Product Registration Renewal #2 Notice of Proprietary Distribution Product Listing

Similar documents
Product Dimensions (Width x Length x Height) (inches)

July 29, Mr. Wayne Peyton Governmental Affairs Manger Clearstream Wastewater Systems, Inc. PO Box 7568 Beaumont, TX

January 27, Ms. Marie-Christine Belanger Premier Tech Aqua 1 Avenue Premier Riviere-du-Loup (Quebec) G5R 6C1 Canada

February 8, Ms. Robin Cassidy, Customer Services Manager Norweco, Inc. 220 Republic Street Norwalk, OH 44857

APPENDIX B SAND MOUND

NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES DIVISION OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ON-SITE WATER PROTECTION BRANCH

Complex Sewage Disposal Course 2017

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual New York

NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES DIVISION OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ON-SITE WATER PROTECTION BRANCH

Montana. Design and Installation Manual for the Infiltrator ATL TM System in Montana. Infiltrator ATL System in Montana

INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Water Standards and Facility Regulation Harrisburg, PA

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

SECTION 12: Soil Treatment Systems

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE.

Geotextile Sand Filter

To The Applicant For A Small Wastewater System Permit Sheridan County, Wyoming

San Joaquin County. Residential Onsite Systems Bulletin

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Ohio

NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WATER PROTECTION SECTION

Indiana. Design and Installation Manual for the Infiltrator ATL TM System in Indiana. Infiltrator ATL System in Indiana

I. Preconstruction Meeting and Site Preparation Date: Inspector: A. MDE Certified Installer Name

Design and Installation Manual for the Infiltrator ATL System in British Columbia

APPENDIX A LOW PRESSURE DOSED SAND FILTERS

Mono County Health Department Construction Guide for Residential and Commercial On-Site Sewage Treatment & Disposal System I.

Klickitat County. On-Site Sewage System. Construction Manual

INSTALLING A SEPTIC SYSTEM IN LIVINGSTON COUNTY LIVINGSTON COUNTY PUBLIC HEALTH DEPARTMENT 310 TORRANCE AVENUE PONTIAC, IL /

Site Plan: General: Common Omissions-Mistakes on Plans: Ohio EPA Southeast District Office Logan, Ohio November 22, 2005 Bruce Goff, P.E.

Woodford County Health Department 1831 S. Main Street, Eureka, IL Phone: (309) Fax: (309)

Wyoming Water Quality Application Form Permit to Construct Small Wastewater System. Complete attached package and submit to appropriate office:

***NO SEPTIC SYSTEM EXCAVATION WITHOUT AN APPROVED PERMIT IN POSSESSION****

GRAY WATER RECYCLING SYSTEMS

FLOWTECH WASTEWATER TRENCH SYSTEMS Manufactured with 100% Recycled Artificial Aggregate

SANDERS COUNTY ENVIRONMENTAL HEALTH PROPERTY OWNER SEPTIC INSTALLATION BOOKLET

ON-SITE SEWAGE CONTRACTOR EXAMINATION STUDY GUIDE

Name: Company: Address: Telephone: PEI Cert. #

Compliance Inspection Form

777, rue Bay, 2 e etage Toronto, Ontario, M5G 2E5

Section 9: Sand Mounds. 9. Sand Mounds

Australia Design & Installation Manual

RAPID INFILTRATION BASINS REVIEW CHECKLIST

INSTRUCTIONS FOR SUBMITTING A COMMERCIAL SEWAGE DISPOSAL PERMIT APPLICATION

ON-SITE SEWAGE PERMITTING PROCESS

Section 10 Design Criteria: Components

Grand Traverse County Health Department Environmental Health Division. Pressure Mound System (PMS) Policy and Procedure Manual

SMALL WASTEWATER FACILITY APPLICATION PACKET

Ohio. Design and Installation Manual for the Infiltrator ATL System in Ohio. Infiltrator ATL System in Ohio

Pollution Control Agency Rules Relating to Subsurface Sewage Treatment Systems AMENDMENTS TO CHAPTERS 7080, 7081, 7082 AND 7083

Sand Treatment Mound Design Worksheet (page 1 of 7)

Recommended Standards and Guidance for Performance, Application, Design, and Operation & Maintenance

Unit 1 - Introduction, Testing Criteria, and Design Criteria 1-1 Introduction 1-2 Testing Criteria Requirements 1-3 System Design Requirements

SEPTIC TANK CONSTRUCTION GUIDELINES

Geotextile Sand Filter

1.0 BACKGROUND 2.0 DIAGRAMS. The attached diagrams illustrate a typical NDDS system. 3.0 CDPHE OWTS REGULATION #43

2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

QUOTE Quote Process City Of Taylor

APPROVAL FOR GENERAL USE Pursuant to Title 5, 310 CMR Authority for Issuance

Alternate Systems Guidance

Form NDI ON-SITE WASTEWATER SYSTEM NEW DEVELOPMENT INSTALLER INFORMATION Update: September 12, 2014

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Point and Non-Point Source Management Harrisburg, PA

PROCEDURES FOR APPLICATION FOR APPROVAL OF PRIVATE SEWAGE DISPOSAL SYSTEM CONSTRUCTION. January 1, An Interim Document

Geotextile Sand Filter

PSDS Design - Worksheet "M"

Geotextile Sand Filter

PSDS Design - Worksheet "M"

Alternative Dispersal Options

c. Sprinkler layout. Sprinkler layout may be modified to adjust for field conditions provided it complies with part

The Presby Wastewater Treatment System

Pressure Distribution Design

EAGLE DRAINAGE DESIGN STANDARDS

COTTONWOOD IMPROVEMENT DISTRICT SALT LAKE COUNTY SERVICE AREA #3 SOLITUDE IMPROVEMENT DISTRICT TOWN OF ALTA WATERSHED SERVICE LINE SPECIFICATIONS

BMP 6.4.4: Infiltration Trench

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Point and Non-Point Source Management Harrisburg, PA

SECTION TRENCHING

Recommended Standards and Guidance for Performance, Application, Design, and Operation & Maintenance

GEO-flow Pipe Leaching System Specifications & Features. Design & Installation Manual Maine

Foundation/Site Work Code Requirements

Tom Fritts

Other Septic Tank Effluent Dispersal Options

CERTIFICATE OF APPROVED REGISTRATION J. T. BAKER CHEMICAL COMPANY. Sanitary Landfill. Harmony Township. Warren 2110B

Contact Information Owner s Name Home Phone Cell Phone Mailing Address City Zip Code

Pressure Distribution Systems

378 - POND NATURAL RESOURCES CONSERVATION SERVICE CONSERVATION PRACTICE SPECIFICATION I. SCOPE

On-Site Wastewater Application Requirements

#611 ON-SITE TESTING AND EVALUATION

October 6, The Honorable Raymond R. Krause Chief Administrative Law Judge 600 North Robert Street PO Box St. Paul, MN

DRIP EMITTER SYSTEM STUDY GUIDE

Arizona Design & Installation Manual

Contact Information Owner s Name Home Phone Cell Phone Mailing Address City Zip Code

The Presby Wastewater Treatment System

System Design & Installation Manual

Contactor & Recharger Septic Chambers

Design Solutions: Dealing With New Code Issues

On-lot System Component Requirements

LIVINGSTON COUNTY PRIVATE SEWAGE DISPOSAL SYSTEM ORDINANCE

G u i d e l i n e s f o r U s i n g I m p o r t e d S o i l for Onsite Wastewater Systems in Marginal Soil-Site Conditions

Figure 1. Report of Inspection Process Flowchart.

GUIDELINES FOR SEPTIC SYSTEM DESIGN

SECTION EROSION CONTROL DEVICES

Bulletin 4-2 Requirements and Recommendations Page 1

Transcription:

Mr. Dennis F. Hallahan, P.E. Infiltrator Water Technologies 4 Business Park Road PO Box 768 Old Saybrook, CT 06475 RE: Product Registration Renewal #2 Notice of Proprietary Distribution Product Listing Description: Proprietary Distribution Product - Gravelless Distribution Media Manufacturer: Infiltrator Systems Inc. Product Name: Quick4 Chamber Series Numbers: Quick4 Equalizer 24, Quick4 Equalizer 24 Low Profile (LP), Quick4 Equalizer 36, Quick4 Standard, Quick4 Plus Standard, Quick4 Plus Standard LP, Quick4 High Capacity, Quick4 Plus High Capacity Product File No: 2016-006 Dear Mr. Hallahan: Thank you for your application for product renewal dated November 20, 2015, for the Infiltrator Water Technologies Quick4 Chamber Series, which includes the following models: Quick4 Equalizer 24, Quick4 Equalizer 24 Low Profile (LP), Quick4 Equalizer 36, Quick4 Standard, Quick4 Plus Standard, Quick4 Plus Standard LP, Quick4 High Capacity and Quick4 Plus High Capacity. In accordance with Minnesota Rules Chapter 7080 through 7083, the Minnesota Pollution Control Agency (MPCA) has reviewed Infiltrator Water Technologies submitted materials for proprietary distribution product registration. Based on the submitted documentation, the MPCA finds the Quick4 Chamber Series is eligible to be registered and meets the requirements for proprietary distribution product registration. As such, the Quick4 Chamber Series is registered for use in trench, seepage bed, at-grade and mound applications, in accordance with Minnesota Rules Chapter 7080.2200 through 7080.2350 and the manufacturer s installation requirements. Gravity and pressure distribution requirements, as described in Minnesota Rules Chapter 7080.2050, shall be met. Table 1 lists registered chamber models and dimensions as presented in the initial application submittal, dated May 12, 2009, and related documents submitted through March 22, 2011. Subject to this determination, the Quick4 Chamber Series will be placed on the List of Registered Subsurface Sewage Treatment System (SSTS) Proprietary Distribution Media Products at the sizing recommended by the Technical Advisory Panel (TAP) on August 20, 2009, and March 17, 2011, and reflected in this letter of registration. The product information listed in this Notice of Proprietary Product Listing will be maintained on the MPCA website and may not be altered by the manufacturer without permission from the MPCA. wq-wwists4-57

Page 2 Table 1. Infiltrator Quick4 Chamber s and Dimensions Product Dimensions (Width x Length x Height) Average Sidewall Infiltrative Height Quick4 Equalizer 24 Low Profile (LP) 16 x 48 x 8 6 Quick4 Equalizer 24 16 x 48 x 11 9 Quick4 Equalizer 36 22 x 48 x 12 10 Quick4 Plus Standard Low Profile (LP) 34 x 48 x 8 6 7 8 Quick4 High Capacity 34 x 48 x 16 12 Quick4 Plus High Capacity 34 x 48 x 1 Soil absorption areas using Infiltrator Quick4 chambers may be sized based on the sizing charts included in this Notice of Proprietary Distribution Product Listing, or may be sized larger at the direction of local regulatory authorities. Product drawings contained in the manufacturer s manual provide information on the open bottom area for each product listed in Table 1. The following design applications for trenches, seepage beds, at-grades and mounds are based on the Registered Sizing as recommended by the Technical Advisory Panel. When the local regulatory authority chooses to size the Quick4 chamber product based on the chamber inside dimensions, additional calculations will need to be made to determine the number of chambers required in each application. Trench Applications For trench applications, the following shall be the basis for establishing equivalency for nominal chamber width to trench width: A 16-inch-wide chamber is equivalent to an 18-inch-wide trench using drain field rock A 22-inch-wide chamber is equivalent to a 24-inch-wide trench using drain field rock A 34-inch-wide chamber is equivalent to a 36-inch-wide trench using drain field rock Where trench designs are specified, new construction or replacement systems may utilize the Quick4 Chamber Series in accordance with Table 2. Trenches must be no more than 36 inches wide. All excavations wider than 36 inches shall be considered a seepage bed. Table 2. Trench Sizing Dimensions (Width x Length x Height) Quick4 Equalizer 24 Low Profile (LP) 16 x 48 x 8 Quick4 Equalizer 24 16 x 48 x 11 Quick4 Equalizer 36 22 x 48 x 12 Quick4 Plus Standard Low Profile (LP) 34 x 48 x 8 Sizing in Trenches Chamber trench length at 1:1 ratio with drainfield rock trench length Quick4 High Capacity 34 x 48 x 16 20% bottom area reduction for 12 inches of sidewall height

Page 3 Backfilling along the chamber sidewall absorption area shall be done in a manner that: 1) maintains the ability of the soil to adequately infiltrate and disperse wastewater and 2) prevents the intrusion of soil into the chamber through the louvered sidewall. Backfill material type and method of placement shall be done as specified by the manufacturer in the installation manual. The Quick4 High Capacity chamber models utilizing the 20 percent bottom area reduction in trenches shall be installed to utilize the full height of the 12 inch high louvered sidewall for absorption area. The manufacturer s installation manual shall specify how this installation requirement shall be achieved for gravity distribution systems. Vertical inspection pipes must be properly installed in the distribution medium of all trenches as per Minnesota Rules Chapter 7080.2210, subp. 4(B). The inspection pipe must be located at the end opposite from where the effluent enters the distribution medium. The manufacturer s installation instructions for trench systems shall illustrate this requirement. Seepage Bed Applications Seepage bed designs shall be sized based on bottom area only with no additional credit given to sidewall. When a seepage bed is specified with a design width of less than or equal to 12 feet, gravity distribution may be utilized. Seepage bed designs greater than 12 feet and up to 25 feet in width shall require pressure distribution. Table 3 provides Quick4 chamber configurations for seepage bed applications using the Registered Sizing. Table 3. Seepage Bed Sizing Nominal Dimensions Width x Length x Height Infiltrator Chamber Quick4 Plus Standard Low Profile (LP) 34 x 48 x 8 Quick4 High Capacity 34 x 48 x 16 Number of Chambers Bed Design Width Spanning Bed Width (feet) Backfilling along the chamber sidewall absorption area shall be done in a manner that prevents the intrusion of soil into the chamber through the louvered sidewall. Backfill material type and method of placement shall be done as specified by the manufacturer in the installation manual. Vertical inspection pipes must be properly installed in the distribution medium of all seepage bed systems as per Minnesota Rules Chapter 7080.2210, subp. 4(B). The inspection pipe must be located at the end opposite from where the effluent enters the medium. The manufacturer s installation instructions for seepage bed systems shall illustrate these requirements. One inspection pipe per seepage bed is sufficient; it is not necessary to install an inspection pipe in each run of chambers.

Page 4 At-Grade Applications The registration of Quick4 chambers is registered for use in at-grade systems on both flat sites and on sloping sites. At-grade designs shall be sized based on bottom area only with no additional reduction given to sidewall. At-grades should be long and narrow, with individual contour loading rates ranging between two and eight gallons per lineal foot per day. Proper scarification of the absorption area is required before Quick4 chamber products are installed in at-grade systems. The maximum allowable width for at-grade distribution media beds is 15 feet. Table 4 provides Quick4 chamber configurations when utilized in at-grade systems applications using the Registered Sizing. Table 4. At-Grade Sizing Dimensions Width x Length x Height Quick4 Plus Standard Low Profile (LP) 34 x 48 x 8 Quick4 High Capacity 34 x 48 x 16 Number of Chambers Spanning At-Grade Width At-Grade Design Distribution Media (feet) Backfilling along the chambers shall be done in a manner that prevents the intrusion of soil into the chamber through the louvered sidewall. On sites with slopes greater than one percent, geotextile fabric is required over the chambers, as specified in the manufacturer s manual. The required backfill material includes six inches of sandy cover material over the chambers, extending at least five feet beyond the ends of the chambers, and six inches of topsoil. The backfill material shall be properly sloped to divert surface water away from the system. The method of soil placement over the at-grade shall be done as specified by the manufacturer in the installation manual.

Page 5 One vertical inspection pipe must be properly installed along the down slope portion of at-grade absorption beds as per Minnesota Rules Chapter 7080.2230, subp. 3(G). The manufacturer s installation instructions for at-grades shall illustrate this requirement. Mound Applications Mound designs shall be sized based on bottom area only with no additional reduction given to sidewall. Mounds should be long and narrow, with contour loading rates ranging between one and twelve gallon per lineal foot per day. The maximum allowable width for mound distribution media beds is ten feet. Table 5 provides Quick4 chamber configurations when utilized in mound applications using the Registered Sizing. The area around the Quick4 chambers, and in-between the chambers in mounds, shall be filled with clean sand up to the top of the louvered sidewall. The manufacturer s installation manual shall provide a detailed drawing showing this requirement. Table 5. Mound Sizing Product Dimensions (W x L x H) Quick4 Plus Standard Low Profile (LP) 34 x 48 x 8 Quick4 High Capacity 34 x 48 x 16 Numbers of Chambers Spanning Mound Width Mound Distribution Media Width (feet) Backfilling along the chambers shall be done in a manner that prevents the intrusion of soil into the chambers through louvered sidewalls. Backfill material type and method of placement shall be done as specified by the manufacturer in the installation manual. One vertical inspection pipe must be properly installed at the end of each mound, terminating at the mound sand and chamber interface, per Minnesota Rules Chapter 7080.2220, subp. 3(O). The manufacturer s installation instructions for mounds shall illustrate this requirement.

Page 6 Chamber End Caps Each Quick4 chamber model listed is required to be installed with end caps as described in the manufacturer s installation instructions. Although end caps provide some bottom absorption area, this area is not to be included as part of the absorption area for trench, seepage bed, at-grade or mound system designs, unless specifically allowed by the local permitting authority. The manufacturer s manual will specify the absorption area for each Quick4 chamber end cap. General Requirements The registration of products in Minnesota is contingent upon compliance with the following conditions: 1. The manufacturer shall have readily accessible information, specific to a product's registered use in Minnesota, for designers, installers, regulators, system owners, and service providers for the following items: a) product manual; b) design instructions; c) installation instructions; d) information regarding operation and maintenance; e) homeowner instructions; and f) list of manufacturercertified service providers, if any, as required by Minnesota Rules Chapter 7083.4040 (H). 2. Distribution of sewage by means of gravity and pressure are permissible, in accordance with Minnesota Rules Chapter 7080.2050 and the manufacturer s installation requirements. The distribution of effluent shall be done in a manner that does not scour or excessively pit the soil s infiltrative surface or cause sealing from fines at the soil s infiltrative surface. 3. Soil loading rates shall be as specified in Minnesota Rules Chapter 7080.2150, subp.3. Tables IX and IXa and in Minnesota Rules Chapter 7080.2350. 4. No additional consideration shall be given to Quick4 chamber end caps to size trench, seepage bed, at-grade and mound systems, unless specifically allowed by the local permitting authority. 5. The minimum depth of soil cover, including six inches of topsoil borrow, over Quick4 chamber products used in trenches, seepage beds, at-grades and mounds is 12 inches. 6. Any excavation into the absorption area must be in a manner that maintains soil structure in an unsmeared and un-compacted condition. Excavation and placement of Quick4 chamber products are allowed when 1) the soil moisture is less than the plastic limit and 2) the soil is not frozen or freezing per Minnesota Rules 7080.2150, subp. 3 (G). 7. Placement of Quick4 chamber products shall be performed in a manner that minimizes soil compaction due to foot traffic related to the installation of chamber products. 8. Quick4 chamber products shall be installed so they do not: 1) sink, 2) separate, 3) allow for the intrusion of soil into the chambers through the louvered sidewalls, and 4) provide a home for burrowing animals, which partially or completely fills the chamber system with soil. 9. Training shall be provided to practitioners in the proper application and use of the Quick4 chamber products registered for use in Minnesota. 10. During the period of product registration and as part of the renewal process, systems using registered distribution products are subject to an audit established by the MPCA.

Page 7 Please be advised that this registration expires on December 31, 2018. Manufacturers desiring to continue product registration beyond this date must obtain MPCA renewal according to the requirements in Minnesota Rules 7083.4080, subp. 5. If the MPCA finds the product has changed in any way that may affect performance, it may not be renewed and must meet the requirements for initial registration. The MPCA is in no way endorsing these products or any advertising, and is not responsible for any situation which may result from its use or misuse. The MPCA is not liable for any product failure and these statements are not intended and cannot be relied upon to establish any substantive or procedural rights with the state of Minnesota or the MPCA, either express or implied, that can be enforced in litigation or any administrative proceeding. If you have any question, please contact Aaron S. Jensen at 651-757-2544 or by email at Aaron.S.Jensen@state.mn.us. Sincerely, Aaron S. Jensen SSTS Coordinator SSTS Section Municipal Division AJ:wgp cc: File