Tuffy T3 Liquid Level Controls with Electric Switches

Similar documents
TUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

Tuffy II Liquid Level Controls with Electric Switches

Tuffy II Liquid Level Controls with Electric Switches

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

B40 Liquid Level Switch

Thermatel Thermal Dispersion Flow and Level Switches

B40 Liquid Level Switch

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Digital E3 Modulevel Liquid Level Displacer Transmitter

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

Level Switch. Series. instrumentation for fluids LC40. Instructions Manual

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Rosemount 405 Compact Primary Element

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

YPP6870 EXPLOSION-PROOF LOOP-POWERED PROCESS METER

Magnetic float switch For vertical installation Model FLS for nuclear power plants

TL-600 MOBILE PHASE HEATER

Liquid level switch BW 17

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

PD6870 EXPLOSION-PROOF LOOP-POWERED PROCESS METER

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

Mobrey Magnetic Horizontal Float Switches

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

INSTALLATION INSTRUCTIONS

Ball Float Steam Trap UNA 45, UNA 46, UNA 46A PN 40/Class 300 DN 15, 20, 25, 40, 50, 65

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Ground Fault Protection. Medium Voltage Artificial Neutrals

Preparation and Installation of the ENVIRO-SEAL I Rupture Disc

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Thermoelectric Cooler

Flow Measurement SITRANS F M

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

Differential pressure

MS50 Buoyancy level switch. K-TEK products. Measurement made easy. Features. Typical applications

Preparation and Installation of the MX-9T Rupture Disc / MX-9T / MX-9T-RH Holder Assembly

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Distributed By: iprocessmart.com

OPERATOR S MANUAL Model 56A Prefeed / Dereeler

MODEL INSTALLATION INSTRUCTIONS

Installation Instructions, Pressure Regulator Series Manual Model: 20313, Air motor Operated: F20313, Hydraulic Motor Operated: G20313

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

Section 2 Index PAGE 2-I. Metal Sheath and Ceramic Thermocouple Assemblies. AccuTru Sensor Technologies 2-1. Spring Loaded Hex Nipple w/ Head 2-2

1-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series

KEEP FOR FUTURE REFERENCE MRT FORKLIFT ADAPTER READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

A Guide to Level Instrumentation for the Nuclear Power Industry

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

INSTALLATION INSTRUCTIONS. MODEL Version SUMP PUMP

MODEL ZL INSTALLATION INSTRUCTIONS

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Car and Counterweight Frames

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Series Sump and Sewage Systems

NEW GC-16 IN WEST KUWAIT MATERIAL REQUISITION FOR LEVEL GAUGE TABLE OF CONTENTS

OPERATOR S MANUAL Model 27G Rotary Collet Magnet Wire Stripper

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

94110 Vacuum Vent. Features. Vacuum Vent. Less need for special materials in corrosive and extreme temperature

R o L. WAFER PATTERN V-PORT BALL VALVE stainless steel 465 series SILVER LINE. Description. Edition

Diaphragm pressure gauge

BMA-System#3 Technical Application Sheet

ALTOFLUX IFS 4000/4005

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4.

OPTIMASS 7400 Technical Datasheet

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Process Inline Filter, Change-Over

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4.

450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved)

Field case for temperature transmitter Model TIF11

Installation Instructions. Overview. Important Notes. LINCTM Enclosure EDB-WPM-GRX-6-CE

Type Type 2000 Transducers. I/P & E/P Transducers

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

MODELS PH PH PH

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

MODEL INSTALLATION INSTRUCTIONS

Owner's Manual 3,600 Pound Keeperless Cargo Hook Kit. Eurocopter AS350B3

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

Dual Pressure flexitim* System Bently Nevada* Asset Condition Monitoring

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

HIGH SEAL ULF Live Loaded Packing System

STANDARD TECHNICAL SPECIFICATION FOR ROTAMETER VOLUME - IIB. SPECIFICATION No: PE-SS I010

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

WARNING ELECTRIC PALLET TRUCK EPT Revised A company dedicated to solving ergonomic and material handling problems since 1955.

INSTALLATION INSTRUCTION IM 317 E

KPHE20 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

MV en /7 MV Knife gate valve DN

Operating Instructions

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

Table of Contents NEW YORK. Product: Coatings...ii. General Notes...iii. Shipping Notice... iv. Mast Arm Bracket...1. Free-Swinging...

Transcription:

Tuffy T3 Liquid Level Controls with Electric Switches Installation and Operating Manual Side Mounted Float Level Switch

UNPACKING Unpack the instrument carefully. Make sure all components have been removed from the foam protection. Inspect all components for damage. Report any concealed damage to the carrier within 24 hours. Check the contents of the carton/crates against the packing slip and report any discrepancies to Magnetrol. Check the nameplate model number (Model number/approvals as per inserted separate sheet) to be sure it agrees with the packing slip and purchase order. Check and record the serial number for future reference when ordering parts. Nameplate: - partnumber - switch - serial n - tag n For flanged units Cut and remove the plastic shipping straps on flanged units. MOUNTING 0038 0344 These units are in conformity with the provisions of: 1. Directive 94/9/EC for Equipment or protective system for use in potentially explosive atmospheres. Ex d models: EC-type examination certificate number ISSeP10ATEX032. Notified Body: ISSeP, notified body N 0492, Zoning A. Schweitzer, B7340 Colfontaine, Belgium. The following harmonized standards have been applied: EN 60079-0:2009 / EN 60079-1:2007 / EN 60079-26:2007 Ex ia models: EC-type examination certificate number ISSeP00ATEX010X. Notified Body: ISSeP, notified body N 0492, Zoning A. Schweitzer, B7340 Colfontaine, Belgium. The following standards have been applied: EN 50014: 1997 +A1 + A2 / EN 50020: 1994 / EN 50284: 1999 2. The PED directive 97/23/EC (pressure equipment directive). Safety accessories per category IV module H1. Notified body: Lloyd's Register of Shipping, 71, Fenchurch Street, London EC 3M-4BS, UK, notified body N 0038. The following standard has been applied: ANSI/ASME B31.3 Cage mounted Threaded max nozzle length: 84 mm (3.29") Air Oil Water Flanged max nozzle length: 85 mm (3.35") Field adjustable differential max nozzle length: 110 mm (4.35") Interface max nozzle length: 147 mm (5.80") Note: min nozzle size is 3" SCH 80 (max nozzle lengths are specified as per this size) 2" NPT Tuffy Flanged Tuffy External cage mounted Tuffy Locking screw, loosen before removing cover (refasten after replacing) Locking screw, loosen before removing cover (refasten after replacing) 4. Fasten bolts and studs in a star pattern Safety check valve Shut-off valve Pressure vessel Apply Teflon tape or Petrolatum 3/4"NPT cable entry C L C L C L Shut-off valve Switch actuation level M20 x 1.5 or 3/4" NPT cable entry; should always be pointing down Use wrench size 65 mm 3. M20 x 1.5 or 3/4" NPT cable entry; should always be pointing down 1. Install a proper gasket. 2. Cut and remove the shipping straps, slide the control in the nozzle and align the bold holes. Drain valve 2

WIRING CAUTION: power must be switched OFF before wiring the unit. Terminal connections DPDT dry contact switch with silver contacts Terminal connections SPDT dry contact switch with silver or gold contacts External ground wire Internal ground wire use min. 14 AWG wire Terminal connections DPDT dry contact switch with gold contacts Terminal connections SPDT HS switch with silver or gold contacts Allowable operating range Cast iron housing with silver switch contacts with silver/gold contacts HS Allowable operating range Aluminium housing with silver switch contacts with silver/gold contacts HS 60 60 Ambient Temperature ( C) 40 20 0-20 Ambient Temperature ( C) 40 20 0-20 0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350 Process Temperature ( C) Process Temperature ( C) Allowable operating range Cast iron housing with gold switch contacts Allowable operating range Aluminium housing with gold switch contacts 60 60 Ambient Temperature ( C) 40 20 0-20 Ambient Temperature ( C) 40 20 0-20 0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350 Process Temperature ( C) Process Temperature ( C) 3

CALIBRATION For T31-T35 / T3B / T3D and T3E units Properly selected TUFFY units do not need any field calibration. For T3C: field adjustable differential units The Adjustable Differential Tuffy II, model T3C, may be set in the field for one of a variety of level differentials. By specific placement of the stops in the holes of the adjustment plate, the level differential may be changed. L J K H D C B A E F To determine the differential Example: T3C-C unit with stop holes B and G 1. Select the rising level of the upper stop: example: upper stop = hole B: +85 mm 2. Select the falling level of the lower stop: example: lower stop = hole G: -205 mm 3. Substract levels: rising level / upper stop - falling level / lower stop: example: +85 mm - (-205 mm) = +290 mm G Example 2:T3C-8 unit: with stop holes D and B: +183 mm - (+115 mm) = 68 mm Stop holes in mm (divide by 25,4 to obtain inches) Upper stops middle Lower stops Partnumber Level B C D K L A E F G H J T3C-4XXX-XXX Rising +47 +90 +124 +39 +104 +4-37 n/a n/a -42 n/a Falling +80 n/a n/a +84 n/a +38-10 -47-82 +4-62 T3C-8XXX-XXX Rising +63 +131 +183 +51 +153-3 -67 n/a n/a -75 n/a Falling +115 n/a n/a +122 n/a +50-25 -84-136 -3-106 T3C-CXXX-XXX Rising +85 +183 +259 +67 +215-11 -105 n/a n/a -115 n/a Falling +160 n/a n/a +170 n/a 66-43 -128-205 -11-106 Impossible stop hole combinations due to the diameter of the stem (of the float): A and B A and E A and H A and K B and C B and K C and D C and K C and L D and L E and F E and H F and H F and J F and G J and G TROUBLESHOOTING Symptom Failure of the controlled equipment eg. pump does not start, signal lamps fail to operate etc... Cause of malfunction / Action Check external causes first: - blown fuses - tripped reset button - open power switch. - controlled equipment fails. - defective wiring to level switch. Check wiring as per wiring diagrams on page 3 Float magnet Non-magnetic float holder (pressure boundary) Check actuating arm and magnet assembly 1. Remove switch mechanism 2. Check for wiring interference or binding of actuating arm. The switch and magnet must move throughout its entire range of motion without interference. 3. Replace the switch mechanism in case of binding. Check float assembly 1. Remove the unit from service 2. Clean the mechanism if required 3. Tilt the float, when the unit is limited by its motion: check differential setting (for T3C units only) see above 4. Replace the unit in case cleaning and/or resetting did not solve the problem. Switch magnet Magnet/Switch action 4

PREVENTIVE MAINTENANCE Periodic inspections are a necessary means to keep your level control in good working order. This control is a safety device that protects the valuable equipment it serves. A systematic program of preventive maintenance should be implemented when the control is placed into service. If the following instructions are observed, your control will provide reliable protection of your equipment for many years. What to do 1. Keep control clean. Be sure the switch housing is always in place. This cover is designed to keep dust and dirt from interfering with the switch mechanism operation. In addition it protects against damaging moisture and acts as a safety feature by keeping bare wires and terminals from being exposed. Should the housing cover become damaged or misplaced, obtain a replacement immediately. 2. Inspect switch mechanisms, terminals and connections monthly. Tuffy T3 level switches may sometimes be exposed to excessive heat or moisture. Under such conditions insulation on electrical wires may become brittle, eventually breaking or peeling away. The resulting bare wires can cause short circuits. Check wiring carefully and replace at first sign of brittle insulation. Vibration may sometimes cause terminal screws to loosen. Check all terminal connections to ensure that screws are tight. Check wiring carefully and repair or replace if necessary. Note: It is recommended that spare switches, housing covers and o-rings be kept on hand at all times. 3. Inspect entire Tuffy T3 unit periodically. A periodic cleaning of the float and counterweight assembly will ensure continued free movement of the mechanism. What to avoid 1. NEVER leave the switch housing cover off of the control longer than is necessary to make routine inspections. 2. NEVER place a jumper wire across terminals to cut-out the control. If a jumper is necessary for test purposes, ensure that it is removed before placing the control into service. 3. NEVER attempt to make adjustments to or replace switches without reading instructions carefully. When in doubt, consult the factory or your local representative. 4. NEVER use in systems containing iron particles. The magnet in the float assembly can attract the particles and become jammed. 5. NEVER put insulation over the switch housing. REPLACEMENT PARTS ➁ (includes ➀) ➂ ➃ ➀ N Discription Part number Right hand* Left hand* SPDT silver contacts 37-4814-001 not applicable DPDT silver contacts 37-4814-001 37-4814-002 1 Switch SPDT gold contacts 37-4814-003 not applicable only DPDT gold contacts 37-4814-003 37-4814-004 HS SPDT silver contacts 37-9101-001 37-9101-001 HS SPDT gold contacts 37-9102-001 37-9102-001 SPDT silver contacts DPDT silver contacts 2 Switch SPDT gold contacts Consult factory mechanisms DPDT gold contacts HS SPDT silver contacts HS SPDT gold contacts 3 Housing cover Aluminium 04-9197-005 Cast Iron 04-9197-002 4 Cover o-ring 12-2201-240 * Position of the switch is determined by looking at the terminal block with the cable entry pointing downward. 5

SPECIFICATIONS PHYSICAL SPECIFICATIONS Description Specification Measured variable Liquid level Physical range Narrow differential: 13 mm (0.5") Adjustable differential: up to 464 mm (18.26") Interface Service Differential: 44 mm (1.72") Interface: min S.G. difference between both liquids: 0,1 Ambient temperature C to + 70 C ( F to +160 F) Process temperature From -55 C (-65 F) up to 400 C (750 F) depending switch/housing selection Process pressure Standard models: up to 50 bar abs. (720 psi) High pressure models: up to 150 bar abs. (2160 psi) Wetted parts 316/316L (1.4401/1.4404) or Hastelloy C (2.4819) Flange materials Carbon steel 316/316L (1.4401/1.4404) or Carbon steel with 316/316L (1.4401/1.4404) cladding Hastelloy C (2.4819) or Carbon steel with Hastelloy C (2.4819) cladding Housing materials Cast aluminium or cast iron ELECTRICAL SPECIFICATIONS Description Specification Switch ratings Up to 10 A @ 240 V AC Up to 6.0 A @ 24 V DC Signal output Single SPDT or single DPDT contacts Switch types Dry contact with silver or gold plated contacts Hermetically sealed for corrosive environment Approvals ATEX II 1/2 G / IECEx Ex d IIC T6 Ga/Gb, explosion proof ATEX II 1G EEx ia II C T6, intrinsically safe NEMA 4X/7/9, Class 1, Div 1, Groups B, C & D Cable entries 3/4" NPT or M20 x 1,5 6

DIMENSIONS in mm (inches) T31 and T35: threaded narrow differential 211 (8.29) 84 (3.29) T31: 220 (8.66) T35: 200 (7.86) 112 (4.39) T31: 91 (3.59) T35: 85 (3.33) Cable entries: M20 x 1.5 or 3 /4" NPT 2" NPT T31, T33 and T35: flanged narrow differential 211 (8.29) 85 (3.35) T31: 221 (8.72) T33: 190 (7.50) T35: 201 (7.92) 112 (4.39) T31/T33: 91 (3.59) T35: 85 (3.33) Cable entries: M20 x 1.5 or 3 /4" NPT T32: flanged high pressure narrow differential 211 (8.29) 85 (3.35) 204 (8.02) 112 (4.39) 85 (3.35) Cable entries: M20 x 1.5 or 3 /4" NPT T3C: adjustable wide differential 209 (8.23) 85 (3.35) Stem length (code 4): 327 (12.86) Stem length (code 8): 422 (16.61) Stem length (code C): 543 (21.36) 112 (4.39) Stem length (code 4): 346 (13.62) Stem length (code 8): 471 (18.54) Stem length (code C): 629 (24.76) Cable entries: M20 x 1.5 or 3 /4" NPT Stem length (code 4): 95 (3.75) Stem length (code 8): 190 (7.50) Stem length (code C): 311 (12.25) 7

DIMENSIONS in mm (inches) T3B: interface 209 (8.23) 85 (3.35) 448 (17.62) 112 (4.39) 172 (6.78) Cable entries: M20 x 1.5 or 3 /4" NPT 8

MODEL IDENTIFICATION T 3 1 Tuffy with 316/316L (1.4401/1.4404) float - min S.G. 0,4 / max 50 bar abs (720 psi) T 3 2 Tuffy with 316/316L (1.4401/1.4404) float - min S.G. 0,6 / max 150 bar abs (2160 psi) T 3 3 Tuffy with Hastelloy C (2.4819) float - min S.G. 0,65 / max 50 bar abs. (720 psi) T 3 5 Tuffy with 316/316L (1.4401/1.4404) float - min S.G. 0,6 / max 103 bar abs (1500 psi) T 3 B Interface Tuffy with 316/316L (1.4401/1.4404) float - max 50 bar abs (720 psi) T 3 C Adjustable diff. Tuffy with 316/316L (1.4401/1.4404) float - min S.G. 0,78 / max 50 bar abs (720 psi) NARROW DIFFERENTIAL UNITS - T31, T32, T33 AND T35 O Standard level differential of 13 mm (0,5") SPECIFIC GRAVITY OF LOWER LIQUID FOR T3B 0,81 0,82 0,83 0,84 0,85 0,86 0,87 0,88 0,89 0,90 Specific Gravity A B C D E F G H J K Code 0,91 0,92 0,93 0,94 0,95 0,96 0,97 0,98 0,99 1 Specific Gravity L M N P R S T U V W Code STEM EXTENSION LENGTH FOR T3C - DIMENSION "A" 4 95 mm (3.75") stem extension / 346 mm (13.62") differential 8 190 mm (7.50") stem extension / 471 mm (18.54") differential C 311 mm (12.25") stem extension / 629 mm (24.76") differential PROCESS CONNECTION ANSI Flanges 3 A 3" 150 lbs RF ANSI Flange 3 B 3" 300 lbs RF ANSI Flange 3 C 3" 600 lbs RF ANSI Flange 3 D 3" 900 lbs RF ANSI Flange 4 A 4" 150 lbs RF ANSI Flange 4 B 4" 300 lbs RF ANSI Flange 4 C 4" 600 lbs RF ANSI Flange 4 D 4" 900 lbs RF ANSI Flange 5 A 5" 150 lbs RF ANSI Flange 5 B 5" 300 lbs RF ANSI Flange 6 A 6" 150 lbs RF ANSI Flange 6 B 6" 300 lbs RF ANSI Flange PROCESS CONNECTION THREADED 2 N 2" NPT connection PROCESS CONNECTION EN/DIN Flanges A 1 DN 80, PN 16 EN 1092-1 Type B1 A 2 DN 80, PN 25/40 EN 1092-1 Type B1 A 3 DN 80, PN 63 EN 1092-1 Type B2 A 4 DN 80, PN 100 EN 1092-1 Type B2 A 5 DN 80, PN 160 DIN 2527 Form E flange B 1 DN 100, PN 16 EN 1092-1 Type B1 B 2 DN 100, PN 25/40 EN 1092-1 Type B1 B 3 DN 100, PN 63 EN 1092-1 Type B2 B 4 DN 100, PN 100 EN 1092-1 Type B2 B 5 DN 100, PN 160 DIN 2527 Form E flange C 1 DN 125, PN 16 EN 1092-1 Type B1 C 2 DN 125, PN 25/40 EN 1092-1 Type B1 D 1 DN 150, PN 16 EN 1092-1 Type B1 D 2 DN 150, PN 25/40 EN 1092-1 Type B1 SEE PAGE 10 T 3 0 complete code for TUFFY T3 9

MODEL IDENTIFICATION SEE PAGE 9 DESIGN CODE AND FLANGE MATERIAL Design codes Standard ANSI/ NACE ANSI/ASME Flange material ASME B31.3 B31.3 & NACE 1 2 3 ➀ 4 ➀ Carbon steel A E J N Carbon steel w. 316/316L cladding B F K P 316/316L (1.4401/1.4404) stainless steel C G L R Carbon steel w. Hastelloy C cladding D H M T Hastelloy C (2.4819) ➀ Not for all models SWITCH TYPE (see table below - "SWITCH MECHANISMS") 0 SPDT with silver contacts 1 DPDT with silver contacts 2 SPDT with gold plated contacts 3 DPDT with gold plated contacts 4 Hermetically sealed, SPDT with silver contacts 6 Hermetically sealed, SPDT with gold plated contacts HOUSING MATERIALS AND CABLE ENTRY Consult factory for proper partnumbers for FM/CSA approved units 1 Cast aluminium, single 3 /4" NPT cable entry, ATEX II 1/2G / IECEx Ex d II C T6 Ga/Gb 2 Cast iron, single 3 /4" NPT cable entry, ATEX II 1/2G / IECEx Ex d II C T6 Ga/Gb 3 Cast aluminium, single M20 x 1,5 cable entry, ATEX II 1/2G / IECEx Ex d II C T6 Ga/Gb 4 Cast iron, single M20 x 1,5 cable entry, ATEX II 1/2G / IECEx Ex d II C T6 Ga/Gb M Cast aluminium, single 3 /4" NPT cable entry, ATEX II 1G EEx ia II C T6 N Cast iron, single 3 /4" NPT cable entry, ATEX II 1G EEx ia II C T6 P Cast aluminium, single M20 x 1,5 cable entry, ATEX II 1G EEx ia II C T6 R Cast iron, single M20 x 1,5 cable entry, ATEX II 1G EEx ia II C T6 T 3 complete code for TUFFY T3 SWITCH MECHANISMS All TUFFY are available with a selection of switch modules that vary in switch rating (Amp) and max process temperature allowance. The max temperature is dependent upon the housing material selected. Consult table below, before selecting the proper module in the order number structure on pages 9 or 10. Electric switch rating Process temperature range V AC V DC @ 40 C (100 F) ambient temp. Code Contacts and type 120 240 24 120 Cast Iron Cast Aluminium 0 SPDT with silver contacts 10.0 10.0 6.0 0.6 C to +400 C ( F to +750 F) C to +345 C ( F to +650 F) 1 DPDT with silver contacts 10.0 10.0 6.0 0.6 C to +400 C ( F to +750 F) C to +345 C ( F to +650 F) 2 SPDT with gold plated contacts 0.1-0.1 - C to +190 C ( F to +375 F) C to +160 C ( F to +325 F) 3 DPDT with gold plated contacts 0.1-0.1 - C to +190 C ( F to +375 F) C to +160 C ( F to +325 F) 4 HS SPDT with silver contacts 1.0 1.0 3.0 0.5-55 C to +400 C (-65 F to +750 F) -55 C to +345 C (-65 F to +650 F) 6 HS SPDT with gold plated contacts 0.5 0.5 0.5 0.5-55 C to +400 C (-65 F to +750 F) -55 C to +345 C (-65 F to +650 F) 10

11

IMPORTANT SERVICE POLICY Owners of Magnetrol products may request the return of a control; or, any part of a control for complete rebuilding or replacement. They will be rebuilt or replaced promptly. Magnetrol International will repair or replace the control, at no cost to the purchaser, (or owner) other than transportation cost if: a. Returned within the warranty period; and, b. The factory inspection finds the cause of the malfunction to be defective material or workmanship. If the trouble is the result of conditions beyond our control; or, is NOT covered by the warranty, there will be charges for labour and the parts required to rebuild or replace the equipment. In some cases, it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the original equipment before it is returned. If this is desired, notify the factory of both the model and serial numbers of the control to be replaced. In such cases, credit for the materials returned, will be determined on the basis of the applicability of our warranty. No claims for misapplication, labour, direct or consequential damage will be allowed. RETURNED MATERIAL PROCEDURE So that we may efficiently process any materials that are returned, it is essential that a Return Material Authorisation (RMA) form will be obtained from the factory. It is mandatory that this form will be attached to each material returned. This form is available through Magnetrol s local representative or by contacting the factory. Please supply the following information: 1. Purchaser Name 2. Description of Material 3. Serial Number and Ref Number 4. Desired Action 5. Reason for Return 6. Process details All shipments returned to the factory must be by prepaid transportation. Magnetrol will not accept collect shipments. All replacements will be shipped FOB factory. UNDER RESERVE OF MODIFICATIONS BULLETIN N : BE 44-605.9 EFFECTIVE: FEBRUARY 2014 SUPERSEDES: October 2010 www.magnetrol.com BENELUX FRANCE DEUTSCHLAND Heikensstraat 6, 9240 Zele, België -Belgique Tel. +32 (0)52.45.11.11 Fax. +32 (0)52.45.09.93 E-Mail: info@magnetrol.be Alte Ziegelei 2-4, D-51491 Overath Tel. +49 (0)2204 / 9536-0 Fax. +49 (0)2204 / 9536-53 E-Mail: vertrieb@magnetrol.de INDIA C-20 Community Centre, Janakpuri, New Delhi - 110 058 Tel. +91 (11) 41661840 Fax +91 (11) 41661843 E-Mail: info@magnetrolindia.com ITALIA Via Arese 12, I-20159 Milano Tel. +39 02 607.22.98 Fax. +39 02 668.66.52 E-Mail: mit.gen@magnetrol.it RUSSIA 198095 Saint-Petersburg, Marshala Govorova street, house 35A, office 427 Tel. +7-812.702.70.87 E-Mail: info@magnetrol.ru U.A.E. DAFZA Office 5EA 722 PO Box 293671 Dubai Tel. +971-4-6091735 Fax +971-4-6091736 E-Mail: info@magnetrol.ae UNITED Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL KINGDOM Tel. +44 (0)1444 871313 Fax +44 (0)1444 871317 E-Mail: sales@magnetrol.co.uk