HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

Similar documents
HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

SUBMERSIBLE SEWAGE EJECTOR

SD/SW/VS50 SD50 SW50 VS50

SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

HPGR200 2 HP. Capacity-U.S. G.P.M.

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING ENVIRONMENTAL, HEALTH & SAFETY

High Light. Motors are fully submersible Pumps can handle up to ½ spherical solids Indoor and outdoor installation Easy installation and removal

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

SECTION SUBMERSIBLE GRINDER PUMPS FOR WASTEWATER (LESS THAN 10 HORSEPOWER)

Series Sump and Sewage Systems

High Light. Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation

Specifying Pumps Why Do Pumps Fail.

VSS S U B M E R S I B L E S E W A G E P U M P S

SPECIFYING PUMPS WHY DO PUMPS FAIL.

SECTION SLUDGE HOLDING TANK DECANTER PUMP

SECTION INFLUENT EQUALIZATION TANK PUMPS

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

B. Wiring Diagrams: For power, signal, and control wiring.

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

B. Pumps are to be manufactured by Flygt Pumps. No substitutes will be considered.

SECTION PACKAGE BOOSTER PUMP STATIONS

& ACCESSORIES WASTEWATERTER PUMPSUMPS -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS

Rugged, reliable and efficient sump pumps... your assurance of a dry basement!

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Replacement Wastewater Disposal System Permit Application

JDL Submersible Grinder Pumps TABLE OF CONTENTS Project: Model: Chk d: Date:

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

The following shall be incorporated into the Contract Documents dated 8 August 2018

DSC/DSCA3. EBARA Submersible Sewage Pumps Contents. Project: Model: Chk d: Date: Model

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

SUGGESTED SPECIFICATIONS

Submersible Axial Flow Propeller Pumps

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

SUBMERSIBLE PUMPS FOR WASTEWATER (S-114)

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service

SUGGESTED SPECIFICATIONS

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

SUGGESTED SPECIFICATIONS Pump Frames through 64132

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification

SEWAGE GRINDER PUMPS AND PACKAGES

MODEL 16ASX T/S - SPECIFICATION

T Series. Self-Priming Centrifugal Pumps

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

Max Head ' 1/ ' 115 1" FNPT 10' Manual On/Off Little Giant (5-MSPR) '

Stainless Steel with Poly Amide Fiber Reinforced Resin make NORUS pumps Lightweight with Exceptional Durability.

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

Project: Model: Chk d: Date: Model 32DGUII61.5S

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

SECTION SUBMERSIBLE END SUCTION PUMP

PUMPS AND ACCESSORIES. Residential Fixtures Bathing Commercial Fixtures Faucets Accessories

Sump. Sewage. Effluent. Premium SSE Pumps. An Advantage You Can Count On

Piranha Agitator Slurry Pumps.75 hp to 75 hp

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

DIVISION 15- MECHANICAL Section Fire Pumps

t y p e V S A S E W A G E P U M P

INSTALLATION INSTRUCTIONS

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

INVITATION FOR BID. April , Purchase Two Submersible Non-clog Pumps. Purchasing Depanment 4725A Moffett Road

Submersible. Issue 2 / De-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application.

SECTION 5 SUMP & SEWAGE

AN INTRODUCTION TO BRIILLER ENINGINEERING PRIVATE LIMITED, BENGALURU

Submersible drainage pump with Wide angle float switch

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302

MODELS PH PH PH

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

C o l u m n S u m p P u m p s

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

SECTION VI Duplex Lift Station with Above Grade Valve Pit

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

dp pumps The dynamics of water sewage & wastewater pumps 50 & 60 Hz

TM Series Induced Draft Cooling Tower Specifications

Pioneer Forced Draft Cooling Tower Specifications

G2S. Vertical Sump Pump

Complete Grinder Package Offering

University of Delaware

YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS

eone engineered perfectly. to do one job Environment One Low Pressure Sewer Systems

MODEL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

Transcription:

PERFORMANCE DATA Wholesale Products Page: 6570-1 RPM: 1550 Discharge: 1 ½ Solids: ½ V-A1 W-A1 D-A1 Head, meters 8 4 Head, feet 30 20 10.3 HP 0 0 Capacity, US GPM 0 10 20 30 40 50 60 liters/second 0.0 1.0 2.0 3.0 cu meters/hr 0 2 4 6 8 10 12 The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower. All pumps have a service factor of 1.2. Operation is recommended in the bounded area with operational point within the curve limit. Performance curves are based on actual tests with clear water at 70 F. and 1280 feet site elevation. Conditions of Service: GPM: TDH:

DIMENSIONAL DATA Wholesale Products Page: 6570-2 3-1/2" (89) 5-7/8" (149) 4-1/2" (114) Model Turn On Turn Off D-A1 10 (25cm) 4 (10cm) V-A1 7.875 (20cm) 3.375 (8.5cm) W-A1 9.5 (24cm) 3.5 (9cm) 3-1/2" (89) 3-1/2" (89) 1-1/2" (38) NPT DISCHARGE 7-7/8" (200) PUMP ON 10-5/8" (270) PUMP OFF 3" (76) All dimensions in inches. Metric for international use. Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purpose unless certified. Dimensions and weights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product (s) and the product (s) specifications without notice.

ELECTRICAL DATA Wholesale Products Page: 6570-3 MODEL: D/V/W-A1 Professional Series Sump Pump R.P.M. 1550 MOTOR TYPE SHADED POLE WITH THERMAL OVERLOAD, OIL FILLED MOTOR PROTECTION AUTOMATIC RESET / OVERLOAD PROTECTED HP VOLTAGE PHASE NEC CODE SERVICE FACTOR FULL LOAD AMPS 1/3 115 1-1 8.0 V-A1 W-A1 D-A1

TECHNICAL DATA Wholesale Products Page: 6570-4 MODEL: D/V/W-A1 Professional Series Sump Pump Physical Data DISCHARGE SIZE 1 ½ NPT SOLIDS SIZE ½ IMPELLER TYPE VORTEX CABLE LENGTH 10 STANDARD 20 OPTIONAL PAINT PAINTED DARK GREEN, WATER REDUCIBLE ENAMEL, ONE COAT, AIR DRIED. Temperature MAXIMUM LIQUID 140 F MAXIMUM STATOR - OIL FLASH POINT - Technical Data POWER CORD TYPE MOTOR HOUSING CASING IMPELLER MOTOR SHAFT HARDWARE O RINGS MATERIALS OF CONSTRUCTION MECHANICAL SEALS Standard: UPPER BEARING LOWER BEARING SJTW CAST IRON THERMOPLASTIC THERMOPLASTIC STEEL STAINLESS STEEL BUNA-N CARBON / CERAMIC N/A SINGLE ROW-BALL

SPECIFICATION DATA Wholesale Products Page: 6570-5 MODELS: D-A1, V-A1, and W-A1 1.01 GENERAL Contractor shall furnish all labor, materials, equipment and incidentals required to provide (Qty.) submersible centrifugal sump/effluent pump(s) as specified herein. The pump models covered in this specification are the V-A1, W-A1, and D-A1. The pump furnished for this application shall be MODEL as manufactured by Hydromatic Pumps. 2.01 DESIGN CONDITIONS Each pump shall be rated H.P., volts, phase, hertz and operate at RPM. 3.01 OPERATING CONDITIONS The pump shall deliver U.S. GPM/LPS at feet/meters TDK, and handle a inch solid. The curve submitted for approval shall state, in addition to head and capacity performance, solid handling capability, amp rating, and design impeller diameter. 4.01 CONSTRUCTION Each pump shall be of the sealed submersible type, incorporating features normally found in pumps furnished for the residential market. These features include: 1. The pump volute and motor housing shall be high quality gray cast iron, ASTM A-48, Class 30. 2. The pump shall feature a multiple strainer inlet that prevents clogging from foreign objects and provides optimum operation and reduced maintenance. 3. All external mating parts shall be machined and Buna N, O-Ring sealed. 4. All fasteners exposed to the pumped liquid shall be 300 series stainless steel. 5. All power cords shall be water resistant UL or CSA approved, with double insulation, and sized as a function of Amp. draw. 5.01 MOTOR AND SHAFT The stator, rotor and bearings shall be mounted in a sealed submersible type housing. Single phase motors shall be Shaded Pole, with automatic reset thermal overload protection. Full Load and Locked Rotor Amps as well as Run winding resistance shall be tabulated for each pump. 6.01 BEARINGS, SHAFT AND MECHANICAL SEAL A heavy duty single row ball bearing shall be required. It is permanently, continuously lubricated and cooled by the dielectric oil, which fills the motor housing. The motor shaft shall be corrosion resistant steel and sealed from the pumped liquid with a carbon ceramic mechanical seal.

SPECIFICATION DATA Wholesale Products Page: 6570-6 7.01 IMPELLER The Impeller shall be a thermoplastic, eight vane, vortex design with three pump out vanes on the back side. These vanes wash out grit and stringy material that will damage the shaft and mechanical seal. 8.01 AUTOMATIC CONTROL All pumps should be capable of automatic operation. 9.01 PRESSURE SWITCH The D-A1 Single Phase pump is furnished with a pressure diaphragm switch that is UL listed for water and sewage and GSA certified. The diaphragm switch cord shall be fitted with a piggy-back plug that allows the pump to be operated manually without removal from the sump. 10.01 FLOAT SWITCH The W-A1 Single Phase pump is supplied with a tilt-sensitive wide-angle float switch which is sealed in a non-corrosive PVC enclosure. The switch is UL listed for water and sewage and QSA certified. The float switch cord shall also be fitted with a piggy-back plug that allows the pump to be operated manually without removal from the sump. 11.01 VERTICAL MECHANICAL SWITCH The V-A1 single phase pump is furnished with a magnetic mechanical switch which is sealed in a noncorrosive PVC enclosure. The switch will be activated by a PVC float sliding up and down a non-corrosive rod. The mechanical switch cord shall also be fitted with a piggy-back plug that allows the pump to be operated manually without removal from the sump. 12.01 PAINTING All cast iron parts shall be painted before assembly with a water reducible alkyd air dried enamel. The paint shall be applied in one coat with a minimum thickness of 3 to 4 mils. 13.01 TESTING All pumps shall be individually tested to include the following: 1. The pump and power cord shall be visually inspected for imperfections, cuts or nicks. 2. The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for moisture content and/or insulation defects. 3. The motor and volute housing shall be pressurized and a 10 second air leak decay test run. 4. A specific amount of oil is now added. The pump is run in a fully automated, sequenced, control console, which monitors voltage, current and watts visually and electronically. The tester listens for any noise or malfunction. USA CANADA 293 Wright Street, DelAVAN, WI 53115 WWW.HYDROMATIC.COM 269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5 PH: 888-957-8677 ORDERS FAX: 800-426-9446 PH: 519-896-2163 ORDERS FAX: 519-896-6337 Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. 2013 Pentair Ltd. All Rights Reserved. W-01-260 (03/25/13)