ATRIA IN SHOPPING CENTRES, OFFICE BUILDINGS AND HOSPITALS. E.Ph.J. de Ruiter. Adviesbureau Peutz & Associés BV., The Hague, Holland

Similar documents
NINTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV9 CASE STUDY OF A HOSPITAL ATRIUM WITH OVERLOOKING PATIENT ROOMS

Association of Australian Acoustical Consultants Guideline for Commercial Building Acoustics. May 2011

Enhancing Acoustic Performance through the use of Window Shade Fabric White Paper

Proceedings of Meetings on Acoustics

Acoustic Performance

SELWYN PRIMARY SCHOOL, LONDON ENVIRONMENTAL NOISE SURVEY

EFA BASELINE DESIGNS ACOUSTICS STRATEGY. Acoustic Design of Schools

Stationary Noise Feasibility Assessment. 315 Chapel Street Ottawa, Ontario

GREEN H ALL m 2 CREATIVE HOUSE FOR PROGRESSIVE BUSINESS TOTAL AREA THREE BUILDINGS 480 SPACES

What is Noise? In daily life, noise means unwanted sound.

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

BAY MEADOWS PHASE II SPAR 2 SAN MATEO, CALIFORNIA

Advanced Ventilation Technologies

The design of sound insulation measures for dwellings around Amsterdam Airport Schiphol

Acoustic design of industrial spaces. The reduction of noise levels and increase of production

ACOUSTIC TREATMENT. 1 Reverberation. Inside a given internally reflective enclosure, the human ear receives:

Stationary Noise Feasibility Assessment. 315 Chapel Street Ottawa, Ontario

Work Package 2: Performance of naturally ventilated buildings

4-Acoustics: Background

SOUND ABSORBING SYSTEMS 2013

INTEGRAL BUILDING AND ENERGY DESIGN OF AN OFFICE BUILDING COMPARISON OF INITIAL DESIGN IDEAS WITH MONITORED RESULTS

Implications IN THIS ISSUE. A Newsletter by InformeDesign. A Web site for design and human behavior research.

Designing Institutions for the Future Greening Education Conference 1 st May 2013 Andrew Parkin BEng(Hons) CEng FIOA FIHEEM

21 ST CENTURY LEARNING ACOUSTICS. Steve Meszaros, M.Sc., P.Eng Acoustical Technical Director / Associate

Acoustics and Classrooms BARD MANUFACTURING COMPANY REGISTERED AIA PRESENTER VAUGHAN SMITH

ICF/Building System FSTC Test Report

Thermal bridging. Acoustic performance

Identifying impacts of amplified sound in commercial spaces below residences in mixed-use buildings

Merivale Road Residential Development 1683 Merivale Road Noise Control Study

COMPARISON OF MEASURED AND PREDICTED SOUND INSULATION FOR A THERMAL RETROFITTED BUILDING

BY: United Plastics Corporation 511 Hay Street Mount Airy, NC (800)

THE REFURBISHMENT OF THE PORTUGUESE PUBLIC SECONDARY SCHOOL NETWORK: AN ACOUSTICAL PERSPECTIVE

Elverta Park Residential Development

Aero-acoustical Facade Design Proposal

April Section 3.3. Built-up Metal Walls

Parkview Green, Beijing Microclimatic envelope

NOISE MAPPING AND NOISE ACTION PLANS IN LARGE URBAN AREAS

Noise Assessment Report

Design for Indoor Environmental Quality in schools

NOISE IN HIGH RISE BUILDINGS

Stationary Noise Assessment. Orléans Gardens. Ottawa, Ontario

A special procedure to guarantee sound isolation in dwellings

From: Tyler Adams, Mei Wu Acoustics

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls

ACOUSTIC BEHAVIOR OF ACTIVE GLAZING FAÇADES WITH CIRCULATING WATER CHAMBER

ReSound 1 & ReSound 2

Investigation of indoor climate in a naturally ventilated office building

Innovations in Acoustical Ceilings for Today's Flexible Interiors

Relationship between flanking noise through a common ceiling plenum and plenum absorption George van Hout, John Pearse and Brian Donohue

Natural Ventilation in Schools and Commercial Buildings (CPD No. 31) Issue 2 May 2017

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

BB93 Acoustics in schools Sound Insulation between spaces

Building envelop acoustic solutions. Stone wool solutions for improving Occupant comfort

Proceedings of Meetings on Acoustics

Rockfon Eclipse When design meets acoustics

OVERALL PERFORMANCE OF VENTILATED DOUBLE FAÇADES COMPARED TO A STATE OF THE ART SINGLE SKIN FAÇADE

Some Investigations on the Sound Field (Sound Propagation) Measurement in a Rectangular Room

The attached report includes:

Salem, Massachusetts

August 2008: Issue 1. Non - Residential New Build Built-up Metal Roofs

Status: Rev: Comments Date: Author: Reviewer:

Effect of implementation quadruple glazing panel into the walls on the airborne sound insulation of building facades

ENVIRONMENTAL NOISE IMPACT ASSESSMENT MCGANN 9a LANDS BANK STREET LEITRIM DEVELOPMENT AREA

ENVIRONMENTAL NOISE IMPACT ASSESSMENT THE MEADOWS IN HALF MOON BAY PHASE 5

8. Appendix F Acoustic Assessment

Kinetics Noise Control

Ozone Panel 120 Acoustic Assessment and Optimization

SOLUTION OF NOISE TRANSMISSION PROBLEMS BY IN-SITU SEGREGATION OF COMPOSITE TRANSMIS- SION FACTORS OF COMPLEX PARTITIONS USING SOUND INTENSITY

Sound solutions that don t compromise design the choice is clear with DeAmp Transparent Sound Absorber Panels

Sound Insulation of Residences and Other Buildings Exposed to Aircraft Noise

Noise Control Systems Supplement

Dennis Paoletti, FAIA; Principal

Acoustic Services Design

White Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Resistance to the passage of sound

appendix 19 acoustic insulation requirements

For all those with the ability to influence the design, layout or indoor air quality of buildings

Acoustics Size and Modes of the Small Room for Home Theatre

Acoustic ceiling. > High-duty acoustic and decoration > Acoustic adjustment > Improved sound insulation. Innovative systems High-tech materials

KINETICS NOISE CONTROL TEST REPORT #AT001032

Traffic Noise Assessment. 5 Orchard Drive. Stittsville, Ontario

Freight Rail Noise Policy and Practice

IAC Acoustics Noise-Foil Sound Absorption Panels for Industrial Applications. Dan O Brien

Corporate Environments

School Tito Maccio Plauto Cesena (IT)

EE2E045 A Calculation Method on the Energy Demand of Urban Districts

Reverberation Time Design for IM Building Addition

SECTION 4 - NOISE INTRODUCTION

Proceedings of Meetings on Acoustics

Ambient Acoustic Systems

Architectural Acoustics

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS

ENVIRONMENTAL NOISE ASSESSMENT

Mobile room acoustics for custom usage

THE ROLE OF ACOUSTICS IN THE CONTEXT OF GREEN BUILDINGS

lindab we simplify construction LindabIndoorClimateSolutions Product overview Acoustics

Accutone2 Architectural Enclosures

PILOT STUDY: HELLENIC HOTEL

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

DRAFT REPORT. Boyne East Catholic Secondary School #3CSS. Noise Impact Study. Louis St. Laurent Avenue, Milton. SACL #SW18060A0 December 11, 2018

Transcription:

ATRIA IN SHOPPING CENTRES, OFFICE BUILDINGS AND HOSPITALS E.Ph.J. de Ruiter Adviesbureau Peutz & Associés BV., The Hague, Holland 1 Introduction A growing number of buildings are being provided with large, glass-roofed spaces, often called atria. They have utilisation of daylight and a public or traffic function in common, but differ greatly in dimensions, and secondary functions. From the viewpoint of building physics, the domain of our consultancy, interesting topics are connected to the climate, both thermal and acoustical. In both fields two aspects can be distinguished: the reduction of outdoor climate to the rooms facing the atrium and the climate in the atrium itself as perceived by the occupants. Examples of the first are reduction of aircraft noise or, if the atrium has one or more glass façades as well traffic noise load at the inner façades. Other points of interest are the prevention of condensation at the glass surfaces and the use of natural ventilation and convection for controlling temperatures (and their distribution) in summer as well as in winter. The subject of this paper however is the acoustical climate in some types of atria. 2 Requirements First of all the acoustic climate must be in accordance with the visual impression of the atrium: the larger the atrium, the more spacious the room is, the more reverberation is expected and should be realised. Assuming that the dimensions of the atrium are fixed, an inventory of the functions of the atrium must be made up, which can comprise: restaurant; expositions; shopping; promenade; sporting facilities; kindergarten; musical performances; public address; receptions; etc. Next these functions have to be judged regarding sound production, interfering sound levels and the required reverberation times. Conflicts can rise between functions mutually. Because the reverberation time of large atria has a lower limit (result of the decrease in surrounding surface to volume ratio as scale increases), the required shorter reverberation times for some functions can be beyond reach. The most common problem however is controlling the sound levels caused by the occupants of an atrium.

3 Control of sound levels If the amount of sound absorption in a room and the sound power level (PWL) are known, the resulting sound level can be calculated easily. The PWL in atria can be divided in a part originating from the occupants, mostly talking people, and the basic PWL from other sources like ventilation or external noise load. The problem with the PWL of talkers is, that it tends to rise in increasing noise levels; this effect is known as the Lombard sign and makes the calculation of sound levels in atria less straight forward. This is also the reason that the sound absorption has such a central place in the next diagram, showing the governing factors and their connections. The reverberation time is added for completeness. Volume Basic PWL Reverberation time Absorption Sound level Vocal output Given the volume of the atrium and the number of occupants to be expected, the amount of sound absorption can be varied and the resulting sound level and reverberation time calculated. From these the most suitable can be chosen, yielding the proper amount of sound absorption to be added. Note however that reverberation time is not the only and rarely the major criterion. 4 Shopping centres To enhance the impression of being in a public space, a difference between the acoustical climate in an glassroofed shopping centre is desired, indicating a longer reverberation time than in the shops e.g. more than 1 s. If however a (simple) electronic public address system is installed not only for distributing background music but also for commercial messages, speech intelligibility requires an upper limit of 1.2 to 1.4 s, so the range of favourable reverberation times can be very limited. Another point is the control of sound levels caused by the occupants, occasionally in vast numbers, as shopkeepers prefer. This requires an amount of sound absorption in the range of the floor area, which is often difficult to realise. In a global way it can be concluded from the above that the height of shopping atria where commercial messages are broadcast, should be in the range of 6..8.5 m. Otherwise the height may be greater. In the newly built city of Almere, near Amsterdam, we had the opportunity to design the acoustical treatment of a glass-roofed shopping centre, which was similar in shape to a nearby existing one. The latter was not very agreeable, so after having been used as a bad example, and after the construction of the new centre, it was refurbished. Again we were invited to consult on the acoustical treatment. Picture 1 shows a section that applies to both malls. The effective height is about 15 m. The typical figures: reverberation time in the mid-frequencies and the amount of sound absorption related to floor area (A/S) are: Reverberation time T A/S Old mall 3.4 s 0.8 New mall 1.5 s 1.7 Refurbished 1.6 s 1.6 street 1.4 s - In picture 2 the reverberation times are plotted against frequency. As a comparison the reverberation time as measured in an (open) street, some 8 m wide and flanked with buildings of ca. 12 m height was added. Both the new and the refurbished shopping centre have an agreeable acoustical climate, in contrast to the old one, which was found unpleasant and noisy. The sound absorbing construction used in large quantities in both projects was perforated metal sheet with a mineral wool backing.

5 Office buildings and hospitals Although small atria occur, in many buildings large atria are found being considerably higher and/or wider than in shopping centres. A wider choice of the possible functions as stated in chapter 2 must be regarded. In the recently built Hospital of the University of Utrecht glass-roofed streets have been treated with sound absorbing baffles to reduce the reverberation time from 3.9 s to 2.8 s. The street measures 15 x 50 m and is 25 m high. The still long reverberation time does not lead to a noisy ambience: in fact the effect of reverberation is only notable when very loud sounds are produced. In picture 3 the meaning of perceived reverberation time is pointed out: as only a small portion of the decay curve is heard, the sensation of reverberation is decreased. Two identical small atria have been realised in an office building in Amsterdam, with only two functions: daylight access in the offices and "coffee corners" for the employees. A floor plan and a section are given in pictures 4 and 5. Because of architectural reasons, the amount of sound absorption had to be minimal. The basic issue being the speech transmission between the coffee corners, sound absorbing ceilings in those rooms ware sufficient. The reverberation time came out slightly under 2 s, which is rather long for an atrium of 1600 m 3, but reasonable in practice. As a last example one of the buildings in the design stage in which we are involved: the Ministry of Housing Physical Planning and Environment in The Hague. It consists of a comb-like structure with atria between the teeth of the comb. The atria are large: floor surface 21 x 21 m, height varying from 45 to 60 m. In picture 6 the floor plan shows that the atria have a glass façade as well. In this case the atria were the solution to the problem of conflicting demands: an office building with openable windows in an urban environment with high sound levels. In a both acoustical and thermal way the atria offer a meso-c1imate in which the influence of the exterior factors is reduced. The inner atrium-façades will be provided with sound absorbing parts, totalling some 1300 m 3. In these atria too, the resulting reverberation time of ca. 2.5-3 s will normally not be perceived as a very long one. As regards sound reduction, the necessity of ventilation openings in the outer façade (maximum 50 m 2 ) to control summer temperatures had to be taken into account. The ratio of this open surface to the amount of sound absorption leads to a reduction of external sound levels in the atria of ca. 15 db. With traffic noise load of 70 db(a) on some façades, the atria make it possible to open windows of rooms for ca. 10 cm without exceeding an indoor sound level of 40 db(a). The amount of sound absorption is sufficient to control the sound level of the occupants in the atria. 6 Conclusion In most cases atria have a building physical function, daylight access and smoothing of climate. It is important to provide an agreeable acoustical ambience as well. This can (only) be achieved by applying the proper amount of sound absorption in the right places. Especially when a great density of occupants is to be expected, control of the resulting sound levels by means of sound absorption is indicated. In other cases atria can play a role in reducing high ambient sound levels to moderate levels at inner façades as well. Again sound absorption is an important means in realising an adequate sound reduction. When speech intelligibility through public address systems and music (re-)production are unimportant, the reverberation time as such plays no role. It is the amount of sound absorption that has to be guarded.

Picture 1 Section of shopping centres Almere, numbers 1 to 5 are sound absorbing elements.

Picture 2 Reverberation time spectra.

Picture 3 Decay curves. At the right the level difference is small, giving less sensation of reverberation.

Picture 4 Floorplan office Amsterdam.

Picture 5 Section atrium office Amsterdam.

Picture 6 Part of the floor plan of the Ministry of HPPE in The Hague.