Secondary Loop System for Automotiv HVAC Units Under Different Climatic Conditions

Similar documents
LCCP Analysis of Energy-Saving Effect of Defaulting to Recirculated Cabin Air in EV Mobile Air Conditioning System

The Benefit of Variable-Speed Turbine Operation for Low Temperature Thermal Energy Power Recovery

Application of Near-Optimal Tower Control and Free Cooling on the Condenser Water Side for Optimization of Central Cooling Systems

Using Simulation Model to Reduce System Design Time and Cost

Fundamental Investigation Of Whole-Life Power Plant Performance For Enhanced Geothermal Systems

Research on Ground Source Heat Pump Design

Thermally operated mobile air-conditioning system

Figure 1: Uncovered and covered PVT collectors

Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis

The Part-Load Efficiency Benefit of Oil-Free, High- Speed, Direct-Drive Centrifugal Compressors

Performance Mapping for Variable Ductless Heat Pump Systems in Heating, Cooling and Defrost Operation

Study on Ejector - Vapor Compression Hybrid Air Conditioning System Using Solar Energy

Development of a small capacity directly air-cooled water/libr absorption chiller

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

Experimental Investigation of a Hermetic Scroll Expander-Generator

Challenges in Thermal Management

COP Improvement Of A CO2 Refrigeration System With An Expander-Compressor-Unit (ECU) In Subcritical And Transcritical Operation

Component development and first test results of a directly air-cooled water/libr absorption chiller

Australian Solar Cooling Interest Group (ausscig) Conference

A Simplified Thermal Model for a CO2 Compressor

Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders

Experimental Study of a CO2 Thermal Battery for Simultaneous Cooling and Heating Applications

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

Opportunities and Limitations of Building Precooling

Heat Pump With a Condenser Including Solid- Liquid Phase Change Material

Performance Evaluation under the Actual Operation Condition of a Ground Source Multiheat Pump System

RESEARCH ON INTEGRATION OF VAPOR CYCLE/LIQUID-COOLED REFRIGERATION SYSTEM FOR HELICOPTERS

COP-OPTIMISED PRESSURE CONTROL FOR A CENTRALISED CO 2 COOLING SYSTEM IN AIRCRAFT APPLICATIONS

SUPERCRITICAL CO2 RANKINE CYCLE TEST LOOP (ROMA) - OPERATION AND INITIAL RESULTS

EXPERIMENTAL STUDY ON THE REPLACEMENT OF HFC-R134A BY HYDROCARBONS MIXTURE IN AUTOMOTIVE AIR CONDITIONER. Skudai, Johor, Malaysia 81310

A Scroll Expander with Heating Structure and Their Systems

Experimental investigation of a Scroll unit used as a compressor and as an expander in a Heat Pump/ ORC reversible unit

Experimental Study on Thermal Performance Improvement of Envelop Integrated with Phase Change Material in Air-conditioned Room

Performance Benefits for Organic Rankine Cycles with Flooded Expansion

Power Technologies Pervasive & Enabling

Application Of Oil Flooded Compression With Regeneration To A Packaged Heat Pump System

Experimental Performance of a Prototype Carbon Dioxide Compressor

Solar-Assisted Space Heating of a Highly Insulated Energy Efficient House

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions

Modelling of Phase Change Material Implemented Into Cold Storage Application

Two-Phase-Flow Turbines as Stand-Alone Throttle Replacement Units in Large Ton Centrifugal Chiller Installations

POWER MODULE COOLING FOR FUTURE ELECTRIC VEHICLE APPLICATIONS: A COOLANT COMPARISON OF OIL AND PGW

Heating Performance with a Volume Ratio on 2-Stage Compressor

Heat flow rate based thermal management for electric vehicles using a secondary loop heating and cooling system

Modelling of Residential Heating Systems using a Phase Change Material Storage System

ENVIRONMENTAL IMPACT OF HEAT PUMPING SYSTEMS

Emission Reductions. Frank Wolf Vice President OBRIST Engineering GmbH AUSTRIA Kjerstin Lien, Marc Chasserot, Frank Obrist

EXHAUST GAS. Converted into LIGHT

Testing and Optimization

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Optimization of Building Energy Management Systems

Recent U. S. R&D results from IEA HPP Annex 41

Modelling and Calibration of a Thermal Model for an Automotive Cabin using HumanComfort Library

Carbon Dioxide as an Eco-Friendly Refrigerant for Electric Vehicles

Seasonal Energy Efficiency Rating Improvement Of Residential HVAC Systems Using A Low Power Inverter With A PSC Compressor

System Cooling of Outdoor Wi-Fi Antenna

LECTURE-14. Air Refrigeration Cycles. Coefficient of Performance of a Refrigerator:


ScienceDirect. Compact hot water storage systems combining copper tube with high conductivity graphite and phase change materials

Waste Heat Recovery for Fuel Cell Electric Vehicle with Thermochemical Energy Storage

Innovative and climate-friendly cooling technologies

Assessing the Potential for Reduction in Peak Residential Electrical Loads Using a Heat Pump and Thermal Storage Systems

Investigation on A Ground Source Heat Pump System Integrated With Renewable Sources

Experimental Investigation of Heat Transfer in Components of a Hermetic Reciprocating Compressor

Modelling of an adsorption chiller with Modelica

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

SorTech package solution description

Unitary Air Conditioner Field Performance

CONTROL STRATEGIES FOR AUTOMOTIVE RANKINE SYSTEM EVALUATION USING A COSIMULATION PLATFORM ABSTRACT

Waste Heat Recovery Research at the Idaho National Laboratory

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Smart Integration of Thermal Management Systems for Electronics Cooling

CO2 Air Conditioning and Heating applied to city buses (COACH)

A Modified Heat Pump Air-Conditioning System for Electric Vehicle

Combined Heat and Power

An Optimal Maintenance Scheduler

Stan Shire. Thermal Energy Theme Lead

Energy Simulation And Optimized Retrofit Practices Applied To A Real Dwelling

Thermal Performances Of Three Types Of Ground Heat Exchangers In Short-Time Period Of Operation

Utilizing Heat Dump Capacity of a Small Pond Attached to Infloor Slab of a Net-Zero Energy House

The impact of hot and cold storages on a solar absorption cooling system for an office building

Reducing Operating Costs with Optimal Maintenance Scheduling

Experimental Results on a New Prototype Packaged Heat Pump System Retrofitted with Oil Flooded Compression and Regeneration Technology

Employment of Multiphase (Two Phase) Thermal Pump in Absorption Refrigeration System

NOWASTE: WASTE HEAT RE-USE FOR GREENER TRUCKS

Experimental Investigation on Heat Pump for Electric Vehicles with different refrigerant injection compressors

Performance Evaluation Of Thermally Activated Glass Fibre Reinforced Gypsum Building Equipped With Desiccant System

A Study on Engineering Application of Solar Heating System Assisted by Heat Pump

EXPERIMENTAL ANALYSIS OF ABSORPTION REFRIGERATION SYSTEM DRIVEN BY WASTE HEAT OF DIESEL ENGINE EXHAUST

Advanced measuring systems for the efficient use of geothermal energy as baseload-supplier

Measurement and Simulation of Startup and Shut Down of Heat Pumps

New Technology: CO 2 (R744) as an Alternative Refrigerant

Compressor Performance Comparison When Using R134 and R1234YF as Working Fluids

Advanced heat driven cooling cycles for low-temperature waste heat recovery

- 2 - SME Q1. (a) Briefly explain how the following methods used in a gas-turbine power plant increase the thermal efficiency:

Advanced simulation methods for heat pump systems

Heat Load Calculation for the Design of Environmental Control System of a Light Transport Aircraft

Design, modelling, performance optimization and experimentation of a reversible HP/ORC prototype.

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Assessment of C6F as Working Fluid for Organic Rankine Cycle Applications

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Secondary Loop System for Automotiv HVAC Units Under Different Climatic Conditions Nicholas Carsten Lemke j.lemke@tu-bs.de Julia Laura Lemke Juergen Koehler Follow this and additional works at: http://docs.lib.purdue.edu/iracc Lemke, Nicholas Carsten; Lemke, Julia Laura; and Koehler, Juergen, "Secondary Loop System for Automotiv HVAC Units Under Different Climatic Conditions" (2012). International Refrigeration and Air Conditioning Conference. Paper 1282. http://docs.lib.purdue.edu/iracc/1282 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

2393, Page 1 Secondary Loop System for Automotive HVAC Units under Different Climatic Conditions Nicholas Carsten Lemke 1 *, Julia Laura Lemke 1, Juergen Koehler 1 1 Technische Universität Braunschweig, Institut für Thermodynamik, Germany Contact Information (n.lemke@tu-bs.de) * Corresponding Author ABSTRACT Within the framework of the energy management of passenger cars new driving concepts like those with start-stopmode require an adaption of the HVAC system. Indirect systems with secondary loops might be a possibility to face these new requirements. As a part of the European TIFFE project (Thermal Systems Integration for Fuel Economy) a secondary loop system for mobile HVAC applications is currently in development. Among other things, the project pursues the realization of a compact and hermetic refrigeration unit called CRU with two secondary loops. Through applying a CRU some relevant advantages like the implementation of flammable or toxic refrigerants, the easy exchangeability of the HVAC system, or lower refrigerant charges might be achieved. Within this publication the modeling of the whole system as well as a CRU test rig with two secondary loops will be shown. Experimental and simulation results will be presented. For the cycle simulation the advanced Modelica library TIL Suite will be used. By utilization of a virtual test drive the influence of different climatic conditions and operation conditions like start-stop-mode will be shown. Part of the work at the Technische Universität Braunschweig within the TIFFE project deals with the use of phase change materials (PCM) for heat and cold storage implemented in the secondary loops. Macro-encapsulated paraffin could be one promising type of PCM for mobile applications. Measurement results for this kind of material and the influence of the PCM on the whole system will be presented. 1. INTRODUCTION In the near future, the vehicle thermal energy management of vehicles will become a relevant issue that will be crucial to achieve the CO 2 emission targets. The conventional approach uses an additional heat exchanger for every extra component to be cooled. This increases costs and might also decrease the efficiency of the system. An integrated and innovative approach is required to make the vehicle engine and energy systems effective with limited impact on the vehicle architecture and the design of the vehicle front end. Within the presented project TIFFE, an appropriate system based on a secondary loop HVAC system is currently in development. 2. SECONDARY LOOP SYSTEM The TIFFE project focuses on the development of an integrated thermal management system for cars and light commercial vehicles. Its function is to control the temperature of the entire engine and vehicle auxiliaries system and to reject the heat to the ambient. The energy transfer between the heat sources and heat sinks is realized by using secondary fluids like water-glycol-mixtures. The system is based on three loops: Heat of equal temperature levels is rejected through a high and a low temperature loop. Cooling power for compartment or component cooling is distributed via a third loop (see Figure 1). This architecture allows a very large system flexibility, modularity, and controllability.

2393, Page 2 Figure 1: TIFFE basic concept (Seccardini et al., 2011) 2.1 Compact Refrigeration Unit (CRU) Chilled water for the air conditioning of the passenger compartment is provided by a so called compact refrigeration unit (CRU). Figure 2 shows a scheme of such a system. As a special feature the condenser uses a separated subcooling section. In order to ensure a most efficient operation this section uses double cooled heat transfer fluid as a heat sink. The front thermal module has a special sub-cooling area for this purpose (see Figure 3). Figure 2: Schematic diagram of a compact refrigeration unit (CRU) with secondary loops

2393, Page 3 Figure 3: Liquid cooled condenser (left) and front thermal module (right) with sub-cooling sections (Seccardini et al., 2011) Equipped with an electrically driven compressor the CRU can be built hermetically with a very low charge of refrigerant. This might support the use of flammable, high pressure, or expensive refrigerants. Additionally, this unit allows an easy implementation of a heat pump function without any major modifications of the CRU - it only requires a change of the coolant circuit. 2.2 Heat Transfer Fluids and Phase Change Material (PCM) Using an additional heat transfer fluid on the evaporator side increases the thermal mass of the HVAC system and thereby also decelerates the dynamic of the cooling. This might be a disadvantage during cool down but on the other hand it could help to keep the comfort high during periods of stopped compressor (e.g. start-stop system of the car at a traffic light). Both aspects will be discussed in more detail in chapter 4.2. In the following section, the increase of this effect by using phase change material will be discussed. Ideal PCM does not increase its temperature while absorbing heat during the phase change (see figure 4). The temperature level of the phase change is given by the material. Suitable material for the evaporator side of an HVAC application should show a phase change somewhere in the temperature range between 0 C and 10 C to prevent icing of the heat exchanger on the one hand and to show a maximum effect on the other. Paraffin-based PCMs meet these requirements. Figure 4: Temperature of PCM during heat absorption

2393, Page 4 Two different approaches to the integration of PCM have been investigated within the project: Micro-encapsulated polystyrene-coated paraffin that flows as particles inside the heat transfer fluid (phase change slurry) and macro compound paraffin in a bulk package container perfused by the fluid (see Figure 5). Figure 5: Micro-encapsulated polystyrene-coated paraffin (left) and compound in a container (right) After some hours of operation the micro-encapsulated polystyrene-coated paraffin showed an abrasive effect on the impeller of the pump. Furthermore, the paraffin capsules tended to agglomerate (see Figure 6). Subsequently, only the compound system was investigated within the project in detail. Figure 6: Abrasiveness and agglomeration of micro-encapsulated polystyrene-coated paraffin 2.3 Experimental Work Two different test rigs have been built within the TIFFE project at the Institut für Thermodynamik. A CRU test bench allows the evaluation of the prototype heat exchangers and the analysis of the compact cycle itself. The PCM test rig was specially designed to investigate the performance of different PCM integrated in a secondary fluid flow. 2.3.1 CRU test rig A CRU test rig was recently completed at the Institut für Thermodynamik (see Figure 7). The main components are: the first generation prototype of the water cooled condenser with sub-cooling, a commercial plate type evaporator, an electrically driven compressor, and an electronic expansion device.

2393, Page 5 Figure 7: CRU test rig at the Institut für Thermodynamik First measurements show the principle operation of the test rig and the liquid cooled condenser (see Figure 8). The sub-cooled liquid refrigerant exits the condenser with a temperature of 32 C while the water-glycol-mixture has a temperature of 31 C at the inlet. More comprehensive measurements that will characterize the condenser in detail are currently being prepared using the methods of DoE. liquid cooled condenser Figure 8: Pressure-enthalpy-diagram of the CRU with the first generation prototype condenser 2.3.2 PCM test rig In addition to the CRU, a test bench dedicated to the measurement of PCM in the secondary loop was built. A schematic drawing of the test rig can be seen in Figure 9. The heat transfer fluid can perfuse or bypass the PCM container. The fluid may be heated or cooled by an electric heater and a cooled plate HX respectively. All relevant quantities like temperatures or volume flow rates are measured.

2393, Page 6 Figure 9: PCM test bench The results of a typical measurement are shown in Figure 10. The water-glycol-mixture had a temperature of -0.5 C at the start of the experiment. It was heated up with a heating power of 270W. In the first 100 seconds, heat was only stored as sensible heat, resulting in a linear raise of temperature. In the subsequent 150 seconds, the phase change of the PCM delayed the temperature increase. As a result, a threshold value of 6 C was reached 50 seconds later than it would be expected without phase change. This additional gain of time could be used to increase comfort and to safe energy in a car HVAC system. More details will be discussed in chapter 4. Figure 10: Heating-up test of PCM in a water-glycol-cycle 3. SIMULATION SETUP Within the project, a simulation of the CRU, the secondary loop (with and without PCM), and the cabin of the Daily IVECO test vehicle were built using Modelica and TIL Suite. Some simulation results will be presented in chapter 4. 3.1 Refrigeraton Cycle and Secondary Loop Figure 11 shows the graphical representation of the Modelica/TIL Suite (Tegethoff, 2010) model of the A/C cycle, the secondary loop, and the cabin model. For the A/C cycle standard models of the library have been used equivalent

Windshield Rear panel 2393, Page 7 to the test vehicles components that were built within the TIFFE project. The PCM was modeled to fit the measurement results of the test rig shown in the previous chapter. The cabin model will be discussed in chapter 3.2. Figure 11: Graphical representation of the Modelica/TIL Suite model 3.2 Cabin Model A one-dimensional simulation model of the test vehicle cabin was built as shown in Figure 12. The main components were modeled according to the geometry of the IVECO Daily. Radiant and convective heat transfer is included in the model as well as the exchange and moisture handling of the air in the cabin. Top Side panel Side window Dash board Air Passangers Seats Bottom Figure 12: Cabin model of the Daily IVECO test vehicle built with TIL Suite Add-On Cabin The cabin model was adapted to the geometry of the Daily IVECO test vehicle and fit to cool down measurements of the vehicle. Figure 13 shows a comparison between the simulated cool down of the vehicle and measurements.

2393, Page 8 Figure 13: Cool down of the Daily IVECO measurements vs. simulation 4. VIRTUAL TESTDRIVE In order to analyze the impact of an optional integration of PCM in the secondary fluid cycle, the presented simulation setup was used. A simulated one-hour trip with several stops was used for this purpose. 4.1 Route Example and Ambient Conditions The exemplary route in this study started on July 21 st near Rosenheim (Germany) and ended one hour later in the city center of Munich (see Figure 14). The driving speed was determined using standard route planner software. Using the time of the day and the vehicle orientation along with the solar radiation data, the calculation of the solar insulation was allowed. Car Stops Figure 14: Route of the virtual test drive

2393, Page 9 The ambient climatic conditions were calculated using the software METEONORM. In Figure 15, the ambient air conditions are shown in a h-x-diagram. Near the end of the trip, higher temperatures were assumed to take into account the so called urban heat island near the center of a city (Matzarakis, 2001). Figure 15: h-x-diagram of ambient conditions during the virtual test drive 4.2 Simulation Results Figure 16 shows as a result of the simulation the average temperature of the passenger compartment and the temperature at the air inlet into the cabin. Three cases have been simulated: a basic secondary loop system, a system with one liter of additional water-glycol-mixture in the secondary loop, and a system with one liter of PCM instead. Figure 16: Air temperatures during the virtual test drive At the beginning of the cool down the basic system shows the most dynamic temperature decrease. The PCM system shows a sharp bend and a slowed temperature decrease as the temperature of the secondary loop fluid falls below the phase change temperature of the PCM. All systems show a distinct temperature increase when the compressor stops

2393, Page 10 due to a motor-off-phase at a traffic light. Later on (t>500s) until the stop at t=2470s all systems show a more or less equivalent performance. On the right hand side of Figure 16 the longer stop-phase is shown in more detail. All systems show increasing temperatures after the compressor stops at t=2470s. About 50 seconds after the stop, the PCM system can make use of its inherent advantage and keep the air inlet temperature below a level of 10 C for the remaining stop time. The other two systems would have to restart motor and compressor to prevent odor nuisance due to high air temperatures in combination with a wet evaporator. 5. CONCLUSIONS The TIFFE project focuses on the development of an integrated thermal management system for cars and light commercial vehicles that has the function to control the temperature of all the engine and vehicle auxiliaries systems and to reject the heat to the ambient. Two test rigs for the analysis of a compact refrigeration unit and phase change material within the secondary loop have been presented. A simulation setup using modelica and TIL Suite for the A/C-cycle and the compartment model has been developed. The simulation of a virtual test drive was presented. The cycle with PCM has shown significant advantages during longer stop phases of the compressor. REFERENCES Matzarakis, A., 2001, Die thermische Komponente des Stadtklimas, Meterologisches Institut der Universität Freiburg, Habilitation, Freiburg Seccardini, R., Mattiello, F., Malvicino, C., 2011, TIFFE thermal system Light commercial vehicle application, 4th European Workshop on Mobile Air Conditioning and Vehicle Thermal Systems, Turin Tegethoff, W., Schulze, C., 2010, Simulation of thermal Systems in SimulationX using TIL and TILMedia, ITI Symposium 2010, Dresden ACKNOWLEDGEMENT The TIFFE project is supported by the European Community within the 7 th Framework Programme.