VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases

Similar documents
Sabah Shawkat Cabinet of Structural Engineering 2017

CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES 9.2 TYPES OF STAIR CASES

DESIGN AND DETAILING OF RETAINING WALLS

VALLIAMMAI ENGINEERING COLLEGE KATTANKULATHUR ST7014-INDUSTRIAL STRUCTURES QUESTION BANK

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

6. Design of Portal Frames (For class held on 20 th, 26 th and 27 th March 07)

UNIT-1 RETAINING WALLS

UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions)

CE2401-DESIGN OF REINFORCED CONCRETE AND BRICK MASONRY QUESTION BANK

COVENANT UNIVERSITY ALPHA SEMESTER TUTORIAL KIT (VOL. 2) 400 LEVEL

CIVIL ENGINEERING YEAR QUESTION BANK

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Lecture Retaining Wall Week 12

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

Flat Slabs. d 2. A typical flat slab (without drop and column head)

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

Effect of U-Turn in Reinforced Concrete Dog-Legged Stair Slabs

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE) UNIT-5 FOOTINGS & STAIRS

Flexure and Serviceability Limit State

Seismic Behaviour of RC Shear Walls

KSK COLLEGE OF ENGINEERING AND TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING CE 2505-DESIGN OF RC ELEMENTS QUESTION BANK

Why do we need to learn about Stairs

DESIGN OF RC ELEMENTS UNIT 1 PART-A

Analysis and Design of One-way Slab System (Part-I)

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for

> 0. 1 f, they are treated as beam-columns.

COLUMNS. Classification of columns:

CE2306 DESIGN OF RC ELEMENTS UNIT II LIMIT STATE DESIGN FOR FLEXTURE Part A (2marks) 1. Explain the check for deflection control in the design of

VARIOUS TYPES OF SLABS

Questions with Solution

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

DHANALAKSHMI COLLEGE OF ENGINEERING, CHENNAI DEPARTMENT OF CIVIL ENGINEERING CE6601 DESIGN OF REINFORCED CONCRETE AND BRICK MASONRY STRUCTURES

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE)

Slabs and Flat Slabs

Seismic Detailing of RC Structures (IS: )

Keywords: Bunkers, length to breadth ratio, lateral dimensions, bituminous coal, total cost, most economical.

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

Two-way slabs. Flat plate with or without drop panels / capitals

Types of Staircases Figures. Figures a to e present some of the common types of staircases based on geometrical configurations:

CHAPTER 2. Design Formulae for Bending

Analysis, Design and Estimation of Multi Storied Residential Building using ETABS Software

1 Prepared By:Mr.A.Sathiyamoorthy, M.E., AP/Civil

Proposed Revisions to Part 2, Sections 2.13 to Draft DEVELOPMENT AND SPLICES OF REINFORCEMENT SECTION 2.13 DEVELOPMENT REQUIREMENTS

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

GATE SOLVED PAPER - CE

Level 6 Graduate Diploma in Engineering Structural analysis

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

6. Design of Water Tanks (For class held on 23 rd, 24 th, 30 th April 7 th and 8 th May 07)

Analysis and Design of High-Rise RC Structure in Different Seismic Zones

3. Bond, Anchorage and Shear This chapter will discuss the following topics:

Design for Shear for Prestressed Concrete Beam

3.4.2 DESIGN CONSIDERATIONS

GUJARAT TECHNOLOGICAL UNIVERSITY, AHMEDABAD, GUJARAT COURSE CURRICULUM COURSE TITLE: DESIGN OF REINFORCED CONCRETE STRUCTURES (COURSE CODE: )

REINFORCED CONCRETE STRUCTURE COURSE STR 302A CL0SED BOOK EXAM THIRD YEAR CIVIL FIRST TERM YEAR TYPES OF SLABS

Chapter Five Torsion. Reinforced Concrete Structures 2 (CEng-3122)

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

CHAPTER 10: GENERAL STRUCTURAL DETAILS

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

Analysis and Design of G+3 Residential Building using STRUDS

COST ANALYSIS OF DOME STRUCTURE WITH RING BEAM

ST7008 PRESTRESSED CONCRETE

OXFORD ENGINEERING COLLEGE (NAAC Accredited with B Grade) Department of Civil Engineering LIST OF QUESTIONS

Schöck Isokorb Type CM

Influence of Depth in Single Cell & Twin Cell Box Girder

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

DESIGN OF WALLS FOR SHEAR

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

DESIGN OF MULTILEVEL CAR PARKING BUILDING

Analysis and Design of a Commercial cum Residential Building By Using STAAD Pro

Design of Reinforced Concrete Slabs

ANALYSIS AND DESIGN OF RESIDENTIAL BUILDING BY USING SAP-2000

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Masonry and Cold-Formed Steel Requirements

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Schöck Isokorb type K-HV, K-BH, K-WO, K-WU

VALLIAMMAI ENGINEERING COLLEGE

Parametric study on the shear strength of concrete deep beam using ANSYS

ASSIGNMENT 1 ANALYSIS OF PRESTRESS AND BENDING STRESS BFS 40303

ANALYSIS AND DESIGN OF MULTI - STOREY BUILDING UNDER LOAD COMBINATION

HILTI HY 150 REBAR DESIGN GUIDE

Chapter. Masonry Design

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

5.4 Analysis for Torsion

UNIT III Earthwork Estimation & Reinforcement Estimation

Schöck Isokorb type DXT

How Loads Are Distributed

Comparative Study of R.C.C and Steel Concrete Composite Structures

Contents. Foreword 1 Introduction 1

Multideck 146. Contents

Application nr. 6 (Connections) Strength of welded connections to EN (Eurocode 3, Part 1.8)

Alternate Design Method- Design Procedure of Two-way Slabs using ACI Moment Coefficients and Approved by BNBC 2013

Design and Estimation of Reinforced Building: A Case Study

Schöck Isokorb Type CV

DUCTILITY REQUIREMENTS FOR BUILDINGS

Comparison of One-way and Two-way slab behavior. One-way slabs carry load in one direction. Two-way slabs carry load in two directions.

DECK DAMAGE AND PENETRATIONS

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED

Lysaght Bondek. Structural steel decking system Design and Construction Manual

FOUNDATION ENGINEERING UNIT III FOOTINGS AND RAFTS

Transcription:

VTU EDUSAT PROGRAMME 17 2012 Lecture Notes on Design of Stair cases DESIGN OF RCC STRUCTURAL ELEMENTS - 10CV52 (PART B, UNIT 8) Dr. M. C. Nataraja Professor, Civil Engineering Department, Sri Jayachamarajendra College of Engineering, Mysore - 570 006 E mail : nataraja96@yahoo.com

DESIGN OF STAIR CASES Syllabus UNIT 8 General features, types of stair case, loads on stair cases, effective span as per IS code provisions, distribution of loading on stairs, Design of stair cases with waist slabs. Stairs Stairs consist of steps arranged in a series for purpose of giving access to different floors of a building. Since a stair is often the only means of communication between the various floors of a building, the location of the stair requires good and careful consideration. In a residential house, the staircase may be provided near the main entrance. In a public building, the stairs must be from the main entrance itself and located centrally, to provide quick accessibility to the principal apartments. All staircases should be adequately lighted and properly ventilated. The staircase is an important component of a building, and often the only means of access between the various floors in the building. It consists of a flight of steps, usually with one or more intermediate landings provided between the floor levels. The horizontal top portion of a step is termed tread and the vertical projection of the step is called riser. Generally tread of 300 mm and Riser of 150 mm are ideally suited for public buildings. For residential and factory buildings lower values of tread up to 250 mm combined with higher values of riser up to 190 mm are preferred. The width of the stair is generally around 1.1 1.5m, and in any case, should normally not be less than 850 mm. The horizontal projection (plan) of an inclined flight of steps, between the first and last risers, is termed going of flight. Generally, risers in a flight should not exceed about 12 in number. Types of stair cases Geometric classification 1. straight stairs (with or without intermediate landing) 2. quarter-turn stairs 3. dog-legged stairs 4. open well stairs 5. spiral stairs 6. helicoidal stairs 7. slabless stair case 8. free standing stair case

Structural Classification 1. Stairs with cantilever steps 2. Stair slab spanning transversely (or horizontally between stringer beams or walls) 3. Stair slab spanning longitudinally 4. Slabless or raiser and tread type 5. Spiral stair case 6. Helicoidal slab stair case 7. 3D or free standing stair slab Classification based on span Based on type of span, following are the two types of stair cases; Horizontally spanning or transversely spanning stairs. Figure 1 Longitudinally spanning stairs. For details refer IS: 456-2000 and SP (34). Transversely spanning stair cases can be seen in figure 1. Here the main steel is provided transversely and the distribution steel is in the longitudinal direction. STEPS STRINGER BEAMS STRINGER BEAM 0.1L-0.15L 0.5 A st A st L

Figure 1. Transversely spanning stair cases Longitudinally spanning stair cases: Here the main steel in provided longitudinally and the distribution steel is in the transverse direction. Refer problem. Effective span The effective span is defined as follows based on the type of support. Where flight supported at the ends of the landings in such a way that both landing and flight spans in the same direction, the effective span is the distance between the center to center of the supporting beams or wall. Refer Figure 2. Where spanning on the edge of a landing slab which spans parallel with the riser, the effective span is the distance equal to the going of the stairs plus at each end either half the width of the landing or one meter, whichever is smaller. Refer Figure 3. Where supported at top and bottom riser by beams spanning parallel with the riser, the distance center to center of the beams is the effective span. Refer Figure 4. L e

Figure 2. Flight supported at the ends of the landings on walls X X Y Y L e Figure 3. Flight supported at the sides of the landings on walls L e Figure 4. Flight supported on landing beams

Guide lines Guide lines to be followed for fixing the dimensions of component parts of stair. 1. Rise (R) is 150mm to 180mm and tread (T) is 220 mm to 250 mm for a residential building. 2. For public building rise is kept between 120 to 150 mm and tread between 250 to 300 mm 3. Sum of tread (T) and twice the rise (2R) should be between 500 mm to 650 mm 4. The width of the stair is dependent on the usage and is between 0.8 m to 1 m for residential building and 1.8 m to 2 m for public building. 5. The width of the landing is equal to the width of stairs. 6. The number of steps in each flight should not be greater than 12 7. The pitch of the stair should not be more than 38 degrees. 8. The head room measured vertically above any step or below the mid landing shall not be less than 2.1 m. Distribution of Loading on Stairs In the case of stairs with open wells, where spans partly crossing at right angles occur, the load on areas common to any two such spans may be taken as one half in each direction as shown in Fig. 5. Where flights or landings are embedded into walls for a length of not less than 110 mm and are designed to span in the direction of the flight, a 150 mm strip may be deducted from the loaded area and the effective breadth of the section increased by 75 mm for purposes of design (see Fig. 6). Depth of Section The depth of section shall be taken as the minimum thickness perpendicular to the soffit of the staircase.

βl1, (1-2β )L1

RCC design of a Dog-legged staircase In this type of staircase, the succeeding flights rise in opposite directions. The two flights in plan are not separated by a well. A landing is provided corresponding to the level at which the direction of the flight changes. Design of Dog-legged Stairs Based on the direction along which a stair slab span, the stairs maybe classified into the following two types. 1. Stairs spanning horizontally 2. Stairs spanning vertically Stairs spanning horizontally These stairs are supported at each side by walls. Stringer beams or at one side by wall or at the other side by a beam.

Loads Dead load of a step = ½ x T x R x 25 Dead load of waist slab = b x t x 25 Live load = LL (KN/m 2 ) Floor finish = assume 0.5 kn/m Stairs spanning Longitudinally In this, stairs spanning longitudinally, the beam is supported ay top and at the bottom of flights. Loads Self weight of a step = 1 x R/2 x 25 Self weight of waist slab = 1 x t x 25 Self weight of plan = 1 x t x 25[(R 2 + T 2 )/T] Live load = LL (KN/m 2 ) Floor finish = assume 0.5 KN/m For the efficient design of an RCC stair, we have to first analyse the various loads to be imposed on the stair. The load calculations will help us determine, how much strength is required to carry the load. The strength bearing capacity of a staircase is determined on the amount of steel and concrete used. The ratio of steel to concrete has to be as per standards. Steel in the staircase will take the tension imposed on it and the concrete takes up the compression

Design of RCC Stair case Ex. 1 Design a dog legged stair case for a residential building hall measuring 2.2 m x 4.7 m. The width of the landing is 1m. The distance between floor to floor is 3.3 m. The rise and tread may be taken as 150mm and 270mm respectively. The weight of floor finish is 1 kn/m 2. The materials used are M20 grade concrete and Fe415 grade steel. Sketch the details of steel. Here flight and the landing slabs spans in the same direction i.e, Flight spans longitudinally. Data: f ck = 20 MPa, f y = 415MPa, Landing = 1m, H = 3.3m, Size of stair case hall = 2.2m x 3.7 m. Assume the wall thickness as 200 mm. Proportioning of stair: R = 150 mm, T= 270 mm. H = 3.3m. Height of each flight = H1= H/2 =3.3 /2 = 1.65m Number of risers in each flight = H1/R = 1650 /150 = 11. Thus Number of steps = 11-1 =10 Width of flight horizontally = 10 x 270 = 2700mm Width of hall = 4700mm. Thus the each landing width = 1m Let the width of step = 1m. Gap between the flights = 0.2 m To fix the depth of waist slab: l/d = 26, assuming partial fixity l e = 4700 + 200 = 4900 mm. d= 4900/26= 188mm. Assume effective cover = 20 mm NC ( mild exposure) + 10/2 = 25 mm, D= d + d e = 213 mm say 215mm. Thus, d= 190mm Calculation of loads: Tanθ = R/T = 0.56. Hypotenuse, h = 309mm. Cosθ = T/h= 270/309= 0.874 Deal load of waist slab in plan = (0.215x1x1x25) 1/Cosθ = 6.14 kn/m 2 Weight of all floor finish horizontally, assumed as = 1kN/m 2 Weight of steps = R/2 x1 x1 x 24 = 1.80 kn/m 2 Imposed load = 3 kn/m 2 Total load = w = 11.94 kn/m 2 Ultimate load= 1.5x11.94 = w u = 17.91 kn/m 2 Design of second flight: Factored bending moment for second flight taking partial fixity effect BM = w u l 2 /10 = 17.91 x 4.9 2 /10 = 43.0 knm M u, lim of the given waist slab as balanced section = Qbd 2 = 2.76 x 1000 x 190 2 =99.63 knm> 43kNm. Under reinforced section. The depth provided is ok. T θ h R

To find area of steel: Main steel By calculation (Use this approach in exam) For URS, Area of steel: M u = 0.87 f y A st (d f y A st /f ck b) = 43x10 6 68599A st 7.49 A 2 st = 43 x 10 6. Thus, 7.49 A 2 st - 68599A st + 43 x 10 6 = 0 Solving A st = 676 mm 2, p = 100A st /bd = 0.356% < p t, lim = 0.96%, URS Provide 10 mm @ s= 78.6/676 x 1000 =116.2, say 110mm c/c. Provide #10@110. Here spacing is <300mm, <3d. Thus ok from serviceability requirements for cracking. Use of SP 16 flexure table M u /bd 2 = 43x10 6 /1000 x 190x 190 = 1.191. From SP-16,Table 2, page 48, p =0.359%, p t, lim = 0.96% A st = 0.359 x 1000 x 190/100 = 682 mm 2. Provide #10@110. Use of SP 16 design table for slabs Also from SP-16, Table 23, page 64 for slab design, for a moment of 43 knm, the steel can be obtained directly for M20, f y =415 and D=225 mm as #10@120. As D = 215mm, provide #10@110. A st = 79/110x1000 = 718 mm 2, p = 100A st /bd = 0.38% Use of SP 16 design charts for slabs and beams: Chart 13, page 33 for M20, Fe415, d=190mm, Mu =43 knm, percentage of steel p = 0.355%. Provide #10@110. These tables are valid for flexure members having 50mm to 800 mm depth which covers both slabs and beams. Distribution steel: Area of steel = 0.12% of A g = 0.12 bd/100 = 0.12 x 1000 x 215/100 = 258 mm 2. Provide #8@ 50/258 x1000 = 190 mm c/c. The spacing is less than 450mm and also 5d. Thus safe in cracking. Design for shear: V u = w u l e /2 = 17.91 x 4.9/2 = 43.88 kn. τ v = V u /bd= 43.88 x1000/(1000x190) = 0.23MPa P t =0.35%, From IS:456-2000, τ c, slab = k s τ v =1.18 x 0.41. Thus, τ v < k s τ c < τ c, max. ok Hence the slab is safe in shear. Check for development length: Provide enough development length at the junction of flight and landing and also necessary anchorage over the support as shown in figure. L d = 47φ =470 mm and l d /3 =160mm. Check for deflection: As the effective depth provided is more than that required for controlling the deflection, the slab is safe in shear. (L e /d) available < (l/d) basic value x k 1 k 2 k 3. 4700/190 = 24.7 <

26x1x1.3x1. ok. Here k 2 is 1.3 from IS:456-2000, Fig. 4, page 38, for p=0.35% and f s = 240MPa of Fe415 steel. Check for cracking: As the detailing requirements with regard to diameter, spacing for main and dist. steel and cover for slab are satisfied as per the requirements of IS:456-2000, the cracking is prevented indirectly. Thus slab is safe in serviceability requirements. Detailing: As shown in figure 1. Design of First flight which starts from foundation The same steel can be provided for first flight also. However the effective span for this flight is less (l e = 3.9 m) and hence the steel required is also less. Thus, ground flight is safe in shear, deflection and cracking as well. If the support conditions are different, then the effective span will be different. All other design calculations remain same. In this problem, if the flight is supported at its ends by means of landing slab (i.e. at the junction of flight and landing), then l e = 2700 mm (distance b/n first and last risers) for both flights. Here the flight and the landing spans in opposite directions. Flight spans longitudinally and landing spans transversely). Landing is to be designed separately depending on its edge conditions. Similarly for the other support condition, i.e. when the flight is supported at all edges of the landing, then l e = l g +x +y as per IS;456-2000.

L d =470mm FLOOR LEVEL REINFORCEMENT FROM BM T= 270 R=150 LAP LENGTH ROW OF CHAIRS LANDING FIRST FLIGHT L d =470mm Wall D=215 mm FOUNDATION MAIN STEEL # 10 @ 110 150 DIST. STEEL # 8 @ 190 GL 500 mm GROUND FLIGHT 500 mm 1000 mm 2700 mm 1000mm 200 mm 1000 mm 200 mm 2200 mm 1000 mm 200 mm L e = 4900 mm PLAN Figure 1. Detailing for stair case when supported at the ends on landing on walls. Ex.1

Y=0.3 l or L d X = 0.15 l or L d DS l Y X LANDING BEAM Y MAIN STEEL LANDING BEAM 150 INTERMEDIATE LANDING FIRST FLIGHT ROW OF CHAIRS MAIN STEEL # 12 @ 120 DIST. STEEL # 8 @ 150 150 GL GROUND FLIGHT FOOTING 150 500 500 L e PLAN Figure 2. Detailing for stair case when supported on landing beams.