Trenchless building entries Power and communication. Always. Reliable. Tight. cablepipebuildingentry+ Advantages:

Similar documents
Single building entries Power and communication. Always. Reliable. Tight. cablepipebuildingentry+ Advantages:

Always. Reliable. Tight. Cable sealing system Cable entry system KES-M90. cablepipebuildingentry+

Cable entries and earthings for secondary substations and industrially manufactured technical buildings

Always. Reliable. Tight.

Always. Reliable. Tight. CATALOGUE CABLE ENTRIES.

FRANK Puddle Flanges. The Original. Geosynthetics

TEST REPORT e/BDM100/H-2

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

Installation Instructions

Keyhole Technology House connections installed with minimal invasion using the trenchless method

Box sealing system DS 90

Press Release. Rehabilitation of oil pipelines with flexible high pressure pipes

TEST REPORT e/UDM100/H-2

Sealing solutions against constant water pressure CABLE AND PIPE SEALS FOR UNDERGROUND APPLICATIONS

No-Dig Technology is the art and science of pipes, ducts and cables using techniques that minimizes / eliminates the need for excavation, i.e.

PRODUCT DATA SHEET. SikaFuko Eco-1 PRODUCT- DESCRIPTION. Re-injectable hose for sealing construction joints in watertight structures

Premium partner Made in Germany

PETREX -CNT. Pipe systems for petrol stations Technical details

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

Multi-Gard PVC Assembly/ Field Cuts

Construction. Injectable hose for sealing construction joints in watertight structures. Product Description. Product Data. Tests.

PlastCoat PC 25/ PC 35

RTM ACCESSORIES. MOLD SEALS ( Packing : 25LM Rolls ) Standard Dynamic Seal White. Medium Dynamic Seal Blue. Primary seal for Hollow Dynamic Seal

PRODUCT OVERVIEW CABLE AND PIPE SEALING SYSTEMS BUILDING INDUSTRY

Injectable hose for sealing construction joints in watertight structures

Bridge Drainage Systems

POLYESTER INJECTION MORTAR Good Quality and Competitve Price

PRODUCT DATA SHEET. SikaFuko VT PRODUCT- DESCRIPTION

Miller Collective Safety at Height Solutions EPIC ULTRA Barrier System EPIC Post-N-Barrier System EPIC Basic Barrier System

PRODUCT OVERVIEW CABLE AND PIPE SEALING SYSTEMS BUILDING INDUSTRY

FLEXWELL FHK. Flexible district heating pipe

SceptaCon Trenchless Raceway for Electrical and Telecommunication Cables

LK Manifold Cabinet UNI, LK Prefab Cabinet UNI

INDUSTRIAL POLY-FLO DOUBLE CONTAINMENT PIPING SYSTEM DOUBLE SAFETY!

Technical data No. 17/0001 of 25/04/2017

+44 (0)

thoroughly tried and tested! Performance Profile Fittings for Water, Gas and Waste Water

Conergy SolarFamulus II

Valmont Newmark is your single source for steel, concrete or hybrid structures for power delivery

GEONFLEX - GEONDUR. New double structured wall conduits (HDPE) for underground networks

CI/SfB (52.5) January 2004 Uniclass L L2123. ACO LightShaft Daylight and fresh air. Naturally.

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MPR MODULAR WALL AND CASING SEAL

DRAINAGE GUTTERS FOR DRAIN ASPHALT 2012 TECHNICAL CATALOGUE

Basement drains. with/without backwater protection. Ideal. Project drains. Floor/Bathroom drains. Shower channels. Basement drains

Injection Adhesive VM-PY

Construction. Injectable Hose for Sealing Construction Joints in Watertight Structures. Product Description. Tests. Product Data

Bore-Gard. Boreable Multi-Gard Assembly Multi-Gard Trenchless Raceway

Reinforced concrete double walls

Injectable Hose With Integral Valves for Sealing Construction Joints in Watertight Structures

Installation instructions. LORO-ATTIKASTAR siphonic drains

SHREE DUJA SPRAY EQUIPMENTS

WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

Injectable hose with integral valves for sealing construction joints in watertight structures

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

T TABLE OF CONTENTS SPUNWRAP COLLAR

DRILLING MACHINES FOR SPECIAL APPLICATIONS 2017

PACTORep Fixer EASF AVAILABILITY. Working Hardening 3h 2h 1h30 1h Anchor Installation Resistance Admissible loads

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

Construction. Universal anchoring adhesive. Product Description 1 1/7. Product Data Sheet Edition _1 Sika AnchorFix -S

Materials Polyester Resin Anchors: Carbon Steel grade 5.8 Stainless Steel: AISI 316

No Dig renovation and installation of systems using polyolefin pipes

TEST REPORT e/AT100/H-2

P R E - I N S U L AT E D PIPE SYSTEMS COMPRESSION WALL SEAL INSTALLATION GUIDE. Compression Wall Seal Installation Guide

Injectable hose with integral valves for sealing construction joints in watertight structures

Energy Systems. Rainwater utilisation. Mini-wastewater treatment plants and cesspits. Living full of energy

Reinforced concrete double walls

PSI Compakt Seals and Wall Sleeves with Fixed / Loose Flange

Solutions Railing Overview ACTUAL FREIGHT CHARGES APPLY TO ALL SOLUTIONS RAIL ORDERS

WATERPROOFING OF WET ROOms

Construction. Injectable hose with integral valves for sealing construction joints in watertight structures. Product Description. Product Data.

Cornerview Shower Enclosure & Base

Omega seals Trelleborg Ridderkerk BV

MAKING MODERN LIVING POSSIBLE. Danfoss Pipes for Hydronic Floor Heating. Handbook DANFOSS HEATING SOLUTIONS

connectors Shaft connectors application area: material designation: standard: Diameter: colours: sealing ring system: packaging types:

KELIT PEX 95R-10 KELIT PEX 115R-16 %URFKXUH

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

H. Underground Transmission System Design

Combi climate glands. Product information 06/2009

INOFIN FPO roofing membrane

Welcome to the market leader for state-of-the-art micro duct systems

Pipe Flashing Systems

FABRICATION OF A NEW INDUCED DRAUGHT FAN DUCTING KILN 2

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Always. Reliable. Tight. Catalogue 2014 Cable Entries. Prices valid as of cablespipesbuildingentries +

SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts

Fastening Injection System ResiFIX

INDUSTRIAL PIPE FITTINGS, LLC

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

TRENCHLESS TECHNOLOGY. Department of Civil Engineering.

PERFECT PIPE THE REVOLUTION CONTINUES

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

Model No. BWTDWFK-TRIFLO.

Guidance on Avoiding Danger from Underground Electricity Cables based on HSE Document HS(G)47

INSTALLATION GUIDE. 4-Post Lift. Model United States. United Arab Emirates. Egypt.

8000 PIVOT EXPORT 6-5/8" PIPE 90" COUPLER SPACING

DROSSBACH HD Series Corrugated Plastic Pipe Machines.

TANK SUMPS SINGLE WALL & DOUBLE WALL

MHST 20 lifting/sliding door threshold

Transcription:

Always. Reliable. Tight. Advantages: no need to dig a trench on the outside of building can be fully installed from the inside of building ideal for applications where the connection line for the house is difficult to access or built over Trenchless building entries Power and communication cablepipebuildingentry+

Trenchless installation technology No need for digging. Reliable. Tight. While it's not always possible to accommodate trenchless installation of building connection lines, this method offers a perfect system for all supply lines and is becoming increasingly common thanks to the sustainable technical and economic advantages it affords. With some good planning and construction site logistics, you can establish several building connections each day. All the while, the easy-to-use soil displacement hammer handles its tasks with the utmost accuracy and reliability. The duct to be laid is installed directly using the soil displacement hammer. Not only does this protect the user's lovingly tended front garden, but it is also much less stressful for all those involved. This is because Hauff-Technik's protective and flexible solution resolves any complaints or worries regarding damage to surfaces or stairs before they can even develop. The choice is yours with either the new, innovative MIS single building entry system or the proven and highly efficient ZAPPO tunnelling technology, you can install a sealed electrical or communications cable connection safely without the need for extensive underground engineering work. Soil displacement hammers are used to drive either ducts or driving pipes through a core drill hole into a destination trench from the inside of the building using trenchless technology. The driving pipes are securely connected using sleeve technology and can have an outer diameter of 75 mm or 63 mm (63 mm driving pipe not in product range). Once the cables have been drawn, the ducts are either removed or left as empty ducts in the ground. Use of the trenchless installation procedure requires extensive training. Please get in touch with us for more information. 2

MIS The membrane injection system The MIS (membrane injection system) is a universal building entry for bore holes in the most common types of walls. It is used to provide a gastight and watertight seal for building connections. The injection membrane provides targeted and controlled resin injection and significantly shortens building connection installation times. For the trenchless variant, there are two different versions: MIS 60 NoDig or MIS 00/VT63 NoDig. However, whichever MIS you choose, the MIS building entry can be used universally in new builds or renovations, both in brickwork or concrete. MIS 60 NoDig Cable Pipe Protects the cable and facilitates both retrofit installation and cable replacement. Membrane hose This has numerous small cuts for controlling and monitoring the resin injection. Flange This controls resin leakage on the wall of the building. Wall rosette This finishes off the connection neatly on the inside of building. Resin Expands beyond the bore diameter. Sealing lips These seal and protect the cables. A core drill hole with a diameter of between 62 and 65 mm is drilled into the building's cable connection area. The soil displacement hammer with Ø 55 mm is driven through the core drill hole into the destination trench. The duct, through which the actual micropipe/cable will later be pushed, is also fed in. The building entry is then inserted from the basement side via the micropipe/cable in the core drill hole and put into position. The membrane hose and flange create an optimal seal. Assembly kit consisting of: Ponal PP6/PP2 cartridge gun MIS 00/VT63 quick tensioning device ¼" reversible ratchet angled screwdriver quick deburrer side cutters ¼" extension, 50 mm various sockets centring pipe distance terminals MIS No Dig assembly kit The tools have been specially developed and put together for using trenchless construction methods with the MIS 00/VT 63 No Dig. These tools allow you to assemble the MIS building entry safely and reliably. cablepipebuildingentry+ 3

MIS The membrane injection system MIS 60 NoDig The MIS 60 NoDig can be relied upon for effective sealing of micropipes/fibre-optic cables, telecommunications cables and power cables. Cable sealing is achieved without additional shrinking and smoothly using 5 different seal inserts, which are pre-assembled in accordance with customer requirements. Article code: MIS 60-ND/6-2 inclusive wall rosette, 2-component resin im 3000 inclusive mixing nozzle, cleaning brush for the core drill hole and quick tensioning device tubular guide elbow (available as an accessory) The quick tensioning device is a reusable tool and can be ordered separately if required: MIS 60-SVS. The cleaning brush for core drill holes is a reusable tool and can be ordered separately if required: MIS 40/60-REB. The tubular guide elbow is available as an optional accessory and can be used on cables up to 6 mm: MIS 60-RB. Core drill hole/ wall duct ID (mm) Buildings with a basement 62 65 4 Number of cables/ medium Suitable for medium pipe OD (mm) Overall length Packing unit Article code Article number 30 34,300 mm 0 pieces MIS 60-ND/30-34 29000026 24 30,300 mm 0 pieces MIS 60-ND/24-30 29000027 8 24,300 mm 0 pieces MIS 60-ND/8-24 29000028 2 8,300 mm 0 pieces MIS 60-ND/2-8 29000029 6 2,300 mm 0 pieces MIS 60-ND/6-2 290000220 3 0,300 mm 0 pieces MIS 60-ND/3x0 290000222 4 5 7,300 mm 0 pieces MIS 60-ND/4x5-7 29000022

MIS The membrane injection system MIS 00/VT63 NoDig Octagonal inner sealing element inclusive closed sealing element These finish off the connection neatly on the inside of building. Membrane hose This has numerous small cuts for controlling and monitoring the resin injection. Flange Controls resin leakage on the wall of the building. Sealing lips These ensure a gentle seal on the medium pipe. The 63 mm driving pipe is driven into the ground together with the soil displacement hammer. Resin injection hose Pipe sleeve This protects the medium pipe and facilitates retrofit installation. A core drill hole with a diameter of 00 mm is drilled into the building's cable connection area. The soil displacement hammer with Ø 75 mm is driven through the core drill hole into the destination trench. The 63 mm duct, through which the actual cable(s) will later be pushed, is also fed in. The building entry seal is also achieved here using the 2-component resin; cable sealing is achieved using the corresponding closed sealing element. cablepipebuildingentry+ 5

MIS The membrane injection system A MIS for every application The MIS 00/VT63 NoDig is a perfect and reliable seal for installing electrical cables between 20 and 34 mm and for up to five telecommunications cables between 5 and 2 mm in a gastight and watertight manner in bore holes with Ø 00 mm. Illustration: Illustration: MIS 00/VT63-ND with driving pipe and Power closed sealing element fitted communication closed sealing element Article code: MIS 00/VT63-ND (driving pipe and closed sealing element not included) Not supplied with the product but necessary tool/item for installation (available to order separately): The reusable quick tensioning device: MIS 00/VT63-SVS. 2-component resin M 3000 inclusive mixing nozzle 300 ml: EH 300/400 (Packing unit = 6 pieces) Electrical ED /20-34 Core drill hole ID (mm) 99 02 6 KD /3-2+3/7-3+/5-3 Electrical/communication ED/KD /26-30+3/5-8+2/7-3 Number of cables/ medium Medium Article code MIS Article number MIS Article code Sealing element Article number Sealing element Electrical cable MIS 00/VT63-ND 2900300450 ED /20-34 5500067 5 cable MIS 00/VT63-ND 2900300450 KD /3-2+3/7-3+/5-3 55200045 6 Electrical and fibre-optic cable MIS 00/VT63-ND 2900300450 ED/KD-/26-30+3/5-8+2/7-3 9800004

ZAPPO single building entry for power and communication ED /20-34 Outer sealing element Driving pipe Wall Inner sealing Resin injection 2-component injecelement hose tion resin barrier Sponge rubber Features and technical data: gas- and watertight up to bar quick assembly in just a few minutes suitable for all lines After the empty pipeline has been laid, the outer sealing element is assembled on the inside of building. The outer sealing element is a 30 mm thick rubber press seal through which an injection hose is fed. A 2-component expansion resin is piped through this hose at the external wall and seals the building entry at the ground. This means that the existing outer wall seal can be fully restored. Finally, the inner seal is installed. This consists of a 40 mm rubber press element, an octagonal flange and the corresponding closed sealing element. Article code: ESH Basic-M-VT75 Illustration: Electrical cable Article code: ESH Basic-M-VT75 Illustration: cable Medium Article code Inclusive sealing element Article number Delivery inclusive fasteners, protective caps and closed sealing element. Core drill hole/ wall duct ID (mm) Driving pipe Number of OD (mm) medium 75 Electrical cable ESH Basic-M-VT75 ED /20-34 920003400 75 cable ESH Basic-M-VT75 KD /4-2-3/7-3-/5-3 920003500 63 Electrical cable ESH Basic-M-VT63 ED /d (d = cable outer diameter) 920003405 63 cable ESH Basic-M-VT63 KD x/d (x = number d = cable outer diameter) 920003405 99 03 cablepipebuildingentry+ 7

Electrical ED /20-34 Sleeve caps MS75-U /24-52 KD /3-2+3/7-3+/5-3 Sleeve caps MS75-KD /3-2+3/7-3+/5-3 Electrical/communication ED/KD /26-30+3/5-8+2/7-3 Sleeve caps MS75-EW /24-40-3/7-2 ZAPPO assembly kit Article code: MK 63/75 2-component resin im 3000 inclusive mixing nozzle Assembly kit consisting of: setting tool drive mandrel centring sleeve cartridge gun allen key centring pipe quick deburrer side cutters various sockets reversible ratchet Assembly kit The tools have been specially developed for the trenchless construction sector. They enable the ZAPPO building entry to be installed efficiently and reliably. ZAPPO driving pipe Article code: ESH Basic-M-VR 75/000 Colour: black Packing unit = 9 pieces or 02 pieces DN 75 driving pipe for power and communication cables Hauff-Technik GmbH & Co. KG Robert-Bosch-Straße 9 89568 Hermaringen, GERMANY Phone Fax +49 7322 333-0 +49 7322 333-999 office@hauff-technik.de www.hauff-technik.de einzelhauseinf_grabenlos_strom-komm_en_6082 The information in this publication represents our current state of technical knowledge and experience. However, given the multitude of possible influences affecting the processing and use of our products, this information does not exempt processors and users from running their own tests and trials. We will replace any parts that cannot be used due to defective materials. We do not replace parts for defects caused due to transport, storage or faulty installation and the consequences thereof. All information without guarantee. The ZAPPO concept