Energy Efficiency, Continuous Insulation and Outsulation Systems

Similar documents
En e r g y Ef f i c i e n c y, Co n t i n u o u s In s u l at i o n a n d Ou t s u l at i o n Sy s t e m s

This is what you see. DS 265

RENOVATION SOLUTIONS FROM DRYVIT

Compliance for Continuous Insulation, Water Resistive Barriers & NFPA-285 What you need to Know

Continuous Insulation and Air Barriers for High Performance Walls

RENOVATION SOLUTIONS FROM DRYVIT

THE LIFE CYCLE ADVANTAGES OF DRYVIT OUTSULATION SYSTEMS

CONTINUOUS INSULATION. Southeast Georgia Health System, Brunswick, GA

2013 COMMERCIAL PRODUCTS

EIFS Performance Beyond Code Compliance

Managing Condensation and Thermal Performance with Continuous Insulation

EXPLORE GEOMETRY AND SPACE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Professional Educational Series BSP716 USGBC # Commercial Building Science Thermal Control in Building Envelopes

NFPA 285 Compliant Wall Systems and Assemblies

BUILDING AND RENOVATING WITH DRYVIT PREFABRICATED PANELS

OUTSULATION SOLUTIONS FROM DRYVIT

EXTERIOR INSULATION FINISH SYSTEMS (EIFS)- AN EFFICIENT ENERGY SAVING METHOD. November 2009

Parex EIFS Optimum WaterMaster Optimum WaterMaster LCR Optimum Standard WaterMaster Standard WaterMaster LCR Standard

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Continuous Insulation Systems for Exterior Walls

Building Envelopes 101

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

New Opportunities For Spray Polyurethane Foam

Parex Continuous Insulation (CI)

Impact of NFPA 285 on Air Barrier Specification and Design

R-Value. Effective. Energy efficiency of masonry s thermal mass is recognized by code 9" 2" R21 + R18 THERMAL MASS +13 R13 R18

Armourwall Stucco Systems

Increase Energy Efficiency With STYROFOAM Brand CAVITYMATE Products

BELOW GRADE ASSEMBLIES AND RIGID INSULATION

ProGUARD DP The Game-changing Wall System

Continuous insulation Air tightness and Thermal mass

BENEATH THE SURFACE A Smarter Masonry

ICYNENE AND LEED NC LEED 2009 FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS

ResidentialComplete WALL SYSTEMS

Energy Efficiency. Understanding R-value, Mass Walls, Continuous Insulation and Air Tightness By Bautex Systems, LLC

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

LEED Building Design & Construction Contribution NC v4.0 (April, 2017)

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Residential Energy Code Compliance

INTRODUCING NEWBRICK. The most important innovation in the history of brick. Office Building Schenectady, NY DS277

Thermal Bridging in Residential Construction

LISTING INFORMATION OF Dryvit - Category 2 OUTSULATION NC EIFS Wall Systems SPEC ID: 29344

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

/ TABLE OF CONTENTS /

An Introduction to Spray Foam Insulation

ICC-ES Evaluation Report. ESR-3398* Reissued October 2013 This report is subject to renewal November 1, 2015.

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

Hotel Gets The Look Of Brick And Exceeds Energy Code Requirements

Energy Code Math for Commercial Walls: How polyiso continuous insulation can help

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

NOVAWRAP ASPIRE Q & A

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Innovating Continuous Exterior Insulation. Theresa A. Weston, PhD. 1

DESIGN TIPS TECHNICAL BULLETIN #53 CAST STONE AND THE LEED CERTIFICATION PROGRAM [1 of 5]

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

TECH SOLUTIONS THERMAX Insulation in Low Humidity Metal Buildings

Lightweight, insulated, energy efficient cladding changing the way we think about masonry construction.

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

R-Matte Plus-3: Insulation for the Building Envelope

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges

FOAMGLAS Insulation, Sustainable Design, and LEED

The Importance of Slab Edge & Balcony Thermal Bridges

Lightweight, insulated, energy efficient cladding changing the way we think about masonry construction.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Section 1 - Introduction 1.1 Introduction Welcome to Fox Blocks. You have made an excellent decision to use Fox Blocks Insulated Concrete Forms (ICFs)

CHANGES TO THE US ENERGY CODES COMMERCIAL & RESIDENTIAL

THE PERFECT WALL IN COLD CLIMATES:

Henry NFPA 285 Air Barrier Assemblies

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

ESR-1785* Reissued December 1, 2012 This report is subject to renewal December 1, 2014.

Insulation Retrofit Options

REPORT HOLDER: JOHNS MANVILLE TH STREET DENVER, COLORADO EVALUATION SUBJECT:

Effective Envelope Design Mitigating Risk with High Performance Panels and Acrylic Flashing Systems

Commercial Air Barrier Systems

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

Condensation - Prevention and Control

ICC-ES Evaluation Report Reissued October 1, 2010 This report is subject to re-examination in two years.

Be free to create: Polycrete, a durable choice

Welcome to this con-nuing educa-on seminar. This is the second of two parts of the High-Performance Building series.

Opportunities for BaySystems Spray Foam & Specialty Coatings to Contribute to USGBC s LEED Performance

SECTION THERMAL INSULATION

Airspace R-Values. Educational Overview. Revised 12/6/2016

Code Compliance with Insulated Concrete Form Foundations

Non-Combustible Structural Insulated Sheathing

Building Enclosure Detailing for Walls and Low-Sloped Roofs

Textured Acrylic Finishes (TAFS) Over ICFs Specifications

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

Continuous Insulation: Code Compliance and the NFPA 285 in Commercial Wall Assemblies. Hunter Panels Provider No. K169 Course Number HP 105

EE13-3 Improving Building Enclosures Thermal Performance as a Goal of Energy Efficiency. Paul E. Totten, PE Marcin Pazera, Ph. D.

LISTING INFORMATION OF Dryvit - Category 1 OUTSULATION EIFS Wall Systems SPEC ID: 29311

m^obu EXTERIOR INSULATION AND FINISH SYSTEMS STUCCO

StoTherm ci Wall Systems. Smarter from the Outside In

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Beginning of the Course

Slab edge insulation is one of

SECTION ALUMINUM WINDOWS

Transcription:

DRYVIT TECHNICAL BULLETIN Energy Efficiency, Continuous Insulation and Outsulation Systems Architects today face numerous complex challenges, including the need to design in conformance with rapidly-changing model energy codes and mandates. The International Energy Conservation Code (IECC) is the most universally adopted energy code, which outlines the requirements for use and minimum thickness for cavity and rigid continuous insulation (ci) for all wall assemblies in all climate zones. This document examines the driving forces behind new IECC Energy Code requirements and presents a practical method for meeting them in a functional, cost effective, aesthetically diverse and sustainable way. The Challenge: To cost effectively meet the latest energy code Figure 1: Outsulation Plus MD System Approved Sheathing or Substrate (not supplied by Dryvit) AquaFlash System Backstop NT Air/Water-Resistive Barrier Adhesive/Drainage Medium Drainage Strip requirements, while maintaining aesthetic diversity in both new and retrofit construction. The Solution: An Outsulation system from Dryvit (Figure 1). Exhaustively tested and proven in the field for over 40 years, Outsulation systems are engineered to seamlessly integrate all the essential components of a high performance cladding including liquid flashing, air and moisture barrier, provision for moisture drainage, continuous insulation, and durable, aesthetically diverse finish options. The entire system flashing to finish can be installed by a single contractor and is covered by a comprehensive warranty which can also include moisture drainage and sealants. Best of all, when the system is maintained under the Dryvit Platinum Expanded Polystyrene Insulation Finish Reinforcing Mesh Base Coat CARE program, the warranty can be extended for the lifetime of the building. Buildings are the #1 energy consumer and CO 2 producer According to the U.S. Department of Energy (DOE), buildings account for 39 percent of total energy use and 38 percent of total carbon dioxide (CO 2 ) emissions in the United States - divided about equally between commercial and residential structures. There are also millions of buildings built prior to 1980 which have little to no effective insulation in their exterior walls, and it is estimated by the DOE that 75% of these buildings will still be in use in 2050. These will require considerable exterior envelope maintenance - which will also present excellent opportunities to improve thermal performance. Improving the energy efficiency of all buildings will reduce consumption of non-renewable fossil fuels, lessen dependence on foreign sources of that energy, and curtail greenhouse gas emissions. Through mandates such as the EPAct of 2005 and Energy Independence and Security Act of 2007, the Federal Government has aggressively raised the bar on energy-efficiency performance requirements of government owned

buildings, and has recently taken further steps to encourage individual states to adopt the most current energy related building codes. Furthermore, all building owners, public or private, who construct or renovate with increased energy efficiency in mind reap the immediate benefit of increased property value and lower operating costs. Making walls more energy efficient Thermal bridging. A typical framed wall assembly uses wood or steel studs with some form of cavity insulation usually fiberglass batts. Although economical, this assembly is thermally inefficient because only the cavity (space between the studs) is insulated. The framing separates the insulation into non-continuous pockets and allows energy (heat) to conduct through the studs, bypassing the insulation and creating a condition called thermal bridging (Figure 2). Thermal bridging can reduce the effective efficiency of cavity insulation and steel framed wall assemblies by 50 percent or more! Concrete masonry units (CMUs) are also widely used in structural exterior mass wall construction. CMU and concrete mass walls are a highly conductive (low R-Value) materials and allows energy to flow easily through the wall. Insulating CMU and concrete mass walls generally requires adding insulation in between furring channels, which are required for cladding attachment. The furring creates repeating thermal breaks, allowing heat flow to essentially bypass the insulated portions. Eliminating thermal bridging in all building envelope assemblies can achieve significant performance improvements and thus, conserve energy. Cavity Insulation. Cavity *Source: www.energystar.gov Figure 2: Thermal Bridging Allows Heat to Flow Through Framing Warm Interior Steel framing performs even worse than wood framing insulation provides little to no thermal benefit to framing members and other discontinuities in frame wall construction, and it is also easily compressed during installation which can further reduce insulation value as well as allow excessive airflow within the cavity. Over time, this type of insulation can also settle, sag, and absorb moisture, all of which contribute to reduced thermal performance. Air Infiltration / leakage. In most buildings, some unintended air flow (leakage) occurs through insulation joints, gaps, and penetrations in the building envelope. Air can flow into or out of the building and that can greatly impact energy efficiency as well as indoor air quality. Airflow in Cold Exterior commercial structures varies widely according to building design and use, but it is estimated that air leaks are responsible for 25-40 percent of the energy used for heating and cooling a typical home.* Air barriers and continuous insulation A well designed wall assembly should seamlessly integrate an air barrier with continuous insulation (ci). (Figure 3). Placing these components on the outside face of the wall results in many benefits, including: Controlled energy flow Prevents thermal bridging, increasing thermal performance Moves dew point to outside of wall cavity, minimizing Figure 3: Exterior Continuous Insulation Minimizes Heat Flow Through Framing Warm Interior Continuous Insulation Cold Exterior 2 TECHnical BullEtin

Figure 4: Difference Between Rated R-Value (R-11) and Effective R-Value Higher number = Better performance 15 12 9 6 3 0 12.90 Outsulation Systems Whole R-Value Comparison 6.98 Brick 4.91 Stucco condensation potential and related damage Reduces thermal expansion/ contraction of framing, building movement, and associated stress Energy conservation Reduced operating costs Lower environmental impact R-Value and thermal efficiency 5.87 Glass The thermal efficiency of a material is commonly measured by its R-value. Values are assigned to insulation materials and expressed by a number (e.g., R-11) that represents the material s ability to resist thermal conductivity and the higher the R-value, the better. But it isn t quite that simple. There is a misconception in the construction community that the new energy R-11 Base Wall Cavity Insulation 7.00 Concrete 5.99 Wood Source: Oak Ridge National Laboratory (ORNL), 2002 4.66 Masonry code requirements can be met by simply increasing the R-value of the cavity insulation. Nothing could be further from the truth; continuous insulation is required in most climate zones and especially in metal framed construction. Rated vs. Effective R-Values Building scientists acknowledge that theory and practice can be widely divergent when it comes to quantifying the performance of insulation. Framed walls are typically designed and cavity insulation specified based on the insulation material s rated R-value. However, the rated R-value represents only the efficiency of the material itself and does not take into account the effects of thermal bridging. The effective R-value of the cavity insulation, when installed between the studs, drops significantly by 50 percent or more in steel framed walls and 24 percent or more in wood framed walls, because the effective R-value is based on the wall assembly as a whole not just the insulation. To demonstrate the effective R-value of cavity insulation in steel framed construction, a comparative study of rated vs. effective R-value in common wall designs was performed at the US Department of Energy s Oak Ridge National Laboratory (ORNL). Several common cladding types including a Dryvit Outsulation system, brick, stucco, and wood siding were installed over an identical stud-framed and R-11 cavity-insulated wall assembly. The study evaluated the whole wall construction, which included both the effects of thermal bridging and material / framing discontinuities, such as transition details and typical wall-accessory penetrations. (Figure 4). The test wall using a Dryvit Outsulation system (with 2-inchthick continuous insulation) was 84 percent more energy efficient than the next best performing cladding brick veneer. The difference between the rated R-value of the wall cavity insulation (R-11) and the effective R-value of the brick veneer wall Cavity insulation alone allows thermal bridging (left). Adding exterior continuous insulation prevents heat flow through framing (right). Before Continuous Insulation After Continuous Insulation Photos courtesy of The Dow Chemical Company *Source: www.energystar.gov 3 TECHnical BullEtin

assembly (R-6.98) is a direct result of thermal bridging and material / framing discontinuities. The study clearly demonstrates the negative impact of thermal bridging in wall assemblies which have only cavity insulation, and conversely, the significantly positive effects when continuous insulation is utilized. A second illustrative example comes directly from the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) Design Standard 90.1, which is the driving force behind the model energy codes. ASHRAE Standard 90.1 specifically outlines effective R-value performance for insulation materials (e.g., cavity and/or continuous insulation), applies to all commercial buildings through its adoption into the IECC. Most specifically, the ASHRAE Standard 90.1-2010, as a result of previously mentioned government mandates, has been established by the Department of Energy (DOE) as the minimum energy code design guideline which all states are required to adopt by October 18, 2013. For Commercial Construction, Table 1 from the ASHRAE Standard 90.1 shows that when used in steel frame construction (16 OC), an R-13 rated cavity insulation will only provide an effective R-value of 6.0 a reduction of 54 percent! Furthermore, a rated increase from R-13 to R-19 (thicker cavity insulation) requires the stud depth be increased to a more costly 6 inches, and would only yield an effective insulation increase of R-1.1 - only 20 percent of the perceived increase. Even more shocking is that an R-25 rated cavity insulation requiring 8 inch Figure 5: U.S. Climate Zones (per IECC) framing - has only an effective R-value of 7.8 a 68.8 percent reduction in the effective resistance and energy-efficiency performance. Deciphering Model Energy Codes IECC. As part of the International Building Code (IBC), the International Energy Conservation Code (IECC) is the guiding force for building design and material requirements related to energy efficiency. As previously mentioned, the IECC bases its guidelines on and adopts the ASHRAE Standard 90.1. Several different versions (2003, 2006, 2009 and 2012) of the IECC are currently adopted across the country, thus an architect must be aware of which version has been adopted by the state or local jurisdiction in which the project is located. To determine the current version in use by a particular state, visit http://www.iccsafe.org/ gr/pages/adoptions.aspx. The IECC divides the United States into eight climate zones and establishes minimum requirements for the placement, and amount of insulating materials cavity and Table 1: Effective Insulation/Framing Layer R-Values for Wall Insulation Installed Between Steel Framing in Commercial Buildings Nominal Depth of Cavity, in. Actual Depth of Cavity, in. Rated R-Value of Airspace or Insulation Effective Framing/Cavity R-Value At 16 in. on Center At 24 in. on Center Empty Cavity, No Insulation 4 3.5 0.91 0.79 0.91 Insulated Cavity 4 3.5 11 5.5 6.6 4 3.5 13 6.0 7.2 4 3.5 15 6.4 7.8 6 6.0 19 7.1 8.6 6 6.0 21 7.4 9.0 8 8.0 25 7.8 9.6 Source: ASHRAE 90.1 Table A9.2B 4 TECHnical BullEtin

Table 2: Prescriptive R-value Requirements Commercial Framed Construction Climate Zone 1 2 3 Steel framed R-13 R-13 continuous - in the wall assembly (Figure 5). At present, the most widely used IECC version is the 2009 with a number of states now beginning to adopt 2012. Both the IECC 2009 and 2012 through their adoption of ASHRAE Standard 90.1 as a minimum guideline, require continuous insulation for steel-framed wall assemblies in climate zones 3-8 for all commercial constructions. However, the IECC 2012 /ASHRAE Standard 90.1-2010 goes even further by separating out Commercial Use Group-R (overnight occupancies) by adding a requirement for continuous insulation in climate zone 2 and increasing the requirement for continuous insulation in climate zones 3, 7 and 8 (Table 2). Furthermore, IECC 2012 can now actually stand alone as its own energy code and includes even further increased requirements for continuous insulation (CI) in all climate zones and air barrier performance/building air leakage testing criteria. This now leaves 4 except Marine Commercial Construction R-3.8 CI Wood framed and other R-13 R-13 R-13 R-13 Steel framed R-13 5 and Marine 4 R-3.8 CI 6 7 8 Commercial Construction - Use Group R (Overnight Occupancies) Red values reflect increased CI requirements Wood framed and other R-13 R-13 R-13 Source: ASHRAE Standard 90.1-2010 Table 3: R-Value Prescriptive Requirements - Commercial Mass Wall Construction Climate Zone 1 2 3 R-3.8 CI 4 except Marine Commercial Construction 5 and Marine 4 R-15.6 CI R-15.6 CI R-18.8 CI R-15.6 CI 6 7 8 Mass Wall R-Value NR R-5.7 CI R-7.6 CI R-9.5 CI R-11.4 CI R-13.3 CI R-15.2 CI R-25.0 CI Source: ASHRAE Standard 90.1-2010 architects and engineers a decision as to which energy code guideline - IECC 2012 or ASHRAE Standard 90.1-2010 - they wish to use for a commercial project. The IECC permits two methods prescriptive and performance - which may be used to determine the amount of necessary insulation for wall design. The prescriptive method relies singularly on the rated R-value of an insulation material and identifies predetermined insulation requirements for various wall types and climate zones. For example, the IECC establishes minimum prescriptive R-values as previously mentioned for cavity and exterior continuous insulation for framed wall construction (Table 2) but also for continuous insulation for mass wall construction (Table 3) based on each climate zone. No further analysis or calculations are required. The performance method is slightly more complicated. It is based on U-factor (which is figured as the fractional inverse of R-value ie R-13 = a U-factor of 1/13, expressed by the decimal.0769) and accounts for all of the wall assembly components analyzed together in order to meet the climate zone s thermal performance requirement. It is important to understand that both the prescriptive and performance paths generally have the same requirements for cavity and continuous insulation. Though different approaches, they have the same conclusions. Mandates, Design Standards, and Codes In light of the federal government s stated goal of improving the energy efficiency of buildings (new and existing) and specifically the initiatives set forth by the 2009 American Recovery and Reinvestment Act s State Energy Program and the DOE s mandate that all states must comply with ASHRAE Standard 90.1 2010 no later than October 2013 future codes are expected to be more stringent from an energy efficiency standpoint. As states adopt the newer energy codes, the changes reflected therein will be more dramatic in some areas than in others, resulting in major changes to thermal efficiency requirements. Get on the Right Path To determine the required prescriptive path for a particular project: 1. Identify the project s location by state. 2. Determine current IECC requirements for that state www. iccsafe.org/gr/pages/adoptions. aspx. 3. Identify climate zone for project (Figure 5, Page 4). 4. Refer to Tables 2 and 3 (Page 5) to determine minimum prescriptive continuous insulation requirements. 5 TECHnical BullEtin

Figure 6: Total Carbon Footprint of Cladding Types Lower number = Better performance 10,000 8,000 6,000 4,000 2,000 0 Total Carbon Footprint Carbon Dioxide Emissions (Grams of CO 2 /Unit) 1686 Outsulation Systems 8303 Brick 4906 Stucco Source: National Institute of Standards and Technology (NIST, BEES v4.0 analysis, 2007) As part of their focus on sustainable construction, it is highly likely that future building codes will continue to increase the requirements for thermal efficiency as well as the use and thickness of continuous insulation (ci). Outsulation Systems by Dryvit a single source solution to a complex problem Able to satisfy the often divergent building design requirements of form, function, budget, and regulatory compliance, Outsulation Systems by Dryvit are the ideal solution for meeting model energy code requirements for increased thermal efficiency in exterior walls. These systems are unique in their ability to provide an air and waterresistive barrier, continuous insulation (ci) AND durable, aesthetically diverse finish options in a fully engineered, tested and proven system. They are equally well suited to new construction or renovation and perhaps most importantly, they pass the NFPA 285 fire test which is required for all framed wall construction that incorporates exterior continuous insulation, i.e. foam plastic. 4973 Aluminum 3997 Cedar Siding 4581 Vinyl Key Benefits of using Dryvit Outsulation systems: Lower Construction Cost Outsulation Systems weigh considerably less than most other cladding systems such as brick and stucco, which translates into a reduction in foundation and structural framing costs and a shortened construction cycle. Maximizing thermal efficiency also allows for a smaller, less costly HVAC system. To view a comprehensive case study, go to www. dryvit.com/mca. Lower Operating Cost Improved energy efficiency translates to less energy required to heat and cool the building for its lifetime. Lower Environmental Impact The National Institute of Standards and Technology (NIST) conducted a 50-year Life Cycle Analysis (LCA) (Figure 6) which concludes that an Outsulation System by Dryvit has an overall carbon footprint that is nearly five times smaller than clay brick veneer and nearly three times smaller than conventional stucco and the other tested claddings. Contributes to LEED Certification An Outsulation System by Dryvit can potentially assist in the contribution of as many as 37 points toward a building s LEED Certification (v3, 2009) through Credit Category areas such as Materials Resources (MR) for the Building Reuse, Construction Waste Management, Recycled Materials and Regional Materials credits; Indoor Environmental Quality (IEQ) for the Thermal Comfort & Design credit; Innovation in Design (ID); and, Energy and Atmosphere (EA). Most specifically, through the Energy and Atmosphere, Credit 1 - Optimized Energy Performance, Option 1 - Whole Building Energy Simulation, as many as 19 LEED Points can be earned for New Construction (NC) and Schools and as many as 21 LEED Points can be earned for Core & Shell (CS) type projects by demonstrating percentage (%) improvements to the building s overall energy performance when compared to the applicable building code as a baseline (Table 4). Table 4: Outsulation Systems - Potential Contribution to LEED V 3.0 Materials and Resources NC Schools C&S Credit 1.1 Building Reuse 1-3 1-2 1-5 Credit 2 Construction Waste Management 1-2 1-2 1-2 Credit 4 Recycled Content 1-2 1-2 1-2 Credit 5 Regional Materials 1-2 1-2 1-2 Indoor Environmental Quality (IEQ) Credit 7.1 Thermal Comfort: Design 1 1 1 Innovation In Design (ID) Credit 1 Innovation in Design 1-5 1-4 1-5 Energy and Atmosphere (EA) Credit 1 Optimized Energy Performance 1-19 1-19 3-21 Total 7-33 7-31 9-37 6 TECHnical BullEtin

Figure 7: Dryvit s Wide Array of Acrylic-based Finishes Custom Brick TM Lymestone TM TerraNeo Quarzputz Sandpebble Fine HDP TM Finish Reflectit TM Architectural Diversity The continuous insulation (ci) component of Outsulation Systems by Dyvit can be shaped, cut, and grooved to create multiple and diverse architectural styles. Using the latest in acrylic copolymer, UV resistant and hydrophobic chemistry, a Dryvit finish (Figure 7) can provide a variety of high performance characteristics with the appearance of stucco, limestone, granite, brick, and metal. Single-Source Supply Installation and Warranty Dryvit Systems, Inc. provides all components of the Outsulation System from flashing to finish - providing the architect a fully engineered, integrated and warranted cladding system. In addition, the Outsulation System components are installed by a single sub-contractor, allowing the general contractor to more easily coordinate the installation. Finally, through the DryvitCARE? Platinum program, the building owner is eligible for a transferable, renewable warranty which can ensure maximum performance and peace of mind for the lifetime of the building. Continuous Insulation (ci) Options In addition to expanded polystyrene (EPS) insulation, Dryvit Systems has partnered with DOW Building Solutions and now offers extruded polystyrene (XPS) as the insulation component of the Outsulation? XTM system. Advantages of DOW s XPS include a 50 year thermal performance warranty on the insulation board, higher R-value and increased impact resistance / durability (Figure 8). Figure 8: Dryvit s Outsulation X System AquaFlash Flashing System Approved Sheathing or Substrate (not supplied by Dryvit) DOW TM XNERGY TM Rigid Insulation Finish Air/Water-Resistive Barrier Adhesive/ Drainage Medium Base Coat Mechanical Fastener with Washer Reinforcing Mesh Drainage Strip 7 TECHnical BullEtin

Summary Comprehensive changes have taken place in the building codes, and none are more important than those associated with increasing the energy efficiency of the building envelope. The need for improved energy performance, reduced energy consumption and lower environmental impact is dramatically affecting the way architects, contractors and building owners design, build and maintain new and existing structures, and as the requirements for the use of continuous insulation (ci) in all high performance wall assemblies become universal, it will become increasingly clear that an Outsulation System by Dryvit is an exceptional, long term solution. Resources ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers): www.ashrae.org Building Science Corporation: www.buildingscience.com ICC (International Code Council): www.iccsafe.org/pages/default.aspx IECC (International Energy Conservation Code): www.energycodes.gov IgCC (International Green Construction Code): www.iccsafe.org/cs/igcc/pages/default.aspx LEED (Leadership in Energy and Environmental Design): www.usgbc.org/leed McKinsey Quarterly: www.mckinseyquarterly.com/a_cost_curve_for_greenhouse_gas_reduction_1911 National Institute of Building Sciences: www.nibs.org NIST (National Institute of Standards and Technology): www.nist.gov/public_affairs/nandyou.cfm USDOE (U.S. Department of Energy): www.energycodes.gov USGBC (U.S. Green Building Council): www.usgbc.org Dryvit Systems, Inc. One Energy Way West Warwick, RI 02893 800-556-7752 401-822-4100 www.dryvit.com Dryvit Systems, Inc., 2012 Printed in U.S.A. DS751 DOW XNERGY are trademarks of The Dow Chemical Company Information contained in this technical bulletin conforms to the standard detail recommendations and specifications for the installation of Dryvit Systems, Inc. products as of the date of the publication of this document and is presented in good faith. Dryvit Systems, Inc. assumes no liability, expressed or implied, as to the architecture, engineering or workmanship of any project. To ensure that you are using the latest, most complete information, contact Dryvit Systems, Inc.