExStik CL200A. Waterproof Total Residual Chlorine Tester Patent Pending

Cole Parmer Conductivity Meter

Model M120 Mini Temperature/Humidity Meter

Model DDS-11C Conductivity Meter Operation Manual Shanghai San-Xin Instrumentation,Inc.

FRIDGE OWNER S MANUAL

Manual No Revision MODEL GLI HAND-HELD/PORTABLE TOTAL/FREE CHLORINE METER

Instruction Manual HI Portable ph/ec/tds/ C Meters

Model MP511 Lab ph Meter. Operation Manual. Shanghai San-Xin Instrumentation, Inc.

PHS-3D-01 Lab ph Meter. User s Guide. Shanghai San-Xin Instrumentation, Inc.

7 TFT LCD COLOR REAR VIEW SYSTEM

DATA LOGGER Model DL-SA11

PURE WATER METER Model : PWA-301

Hand-Held Refractometers & Optical Instrumentation

IPM Scopes 6/19/2015. The Growers Tool Box. Don t let pests catch you by surprise. Meters & Devices to Improve Plant Quality

Oyster ph - Conductivity - TDS - Temperature Meters

HY-ALERTA 500 Handheld Hydrogen Leak Detector

EPA Compliant Turbidity & Chlorine Meter

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

C300 Cond/TDS/Sal/T Meter. Manual

OPERATING INSTRUCTIONS. Portable Turbidity Meter

GasLab SAN-100 Micro Carbon Monoxide Monitor User Manual

Model 292A. Surface Resistance Test Kit. Instruction Manual

Refractometer Calibration, Use and Maintenance Stephen Vasquez and Shannon Mueller

Typical Experiments. How it Works

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

VAN LONDON COMPANY COMBINATION ph ELECTRODE INSTRUCTION MANUAL

Cole-Parmer Pro-Spense Disposable Syringe Pump User s Manual. Model # (100ml), # (260ml) Publication REV-A

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL

200 Series Benchtop ph/cond. Meter. Instruction Manual

Infrared Thermometer Stock No Part No.IT12:1B

Instruction Manual HI 9124 HI 9125 Portable Waterproof ph Meters

Brine Crystallization Kit Instruction Manual

Model K11. 10ppm Accuracy DC Voltage Standard. Operating Manual

EP100 EMERGENCY POWER BANK

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

NOVALYNX CORPORATION MODEL B & M-B EVAPORATION GAUGE TESTER INSTRUCTION MANUAL

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

DS-520 Digital Indicator Operation Manual 73366

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

L A B D I S S O L V E D O X Y G E N I N S T R U M E N T S

RJE INTERNATIONAL, INC.

Manual Material Thickness Meter PCE-TG1XX

STAINLESS STEEL PEG BOARDS

SAWDUST MOISTURE METER WTR-1E USERS MANUAL

Automated Soluble Salt Meter

HOBO U24 Conductivity Logger (U24-001) Manual

Owner s Manual.

Vernier Software & Technology

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

WARNING! Read all of the information in this booklet, and any relevant Application Notes, before using the Eco Sensors DO3.

user guide CME4 concrete encounter

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

ph / Temperature Meter for Milk with Application Specific Probe

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

HI Portable Logging Turbidity Meter with RS232. Instruction Manual MAN R1 08/05 HI LOG LOBAT DATE TIME CLR VIEW ON OFF STO

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

user guide SKIPPER PLUS non-destructive moisture meter for the marine industry

CO80 Combustion Gas Analyzer

Dissolved Oxygen Probe (Order Code: DO-BTA)

QUAD Rectangular Hinged Door Shower Enclosure Installation Instructions

Engineered Systems & Designs TURBIDITY METER

Instruction Manual HI 9124 HI Portable Waterproof ph Meters

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

WeighSouth. WBT Toploader Balance

HOBO U24 Conductivity Logger (U24-001) Manual

ph & TDS instrumentation 2017 specialists in temperature measuring equipment for over 30 years

Opti-Check Handheld Fluorometer

Installation, Operating & Maintenance Instructions For Tri-Tech Medical Sleep Lab Panel Series

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

UM Owner s Manual

Horticulture Products

Stopwatch Display Timer Owner s Manual

PTSV403. Camera Parking Assist System. Camera PTSV

MODEL NUMBER: 1419 SERIES

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Transcription:

Waterproof Digital Refractometer 300058, 300059, 300060, 300062, 300063, 300064 & 300065 Instruction Manual

Waterproof Digital Refractometer Copyright 2017 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. 2

TABLE OF CONTENTS 1. INTRODUCTION................. 4 2. MATERIALS SUPPLIED............. 5 3. FEATURES.................... 5 4. POWER SUPPLY................. 6 5. FRONT PANEL DESCRIPTION.......... 7 6. LCD DESCRIPTION................ 7 7. CALIBRATION................... 8 8. MEASUREMENT PROCEDURES........ 9 9. ERROR CODES................. 10 10. SCALE INFORMATION.............10 11. SPECIFICATIONS................ 12 12. WARRANTY................... 16 3

INTRODUCTION Housed in a protective rubberized IP65 Waterproof case to safeguard the electronics from wet environments and makes for easy clean ups Model 300058 features a scratchproof sapphire lens.measure samples as small as 1 ml, in the field with laboratory accuracy. Sample temperature is initially displayed on the large LCD followed by the measurement results. The sophisticated microprocessor provides automatic calibration, automatic temperature compensation and automatic shutoff. Powered by a rechargeable, long-life, Li (Lithium Ion) battery providing 50,000 tests on a single charge.simple one-button calibration using distilled water ensures accurate readings. 4

MATERIALS SUPPLIED Refractometer One lithium-ion battery DC Power Adapter Distilled Water Transfer pipet Instruction Manual Carrying Case FEATURES Displays sample temperature followed by measurement result IP65 Waterproof, rugged exterior Rechargeable battery Low battery indicator DC power adapter Automatic shutoff 5

POWER SUPPLY The meter is powered by one rechargeable lithium-ion battery. An icon in the upper-right corner of the LCD indicates the level of battery power available: 75%-100% power 40%-75% power 15%-40% power Less than 15% power. (This icon will flash) The DC adapter included plugs into the port on the left side of the meter. This both provides an alternate power supply and recharges the battery. Automatic Shutoff The power will automatically shut off if the meter is not used for 3 minutes. 6

FRONT PANEL DESCRIPTION 1 2 3 4 1. POWER - Power on/off 2. READ - Read measurements /select scale 3. CAL - Calibrate meter 4. LENS COVER LCD DISPLAY 1. S 1 - Current scale number 2. BATTERY ICON - Battery power level 3. DISPLAY - Displays temperature and readings 7

CALIBRATION Use distilled water (refractive index 1.3330 to 1.3340) to calibrate the meter. 1. With the meter turned off, place a few drops of distilled water on the lens. 2. Close the lid to cover the lens. 3. Press POWER to turn the meter on. 4. The temperature of the distilled water appears on the LCD. 5. Press and hold CAL for 2 seconds to enter Calibration Mode. CAL will be displayed to indicate that calibration is occurring. 6. When calibration is finished the meter returns to Measurement Mode and - - - is displayed on the LCD. Note For best results, calibrate the meter at 20 C. Measurements can be taken at other temperatures, but the calibration should be done at 20 C. 8

MEASUREMENT PROCEDURES After calibration you can remove the distilled water from the lens and begin measurement. Note Use a clean, lint-free cloth or tissue to remove solutions from the lens. 1. With the meter turned off, place a few drops of the solution being measured on the lens. 2. Press POWER to turn the meter on. 3. The temperature of the solution appears on the LCD. 4. Close the lid to cover the lens. 5. Press Read to view the measurement on the LCD. 6. To change scales, press and hold Read for 2 seconds until the scale number changes. Repeat to cycle through the available scales. (see page 10) 7. Press Read if desired to repeat the measurement. 9

MEASUREMENT ERRORS Certain conditions can cause an error code to appear on the LCD: Error Code & Cause HHH LLL The measurement is above the upper limit The measurement is below the lower limit SCALE INFORMATION Scale Indicator & Name - 300058 S1 Brix S2 Refractive Index S3 Dextran S4 Fructose S5 Glucose S6 Lactose S7 Maltose Scale Indicator & Name - 300059 S1 Brix S2 Refractive Index Scale Indicator & Name - 300060 S1 Brix S2 Refractive Index 10

Scale Indicator & Name - 300062 S1 Salinity % S2 Salinity S3 Specific Gravity S4 Refractive Index Scale Indicator & Name - 300063 S1 Cleaner S2 Ethylene Glycol S3 Propylene Glycol S4 Battery Scale Indicator & Name - 300064 S1 Urine Specific Gravity S2 Serum Protein S3 Refractive Index Scale Indicator & Name - 300065 S1 ADBLUE S2 Refractive Index 11

SPECIFICATIONS Unit of Measure Range Accuracy Temperature 0.0 C to 40.0 C ±0.8 C ATC Range 0.0 C to 40.0 C ±0.8 C Sample Capacity 0.3 ml to 1 ml Measurement Time 0.5 to 1.0 seconds Waterproof Rating IP65 Sugars - 300058 Unit of Measure Range Resolution Accuracy Brix 0.0 to 95% 0.1% ±0.2% Refractive Index (nd) 1.3330 to 1.5320 0.0001 ±0.003 nd Dextran 0.0 to 10.6% 0.1% ±0.2% Fructose 0.0 to 68.9% 0.1% ±0.2% Glucose 0.0 to 59.9% 0.1% ±0.2% Lactose 0.0 to 16.5% 0.1% ±0.2% Maltose 0.0 to 15.6% 0.1% ±0.2% Temperature 0.0 to 40 C 0.1 C ±0.8 C 12

Brix 0 to 60% - 300059 Unit of Measure Range Resolution Accuracy Brix 0 to 60% 0.1% ±0.2% Refractive Index (nd) 1.3330 to 1.4420 0.0001 ±0.003 nd Brix 0 to 95% - 300060 Unit of Measure Range Resolution Accuracy Brix 0 to 95% 0.1% ±0.2% Refractive Index (nd) 1.3330 to 1.532 0 0.0001 ±0.003 nd Salinity - 300062 Unit of Measure Range Resolution Accuracy 0 to 28% 0.1% ±0.2% Salinity 0 to 280 1 ±2 Specific Gravity 1.000 to 1.217 0.001 ±0.002 Refractive Index (nd) 1.3330 to 1.3900 0.0001 nd ±0.003 nd 13

Automotive - 300063 Unit of Measure Range Resolution Accuracy *Windshield Washer Fluid 32 to -40 F 0.1 F ±0.2 F Ethylene Glycol 32 to -50 F 0.1 F ±0.2 F Propylene Glycol 32 to -50 F 0.1 F ±0.2 F Battery 1.000 to 1.500 sg 0.001 ±0.005 sg Note... *Windshield Washer Fluid is an aqueous cleaner used in a vehicle s automated spray system. It is not glass cleaner that is applied by hand and wiped with a towel. Windshield Washer Fluid is a mixture that may contain any or all of the following: detergent, methanol, propylene glycol, and silicone polymers. The output of the refractometer is the freezing point of the windshield washer fluid. 14

Clinical - 300064 Unit of Measure Range Resolution Accuracy Urine Specific Gravity Serum Protein g/dl Refractive Index (nd) 1.000 to 1.050 0.001 ±0.002 0 to 12 0.1 ±0.2 1.3330 to 1.3900 0.0001 ±0.003 nd Diesel Exhaust Fluid - 300065 Unit of Measure Range Resolution Accuracy ADBLUE (Diesel Exhaust Fluid) 0 to 40% 0.1% ±0.2% Refractive Index (nd) 1.3330 to 1.4098 0.0001 ±0.003 nd 15

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of one (1) year from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 8281 E. Evans Rd., Suite 103 Scottsdale, AZ 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperwarranty.com within 10 days of purchase. 16 rev. 7/26/2017