Technical Bulletin. No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) hwinsulation CONTRACTORS ASSOCIATION OF AMERICA

Similar documents
Crawl Space Moisture Control

R-Matte Plus-3: Insulation for the Building Envelope

FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

Success with 2009 IECC in Georgia: Tech Tips for Builders. Insulation. Copyright 2014 Advanced Energy. All Rights Reserved

Project Name: Enforcement Agency: Permit Number:

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Standard practice for installing cellulose building insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

CRAWL-SPACE CONSTRUCTION

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

Table Air Barrier and Insulation Inspection Component Criteria

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Deer Ridge Consulting, Inc.

Section 22A. Lead Paint Risk Factor NONE-HIGH FLOOR INSULATION FOR CONVENTIONAL HOMES TABLE OF CONTENTS

Foundations. Issue. Slab-On-Grade Liquid Water Control (See Figure 2-2) Goals. Guidance

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

Feature Zone IECC 2009 IECC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION DIVISION: AIR BARRIERS REPORT HOLDER:

GAF EnergyGuard Polyiso Wall Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

APPLICATION FOR FINISHED BASEMENT PERMIT

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Chapter 4: Insulation

Knauf Makes It Easy to Insulate

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

The Inspection Process. Waxhaw N.C.

Inspection of New One- and Two- Family Dwellings

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

ENCLOSURE: SIMPLE LAYERS

Chapter 2: Foundation

UCC Permit Application Procedures

BUILDING CODES Presented by CORUM ENGINEERING

7/25/2011. THERMAL BARRlERS AND IGNITION BARRIERS. What is a Thermal Barrier? Thermal Barrier Code

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013.

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

7.0 - EXAMPLE DETAILS

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

Where to Draw the Line with Thermal Boundaries

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BAYER MATERIALSCIENCE, LLC

FIELD COPY ATTACHMENT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER: DAP FOAM, INC.

Structural Pest Control Section Division of Plant Industry Georgia Department of Agriculture

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Residential Building Inspections

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Encapsulated, Sealed & Closed Crawlspace Installation Manual

An Introduction to Spray Foam Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS REPORT HOLDER:

Plan Check & Field Inspection Guide

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

Hardin County Planning and Development Commission

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

DIVISION: 07- THERMAL AND MOISTURE PROTECTION Section: Thermal Insulation REPORT HOLDER:

Standards for Jackson EMC s Right Choice Program Revised: June 2011

NEWS LETTER MARCH 27, 2009

Foundation/Site Work Code Requirements

2006 INTERNATIONAL ENERGY CONSERVATION CODE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

INSPECTION GUIDELINES: JOIST AND UNDERFLOOR COMBO

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Willamette Home Inspection

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Supplementary Standard SB-12. Energy Efficiency For Housing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

Module number 3 provides an on-line, self-paced training seminar on chapter 4, foundations and chapter 5, floors from the residential code of ohio.

(Project Location) (your firm's name)

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Only required in new home construction

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

Residential Building Plans

Impact of NFPA 285 on Air Barrier Specification and Design

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

Energy Compliance Information

Energy Compliance Information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

A Design Review of Waterproofing Codes

INSPECTION REQUIREMENTS Page 1 of 5. JOB SITE ADDRESS posted during entire construction process.

Building with Ducts in Conditioned Spaces Conditioned Attics

Transcription:

hwinsulation CONTRACTORS ASSOCIATION OF AMERICA Technical Bulletin 1321 Duke Street, Suite 303 Alexandria, VA 22314 (703) 739-0356 FAX (703) 739-0412 No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) In all cases, consult with the project architect, engineer, or building code official. ICAA Technical Bulletins are provided for informational purposes only. ICAA and/or its members are not responsible for loss or damage caused by errors or omissions or any other cause. SCOPE : This bulletin describes various application techniques for insulating walls and ceilings of basements and crawl spaces. INTRODUCTION : The International Energy Conservation Code establishes minimum energy efficiency standards for insulating basements and crawl spaces. The choice of a particular method or material will depend upon many factors, such as presence of water lines, HVAC ducting and mechanicals, type of floor support structure and subflooring materials, and other building code requirements. This bulletin provides information about where and how various insulation materials should be used to insulate basements and crawl spaces to meet local building code requirements and avoid potential problems. Consult with your local jurisdiction regarding codes in your area. LIMITATIONS : This bulletin does not cover all possible methods and materials suitable for insulating basements and crawl spaces. Recommendations from the material manufacturer should be solicited. However, it remains the final responsibility of the architect/engineer to ensure proper design and application of the materials in question. BASEMENTS : If the basement space is heated or is unconditioned but contains heating units, ducts and pipes, or other appliances, the walls should be insulated instead of the floor/ceiling. If the basement space is unheated, it may be appropriate to insulate the floor/ceiling. As an alternative, insulation may be applied to the walls, and, in some cases, this may be the only alternative. However, insulation should always be applied to the band joist. CRAWL SPACES : Crawl spaces may have cement or dirt floors, provide combustion air to furnaces, and include pipes and ducts. Either the walls or the floor/ceiling should be insulated, but not both. If the floor/ceiling is insulated, all pipes and ducts must be insulated as well. Regardless of where insulation is placed, the entire floor area should be covered with a 4 mil or thicker plastic sheeting (ground cover) extending partially up the vertical wall to reduce moisture problems. Check codes on how far the ground cover should extend up the vertical wall. FLOOR/CEILING : If faced insulation is used, the facing must always be in substantial contact with the subflooring, unless the facing has a Flame Spread Index (FSI) of 25 or less. All types of unfaced insulation and faced insulation with the facing rated FSI of 25 or less are not required to contact the subflooring, and may form an air space between the insulation and subflooring. All types of insulating materials must be securely held in place by means of support rods, wire mesh, netting, drive pins, or other mechanical means. Currently, the International Residential Code requires a vapor retarder on the warm-in-winter side of insulation ; however, some exceptions are granted. Consult with the material manufacturer and the local code official. Plywood subflooring of 1/2 inch thickness or greater may be an approved vapor retarder. There are also approved vapor retarder paints. If an "encapsulated insulation" product is used, the vapor retarder should be installed on the warm-inwinter side of the insulation. Consult with the material manufacturer and the local code official for the proper location of the vapor retarder. Most codes require protection of foam plastic insulation with an approved fire rated barrier unless an exception been granted. Requirements differ for basement and crawl space floor/ceilings. Consult with the material manufacturer and local building codes. All exposed insulation and facings must have a FSI of 25 or less. Refer to the local building code with jurisdiction.

WALLS : When truss type or wood I-beam joists are present, it may be more practical to insulate the walls of the floor/ceiling. Basement or crawl space walls are constructed of masonry or wood framing and may be subject to below grade water leakage from the exterior side. Because of this, particular attention should be given to protecting the insulation from becoming wet and subject to deterioration and loss in R-value. It should be determined whether the exterior of the wall has been treated to reduce or eliminate water leakage. It is a good practice to apply vapor retardant paint or attach an approved vapor retarder to the interior wall surface from one foot above the outside ground level to the floor before insulating. In crawl spaces with dirt floors, plastic film should cover the entire horizontal surface of the ground and at least 6 inches vertically up the walls. This practice will all but eliminate moisture related problems. Insulation should be continuous from the top of the wall to the floor of crawl spaces less than 12 inches in height and should extend horizontally across the floor of crawl spaces for a minimum of 12 inches. When crawl space wall insulation techniques are chosen over floor/ceiling insulation, ventilation is unnecessary and not energy efficient according to today's building scientists. Check building codes as they are subject to change. Vents must be provided, but it is suggested they be closed and insulated if the walls are insulated AND proper moisture control measures have been taken. In regions where termite infestation is common, local code officials may require a continuous 6 inch high "inspection strip" around the perimeter at the top of insulated exterior basement and crawl space walls. This may also be required at the bottom of insulated exterior walls where there is no finished floor (i.e., soil, stone, etc.). In some areas, use of foam plastic insulation below grade on the external of foundation walls is prohibited. Consult with your local building code official. There are many acceptable wall insulation techniques. Some are identified in Figures A - F. For further information, contact the Energy & Environmental Building Association at www.eeba.org. Any rigid, flexible, or spray applied insulation material may be used. Consult with the material manufacturer for proper application techniques. The important criteria is that it remain in place. Most codes require protection of foam plastic insulation with an approved fire rated barrier unless an exception has been granted. Requirements differ for basement and crawl space walls. Consult with the material manufacturer and local building codes. All exposed insulation and facings must have a FSC of 25 or less. Refer to the local building code with jurisdiction. Note that there have been some cases where the foil facing of FSC of 25 or less insulation has given electrical shocks to installers when a "hot" electrical wire is in contact with the facing. Basement walls which will be enclosed with an interior finish should be insulated in the same manner as exterior walls on floors above the basement. Apply insulation to all band joist areas so that it is securely in place. If faced insulation is used, the facing should be in contact with the joist. Many code officials do not permit exposed facings.

WOOD FRAMED INTERIOR BASEVE\T INSULATION I\STALLATION SUBFLOOR BAND JOIST INSULATION (WITH ) JOIST WALL INSULATON WITH VAPOR RETARDER INTERIOR COVERING CONCRETE GRAVEL DRAIN TILE (MIN 4 MIL.) TB 21A

\TTRIOR BOARD-TYPE \SUL_ATIO\ I\STAL_L_ATIO\ 0 SUBFLOOR BAND JOIST INSULATION (WITH FSC 25 ) 1 SILL SEALER JOIST MASONRY WALL 411, ` -1111' =1111 INSULATION WITH FSC 25 FACING WATERPROOF COATING IMPALING PIN WITH PROTECTIVE CAP O APPROVED TAPE (FULL HEIGHT) GRAVEL O DRAIN TILE (MIN 4 MIL.) NOTES: O WHEN FLOOR IS UNFINISHED (IE. SOIL, STONE, ETC.), IN REGIONS OF HEAVY TERMITE INFESTATION, LOCAL INSPECTORS MAY REQUIRE AN "INSULATION STRIP" AT BOTTOM OF THE INTERIOR FOUNDATION WALL. IF SO REQUIRED, INSTALL INSULATION 6" INCHES UP FROM TH BOTTOM OF THE WALL. 2OFOR BASEMENT OR CRAWL (GREATER THAN 12" IN HEIGHT APPLICATIONS.) TB 21B

\TERIOR BATT/BLA\KET INSULATION I\STALLATIO\ SUBFLOOR BAND JOIST INSULATION (WITH FSC 25 ) SILL SEALER JOIST MASONRY WALL WATERPROOF COATING '1i~III- INSULATON WITH FSC 25 FACING 2x4 WOOD FRAMING CONCRETE GRAVEL DRAIN TILE (MIN 4 MIL.) FURRING STRIP NOTES : O WHEN FLOOR IS UNFINISHED (IE. SOIL, STONE, ETC.), IN REGIONS OF HEAVY TERMITE INFESTATION, LOCAL INSPECTORS MAY REQUIRE AN "INSULATION STRIP" AT BOTTOM OF THE INTERIOR FOUNDATION WALL. IF SO REQUIRED, INSTALL INSULATION 6" INCHES UP FROM TH BOTTOM OF THE WALL. TB 21C 2 FOR BASEMENT OR CRAWL (GREATER THAN 12" IN HEIGHT APPLICATIONS.)

1\ TERIOR CRAWL SPACE INSLLATIO\ I\STALLATIO\ O INSULATION O WITH LESS THAN 12" INSULATION WITH (MIN. 4 MIL.) COVERING GROUND NOTES ;O WHEN FLOOR IS UNFINISHED (IE. SOIL, STONE, ETC.), IN REGIONS OF HEAVY TERMITE INFESTATION, LOCAL INSPECTORS MAY REQUIRE AN INSULATION STRIP" AT BOTTOM OF THE INTERIOR FOUNDATION WALL. IF SO REQUIRED, INSTALL INSULATION 6" INCHES UP FROM TH BOTTOM OF THE WALL. 2 FOR CRAWL SPACE APPLICATIONS LESS THAN 12" IN HEIGHT SOME JURISDICTIONS MAY REQUIRE FSC 25 FACING ON EXPOSED CRAWL SPACE INSULATION. TB 21D

EXTERIOR CRAWL SPACE I\SULATIO\ I\STALLATIO\ INSULATION WITH BRICK OR GRAVEL FOR HOLDDOWN (MIN. 4 MIL) TB 21E NOTES :Ol IN REGIONS OF HEAVY TERMITE INFESTATION, LOCAL INSPECTORS MAY REQUIRE A "INSPECTIION STRIP" AT THE TOP OF THE EXTERIOR FOUNDATION WALL, IF SO REQUIRED, INSTALL INSULATION 6 INCHES DOWN FROM THE TOP OF THE WALL. OFOR CRAWL SPACE APPLICATIONS REGARDLESS OF HEIGHT SAME JURISDICTIONS MAY REQUIRE FSC 25 FACING ON EXPOSED CRAWL SPACE INSULATION.

1\ EXT ERIOR BASEVE\T S,LATIO\ I\STALLATIO\ SILL SEALER WATER SHEDDING TOPSOIL LAYER RIGID INSULATION WATERPROOFING MEMBRANE FOOTER DRAINING COARSE GRAVEL f--vapor RETARDER (MIN, 4 MIL.) NOTES : Q1 IN REGIONS OF HEAVY TERMITE INFESTATION, LOCAL INSPECTORS MAY REQUIRE A INSPECTIION STRIP" AT THE TOP OF THE EXTERIOR FOUNDATION WALL. IF SO REQUIRED, INSTALL INSULATION 6 INCHES DOWN FROM THE TOP OF THE WALL. TB 21F

-XTERIOR I\SULATE3 WITI SPRAY APPLI-3 POLYURET - A\ FOAV I\S.~LATIO\ S" MASONRY BLOCK FURRING STRIPS/STUDS SPRAYED POLYURETHANE 0 FOAM MOISTURE RETARDER 1/2" GYPSUM WALLBOARD OR EQUIVALENT SPRAYED POLYURETHANE FOAM POLYURETHANE INSULATION (MIN. 4 MIL.) FOOTING NOTES : CD IN REGIONS OF HEAVY TERMITE INFESTATION, LOCAL INSPECTORS MAY REQUIRE A "INSPECTIION STRIP" AT THE TOP OF THE EXTERIOR FOUNDATION WALL. IF SO REQUIRED, INSTALL INSULATION 6 INCHES DOWN FROM THE TOP OF THE WALL. 2 FOR CRAWL SPACE APPLICATIONS REGARDLESS OF HEIGHT TB 21G

I\TERIOR INSULATED WITH SPRAY APPLIED POLYURETHA\E FOA V I\SULATIO\ O FINISH FLOOR SUBFLOOR FLOOR JOIST SPRAYED POLYURETHANE FOAM APPROVED FSC 25 FINISH NOTES:O WHEN FLOOR IS UNFINISHED (IE. SOIL, STONE, ETC.), IN REGIONS OF HEAVY TERMITE INFESTATION, LOCAL INSPECTORS MAY REQUIRE AN "INSULATION STRIP` AT BOTTOM OF THE INTERIOR FOUNDATION WALL. IF SO REQUIRED, INSTALL INSULATION 6" INCHES UP FROM TH BOTTOM OF THE WALL. TB 21H

BASEMENT CEILI\G INSULATIC\ I\STALLATIO\ SUBFLOOR BAND JOIST INSULATION (WITH ) CEILING INSULATION TIGHT TO FLOOR ABOVE. O CONCRETE GRAVEL DRAIN TILE (MIN 4 MIL.) NOTES;O TO FACE WARM SIDE IN WINTER TB 211